| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 CrAdmitted-Finance 1 SANSKRUTI APPARTMENT MURKUTE LANE NEW PANDIT COLONY NASHIK TAL DIST NASHIL | NASHIK | NASHIK | MAHARASHTRA | 422001 | L1 | Admitted-Finance | |
| 2 | L2₹30.6 Cr+₹1.9 Cr (6.72%)Admitted-Finance 401 402 AMIT CRYSTAL ABOVE BANK OF BARODA SENAPATI BAPAT ROAD PUNE 411016 SHIVAJI NAGAR PUNE MAHARASHTRA 411016 | PUNE | MAHARASHTRA | 411016 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical Techno-commercially not acceptable | |
| 4 | Rejected-Technical | - | Rejected-Technical Techno-commercially not acceptable | |
| 5 | Rejected-Technical | - | Rejected-Technical Techno-commercially not acceptable |
| Sl No | Description | Qty | Unit | Harsh Constructions Private Limited L1 | Shubham EPC Private Limited L2 |
|---|---|---|---|---|---|
| 1.00SECTION - A Excavation:- | |||||
| 2.00 | Excavation for foundation in Hard rock by blasting including trimming and leveling the bed by chiseling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum, watering, ramming, etc. complete. | 2,631.58 | Cubic Metre | 1,250 ₹32,89,475 Lowest | 1,325 ₹34,86,843.5 |
| 3.00 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. | 5,000.61 | Square Metre | 65 ₹3,25,039.65 Lowest | 72 ₹3,60,043.92 |
| 4.00 | Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers
including watering and compacting etc. complete. | 20 | Cubic Metre | 125 ₹2,500 Lowest | 150 ₹3,000 |
| 5.00 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc.
complete. | 3,291.42 | Cubic Metre | 860 ₹28,30,621.2 Lowest | 945 ₹31,10,391.9 |
| 6.00 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. | 442.76 | Cubic Metre | 1,889 ₹8,36,373.64 | 1,750 ₹7,74,830 Lowest |
| 7.00Structural Steel Work:- | |||||
| 8.00 | Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.)
Spec.Number: As directed by Engineer- in-charge. | 9.75 | Square Metre | 2,200 ₹21,450 Lowest | 2,275 ₹22,181.25 |
| 9.00 | Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete.
Spec. Number : As directed by Engineer-in-charge. | 5 | Metric Tonne | 1,08,325 ₹5,41,625 Lowest | 1,15,236 ₹5,76,180 |
| 10.00 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting
complete. | 10 | Metric Tonne | 1,12,678 ₹11,26,780 Lowest | 1,25,635 ₹12,56,350 |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
14 Mar 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager (CP)
Pride Purple Coronet, 2nd Floor, Baner Road, Baner, Pune - 411045
Tender for appointment of agency for carrying out construction and allied works for proposed corporate office building at Balewadi, Pune for MNGL, Pune.
2023_MNGL_146784_1
MNGL/CP/2022-23/206
Open Tender
Construction Works
Works
540 days
Pune
As per tender Document.
16 documents required · 16 mandatory
₹0
₹2 L
Yes
MNGL, Baner, Pune
25 Apr 2023
24 Feb 2023
15 Mar 2023
24 Feb 2023
14 Mar 2023
24 Feb 2023
28 Feb 2023
Amount
SECTION - A Excavation:-
Excavation for foundation in Hard rock by blasting including trimming and leveling the bed by chiseling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum, watering, ramming, etc. complete.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Structural Steel Work:-
Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.Number: As directed by Engineer- in-charge.
Providing structural steel work of rectangular hollow steel section for steel trusses, other similar trussed items like purlin and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/ welded connections and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade complete. Spec. Number : As directed by Engineer-in-charge.
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
Plain Cement Concrete:-
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
Reinforced Cement Concrete :-
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
M40 Concrete Grade
M30 Concrete Grade
Reinforced Cement Concrete:-
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto Tremix
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Reinforced Cement Concrete:-
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Reinforced Cement Concrete:-
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Reinforced Cement Concrete:-
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Reinforced Cement Concrete:-
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Ground Floor
Terrace
Reinforced Cement Concrete:-
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Reinforced STEEL:-
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Brick Masonry:-
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Brick Masonry:-
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Water Proofing:-
Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete.
Water Proofing:-
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Water Proofing:-
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Water Proofing:-
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)
Ground Floor
1st Floor
3rd Floor
4th Floor
5th Floor
Water Proofing:-
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
Water Proofing:-
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
L. Basement
U. Basement
Water Proofing:-
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Water Proofing:-
Providing and applying a base coat comprising of 1 Kilogram Polydee-MC and 1Kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.
Ground
Plastering and Pointing:-
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Plastering and Pointing:-
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Plastering and Pointing:-
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete.
L. Basement
U. Basement
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Plastering and Pointing:-
Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Terrace
Plastering and Pointing:-
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Paving Flooring and dado:-
Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing,cleaning complete. b) Granite
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Paving Flooring and dado:-
Providing and preparing kitchen otta up to 75 cm width,made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete.
2nd Floor
3rd Floor
4th Floor
5th Floor
Paving Flooring and dado:-
Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand)
Paving Flooring and dado:-
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Colouring:-
Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.
Basement L
Basement U
Ground
First
Second
Third
Fourth
Fifth
Terrace
Doors and Windows:-
Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Doors and Windows:-
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete.
Ground Floor
1st Floor
2nd Floor
3rd Floor
4th Floor
5th Floor
Iron Work:-
Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete
Basement L
Basement U
Ground
First
Second
Third
Fourth
Fifth
Terrace
Iron Work:-
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
Basement L
Basement U
Ground
First
Second
Third
Fourth
Fifth
Terrace
The system shall be designed of floor height units spanning between the floors with face / Slab mounted brackets on mullion with provision to accommodate movement at all floor levels and at every grid panels horizontally. System shall be mounted on to the bracket arrangement with the help of Anchor Fastner. The Bracketing system with Aluminium Alloy / MS HDG with built in serration & serrated wasthers. The system shall be designed to accommodate 24mm IGU in vision area & 6mm SGU glass in spandrel area at all floor level. The spandrel panel shall have aluminium adaptor profile to balance the IGU and SGU glass thickness in black anodised. System shall accomodate openable panel as per architectural requirment in the unitised system . All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard shall be fixed at all vertial & Horizontal grooves. Each glass panel shall be structurally glazed on the main unitised profile system.
The three barrier gasket system consists of 1st , 2nd & 3rd barrier of EPDM gaskets to achieve the required compression & seal in the system. EPDM Gaskets shall be of micro cured (Online Curing) with shore A hardness of 60-65. With Structural & weather sealants, Open PU cell Spacer tape, backer rod, Bracketing system with MS hot dip galvanized / Aluminium Alloy of 6005 T5 brackets designed to accommodate three dimensional movements with serrated plate and serrated washers, SS 316 grade fasteners & Anchor Fastners, nylon separators to prevent bi-metallic contacts, all complete required to perform as per specification and drawing in conjunction with BOQ.
The system design shall be based on Open joint system & design shall include pressure equalization with minimum 3 barrier gaskets for improved weather performance, drainage at all floor levels, spandrel panel shall have pressure release slots on vertical side of profile system to avoid condensation. Transom shall be overlap with mullion to have proper drainge to mullion. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80-90 deg Cel & temperature differential of 25 deg cel without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.
The system design shall be based on Open joint system & design shall include pressure equalization with minimum 3 barrier gaskets for improved weather performance, drainage at all floor levels, spandrel panel shall have pressure release slots on vertical side of profile system to avoid condensation. Transom shall be overlap with mullion to have proper drainge to mullion. The design to accommodate building movements, thermal expansions & the seismic movements. The system shall be designed considering surface temperatures of 80-90 deg Cel & temperature differential of 25 deg cel without creating excess stress in the system. All metal joints in the wet area shall be small joint sealant applied to ensure water tightness.
Supply & Installation of Elevator at Site, 816 Kgs for ground, L. Basement, U. Basement and Ground floors having rated 1.5m/s, stainless steel sheet of hairline finish doors, car having handrails, MS girders, Bracing of adequate size, side panels of stainless steel sheet of hairline finish with stainless steel leather finish cladding, stainless steel cabin, car doors and landing doors of fully automatic, Floor position indicator in car & car position indicator at all landings without machine room with electronic microprocessor control unit, VVVF with ARD, overload warning device, infrared curtain & intercom system etc. completed as per the product.
Supply & Installation of Elevator at Site, 816 Kgs for ground, U. Basement to Fifth floors having rated 1.5m/s, stainless steel sheet of hairline finish doors, car having handrails, MS girders, Bracing of adequate size, side panels of stainless steel sheet of hairline finish with stainless steel leather finish cladding, stainless steel cabin, car doors and landing doors of fully automatic, Floor position indicator in car & car position indicator at all landings without machine room with electronic microprocessor control unit, VVVF with ARD, overload warning device, infrared curtain & intercom system etc. completed as per the product.
Supply & execution of post tensioning work includes supply, fabricate, install high tensile post tensioning strands confirming to IS as per design, providing G.I. corrugated duct sheathing, decoiling the strands, cutting to the required lengths, preparing cables of required numbers strands as per drawings, inserting cables within the sheathing. fixing tendons support bars, supervising anti-bursting reinforcements, maintaining profile during concreting operations, stressing of cables in sequence as per design to required loads, with required stressing jacks, recording the readings and grouting with cement grout having maximum water cement ratio 0.4 using approved admixture for workability. All materials will be tested as per QAP-Materials; PT for flat slabs, banded beams, steel beams, shear walls, etc; weights shall be measured for all items; rate is deemed to include all wastages; PT items procurement price shall be considered as per basic rate provided and any variation between the actual procurement price and this rate shall be paid extra; if PT items are provided as free issue, the cost of such items computed at basic rate shall be deducted from the overall price;
Providing and constructing R.C.C. underground storage tank of M-30 mix cement concrete R.C.C. floor slab, walls etc, including excavation M-10 mix P.C.C., form work, vibrating, water curing etc.including M.S. rungs heavy type mosquittoproof covers, inlets and outlets, oveflow pipe including water proofing plaster of 1:2 mix cement and sand mortar to the inside surface and wata at the junction of walls and floor etc. and sand faced plaster of 1:4 mix in two coats from outside surfaces and top finish with 1:4 cement plaster as per working designs and drwawings including testing of water leakages including water proofing etc. complete.
STP 23 KLD:-
Civil work for STP 23 KLD capacity as per the design & specifications
Section A : (I) Total Amount inclusive all taxes in Rs.
(II) Add 5% Corporation Charges on items (SR NO.1 from to 274 ) in Rs inclusive taxes
(III) Civil Cost = (I)+(II) in Rs.
(IV) Labour Insurance 0.5% on III (in Rs) inclusive taxes
(V) Asset insurance @ 1% per annum
Total Cost of Civil works inclusive tax & duties - Section: A
SECTION - B Water Supply and Sanitary Fitting:-
Providing and laying cast iron pipes of B class of 80mm diameter with sockets and spigot ends/ flanges and cast centrifugally / vertically including specials, laying pipes and back filling the trench complete including excavation.
Providing and laying cast iron pipes of B class of 100mm diameter with sockets and spigot ends/ flanges and cast centrifugally/vertically including specials, laying pipes and back filling the trench complete including excavation.
Providing and laying cast iron pipes of B class of 150mm diameter with sockets and spiget ends/ flanges and cast centrifugally/ vertically including specials, laying pipes and back filling the trench complete including excavation.
Providing and making flanged connection for the 80mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete.
Providing and making flanged connection for the 100mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete.
Providing and making flanged connection for the 150mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete.
Providing and fixing 50mm diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber]
Providing and fixing 80mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock.[Without chamber].
Providing and fixing 100mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangements and lock. [Without chamber].
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.
Providing and fixing screw down for 65 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing screw down for 80 mm. dia. wheeled stop tap of brass including necessary sockets/union nut complete.
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint)
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
Water Supply and Sanitary Fitting:-
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogram with lid and frame fixed in cement concrete.
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m )
Building Miscellaneous Item:-
Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle ( 50 x 50x 6mm) post at 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in ( 1:4:8) cement concrete block of 45x45x45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete
Rain water harvesting:-
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10- 25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well screen pipes with ribs of 100mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge.
Supplying, filling, spreading & leveling stone boulders of size range 5cm to 20cm in recharge pit, in the required thickness, for all leads & lifts, all complete as per the direction of Engineer- in-charge.
Supplying, filling, spreading & leveling gravels of size range 5mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer- incharge.
Supplying, filling, spreading & leveling coarse fine aggregate (crushed sand VSI grade finely washed etc.) of size range 1.5mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer in charge.
Gravel packing in tubewell construction in accordance with IS:4097, including providing gravel: fine/ medium/ coarse, in required grading & sizes as per the actual requirement, all complete as per direction of Engineer in charge.
Section B: (I) Total Amount Including Tax in Rs.
(II) Add 5% Corporation Charges on items (SR No.293 from to 335 ) in Rs inclusive Tax
Total Amount for Plumbing works Inclusive all taxes, duties & Charges : Section -B (in Rs.) (I+II)
SECTION - C Firefighting Work
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.
Supplying and erecting D.C.P. type fire extinguisher 9 kg capacity cartridge type with Gun Metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Main Fire Pumps (Single Stage Centrifugal) (FF-MFP/SSC):-
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main single stage pump, of 1800 LPM at 76 m head centrifugal type, 50 HP (37 kW), 3 phase, 415 volt, 50Hz or of suitable HP complete as per specification no. FF-MFP/SSC
Jockey Pumps (Centrifugal) (FF-MFP/JP):-
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 56 m head, 15 HP (11 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP
Booster Pump (FF-MFP/BP):-
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of booster pump of 900 LPM at 40 m Head, 12.5 HP (10 KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/BP
Pipes (FF-PP):-
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Valves (FF-FV):-
Supplying and erecting cast iron foot valve ball type/flap type of size 80 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and erecting cast iron foot valve ball type/flap type of size 150 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV
End Line Strainer (positive suction) (ELS):-
Supplying and erecting 75/80 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 100 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 200 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Sluice Valve:-
Supplying and erecting cast iron double flange sluice valve 100 mm dia. complete as per specification no. FF-VL/SV
Supplying and erecting cast iron double flange sluice valve 160 mm dia. complete as per specification no. FF-VL/SV
Butterfly Valves (BFV):-
Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 65 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 200 mm dia. complete as per specification no. FF-VL/BFV
Non Return Valves (NRV):-
Supplying and erecting cast iron double flange NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Gate / Wheel Valves (GV):-
Supplying & erecting gun metal gate valve of size 25 mm dia complete as per specification no. FF-VL/GV
Supplying & erecting gun metal gate valve of size 50 mm dia complete as per specification no. FF-VL/GV
Hydrant Valves (HV):-
Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Fire Fighting Accessories (FF-FFA):-
Hose Reel with Drum (HR):- Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV
Hose Pipes:-
Supplying fire fighting controlled percolation (C.P.) Hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/CPH
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying & erecting high pressure poly propylene hose pipe 19 mm dia complete as per specification no. FF-FFA/HOP
Nozzles (NZ):-
Supplying & erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ
Fire Brigade Connection (FBC):-
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FBC
Siamese Connection (SMC):-
Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
Air Cushion Tank (Air Vessel) (ACT):-
Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT
Air Release Valve (ARV):-
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Pressure Gauge (PG):-
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Pressure Switch(PS):-
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Orifice Plate(OP):-
Supplying and erecting one no. brass orifice plate having 6 mm. thickness, 160 mm outer dia and required/proper diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP
MS / CRCA Boxes (BOX):-
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
NOTE:- Specifications of the above items shall conform to respective Indian standards. MS stands forMild Steel. CRCA stands for Cold Rolled Close Annealed.
Conventional Fire Alarm System (FF-FAS):-
Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP
Supplying, installing, testing and commissioning hooters with CRCA enclosure complete as per specification no. FF-FAAS/HTR
Supplying, installing, testing and commissioning remote response indicators complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning FR, XLPE armoured cable 8 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning FR, XLPE armoured cable 12 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories complete as per specification no. FF-FAAS/FACP
NOTE:- 1. For item no 416 to 419 increase overall rate by 7.5% for FRLS. 2. For item no 420 increase overall rate by 25 % for additional zone as per requirement. 3. Above rates are for Non-Addressable type.
Supplying, installing, testing and commissioning 2 Zone, local signal control panel (LCP) with standard accessories complete as per specification no. FF-FAAS/LCP
NOTE:- 1. Increase overall rate by 10 % for additional zone as per requirement. 2. Above items are for Non-Addressable type.
Sprinklers (FF-SPR):-
Supplying, erecting, testing and commissioning of 15 mm (½") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR
Supplying, erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 75/80 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes
Supplying, erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 100 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes
FIRE SEALANT SYSTEM (FF-FRM):-
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings with all kinds of cables, pipes and cable support system in steel and aluminium and plastic profiles ( Except hollow core conductors). The residual openings shall be closed with filler, as per specification no. FF-FRM
NOTE:- For estimating purpose consider one bag of 20kg to cover 300mm x 400mm area 150mm thick or 0.018 m3
FIRE PROTECTION SYSTEM(FIRE PUMPS,EQUIPMENTS & ACCESSORIES):-
FIRE PUMPS EQUIPMENTS
Supplying, installation, testing and commissioning of diesel engine driven fire pump suitable for automatic operation and consisting of following: complete in all respect as required.
Horizontal split casing high pressure Single/Multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 137.0 m3/Hr at 70.0 m. head conforming to IS 1520.
Suitable HP, 1800 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminum sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red color etc. as required.
Pump shall be capable of furnishing not less than 150% of rated capacity at a head not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
1 No. 8 hours capacity day oil storage tank fabricated from 3 mm thick M.S. plates. Tank shall be provided with inlet, outlet, overflow, air vent, drain connections, filling connection & magnetic level indicator. Tank shall be mounted on a suitable steel structure (Painted with 2 coats of red oxide paint). Tank shall be provided with epoxy coat from inside & two or more coats of synthetic enamel paint outside over two coats of red oxide primer. Diesel storage tank shall be double skin.
24 volts 180 AH lead acid battery (12/24 volts - 2 Nos) with boost/Trickle charger for starting the engine automatically complete as required.
M. S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.
suitable cement concrete foundation duly plastered with anti vibration pads.
Flexible Coupling & coupling guard for direct coupling of engine & pump.
Drain pipe 80 mm dia
Diesel Engine driven pump of: ("Make-Clarke/Caterpillar/Kirloskar /Cummins ")
Discharge flow : 137.0 m3/hr (2280 LPM or38.0 LPS)
App. Head : 70.0 M
App HP : As per Manufacturer
Rate should include inter connecting cables & foundation bolts, grouting of Foundation bolts and other accessories required.
Providing & fixing double flanged flexicon expansion joint (expansion bellows) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required.
80 mm dia
100 mm dia
150 mm dia
Providing, fixing, testing & commissioning of brass quartzoid sprinklers (UL approved) of 15 mm dia size, suitable for sustaining the pressure on the seat & water hammer effect. The type & temperature rating shall be as follows :("Make-Tyco/Spray Safe/Viking/HD.")
Sidewell extended coverage (68 °C) sprinkler quick response type.
Providing, fixing, testing and commissioning of Installation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer's specifications complete as required.("Make-HD/Viking/Tyco")
150 mm dia
Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910
9 Litres
Supply, installation, testing and commissioning of following types of Trolley (Wheel) Mounted extinguishers.
"ABC" type Fire Extinguisher of 25 Kgs. Capacity.
"CO2" type Fire Extinguisher of 22.5 Kgs. capacity.
Mechanical foam type Extinguisher 50 Litres.
Section C Firefighting Cost Including all Taxes & duties in Rs.
SECTION - D PVC Flexible/Rigid Conduits/Casing-n-Capping/ Under Floor Trunking/ Raceways and Box Trunking
(WG-MA/CON):-
Supplying and erecting UPVC reinforced flexible conduit 20 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.
Supplying and erecting HMS PVC conduit 20 mm dia. with PVC accessories on wall / ceiling as per specification No: WG-MA/CON.
Bunch of Wires (WG-MA/BW):-
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Fans (FG-FN):-
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.
Supplying and erecting fresh air cum exhaust fan of light duty250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.
Air Conditioners (AP-AC):-
Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 2 TR capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete with Refrigerants R410 A/R32 and copper condenser at position. specification no. AP-AC/SAC
Supplying, installing, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity having ISEER minimum 4.50 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete with Refrigerants R410 A /R32 and copper condenser at position. specification no. APAC/ SAC
Providing and pasting superior quality Sun control film on glass to achieve better cooling effect having 1.5 / 2 mm thickness, ultra violet transmittance less than 2% and solar heat rejection 78% in approved manner.
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 12 mm complete.
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 16 mm complete.
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 22 mm complete.
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 32 mm complete.
NOTE:- 1. For copper pipe nitrile rubber insulation refer to chapter 4.2. 2. For drain piping refer rates of PVC pipes from chapter no. 1. 3. If cost of any appliances for repair more than 50% then those shall be proposed for replacement.
VRV/VRF Air conditioning (New):-
Supplying, erecting, testing and commissioning 10 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 12 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 14 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 16 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 18 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 20 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 24 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 26 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 28 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.0TR (358 cfm) to 1.25TR (417 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.0TR ( 441 cfm ) / 1.3TR ( 512 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.5TR ( 512 cfm ) / 1.8TR ( 618 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.0TR ( 618 cfm ) / 2.3TR ( 671 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.6TR ( 918 cfm ) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 3.0TR ( 1100 cfm ) to 3.2TR ( 1165 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 3.3TR ( 1165 cfm ) to 4.0TR ( 1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 4.1TR ( 1218 cfm ) to 5.0TR ( 1624 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR ( 512 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.4TR ( 512 cfm ) to 2.0TR ( 618 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.8TR ( 575 cfm ) to 2.7TR ( 953 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRV / VRF based ceiling suspended 4.0TR Treated Fresh Air ( TFA ) ( 3310 cfm ) indoor unit with evaporator fan with motor, copper tube, aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, corded / cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area with suitable ceiling suspension arrangement and an electronic control console with an additional refrigerant and oil charge as per requirement during installation connected with the system complete.
Supply, installation, testing and commissioning of VRV / VRF based ceiling suspended 6.5TR Treated Fresh Air ( TFA ) ( 5380 cfm ) indoor unit with evaporator fan with motor, copper tube, aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, corded / cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area with suitable ceiling suspension arrangement and an electronic control console with an additional refrigerant and oil charge as per requirement during installation connected with the system complete.
Supply, installation, testing and commissioning of VRV / VRF based ceiling suspended 8.0TR ( 6600 cfm ) to 10TR ( 8200 cfm ) Treated Fresh Air ( TFA ) indoor unit with evaporator fan with motor, copper tube, aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, corded / cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area with suitable ceiling suspension arrangement and an electronic control console with an additional refrigerant and oil charge as per requirement during installation connected with the system complete.
Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 300 cfm capacity with maintaining the static pressure minimum 20 mm of Hg complete suitable to operate on 1ph, 230 V, 50Hz, A.C. supply.
Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 20 mm of Hg complete suitable to operate on 1ph, 230 V, 50Hz, A.C. supply.
Supplying and erecting an air flow regulating valves / dampers in provided flexible or rigid duct / pipe of 100 mm size with an alteration for existing flexible pvc pipe duct and necessary joints, sealing, couplings complete at position.
Supplying and erecting an air flow regulating valves / dampers in provided flexible or rigid duct / pipe of 150 mm size with an alteration for existing flexible pvc pipe duct and necessary joints, sealing, couplings complete at position.
Supplying and erecting an air flow regulating valves / dampers in provided flexible or rigid duct / pipe of 200 mm size with an alteration for existing flexible pvc pipe duct and necessary joints, sealing, couplings complete at position.
Supply, installation, testing and commissioning air curtain of 3 feet width having air throw velocity of 12 to 14 m/sec, low noise level up to 38 to 46 dB suitable for door height upto 9 feet, working on 1ph, 230 V, 50Hz, A.C. supply.
Supply, installation, testing and commissioning air curtain of 4 feet width having air throw velocity of 21 m/sec, low noise level up to 38 to 46 dB suitable for door height upto 9 feet, working on 1ph, 230 V, 50Hz, A.C. supply.
Supply, installation, testing and commissioning air curtain of 6 feet width having air throw velocity of 21 m/sec, low noise level up to 38 to 46 dB suitable for door height upto 9 feet, working on 1ph, 230 V, 50Hz, A.C. supply.
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supply, installation, testing and commissioning cordless remote contol having colour LCD panel, real time clock, temperature limitation (16 to 30 degree Cent.), functions like filter clean reminder timer suitable to communicate with wired controller complete.
Supplying, erecting, testing and commissioning centralised programmable remote contol panel (HMI) touch manager controls minimum 16 system of minimum 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having minimum 200 mm size colour LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall with an arrangement to integrate with provided fire alarm system.
Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, installation, testing and commissioning of volume control box with collor for control damper of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete.
Providing adhesive thermal insulation for supply / return air duct with 19 mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2007.
Providing and applying of accoustic insulation for air ducts with 25 mm thick, 48kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.
Supplying & erecting tile type modular diffuser made from aluminium sheet complete with powder coated matching to the ceiling shade for provided suuply and return air.
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.
Supplying and installing of coller damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of required size
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45 degree.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
SITC of Ductless Car Parking Ventilation Work for parking
Car Parking Ventilation And Smoke Evacuation System.
The system shall consist of axial smoke spill fans and high thrust Jet Impulse fans. The system shall be operated by Timer Based Panel, In normal mode the fans to run at 6ACPH and fire mode additional 6 ACPH to be calculated total ACPH in fire mode to be 12. The system shall be integrated there a logic controller (PLC Based) along with program mace master logic controller with non volalife memory. The communication protocol shared be either BACnet or MOD bus with controller panel and BMS. Necessary protocol to be made available to BMS agency by vender for interfaculty. The detailed specification are enclosed in tender documents for individual item.
Standard Long Cased Axial Flow Extract Fans For Car Parking Ventilation
AREA/ CFM / Mode/ ST Pr. (MM)/ RPM/ Motor (kw)
Basement-2 -Fire Compartment-1
Car Parking Area of Basement-2/ 14900 CFM / Normal cum fire Mode/ 20mm / 1440 RPM/ 3.75KW
Car Parking Area of Basement-2/ 14900 CFM / Fresh (make up) air Normal cum fire Mode/ 20 mm / 960 RPM/ 3.75KW
Basement-2 -Fire Compartment-2
Car Parking Area of Basement-2/ 24800 CFM / Normal cum fire Mode/ 20 mm / 1440 RPM/ 5.5KW
Car Parking Area of Basement-2/ 24800 CFM / Fresh (make up) air Normal cum fire Mode/ 20 mm / 960 RPM/5.5KW
Basement-1 -Fire Compartment-1
Car Parking Area of Basement-1/ 19100 CFM / Normal cum fire Mode/ 20 mm / 1440 RPM/ 3.75KW
Car Parking Area of Basement-1/ 19100 CFM / Fresh (make up) air Normal cum fire Mode/ 20mm / 960 RPM/ 3.75KW
Basement-1 -Fire Compartment-2
Car Parking Area of Basement-1/ 15500 CFM / Normal cum fire Mode/ 20 mm / 960 RPM/ 3.75KW
Car Parking Area of Basement-1/ 15500 CFM / add in Fire Mode/ 20 mm / 1440 RPM/ 3.75KW
CAR PARKING IMPULSE JET FANS:-
Supply, installing, testing and commissioning of Ductless Ventilation / Jet fans for Normal ventilation and Smoke Extraction application for car parking. The complete fan assembly with its Casing, impeller & motor (not only the motor or one of the item) shall be sourced from one manufacturer and certified as tested for 250°C for 2 hours operation. Adequate number of CO sensors,electrical starter panels with power / control cabling for 3 phase fans and logic controller with necessary control cabling will form a part of the same.
Fan Dia./Motor (kw) /RPM/Thrust (Newton)
400 mm dia/2.5kw/0.58kw/2900/1440/86 N/22N
SENSOR & DETECTOR:-
Supply & installation of CO gas Detector PolyGard Carbon Monoxide ( CO ) Sensor in MODBUS RS 45 protocol. Sensor shall be suitable for Measuring range 0 – 300 ppm (5%) & along with LCD for displaying PPM level and menu parameters (required for field programming). Coverage Area of sensor should be not less than 700 m2 (7500 ft2) or 15m (50 ft) radius.
CO gas Sensor & Detector
CFD ANALYSIS FOR 4 FIRE COMPARTMENT ZONE OF 2 NUMBER BASEMENT :
Computational Fluid Dynamics (CFD) analysis to include fire mode operation and related 3D modelling, simulation, intake openings, extract fans, exhaust openings, jet fans, ACH, air movement, time taken for smoke evacuation and related out puts ( 4 Nos. fire case out puts in different part of basement) in soft copy along with 5 sets of CD copies.
SITC of Standard Long Cased Axial Flow Extract Fan of Staircase Lift Well & Lift Lobby Pressurisation :-
Supply, installation, testing & commissioning of Axial Flow Fan. Double flanged casing is produced in mild steel or galvanised Steel, the impeller having manually adjustable pitch aerofoil blades is made of PPG, PAG or Aluminium. Fan shall be with belt driven tube/vane axial centrifugal fan. Fan and casing shall be suitable for smoke exhaust application. The fan motor Shall be TEFC drive IE-1 motor suitable for 215/415+ 10% volts, 1/3 phase 50 Hz AC supply, Terminal box in IP65 mounted at the outside of the casing for easy wiring, use a flexible and weatherproof cable .an static pressure shall be as indicated . Fan shall be with fire retardant flexible connection at inlet and outlet. Complete with all necessary accessories such as Mounting arrangement, frame and supports such as spring type anti-vibration hangers etc., complete as per drawings and specifications. Fans shall be activated from fire signal from fire alarm system. (The bidder shall submit fan performance curves for all fans)
AREA/ CFM / ESP Pr.(MM)/Motor KWs
Staircase Pressurization
11400 CFM/ Terrace/ FM/ ESP-25 mm /3.75kw
10900 CFM/ Terrace/ FM/ ESP-25 mm /3.75kw
Lift Well Pressurization:-
6700 CFM/ Terrace FM / ESP-15 mm / 2.2KWs
SITC of Air Handling Units
Supply, installation, balancing and commissioning of double skin air handling units . The AHU housing shall be made of 45±2mm thick panels consisting of 0.8 mm thick galvanized pre-plasticised/powder coated sheet on outside and 0.63 mm thick plain GI sheet inside with polyurethane foam (PUF) 40±2 kg/m3 density insulation factory injected between them by injection moulding machine. AHU housing framing structure shall be thermal break structure type. The AHU shall have a fan section with DIDW forward / Backward curved centrifugal fan, TEFC drive, IE-3 motor suitable for 215/415+ 10% volts, 1/3 phase 50 Hz AC supply, motor mounting arrangement inside the casings, stainless steel (18G) drain pan with PUF insulation, belt drive system and with vibration isolators, Coil section with ARI 410A compliant Cu Tube / Al finned 6 Row deep -13 FPI Dx coil, with suitable for VRF connective (Coil dia should be 3/8” ), aluminium damper on the outlet of AHU, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters , double fire retardant canvas connections and access doors to attend the motor/fan, etc. complete as per drawings and specifications. Filters shall have efficiency of 90 % down to 10 micron as per ASHRAE standard. AHU should be designed in such a way considering 20 to 30% clogged filters. The motor shall be suitable for operation with VFD. AHU noise should be below 55 dB(A) after the AHU. If any acoustic lining required for reducing the noise, so provide inside the AHU of the same. Minimum below mention external static pressure shall be considered. However, actual total static pressure shall be calculated and confirmed by the vendor at the time of bidding. Max. Face Velocity Across Coil = 500 FPM & Max. Face Velocity Across Pre and Fine Filter = 350 FPM starter panel inclusive with all AHUs cabling between starter to AHU in the scope of vendor(Avg length 20mtr). complete as per specification and of following capacities. Paper type commissioning filter shall be also included in this scope. all Refrigerant joint only Y / T Type also included in this scope. Approved Make :- Zeco / Edgetech / Nutech / Citizen / VTS FM-Floor mounted
SITC of AHU KIT Supply, installation, balancing and commissioning o AHU Kit. The capacities of AHU units shall be as following. Supply of Highly Efficient Electronic Expansion Valve capable to operate in Cooling Mode (Ref. Temp 6 Deg C) & Heating mode (Ref. Temp 50 Deg C), compatible with R410a VRV Outdoor units, & Capacity variation of >20% to provide variable cooling load. The AHU Expansion valve shall be supplied along with Communication box for Integrated control of Refrigerant flow as per the system requirement and Fan Speed control with 3 Step modulation, Fire protection Auto Shut off Valve. The control box shall be pre supplied with necessary sensors to integrate with AHU having min. length of 2.5m and extension capability of 20m. The AHU Control box shall be capable to handle ambient temp. of range –10°C and 40°C. The AHU Control Box shall be capable to operate on 220V 50Hz.For following AHU capacity.
AHU Tag Name / Area / Location of AHU / Flow in CFM (Type) / Cooling Load (TR) / Coil Rows / Filters / External Static Pre.(MM) / Motor (Kw)
FM-AHU-1 / Attrium cum reception and waiting / Ground floor / 5000CFM / FM / 14.0TR / 6 ROWs / 10µ / 15-20 MM / 2.2kws
FM-AHU-2/ Attrium cum reception and waiting / First floor / 5000CFM / FM / 14.0TR / 6 ROWs / 10µ / 15-20 MM / 2.2kws
Drain Pipes Of AHUs, FCU & Cassette Unit :
Supplying, laying, fixing, testing of Rigid PVC Pipes pipes of 6 kg/sqcm, duly insulated with 9 mm Thick Nirtile rubber pipe section, complete with all necessary fittings such as elbows, tees, reducers, serviceable 'P' traps. etc and supports such as clamps etc complete as per specifications
50mm dia
40mm dia
32mm dia
25mm dia
AIR DISTRIBUTION SYSTEM:
G.I. Sheet Metal Duct Work As Per SMACNA Ducting Standards
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metalrectangular/round ducts of following thickness including RTV Sealent necessary supports, hangers, nut & bolts, neoprene rubber gaskets, splitter dampers, vanes, Double Canvass Connections, Fresh Air Intakes, Cowl with bird sceens also Air balancing / Air Adjustement as per design requirements etc complete as per specifications in accordance with the approved shop drawing. As Per SMACNA Ducting Standards.
For Ducts with external SP upto 250 Pa ( ESP upto 25mmWg)
Maximum Duct Size / Gauge / Joint Type / Bracing Spacing
1–500 mm / 26G / C&S Connector / Nil
501 – 750 mm / 26G / C&S Connector / Nil
751 – 900 mm / 24G / TDF Flange / Nil
901 – 1200 mm / 24G / TDF Flange / Nil
2101 – above / 18G / TDF Flange -MS angle Flange/ JTR or ZEE BAR (Also for Transition Duct piece for axial fan mouth)
Self acting dampers/Back draught Damper
Supply, installation, testing of Self acting dampers/Back draught Damper as per approved shop drawings.Self acting /Back draught type Damper is a Non-Return damper intended to be used in a mechanical system. With fan Running, the degree of blade opening is a function of the air velocity. If the fan is turned off, the blades close automatically.The blades are fitted in free running nylon bushes to operate at minimum pressure with each blade having a neoprene seal at edge for sealing. Sample to be submitted for prior approval.
Circular / Round for Above fans with Bird screen
FRESH/EXHAUST AIR LOUVER: Supply, installation and testing of opposed blades fresh/Exhaust air of inlet/outlet louvers, bird screen with M.S. Powder coated / Aluminum Frame to be 20 Gauge, Louver Blade 22 / 24 Gauges With approved shop drawings and specifications.(In Civil Scope)
Providing and fixing M.S. structural support with duly black painted with synthetic epoxy paint For axail fan. Approved Makes : -Tata, Jindal
MOTOR CONTROL CENTRE PANEL WITH PLC CUM MASTER LOGIC CONTROLLER:
Supply, installation, testing & commissioning of MCC Electrical Panel made out of 2/1.6 mm CRCA sheet finished with Siemens Grey powder coated painting and degree of protection . Panel complete with Built in PLC, MCB/MPCB Feeders and Starters for Jet Impulse fans with dual speed, Parking Exhaust air Axial fans with VFD and Emergency Exhaust air Fan with DOL startar. All Jet Impulse Fans and Parking Exhaust air Fans controlled through CO level feedback by individual MCC Panel's PLC and all Emergency Exhaust air axial fans shall also be runat costand speed in case of Receipt of FIRE SIGNAL from the Fire Basement Panel which supplied by other. All panels shall be floor mounted and top cable entry, suitable incomer MCCB, aluminum bus bar and custom built microprocessor logic controller with necessary control wiring etc. Each feeder shall have TPN MCB, two starters and indication lamps, toggle switch for two speed operations and PLC logic controller with necessary internal control wiring etc. All Fans Starter unto 7.0 Kw Shall be DOL & above 7. 0KW shall be STAR DELTA only NOTE :- If any changes in electrical power load of equipments for same capacity of fan then also do changes in panels as per same.
MCC Panel for Basement 1 WITH BUILT-IN PLC & SINGLE MLC for Basement-1
MCC Panel for Basement 1 WITH BUILT-IN PLC & SINGLE MLC for Basement-2
Under Roof Insulation
Under deck Insulation for exposed slab with 25 to 30 MM Thk Pre-Insulated PIR Panel with Washers, G.I. Crossed 50 mm wide patty, Joints selaed with Hot / Cold Bitumen etc .As Specified. Density of insulation shall be 48 ± 2 KG/m3. one side (outer side) shall be with aluminium foil & one side (inner side) shall be crfat paper. Thermal Conductivity of insulation shall be 0.021 (W/m⁰K). Insulation shall be Fire Classification with BS 476 Class O, Part 6&7.
Refrigerant for VRV/VRF System:-
Supply, filling, Testing & Commissioning charges along with topping-up of refrigerant for VRV/VRF
Double Skin Scrubber ( Water Spray Type Air Washer)
Supply of package type Scrubber shall consist of SISW centrifugal blowers, with forward curved blades, complete with TEFC drive motor of 415+ 10% volts, 3 phase, 50Hz, mounted on common base frame with metallistic vibration isolators. Fan shall be drive by motor through drive pulleys & belts with belt guard. The units shall be provided plenum connection for section mouth & outlet mouth cowl with bird screen. Units shall have flexible canvas connection at fan outlet. Access door shall be provided in fan section. All components shall be enclosed in 6mm preplasticised / powder coated GSS Double Skin casing duly reinforced. Water basin shall be of 18Ga stainless steel with 250mm tank depth . Other accessories like, pump, valves, distribution headers, pipes, trays, strainers etc shall be provided with the unit. PVC eliminators may be provided to eliminate carryover. The units shall have sturdy frame work, duly weather protected. The units shall be complete with GI ‘B’ class ( or UPVC pipe of 10kg/cm2 rating) and float valves, suction screen etc. The complete unit shall be mounted on sturdy weather protected unit base.all as per specifications and drawings. (The bidder shall submit fan performance curves for all fans)
4000CFM With 65 mm ESP
Double Skin Air Washer (Pad Type) :-
Supply, installation, testing & commissioning of package type Air washer having cellulose fill wetting media of minimum 90% wetting efficiency. The air washer shall consist of DIDW centrifugal blowers, with forward curved blades, complete with TEFC drive motor of 415+ 10% volts, 3 phase, 50Hz, mounted on common base frame with metallistic vibration isolators. Fan shall be drive by motor through drive pulleys & belts with belt guard. The units shall be provided with filter section with pre-filters. Units shall have flexible canvas connection at fan outlet. Access door shall be provided in fan section. Al components shall be enclosed in .6mm preplasticised / powder coated GSS Double Skin casing duly reinforced. Water basin shall be of 18Ga stainless steel & Depth of tank should be 250mm . Other accessories like, pump, valves, distribution headers, pipes, trays, strainers etc shall be provided with the unit. Cellulose fill shall be minimum 200 mm thick. PVC eliminators may be provided to eliminate carryover. The units shall have sturdy frame work, duly weather protected. Aluminium VCD shall be provided at fan discharge. The units shall be complete with GI ‘B’ class ( or UPVC pipe of 10kg/cm2 rating) and float valves, suction screen etc. The complete unit shall be mounted on sturdy weather protected unit base, all as per specifications and drawings. (The bidder shall submit fan performance curves for all fans)
3500CFM With 20 mm ESP
Section D HVAC Cost Cost Including all Taxes & duties in Rs.
Transformers:-
Supplying, installation, testing and commissioning 3 phase, 22/0.433 kV, 50 Hz., 1000 kVA, indoor type, vaccum cast coil (VCC) dry type cast resin transformer, copper wound , Dyn11 vector group, with delta connection on HV side & star connection on LV side with additional neutral brought out on load side, for indoor use continuous duty, average temp rise of winding (at principal tap) 115°C at ambient temp max 50°C & Min -5°C at full load rating, with tapping (with off circuit bolted links type tap changer) for off load +5 to - 5% @ 2.5% in +2/-2 Steps, HV variation, class of insulation H/H, method of cooling AN, no load loss at rated voltage & frequency (+15% IS Tol) 3.20 kW, full load loss at rated current 9.30 kW, with 98.77 % efficiency at full load & 98.91 % at 1/2 full load, with 125 KV peak full wave lightning impulse withstand voltage with complete enclosure having IP 23 degree of protection, cable box arrangement at HV side & bus duct at LV side ,with rating & diagram plate, base channel, lifting lugs, earthling terminals & WTI scanner with 3 PT-100 sensors, etc. standard accessories complete with test certificate (as per IS:11171 & IEC 60076-11) with necessary permissions of Electrical Inspector, as per specification no. SS- TR.
H.T METERING:-
Supplying, erecting, testing, commissioning 22 KV HT metering cubical (compact type) approved by MSEDCL/licensee fabricated with 2mm.(14 SWG) M.S. sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25x6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( CT,PT cover) interlock with meter doors, epoxy coated 3 nos CT having required ratio between 50/5 A to 100/5 A, VA10, class 0.2S, 22000/V3/110/V3 VA 50, class 0.2 epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc. complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation
HT SF6 Load Break Switch /VCB/RMU (SW-HTS):-
Supplying , erecting, testing & commissioning SF 6 Insulated 22kV, 630A, 16kA/3sec, 1 way outdoor, extensible motorised SCADA compatible RMU as per electric supply company specification consisting of 1 no. feeder with VCB as per specification no. SW-HTS / RMU SCADA (1VCB)
Generators (GEN-GEN):-
Supplying, erecting and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of above 400 kVA upto 500 kVA capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
CONTROL PANEL (CP):-
Supplying and erecting 200 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP /APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 400 mm width & 100 mm height comprising all required standard accessories.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Earthing:-
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws in an approved manner.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall with insulating and non-corrosive bond in an approved manner with required joints. As per specification no. EA-EP.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond in an approved manner with required joints As per specification no. EA-EP.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner.
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & erecting mains with 4x6 sq.mm. FRLSH copper wire, in 16gauge 25 mm dia. rigid steel conduit, with continuous GI earth wire of 4sq.mm. as per specification No: WG-MA/MC.
Point wiring for independent plug, concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WG-PW/SW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
ELECTRICAL:-
Supply, Installation, Testing and commissioning of floor Mounted GI Raceways of 200mmX38mm x2mm .Including all bends, Joints, Cover Sheet, End Caps, External Angles, Internal Angles, Flat Angles, Flat Junctions, Flat Tee, Flat Cross, Clips, Separation Partition etc.
Supply, Installation, Testing and commissioning of floor Mounted GI Raceways of 250mmX38mmx2mm .Including all bends, Joints, Cover Sheet, End Caps, External Angles, Internal Angles, Flat Angles, Flat Junctions, Flat Tee, Flat Cross, Clips, Separation Partition etc.
Supply, Installation, Testing and commissioning of floor Mounted GI Raceways of 300mmX38mmx2mm .Including all bends, Joints, Cover Sheet, End Caps, External Angles, Internal Angles, Flat Angles, Flat Junctions, Flat Tee, Flat Cross, Clips, Separation Partition etc.
Supply, Installation, Testing and commissioning of 100 x 100mm Floor Junction Box made up of GI with 2 MM sheet gauge
Supply, Installation, Testing and commissioning of 150 x 150mm Floor Junction Box made up of GI with 2 MM sheet gauge
Supply, Installation, Testing and commissioning of 200 x 200mm Floor Junction Box made up of GI with 2 MM sheet gauge
Supply, Installation, Testing and commissioning of 250 x 250mm Floor Junction Box made up of GI with 2 MM sheet gauge
Supply, Installation, Testing and commissioning of 300 x 300mm Floor Junction Box made up of GI with 2 MM sheet gauge
Supply, Installation, Testing and commissioning of 350 x 350mm Floor Junction Box made up of GI with 2 MM sheet gauge
Section E Electrical works Including all Taxes & duties in Rs.
Shubham EPC Private Limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .