Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.1 L+₹62,620 (2.28%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹29.5 L+₹2.1 L (7.50%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.3 L+₹3.8 L (14.0%)Rejected-Finance 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹32.7 L+₹5.2 L (19.0%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L5 | Rejected-Finance Being L5 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
21 May 2024, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF LT CABLE ELECTRICAL BREAKDOWN INCL FAULT DETECTION LOCALIZATION AND RECTIFICATION IN UG NETWORK AND OH CONDUCTOR SWITCH GEAR INCL CONNECTED ITEMS AREA AT WEST OF MG ROAD AND ADJOINING AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
2024_MES_651090_1
GE/EM/LKO/EXT(ELECT)/T-31 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹88,000
Yes
5 Jul 2024
25 Apr 2024
23 May 2024
25 Apr 2024
21 May 2024
9 May 2024
Amount
Deployment of manpower / tools / machinery etc for testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 Volt LT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed.
Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule. (d) Note:- Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown . In case the rep or contractor shall not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.
Material & Laying, jointing and testing in replacement of LT under ground electric power cable crossed linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 4 core, complete all as specified laid in trenches / laid under floor or fixed naked on walls / on poles / in ducts / in GI pipes etc. with and including MS Clamps, nuts , bolts, washers, alumunium thimble, ferrule complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks / tiles / block and pipe shall be measured and paid separately under appropriate items.
All as per Item No 02 but cable of size 16 Sqmm 4 core.
All as per Item No 02 but cable of size 25 Sqmm 4 core.
All as per Item No 02 but cable of size 35 Sqmm 3.5 core.
All as per Item No 02 but cable of size 50 Sqmm 3.5 core.
All as per Item No 02 but cable of size 70 Sqmm 3.5 core.
All as per Item No 02 but cable of size 95 Sqmm 3.5 core.
All as per Item No 02 but cable of size 120 Sqmm 3.5 core.
All as per Item No 02 but cable of size 185 Sqmm 3.5 core.
All as per Item No 02 but cable of size 240 Sqmm 3.5 core.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 sqmm XLPE armoured aluminium conductor .
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 95 sqmm XLPE armoured aluminium conductor
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 120 to 185 sqmm XLPE armoured aluminium conductor
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 240 sqmm XLPE armoured aluminium conductor
Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 80 mm bore pipe and making good both ends all specified and directed
Excavation in trenches in soft / Loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for dry river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
M&L for laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
Trimming and cutting of tree branches (not more than 25 mm girth) coming across 1100 Volt LT over head line and street light clearing the line around 2 m single / both sides and and disposal of branches from site exeeding 50 m and not exceeding 250 m from site complete all as directed by Engr-in-Charge. Note : - (i) Length of span is approx 35 to 45 RM. (ii) Due care is to be given while trimming / cutting the tree branches that there should no damage to over head line conductor / pole. In case due to any negligence, damage is caused to be make good / renewal by the contractor from his own resources and nothing extra is admissible. (iii) All Safety to labourer must be adhered by the contractor during trimming and cutting of tree branches.
Dismetling and taking down old / unsv ACSR conductor any size complete all as specified and directed.
S&F ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin / shackle insulators with aluminium binding wires and required jumpering connection all as dercted. Note :- Size of aluminium conductor as per site requirement will be directed by Engineer-in-Charge.
Dimentling and taking down old / unsv insulator of any type any size from pole / stay complete all as specified and directed.
S&F pin type insulator, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100 mm height and 65 mm dia for 1100 volts grade all as specified and directed.
S&F shackle type insulator, porcelian vitreous white, brown or green insulator including galvanised mild steel straps, washers, insulators bolts, washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
S&F Loop type insulator, porcelian vitreous brown of size 65 x 90 mm and clearence hole 16 mm all as specified and directed.
Deployment of manpower / tools / machinery etc for restringing of existing loose over head line having 5 Nos ACSR conductor of any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge.
Deployment of manpower / tools / machinery etc for restringing of existing loose over head line having 2 Nos ACSR conductor of any size / type etc of existing LT pole including replacement of aluminium binding wire or suitable size carefully without damaging of insulator etc. complete all as specified and as directed by Engineer-in-Charge.
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
Material and labour disconnecting faulty / burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty / burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.
S&F in replacement wheather proof pole mounting PVC junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10 Amp -1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer Complete all as directed by Engr-in-Charge
S&F MCCB 63 Amps 4 Pole, 25 KA, 415 V, 50 Hz with thermal magnetic setting between 70% to 100% adjustable type including spreder and connected accessories and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
All as per item No 34 here in before but MCCB 100 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 34 here in before but MCCB 125 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 34 here in before but MCCB 160 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 34 here in before but MCCB 200 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 34 here in before but MCCB 250 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 34 here in before but MCCB 400 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 34 here in before but MCCB 600 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
S&F Isolator 63 Amps 4 Pole, 240 / 415 V, 50 Hz connecting up in the existing panel location including taking out existing unserviceable isolator complete all as specified and as directed by Engineer-in-Charge.
S&F Isolator 100 Amps 4 Pole, 240 / 415 V, 50 Hz connecting up in the existing panel location including taking out existing unserviceable isolator complete all as specified and as directed by Engineer-in-Charge.
Supply and laying in trenches / Floor / road crossing or fixed to Pole / Wall GI pipe light grade ISI marked with fitting of size 40 mm bore for protection of cable including taking down existing pipe complete all as specified and directed by the Engineer-in-Charge.
Supply and laying in trenches / Floor / road crossing or fixed to Pole / Wall GI pipe light grade ISI marked with fitting of size 50 mm bore for protection of cable including taking down existing pipe complete all as specified and directed by the Engineer-in-Charge.
Supply and laying in trenches / Floor / road crossing or fixed to Pole / Wall GI pipe light grade ISI marked with fitting of size 80 mm bore for protection of cable including taking down existing pipe complete all as specified and directed by the Engineer-in-Charge.
Supply and laying in trenches / Floor / road crossing or fixed to Pole / Wall GI pipe light grade ISI marked with fitting of size 100 mm bore for protection of cable including taking down existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for cutting of PCC / Hard standing / WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by providingPCC (1:3:6) type C-1 complete all as specified and directed .
S&F in repair 1100 volts grade heavy duty twin core cable PVC insulated with stranded aluminium conductor of size 6 sqmm and overall PVC sheathed in service connections from pole to pole and pole to junction box etc complete all as specified and as directed.
S&F On load change over switch, four pole with sheet metal enclouser advance neutral 200 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in the existing location including taking out existing unserviceable change over switch complete all as specified and as directed and as directed by Engineer-in-charge.
S&F in replacement out door type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm), CPRI approved, confirming to IS 5039, made out of 3.15 mm thick CRCA sheet and MS angle section 50 x 50 x 6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 400 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three. (d) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply and fix in replacement MCCB FP 200 Amps, 36 kA, 415 Volt AC, 50 Hz, complete with sheet metal enclosure of 1.6 mm thick MS sheet factory made with powder coat paint including connecting with existing system with existing cablling network including making good disturbed surfaces complete all as specified and directed. Note : The cost of suitable size fastner / Nut bolts required at site for fixing of cubical is deemed to be included in the quoted rate by the contractor.
M/s A.K Construction
Saurabh Enterprises
Eco Creations
Unnati Engineers
M/S SHIVA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .