| 1 | L1₹19.9 LAccepted-AOC | ₹19.9 L Quoted ₹20.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹20.8 L+₹32,865 (1.61%)Rejected-Finance H NO 374 1 BUILDING I AQUEM PLAZA TF F4 OPP DEVKI STEEL AQUEM BAXIO MARGAO GOA 403707 | MARGAO | SOUTH GOA | GOA | 403707 | ₹20.8 L+₹32,865 (1.61%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹21.0 L+₹58,076 (2.84%)Rejected-Finance | ₹21.0 L+₹58,076 (2.84%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹22.4 L+₹2.0 L (9.72%)Rejected-Finance | ₹22.4 L+₹2.0 L (9.72%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹23.6 L+₹3.1 L (15.3%)Rejected-Finance | ₹23.6 L+₹3.1 L (15.3%) | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Dhanu Refrigeration L3 | M/s Harshal Traders L4 | PREETI ENTERPRISES L1 | N P ENGINEERINGS L2 | Shriyansh sales and services L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/ aluminium point wiring of light, fan, socket 5/15Amps or power point complete including fittings such as switches, ceiling rose, pendant, regulator, socket, lamp holders, brackets, lamp fittings, tube light fittings etc including switch boards/sunken box and making good the disturbed of wall/ceiling/floors etc so as to match with the existing surface complete all as specified and as directed. | 585 | Point | 30 ₹17,550 | 10 ₹5,850 Lowest | 30 ₹17,550 | 80 ₹46,800 | 15 ₹8,775 |
| 2.00Material and labour for point wiring for one light point controlled by one way switch complete with 1100Volts grade 1.50 Sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories and fixing on wall/ ceiling including PVC board with cover (ISI marked) for mounting switches, sockets, regulators etc and providing one run of 1.5 sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable as earth continuity wire and connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and directed. | ||||||||
| 2.10 | For one light point controllled by one switch | 80 | Point | 450 ₹36,000 Lowest | 600 ₹48,000 | 750 ₹60,000 | 500 ₹40,000 | 540 ₹43,200 |
| 2.20 | For one ceiling fan point controllled by one switch | 30 | Point | 450 ₹13,500 Lowest | 600 ₹18,000 | 750 ₹22,500 | 500 ₹15,000 | 540 ₹16,200 |
| 2.30 | For one exhaust fan point controllled by one switch | 40 | Point | 450 ₹18,000 Lowest | 660 ₹26,400 | 750 ₹30,000 | 600 ₹24,000 | 600 ₹24,000 |
| 2.40 | For one bell point controlled by one switch | 20 | Point | 450 ₹9,000 Lowest | 660 ₹13,200 | 750 ₹15,000 | 610 ₹12,200 | 600 ₹12,000 |
| 2.50 | For one 5 Amp independent socket point controlled by one switch | 150 | Point | 611 ₹91,650 | 660 ₹99,000 | 750 ₹1,12,500 | 250 ₹37,500 Lowest | 600 ₹90,000 |
| 2.60 | For one 5 Amp socket point controlled by one switch on same board | 60 | Point | 190 ₹11,400 | 150 ₹9,000 Lowest | 380 ₹22,800 | 340 ₹20,400 | 180 ₹10,800 |
| 2.70 | for one light point Controlled by two 2-way Switch | 15 | Point | 666 ₹9,990 | 660 ₹9,900 | 750 ₹11,250 | 600 ₹9,000 Lowest | 630 ₹9,450 |
| 3.00M & L for point wiring complete with and including single core PVC, FRLSH, insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn thorough and iincluding heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceilling including all conduit accessories/fittings/junction boxes/inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 SWG pressed steel housing totally concealed in walls with 3 mm thick industrial laminated sheet top cover fixed flush with wall surface by means of brass screws and sunk/cupwashers for mounting of switches,sockets fan regulators etc including 1.5 Sqmm (22/0.30 mm ) 1100 Volts grade PVC, FRLSH insulated unsheathed flexiable multi stranded copper conductor cable as continuous earth wire connected to metallic bodies of luminaires/fans etc at one end and to common earth dolly at other end all as specified directed | ||||||||
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
28 Aug 2025, 6:00 pmClosed
GE PANAJI
OPPOSITE KALA ACADEMY ST INEZ ROAD PANAJI GOA 403001
REPAIR REPLACEMENT OF INTERNAL WIRING SUBMAIN WIRING LIGHT FITTINGS DBS AND OTHER ALLIED WORKS AT ASC MADGAON AND PONDA AREAS UNDER GE PANAJI
2025_MES_723635_1
8247/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE PANAJI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER PANAJI
₹50,000
Yes
4 Oct 2025
31 Jul 2025
4 Sept 2025
31 Jul 2025
28 Aug 2025
14 Aug 2025
31 Jul 2025 - 7 Aug 2025
Amount
Taking down carefully copper/ aluminium point wiring of light, fan, socket 5/15Amps or power point complete including fittings such as switches, ceiling rose, pendant, regulator, socket, lamp holders, brackets, lamp fittings, tube light fittings etc including switch boards/sunken box and making good the disturbed of wall/ceiling/floors etc so as to match with the existing surface complete all as specified and as directed.
Material and labour for point wiring for one light point controlled by one way switch complete with 1100Volts grade 1.50 Sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories and fixing on wall/ ceiling including PVC board with cover (ISI marked) for mounting switches, sockets, regulators etc and providing one run of 1.5 sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable as earth continuity wire and connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and directed.
For one light point controllled by one switch
For one ceiling fan point controllled by one switch
For one exhaust fan point controllled by one switch
For one bell point controlled by one switch
For one 5 Amp independent socket point controlled by one switch
For one 5 Amp socket point controlled by one switch on same board
for one light point Controlled by two 2-way Switch
M & L for point wiring complete with and including single core PVC, FRLSH, insulated unsheathed flexible bright annealed multi stranded copper conductor cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn thorough and iincluding heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ceilling including all conduit accessories/fittings/junction boxes/inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of factory made 16 SWG pressed steel housing totally concealed in walls with 3 mm thick industrial laminated sheet top cover fixed flush with wall surface by means of brass screws and sunk/cupwashers for mounting of switches,sockets fan regulators etc including 1.5 Sqmm (22/0.30 mm ) 1100 Volts grade PVC, FRLSH insulated unsheathed flexiable multi stranded copper conductor cable as continuous earth wire connected to metallic bodies of luminaires/fans etc at one end and to common earth dolly at other end all as specified directed
For one light point controllled by one switch
For one ceiling fan point controllled by one switch
For one exhaust fan point controllled by one switch
For one bell point controlled by one switch
One 6A, 5 pin socket outlet point on same board with other switches including earth wire and connected to common earth and earth terminal
One 6A, 5 pin socket outlet point on independent board with including earth wire and connected to common earth and earth terminals
One 16A 5 pin switch/socket out let point on independent board but cable of size 2.5 sqmm and earth cable of size 2.5 sqmm and connected to common earth and earth terminals.
All as per here and before item No-3 above but Concealed wiring in Existing Conduit for light/fan
All as per here and before item No-3 above but for one light point controlled by two 2-way switch for light/fan
Material and labour for point wiring for 15Amp independent socket point controlled by one switch complete with 1100 Volts grade 2.50 Sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories and fixing on wall/ ceiling including PVC board with cover (ISI marked) for mounting switches, sockets, regulators etc and providing one run of 2.5 sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable as earth continuity wire and connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of peris/ putti complete all as specified and directed.
Supply and fix in repair switch flush type, single pole, one way, 6Amps, 240 Volts, white finish complete all as specified
S & F in repairs stepped type electronic fan regulator flush type 1 Module on the existing phenolic laminated sheet etc. as reqd
Supply and fix in repairs switch flush type 16Amps, 240 Volts, single pole white finish complete all as specified and directed.
Supply and fix in repairs bell push, 5Amps, 240 Volts white finish complete all as specified
Supply and fix in repairs socket outlet, 5 pin, 6 Amps, flush type, white finish complete all as specified
Supply and fix in repairs socket outlet, 2 in1, 3 pin, 6/16 Amps, flush type universal, 240 Volt, white finish complete all as specified
Taking down & Refixing in repairs switch flush type, single pole, one way, 6Amps, 240 Volts, white finish complete all as specified
Taking down & Refixing in repairs switch flush type 16Amps, 240 Volts, single pole white finish complete all as specified and directed.
Taking down & Refixing in repairs bell push, 5Amps, 240 Volts white finish complete all as specified
Taking down & Refixing in repairs socket outlet, 5 pin, 6 Amps, flush type, white finish complete all as specified
Taking down & Refixing in repairs socket outlet, 2 in1, 3 pin, 6/16 Amps, flush type universal, 240 Volt, white finish complete all as specified
Taking down & Refixing in repairs electronic socket size, rotary, 5 speed step type regulator, 220-230Volts, and white finish complete all as specified
Taking down & Refixing in repairs call bell, ding dong type, AC 230 Volts single pole
Taking down & Refixing in repairs lamp holder insulated body with back plate suitable for angle/ batten fitting complete all as specified
S & F in repair Modular switch 1 way 6A, 1 module complete all as specified
S & F in repair Modular switch 1 way 16A, 1 module complete all as specified
S & F in repair Modular Bell push 6A 1 module complete all as specified
S & F in repair Socket, 6A - 2/3 pin combined 2 module complete all as specified
S & F in reapir Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified
S & F in repair Modular Fan step regulator, 120W - 2 module complete all as specified
S & F in repair White cover plate with frame,1 module complete all as specified
S & F in repair White cover plate with frame, 2 module complete all as specified
S & F in repair White cover plate with frame, 3 module complete all as specified
S & F in repair White cover plate with frame, 4 module complete all as specified
S & F in repair White cover plate with frame, 6 module complete all as specified
Taking down carefully sub main wiring including aluminium conductor of any size / GI earth continuity conductor and making good disturbed surface all as directed.
M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 6 Sqmm and one run of 6 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire as earth wire to be drawn in and including white/ ivory colour heavy duty PVC casing/ capping with accessories and fixing on wall/ ceiling Including wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.Note : Two runs of 6 Sqmm copper wire,one run of 6 Sqmm earth wire & one run PVC Conduit shall be measured as one unit
M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 1.5 Sqmm and one run of 1.5 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire as earth wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.Note : Two runs of 1.5 Sqmm copper wire,one run of 1.5 Sqmm Earth wire & one run PVC Conduit shall be measured as one unit
M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 2.5 Sqmm and one run of 2.5 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire as earth wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.Note : Two runs of 2.5 Sqmm copper wire,one run of 2.5 Sqmm earth wire & one run PVC Conduit shall be measured as one unit
M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4 Sqmm and one run of 4 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire as earth wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.Note : Two runs of 4 Sqmm copper wire,one run of 4 Sqmm earth wire & one run PVC Conduit shall be measured as one unit
M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 6 Sqmm and one run of 6 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire as earth wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.Note : Two runs of 6 Sqmm copper wire,one run of 6 Sqmm earth wire & one run PVC Conduit shall be measured as one unit
M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 6 Sqmm and one run of 6 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire as earth wire to be drawn in Existing PVC Conduit in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.Note : Two runs of 6 Sqmm copper wire,one run of 6 Sqmm earth wire shall be measured as one unit
M&L Sub main wiring using two runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 10 Sqmm and one run of 10 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire as earth wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.Note : Two runs of 10 Sqmm copper wire,one run of 10 Sqmm earth wire & one run PVC Conduit shall be measured as one unit
M&L Sub main wiring using Four runs of FRLSH grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 10 Sqmm and one run of 10 Sqmm FRLSH grade PVC insulated, unsheathed, stranded, single core, copper wire as earth wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified.Note : Four runs of 10 Sqmm copper wire,one run of 10 Sqmm earth wire & one run PVC Conduit shall be measured as one unit
Taking down with dismantling old Main Switches/DB with MCBs all as specified and directed
S & F for Sheet Metal Enclosure MCB DB SPN 4 Way, IP 43,IK 09, with 100 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in Wall by cutting the brick/stone masonary etc & taking down of unsv DB and making good of disturbed surface to match with existing colour of wall complete all as specified and directed.Note:- The space left after inserting MCB should be properly filled with blanking plate
S & F for Sheet Metal Enclosure MCB DB SPN 6 Way, IP 43,IK 09, with 100 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in Wall by cutting the brick/stone masonary etc & taking down of unsv DB and making good of disturbed surface to match with existing colour of wall complete all as specified and directed.Note:- The space left after inserting MCB should be properly filled with blanking plate
S & F for Sheet Metal Enclosure MCB DB SPN 8 Way, IP 43,IK 09, with 200 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in Wall by cutting the brick/stone masonary etc & taking down of unsv DB and making good of disturbed surface to match with existing colour of wall complete all as specified and directed.Note:- The space left after inserting MCB should be properly filled with blanking plate
S & F for Sheet Metal Enclosure MCB DB SPN 12 Way, IP 43,IK 09, with 200 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in Wall by cutting the brick/stone masonary etc & taking down of unsv DB and making good of disturbed surface to match with existing colour of wall complete all as specified and directed.Note:- The space left after inserting MCB should be properly filled with blanking plate
S & F for Sheet Metal Enclosure MCB DB TPN 4 Way, IP 43,IK 09, Vertical Type with 200 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in Wall by cutting the brick/stone masonary etc & taking down of unsv DB and making good of disturbed surface to match with existing colour of wall complete all as specified and directed.Note:- The space left after inserting MCB should be properly filled with blanking plate
Supply and fix sheet metal enclosure double door, vertical type for DB’s when MCCB’s to be used as incomer including MCCB 100 Amp triple pole and neutral 4 ways IP 43,IK 09, 415 volts with 200amps rated bus bar fixed sunk/ flush to wall by cutting the brick/stone masonary etc & taking down of unsv DB and making good of disturbed surface to match with existing colour of wall complete all as specified and directed.Note:- The space left after inserting MCB should be properly filled with blanking plate
Supply and fix for MCB Single Pole rated capacity 6 to 32Amp,240 Volts10KA breaking capacity 10 KA , 'C' curve connected with suitable lugs complete all as specified and as directed.
Supply and fix for MCB Single Pole & neutral rated capacity 16 to 32Amp,240 Volts10KA breaking capacity 10 KA , 'C' curve connected with suitable lugs complete all as specified and as directed.
Supply and fix for MCB Triple Pole & neutral rated capacity 40 to 100Amp,415 Volts10KA breaking capacity 10 KA , 'C' curve connected with suitable lugs complete all as specified and as directed.
S&F PVC insulated, sheathed twin twisted stranded copper conductor flexible cable of size 1.5 Sqmm for Connection of light/fan
S & F Wall Mounted Fan 400 mm Sweep,Single Phase 230 Volts including flexible copper cable for electric Connections ,ISI marked complete all as specified and directed
Supply and fix energy efficient exhaust fan, 300m sweep made of metal body Ventil air -DS type complete with louvers with bolts nuts and washer size of the bolt 15 cm long 12 mm dia embaded inthe wall including provision of PVC flexible copper cable of size 23/0.0076 two core from celing rose to exhaust fan connection and making suitable size of hole to existing brick wall for fan base including writing the MES Number with synthetic enamel paint complete all as specified and directed .(Note: Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate qouted.
S & F for Ceiling fan ,230 Volts ,1200 mm Sweep with min air delivery 220 CFM, service Value of the fan shall be greater than 8.0 as per BIS with blades, down rod & other necessary accessories and electrical connections from ceiling rose to fan terminal without remote system with capacitive type fan regulator complete all as specified and as directed.
S & F in repairs modular surface mounted plastic boxes 3 module for fixing of switch socket combination 16 Amps ISI marked complete all as specified and as directed
S & F in repairs modular surface mounted plastic boxes 4 module for fixing of switches, sockets and regulators etc ISI marked complete all as specified and as directed
S & F in repairs modular surface mounted plastic boxes 6 module for fixing of switches, sockets and regulator etc ISI marked complete all as specified and as directed
S & F in repairs modular surface mounted plastic boxes 8 module for fixing of switches, sockets and regulator etc ISI marked complete all as specified and as directed
Material and labour for cutting/ boring of PCC hard standing at a depth not more than 15cm deep and 15cm in breadth for passing earthling conductor and making good the disturbed surfaces with PCC 1:2:4 type B-0 or cement mortar 1:3 complete all as specified and as directed.
Supply and fix GI pipe light grade of size 15 mm bore for laying in trenches/ floors or walls including all fittings as required complete all as specified and as directed.
Supply and fixing High-quality design LED Tube light fittings in extruded aluminium housing with high quality PC diffuser 1x20 watt with enhances safety and relible ,robust housing structure with efficiency of 120 lm/W ,decorative end caps complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
S&F LED Batten Tube Light light fittings 10 Watt and fixed with wall surface with anodized extruded aluminium housing, high transmissitivity diffuser and high lumin output and connecting with 3 core flexible copper cable PVC insulated complete all as specified and directed.
Supply and fixing for LED luminaire 600 mm x 600 mm, square LED Panel 36 Watt ,lumen output >= 110 lumen/watt , 220 V AC Ceiling mounted type with high effeciency PMMA diffuser soft glare free light complete with driver holder, LED lamp suitable for roof/false ceiling ,including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed by Eng-in- Charge
M & L for fixing AC Three phase static energy meter of accuracy class 1.0 ,415 volt , 50 Hz with backelit LCD display of rating 10 to 60 Amps and with 1 push button (measures and display KWH, KVAh,V, I, P.F) with transparent hinge type box (The company should provide a meter replacement warranty of 5 years) incl taking down of old unsv meter complete all as specified
M & L for fixing AC single phase static energy meter of accuracy class 1.0 ,240 volt , 50 Hz with backelit LCD display of rating 05 to 60 Amps and with 1 push button (measures and display KWH, KVAh,V, I, P.F) with transparent hinge type box (The company should provide a meter replacement warranty of 5 years) incl taking down of old unsv meter complete all as specified
Material and labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25metre deep below natural ground level) with top edge of the plate not less than 1.5metre below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to main switch board/ main DB’s/ earth test point with and including necessary excavation and earth work in any type of strata, PCC 1:3:6, type C1 in chamber wall with 50mm thick, RCC cover 1:2:4, type B0 duly reinforced with 6 mm dia bar, @100mm both way with suitable lifting handle, charcoal dust and common salt mixed and packed in 150mm thick layer all around the earth plate, watering pipe of size 20mm dia medium grade, 0.63mm thick GI sheet funnel with wire mesh, GI protection pipe 15mm dia light grade up to 7.5m from electrode and engraving of earth marking on nearby structure/ building with cement motor 1:4 plate of size 200mm x 150mm x 15mm thick and writing of earth results with paint complete all as shown in electrical plate No. 5 of SSR Part-I complete all as specified and as directed. Note: - On testing if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Material and labour for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/ pipe all as required at site complete all as specified and as directed.
N P ENGINEERINGS (BID ID -3401298)
Dhanu Refrigeration (BID ID -3400734)
M/s Harshal Traders (BID ID -3401323)
Shriyansh sales and services (BID ID -3401952)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .