| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.9 L+₹1.6 L (12.2%)Rejected-Finance | L2 | Rejected-Finance Higher | |
| 3 | L3₹15.1 L+₹1.8 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Higher | |
| 4 | L4₹15.6 L+₹2.3 L (17.4%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L4 | Rejected-Finance Higher | |
| 5 | L5₹15.7 L+₹2.4 L (18.2%)Rejected-Finance | L5 | Rejected-Finance Higher |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
9 Dec 2019, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Repair and maint of street light and security light at Zone-I area of Tibri Mil Stn under GE Gurdaspur.
2019_MES_294128_2
GE GSR-52/2019-20
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer, Gurdaspur (Tibri)
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹44,000
8 Jan 2020
19 Nov 2019
11 Dec 2019
19 Nov 2019
9 Dec 2019
4 Dec 2019
Amount
Dismantling/Taking down carefully by disconnecting of electric connection from any situation/location,place and deposting to MES store yard all as specified and directed by Engineer-in-Charge.Such as street light fittings 1 X 36/40 watts, HPSV/LED, HPMV of 70 to 400 watts,flood lights,post top lantern etc. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of LED street light 90 Watt with main housing made of pressure die casting with uniform thickness and proper heat sink design to ensure fast heat dissipation. The LEDs should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick transfer of heat to heat sink. This also ensure that LEDs should free from dust/ moisture/ water entry (IP 66) . The luminous efficacy should > 100 lumens/ watt and power factor > 0.95 and CCT 4000 K with permissable variation of +/- of 300 K operating voltage should be 100 volt to 300 volts with under and over voltage protection. In build surge protection should be more than 2 KV and external SPD should be of 10 KV capacity. The operating voltage should be 90V to 300 V with under voltage and over voltage protection.
Supply and fixing of LED street light 72 Watt with main housing made of pressure die casting with uniform thickness and proper heat sink design to ensure fast heat dissipation. The LEDs should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick transfer of heat to heat sink. This also ensure that LEDs should free from dust/ moisture/ water entry (IP 66) . The luminous efficacy should > 100 lumens/ watt and power factor > 0.95 and CCT 4000 K with permissable variation of +/- of 300 K operating voltage should be 100 volt to 300 volts with under and over voltage protection. In build surge protection should be more than 2 KV and external SPD should be of 10 KV capacity. The operating voltage should be 90V to 300 V with under voltage and over voltage protection.
Supply and fixing of LED street light 60 Watt with main housing made of pressure die casting with uniform thickness and proper heat sink design to ensure fast heat dissipation. The LEDs should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick transfer of heat to heat sink. This also ensure that LEDs should free from dust/ moisture/ water entry (IP 66) . The luminous efficacy should > 100 lumens/ watt and power factor > 0.95 and CCT 4000 K with permissable variation of +/- of 300 K operating voltage should be 100 volt to 300 volts with under and over voltage protection. In build surge protection should be more than 2 KV and external SPD should be of 10 KV capacity. The operating voltage should be 90V to 300 V with under voltage and over voltage protection.
Supply and fixing of LED street light 120 Watt with main housing made of pressure die casting with uniform thickness and proper heat sink design to ensure fast heat dissipation. The LEDs should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick transfer of heat to heat sink. This also ensure that LEDs should free from dust/ moisture/ water entry (IP 66) . The luminous efficacy should > 100 lumens/ watt and power factor > 0.95 and CCT 4000 K with permissable variation of +/- of 300 K operating voltage should be 100 volt to 300 volts with under and over voltage protection. In build surge protection should be more than 2 KV and external SPD should be of 10 KV capacity. The operating voltage should be 90V to 300 V with under voltage and over voltage protection.
S&F in repair LED Street light fitting driver of 90/100 Watt of any make as required at site all as specified and directed by Engineer-in-Charge of any size/any type.
S&F in repair LED Street light fitting driver of 70/72 Watt of any make as required at site all as specified and directed by Engineer-in-Charge of any size/any type.
S&F in repair LED Street light fitting driver of 60/30 Watt of any make as required at site all as specified and directed by Engineer-in-Charge of any size/any type.
Supply and fixing energy saving environmental friendly, long life , exclusive innovative die-cast aluminium IP 66 flood light with high power LEDs as light source , suitable for highlighting retails space 200 watt LED replacement metal halide flood light hoarding light luminaire complete all accessories ,connecting up with twin core twisted flexible copper conductor cable all as specified & directed by Engr-in-Charge. Make :- Wipro/ C&S/ Halonix/ Bajaj/CG/ Havells
Supply and fixing energy saving environmental friendly, long life , exclusive innovative die-cast aluminium IP 66 flood light with high power LEDs as light source , suitable for highlighting retails space 120 watt LED replacement metal halide flood light hoarding light luminaire complete all accessories ,connecting up with twin core twisted flexible copper conductor cable all as specified & directed by Engr-in-Charge. Make :- Wipro/ C&S/ Halonix/ Bajaj/CG/ Havells
Supply and fixing in replacement GI pipe bracket made out og GI pipe light grade 32/40mm dia and bend to shape 1.5 mtr long,MS clamps made out out of MS flat iron of size 40X4mm thick with nuts&bolts,washers complete including dismantling the existing GI pipe bracket and drilling of holes for nuts & bolts etc all as specified and directed by Engineer-in-Charge.
S&F in replacement Automatic Electromechanical street light timer switch complete in all respect consisting of time switch contactors one No. toggle switch 3 Nos kit kat or MCB's of appropriate cap and input and output terminals completely wired with a bakelite sheet with copper wires of suitable cap. Time switch and the unit should encased in weather proof MS sheet cabinet with lockable front and paint with one coat of anti corrosive solution one coat of red oxide primer and two coats of enameled paint (Synthetic) duly spray painted and provision for cable entry and attachment with the existing pedestal with following additional features :- (i) It should be suitable for outdoor installation and should be suitable dust /rain proof . (ii) It should operate within 5 minutes of the preset timings and should automatically switch off the faulty circuit. (iii) The time used in the switching unit should work for minimum 48 hours in case of failure of supply of the timer. (iv) There should be provision for manual operation during day time maintenance but without effecting the operation of pre set timings of switch. (v) It should have automatic phase change over facility of capacity three phase 110Amp 230 Volt. Make :- Electronics or Equivalent complete in panel box all as specified and directed
M&L for repair of the Timer panel switch of street lights including replacement of the following defective parts/ items, ligs, thimbles, copper/ aluminium wires, including made good by weldig/ brazing and painting of one coat of paint all as directed by Engineer-in-Charge.
Supply only analog type timer switches (without battery backup) front mounted programmable current capacity 15-16 amps with 1 change over all as directed.
Supply only digital type timer switches front mounted programmable per 1 mm, current capacity 15-16 amps with 1 change over, total 28 programes complete all as specified and directed.
Supply only MCCB 100 Amp, 3 Pole 50 Hz 16 KA complete all as specified and directed.
Supply only MCCB TPN 63 Amp, 3 Pole 50 Hz complete all as specified and directed.
Supply only 3 Pole power contractor of amp rating 30 to 50 Amps as per existing make and rating complete all as directed by Engineer-in-Charge. Make :- L&T/ Siemens/ Indusaian or equivalent.
Supply & fix in replacement of electric magnetic ballast 70watt consisting of high silicon steel lamination with argon welding super enamelled copper wire vacuum impregnated with white resin terminal block with tapping for 220/240 volts supplied suitable for,High Mast light of make of Bajaj or equivalent make of Surya/CG.
Supply and fixing in replacement of electric magnetic ballast 150 watt consisting of high silicon steel lamination with argon welding super enamelled copper wire vacuum impregnated with white resin terminal block with tapping for 220/240 volts supplied suitable for High Mast light complete all as specified and directed. Make of Bajaj or equivalent make of Surya/CG.
Supply and fixing in replacement of electric high pressure sodium vapour lamp tubular 70 watt make of Bajaj or equivalent make of Surya/CG.
Supply and fix high pressure sodium vapour lamp tubular 150 watt make of Bajaj or equivalent make of Surya/CG.
Supply and fixing of Igniter for HPSV/MH luminaries suitable for HPSV fitting 70/150/250 watt Make :- Bajaj/Surya/Philips.
Supply and fixing multi functional astro time clock switch all as specified and directed. Make :- Hager/ Schnieder/ Legrand/ Siements/ Ando asian/ HPL.
Supply and fixing in replacement LED post top lantern with die cast housing cum heat sink with PMMA diffuser in IP-66 fitting of 40 Watt. Make :- Wipro/ Philips/ GE/ Bajaj/ CG/ Havells.
Supply and fixing PVC cable multistranded aluminium conductor of size 6 sqmm 2 core all as specified and directed by Engineer-in-Charge. Make :- Polycab/ Havells/ HPL/ Finolex.
Supply and fixing PVC cable multistranded aluminium conductor of size 4 sqmm 2 core all as specified and directed by Engineer-in-Charge. Make :- Polycab/ Havells/ HPL/ Finolex.
S & F junction box polycorbonate with glass fibre reinforced , environment friendly, recylable, UV resistant , halogen and silicon free anti acid and anti corrosive IP 66/67 in accordance with IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar and one No. MCB SP 6A 10KA to control the street light including necessary clamps, nuts bolts to fix the junction box with poles all specified and directed.
Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade.
Supply and fixing shackle type insulator porcelain vitrous white, brown or green insulator incl galvanised mild steel straps washers insulators bolts washers of size 75x90 mm all as specified and directed.
M&L for earthing complete with galvansed steel earth plates electrode 600cm x 600cm x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with edge of the plate not less then 1.5 mtr below the ground level connection to GI galvanised iron strip 25 x 3mm as earthing lead by means of bolts/ nuts chick nut & washers of GI or steel all shown in electrical plate No 5 of SSR Part-I connection to feeder piller all as specified including watering GI pipe 40mm bore medium grade PCC chamber using PCC 1:3:6 type C1 cover funnel and wire mesh complete all as directed by Engineer-in-Charge.
M&L in replacement of surge protection device of capacity 1 KV for LED security lights complete all as specified and directed.
M&L in replacement of surge protection device of capacity 2 KV for LED security lights complete all as specified and directed.
M&L for preparation of old painted surfaces of electric pole covered by dust and other deposited materials by cleaning from steel tubular pole of length upto 9 metres cross arms , braceing, clamps etc and painting with one coat of aluminium paint retaining and repainting marking on pole and replacement of reflective band of RED - YELLOW - RED alternate coloured 3 numbers all as specified and directed by Engineer-in-Charge.
M&L for preparation of old cement based painted surfaces of RCC pole 9 to 11 Mtr height cleaning the dust and other deposited materials and painting with one coat of exterior weather coat paint of approved make and colour retaining and repainting marking on pole and replacement of reflective band of RED - YELLOW - RED alternate coloured 3 numbers all as specified and directed by Engineer-in-Charge.
M&L for fault detection in damaged UG cable by using cable fault detector/ locator vehicle mounted to a accuracy of 2 mtr for various location inside the Cantt Area of any size and type upto 1.1 KV including excavation and earthworki in any type of stratra of size 4 x 2 x 0.6 m to usually inspect/ repair the damaged cable when and where required and directed by Engineer-in-Charge. The cost of labour & material for make good the disturbed surface will included in the rate quoted by the contractor.
Re-Stringing of existing ACSR conductor of any size any type as required sag fixed on OH line incl unwindinding the conductor & insulators/cross Arms on poles properly binding with alumminum all as specified and directed.
M & L aluminium conductor steel reinforced (ACSR) over size of ferret/ weasels/ mink/ beaver etc fixing stretching and jumppering joining with aluminium wire complete all as specified.
M&L for crossarms in replacement , bracing, supports, clamps and back plates, fabricated from structural steel section including nut bolts washers including welding, bending , cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide all specified.
Repair/ tightening of end terminals of street light fitting of any size and capacity and repair the street lights having minor faults i.e loose connections, carbon deposition etc and made the light functional all as specified and directed.
M/S Vijay Punj Constructions
Harbhajan electric co
UNITED ENGINEERING CORPORATION
GORAYA AND CO
GULSHAN SINGH GHAI AND SON
kaushal builders
Santokh Singh and Associates
MAHESH KUMAR SINGLA CONTRACTOR
Sharma Electrical and Engineering Works
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .