| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 CrAdmitted-Finance | ₹5.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹5.4 CrAdmitted-Finance | ₹5.4 Cr | L2 | Admitted-Finance |
| 3 | L3₹5.7 CrAdmitted-Finance | ₹5.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹6.2 CrAdmitted-Finance | ₹6.2 Cr | L4 | Admitted-Finance |
| 5 | L5₹6.5 CrAdmitted-Finance | ₹6.5 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | S G TECHNOFAB PVT LTD L1 | SHUBH ENGINEERS L4 | CLIMATIC CONTROLS PVT LTD L3 | YUKON ENTERPRISES PVT LTD L5 | BRITE INDUSTRIES L7 | M/s Bhawani Air Systems L6 | DURACOOL AIRCONDITIONING L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00PART | ||||||||||
| 2.00 | PART - A : VRV - System | 1 | Nos | 4,74,08,718.4 ₹4.7 Cr | 5,35,66,320 ₹5.4 Cr | 4,76,96,481 ₹4.8 Cr | 5,40,18,099.1 ₹5.4 Cr | 4,59,55,028 ₹4.6 Cr | 5,86,28,216 ₹5.9 Cr | 4,33,61,395.1 ₹4.3 Cr |
| 3.00 | PART - B : Electrical works | 1 | Nos | 89,28,115.05 ₹89.3 L | 84,61,520 ₹84.6 L | 88,97,090 ₹89.0 L | 1,07,30,091.57 ₹1.1 Cr | 1,15,59,215 ₹1.2 Cr | 1,22,19,890 ₹1.2 Cr | 1,05,94,182.78 ₹1.1 Cr |
| 5.00 | PART - C : Electrical works in LCS-1 | 1 | Nos | 2,59,651.17 ₹2.6 L | 4,49,220 ₹4.5 L | 3,86,686 ₹3.9 L | 5,48,546.6 ₹5.5 L | 27,66,270 ₹27.7 L | 18,45,000 ₹18.4 L | 3,55,829 ₹3.6 L |
Tender Value
₹6.4 Cr
EMD Value
₹12.9 L
Closing Date
30 Dec 2025, 5:00 pmClosed
Chief Engineer (ESG)
DCSEM, 3rd floor, V.S. Bhavan, Anushaktinagar, Mumbai - 4000 094.
Supply, Installation, Testing and Commissioning of HVAC System for School of Computer and Mathematical Science Buildings At NISER, Bhubaneswar, Orissa.
2025_DCSEM_887910_1
DCSEM/CQD/QSC/NISER-VRV /NIT/11/25-26 dt 01.12.2025
Open Tender
Job Works
300 days
Bhubaneshwar, Orissa
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹12.9 L
5 Mar 2026
2 Dec 2025
1 Jan 2026
2 Dec 2025
30 Dec 2025
2 Dec 2025
2 Dec 2025 - 15 Dec 2025
Tender Inviting Authority:
Name of Work: Supply, Installation, Testing and Commissioning of HVAC System for School of Computer & Mathematical Science Buildings at NISER, Bhubaneswar, Orissa.
NIT No: No. 3.) 800/5A, Class-1, 15VA/30VA burden, Cast Resin Current Transformers – 3 Nos. 4.) RYB Indication Lamps (LED type) – 1 Set Note: Scope also include fixing of switchboard on wall with necessary accesories as required.
1) Bidders are requested to note that they should necessarily submit their financial bids in the format provided and no other format is acceptable. If the price bid has been given as a standard BoQ format with the tender document, then the same is to be downloaded and to be filled by all the bidders. Bidders are required to download the BoQ file, open it and complete the BLUE coloured (unprotected) cells with their respective financial quotes and other details (such as name of the bidder). No other cells should be changed. Once the details have been completed, the bidder should save it and submit it online, without changing the filename. If the BoQ file is found to be modified by the bidder, the bid will be rejected.
2) Bidders are advised to download this BOQ as it is and quote their offer/rates in the permitted column and upload the same in the commercial bid. Bidder shall not tamper/modify downloaded price bid template in any manner. In case if the same is found to be tempered/modified in any manner, tender will be completely rejected and EMD would be forefeited and tenderer is liable to be banned from doing business.
3) All the documents being submitted by the bidders would be encrypted using PKI encryption techniques to ensure the secrecy of the data. The data entered cannot be viewed by unauthorized persons until the time of bid opening. The confidentiality of the bids is maintained using the secured Socket Layer 128 bit encryption technology. Data storage encryption of sensitive fields is done. Any bid document that is uploaded to the server is subjected to symmetric encryption using a system generated symmetric key. Further this key is subjected to asymmetric encryption using buyers/bid opener’s public keys. Overall, the uploaded tender documents become readable only after the tender opening by the authorized bid openers.
Important Notes
I 1) The proposed work has to be carried out at School of Computer & Mathematical Science Buildings at NISER, Bhubaneswar, Orissa.
2) The tenderers are advised to visit the site to acquaint themselves regarding site conditions about the level of sub-soil water, drainage facility for dewatering, accessibility to the site etc., and quote the rates accordingly.
3) Vehicular movement shall abide by the regulations imposed by the concerned authorities. The contractor shall abide by the security rules & regulations of the Department. The approach roads should be kept clean & free from obstruction for smooth functioning.
4) The following security regulation shall be followed strictly while movement of labourers/workers/ contractor's personnel etc.
(i) The contractor shall issue I-Cards to his workers deployed on regular basis.
(ii) The supervisor of the contractor having photo pass can bring daily wage workers/ casual workers inside School of Computer & Mathematical Science Buildings at NISER, Bhubaneswar, Orissa for work. He should prepare list of such workers in duplicate. The original copy shall be handed over to the representative of the Engineer in Charge at the gate and endorsement obtained on the duplicate, on daily basis.
(iii) Contractor shall arrange for Police Verification Certificate (PVC) for permanent labour and supervisors on the work as required by Local Authorities.
(iv) The contractor's personnel including daily wage workers shall be in uniform with proper identification for ease in identification of such persons at unauthorised places.
(v) The daily wage workers/ casual workers employed by the contractor must wear florescence High-Visibility wear without fail during their presence inside School of Computer & Mathematical Science Buildings at NISER, Bhubaneswar, Orissa.
5) The contractor shall follow strictly the DAE safety rules .
6) The drawings issued for tender purpose are preliminary and indicative only. The working drawing shall be issued in phased manner at the time of execution. Nothing extra shall been entertained towards revision in drawings.
7) The contractor shall arrange water for construction purpose of his own.
8) Please refer pre bid query reply, if any.
9) Tenderers to quote rates inclusive of all taxes, duties, GST etc. as applicale.
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Chief Engineer (ESG)
Name of Work: Supply, Installation, Testing and Commissioning of HVAC System for School of Computer & Mathematical Science Buildings at NISER, Bhubaneswar, Orissa.
250A MCCB Switch- Fabrication, Supply, installation, testing & commissioning of 250 A Electrical Switchboard, powder-coated, wall-mounted, front-operated, front-access, cubicle type, totally enclosed, IP-42 protected, with hinged and lockable doors, fabricated from 2 mm thick CRCA MS sheet, including all interconnections, tinned copper crimping lugs, earthing/bonding, cable end boxes on both sides, suitable for 415 V, 3-phase, 4-wire, 50 Hz system and designed for 50 kA symmetrical fault level at 415 V, complete as per specifications, drawings and instructions of EIC, comprising the following: 1.) 250A, 4-Pole MCCB, 50 kA breaking capacity, microprocessor-based trip unit (as applicable), with extended rotary handle and ON/OFF/TRIP indication – 1 No. 2.) Multifunction Meter, 3-phase 4-wire, CT secondary 5A, Class-1, flush mounting 96×96 mm, indicating Voltage, Current, Frequency, PF, Power & Energy, similar to Model EM6436H of Schneider / equivalent – 1 No. 3.) 250/5A, Class-1, 10VA / 15VA burden, Cast Resin Current Transformers – 3 Nos. 4.) RYB Indication Lamps (LED type) – 1 Set Note: Scope also includes fixing of switchboard on wall with necessary accessories as required.
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 PART 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
2 PART - A : VRV - System 1 Nos Excess(+) Full Conversion INR
3 PART - B : Electrical works 1 Nos Excess(+) Full Conversion INR
5 PART - C : Electrical works in LCS-1 1 Nos Excess(+) Full Conversion INR
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Chief Engineer (ESG)
Name of Work: Supply, Installation, Testing and Commissioning of HVAC System for School of Computer & Mathematical Science Buildings at NISER, Bhubaneswar, Orissa.
250A MCCB Switch- Fabrication, Supply, installation, testing & commissioning of 250 A Electrical Switchboard, powder-coated, wall-mounted, front-operated, front-access, cubicle type, totally enclosed, IP-42 protected, with hinged and lockable doors, fabricated from 2 mm thick CRCA MS sheet, including all interconnections, tinned copper crimping lugs, earthing/bonding, cable end boxes on both sides, suitable for 415 V, 3-phase, 4-wire, 50 Hz system and designed for 50 kA symmetrical fault level at 415 V, complete as per specifications, drawings and instructions of EIC, comprising the following: 1.) 250A, 4-Pole MCCB, 50 kA breaking capacity, microprocessor-based trip unit (as applicable), with extended rotary handle and ON/OFF/TRIP indication – 1 No. 2.) Multifunction Meter, 3-phase 4-wire, CT secondary 5A, Class-1, flush mounting 96×96 mm, indicating Voltage, Current, Frequency, PF, Power & Energy, similar to Model EM6436H of Schneider / equivalent – 1 No. 3.) 250/5A, Class-1, 10VA / 15VA burden, Cast Resin Current Transformers – 3 Nos. 4.) RYB Indication Lamps (LED type) – 1 Set Note: Scope also includes fixing of switchboard on wall with necessary accessories as required.
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT TOTAL AMOUNT In Words
1 Outdoor units: Design, manufacturing, supply, installation, testing & commissioning of air cooled VRV outdoor units working on R-410 A/CFC Free refrigerant. The system shall be suitable to operate on 3 phase, 380-415 V, 50 Hz AC supply and shall comprise of all inverter based scroll compressors, confirming to the technical specification. The outdoor units of VRV system should be compatible with RoHS Directive. It should be compatible with all type of indoor units like cassettee units, Hi-wall units, False ceiling mounted units, TFA units, floor mounted units etc. The outdoor units should consist of VRV combination as per manufacturer std. air cooled condenser with each unit comprising 2 or 3 nos High COP Compressors of which all should be a Variable Speed Scroll compressor, condenser fans which have high external static Pressure of upto 78.4Pa with fan grill, fan motor & controls. The Outdoor units should also include microprocessor control panel, internal control and power wiring, internal interconnecting refrigerant pipes, charging ports, system required standard refrigerant charge, high efficiency heat exchange coil, oil separator, accumulator and all other required accessories, hardware’s shall be enclosed in a single enclosure(s). The entire unit shall have weather resistant powder coating paint for withstanding all ambient conditions for continuous operation and the units shall operate at lower noise levels of approx. 70 dB(A). It shall have ease of maintenance by incorporating Automatic Test Function, Memory Function for operational data and centrally controlled as per cooling zones.The system shall be compatible for microprocessor control by being connected with a separate corded central controller for each cooling zone or set of indoor units for informations and controls such as a) operating condition of indoor units, b) zone control, c) Malfunction code display, d) Airflow volume & direction control, e) Ventilation volume & mode control. It shall be further connectable with unified ON/OFF Controller, Schedule Timer and BMS System. This shall include all hardware and necessary inbuilt software’s complete in all respects as per the drawings. Note : 1) The VRF/VRV shall have incoming power MCCBs/ MCBs as per VRF/VRV unit control panels specifications. 2) The individual PCB should be microprocessor based as compatible for operation from remote controls with all hardwares, software and accessories complete in all respects. 3) Outdoor units shall be with anti-corrosion treatment and all nuts, bolts etc. shall be hot dip galvanizesd steel. 4) Testing, commissioning of VRV systems shall be included by the bidder in the scope of the work. All the consumables including refrigerant and oil for the proposed VRV system shall be under the scope of the bidder. The topping shall be done for any leakage during testing & commissioning of refrigerant (R-410 A/cfc free).
1.1 50 HP ODU 11 Set Excess(+) Full Conversion INR
1.2 40 HP ODU 2 Set Excess(+) Full Conversion INR
1.3 36 HP ODU 1 Set Excess(+) Full Conversion INR
1.4 32 HP ODU 2 Set Excess(+) Full Conversion INR
1.5 20 HP ODU 2 Set Excess(+) Full Conversion INR
2.1 Cassette type (4 way flow) units : Design, manufacturing, supply, installation, testing & commissioning of following air cooled VRF/VRV type all directional round flow DX split ceiling mounted cassette type indoor air conditioning unit of following capacity for mounting inside false ceiling confirming to the technical specification of VRF/VRV system and compatible with above Outdoor units. It should comprise of cooling coil, blower with multi speed motor, electronic expansion valve, supply & return air grilles, filters, insulated connection of refrigerant circuit, condensate water drain pump with electronic level sensor including cordless remote controllers & installation from ceiling with all required supports, anchor fastners hardwares, interconnecting refrigerant copper piping, support etc. All as per technical specifications and instructions of Engineer-in-charge and drawings.
2.11 1.28 TR 28 nos. Excess(+) Full Conversion INR
2.12 1.59 TR 38 nos. Excess(+) Full Conversion INR
2.13 2.0 TR 29 nos. Excess(+) Full Conversion INR
2.14 2.5 TR 59 nos. Excess(+) Full Conversion INR
2.15 3.2 TR 63 nos. Excess(+) Full Conversion INR
2.2 Outdoor Air Processing Units(TFA): Design, manufacture, supply, installation, testing & commissioning of air cooled VRF/VRV type Outdoor Air processing Treated Fresh Air units of 6.4 TR capacity with 1000 cfm conforming to the technical specification of VRF/VRV system and compatible with above Outdoor units where-in the IDU comprises of refrigerant DX cooling coil, electronic expansion valve, blower with multi speed motor, insulated connection of refrigerant circuit, filters, thermally insulated condensate water drain line, complete and suitable to operate from cordless/ corded remote controller including remote controller along with micro processor based PCB for operation of the indoor units and installation on the ceiling/floor with all required supports, anchor fasteners, hardwares with interconnecting copper piping, valves supports etc. suitable for operation with VRF/VRV system working on R 410 A/ cfc free refrigerant, all complete as per specification and as directed by EIC.The units shall be complete with elctrical connections and wiring. 6 nos. Excess(+) Full Conversion INR
2.3 Outdoor Air Handling Unit (AHU): Supply, installation, testing and commissioning of double skin type Air Handling Units suitable to work with VRV/F System having thermal break and complete with backward curved / aero foil type centrifugal fans, electric motor, DX cooling coil, drift eliminator, pre-filter, Extruded section Aluminium Volume Control damper ( both on suction & discharge side) mixing chambers,Starter Panel, control panel,cabling,controls etc. of following capacities & tonnage and as per of Technical Specification.
2.31 5000 CFM 32 TR 1 " Static NB : The cost of volume control damper is not to be included under this item as it shall be measured and paid under item no. 18. 2 nos. Excess(+) Full Conversion INR
2.4 Enclosure type Duct Mounted Exhaust Fan: Supply, Installation, Testing and Commissioning of duct mounte 2 nos Excess(+) Full Conversion INR
2.5 d exhaust blower of capacity 3000 CFM at 1 inch static along with SS bird screen, flexible metallic canvas connections, drive arrangement including required connections and all accessories, high efficiency TEFC Motor & Starter, control wiring, power cable terminations etc. as per drawings, technical specifications & instructions of Engineer-in-charge. 25 Volume Control Dampers: Supply, installation, testing and commissioning of manually operated heavy duty opposed blade type multilouvered damper with outer body frame and blades fabricated out of extruded Al section and aerofoil section respectively as per Technical Specification. Excess(+) Full Conversion INR
3 Grilles and Diffuser :Design, supply, installation, testing, commissioning and balancing of powder coated Aluminium extruded anodized grills, diffusers with double deflection louvers with volume control dampers for supply / return air all as per specifications & instructions of Engineer-in-charge. 4 sq.mtr Excess(+) Full Conversion INR
4 Central Remote controllers: Supply, installation, testing & commissioning of central remote controller as per specification corded controller for each coolig zone / floor to perform the following for Indoor units on each floor; A) Temperature of air in the room / area served by indoor units. B) Indication of no. of indoor and outdoor units working. C) ON/OFF condition of indoor units. D)Malfunction code display. E) Airflow volume & direction control. F) Ventillation volume & mode control. Provision of necessary UPS and cabling, etc, if any shall be included in the scope of the item.
4.1 Split Air-conditioner: Supply, installation, testing and commisioning (SITC) of ceiling suspended minimum 3 star rated Invertor Split AC of follwing nominal cooling capacities(Minimum) as per technical specifications and instructions of Engineer-in-Charge. Note: 1.The outdoor unit shall be provided with 10 mm thick neoprene pads. 2.The price is inclusive of consumables, leak testing, refrigent gas that may be required to put the air conditioner into service and no extra payment shall be made for the same. 3.The cutout for regrigerant pipe cable and drain shall be included in scope and no extra payment shall be made for the same. 2 set Excess(+) Full Conversion INR
4.2 2.5 TR capacity Cassette Split AC 4 set Excess(+) Full Conversion INR
5 2 TR capacity Cassette Split AC 250 EACH Excess(+) Full Conversion INR
6 Refrigerant joints: Supply, installation, testing & commissioning of refrigerant joints from VRF/VRV manufacturers for VRF/VRV system as per specifications and instruction of EIC. It should have minimum three connections (one inlet and two outlets). Each refrigerant joints sets should form combinedly of suction and discharge line i.e. two nos. of refrigerant joints per set. 12000 m Excess(+) Full Conversion INR
7 Communication cables: Supply, laying, testing & commissioning of standard copper 2C x 1.5 sq.mm screened sheilded communication cabling to have interface between outdoor units / controller to individual indoor units and covered into PVC conduit (HMS quality) to be laid on wall/false ceiling & covered ceiling including clamping and supporting as per standard specifications. 1000 m Excess(+) Full Conversion INR
8 Flexible pipe ducting : Supply, installation, testing & commisioning of 65 mm dia. Pre-insulated flexible pipe ducting as per standard specifications through 65mm dia GI sleeves installed in walls as per specifications, drawings and instruction of EIC.
8.1 GI Ducting: Design, supply, fabrication, installation, testing and commissioning of GI ducting of following sizes for supply from TFA, fresh air ducts and ventilation ducts complete with turning vanes, access doors, supports etc. as per drawing and specifications 1200 sets Excess(+) Full Conversion INR
8.2 i) 24 SWG 200 sets Excess(+) Full Conversion INR
8.3 ii) 22 SWG 200 sets Excess(+) Full Conversion INR
9.1 Insulation 1500 sets Excess(+) Full Conversion INR
9.2 Thermal Insulation: Supply, installation, testing & commissioning of Al foil faced 13mm nitrile rubber insulation class O for TFA ducting and fresh air ducting as per specification. The duct shall be pre cleaned before applying a thin film of manufacturers recommended adhesive. All joints shall be air tight and sealed with aluminmum tape. 100 sets Excess(+) Full Conversion INR
9.3 Acoustic Insulation: Supply,installation,testing & commissioning of 10mm thick acoustic insulation (armacell or equivalent quality open cell nitril rubber and specification) upto 6m from blower. 15 nos. Excess(+) Full Conversion INR
10 Canvas connection : Supply, installation, testing & commissioning of fire retardant (upto 250deg. C)flexible canvas connection along with zip for TFA units and exhaust air blower as per specification and instructions of EIC. 4 nos. Excess(+) Full Conversion INR
11 Fresh Air Connection: Design, supply, fabrication, installation of outdoor air connection made out of GSS, mounted over a wooden frame of required size with rain protection, bird screen Aluminium powder coated rain protection louver damper all as per standard specifications for treated fresh air units and fresh air ducts.
11.01 Refrigerant piping: Design, Supply, installation, testing & commissioning of the insulated refrigerant piping between outdoor unit to indoor units as per the manufacturer standard. The insulation shall be covered with fire-resistant/Class O fiber cloth fabric or woven glass fiber, resistant to scratches and mechanical impacts along the entire length of the suction refrigerant piping. The piping shall be laid in shaft, walls/roof/ceiling well supported at specific intervals with wooden batten / mettallic supports and screwed with anchor fasteners for the following sizes of refrigernat piping. The piping laid in open to sun light is to be provided with anti-sun rays coating and the pipes are to be covered with 22 SWG GI ducting suitably and with easy removal facility(Ducting shal be measured against respective item of this Schedule and paid separetely). All the refrigerant pipelines in terrace shall be installed on MS hot dip galvanized Tray. (GI Tray shal be measured against respective item of this Schedule and paid separetely). NB: 1) The sizes of pipes shown in the drawing are tentative only. The agency shall upon reward of tender work out the pipe sizing, in case of changes in pipe diameter as per calculations, the agency shall change the pipe sizes at site during installation at not extra cost to the department. 660 sq.m Excess(+) Full Conversion INR
11.02 Refrigerant Pipe of Size 6.4 mm 2200 sq.m Excess(+) Full Conversion INR
11.03 Refrigerant Pipe of Size 9.5 mm 1100 sq.m Excess(+) Full Conversion INR
11.04 Refrigerant Pipe of Size 12.7 mm 1800 sq.m Excess(+) Full Conversion INR
11.05 Refrigerant Pipe of Size 15.9 mm 730 sq.m Excess(+) Full Conversion INR
11.06 Refrigerant Pipe of Size 19.1 mm 500 sq.m Excess(+) Full Conversion INR
11.07 Refrigerant Pipe of Size 22.2 mm 30 sq.m Excess(+) Full Conversion INR
11.08 Refrigerant Pipe of Size 25.4 mm 900 sq.m Excess(+) Full Conversion INR
11.09 Refrigerant Pipe of Size 28.6 mm 50 sq.m Excess(+) Full Conversion INR
11.1 Refrigerant Pipe of Size 31.8 mm 200 sq.m Excess(+) Full Conversion INR
11.11 Refrigerant Pipe of Size 34.9 mm 20 sq.m Excess(+) Full Conversion INR
11.12 Refrigerant Pipe of Size 38.1 mm 250 sq.m Excess(+) Full Conversion INR
11.13 Refrigerant Pipe of Size 41.3 mm 20 sq.m Excess(+) Full Conversion INR
12 Refrigerant Pipe of Size 44.5 mm
12.1 Drain Piping: Design, supply, installation, testing & commissioning of drain piping consisting of hard UPVC pipes (pressure rating - 10kg/sq.cm) of following sizes insulated with 9mm nitrile rubber class O with necessary accessories and adequate supports as per drawings and specifications. 440 sq.m Excess(+) Full Conversion INR
12.2 25 mm 880 sq.m Excess(+) Full Conversion INR
12.3 32 mm 330 sq.m Excess(+) Full Conversion INR
12.4 40 mm 220 sq.m Excess(+) Full Conversion INR
12.5 50 mm 110 sq.m Excess(+) Full Conversion INR
13.1 GI Piping : Supply, gfabrication installation and comissioning of GI pipe sleeves of following sizes for refrigerant pipes, condensate drain pipes and flexible fresh air pipe ducts wherever pipes / pipe ducts pass through the beams and walls as per drawing and instruction of Engineer In Charge. 50 sq.m Excess(+) Full Conversion INR
13.2 50 mm 30 sq.m Excess(+) Full Conversion INR
14 100 mm 20 RMT Excess(+) Full Conversion INR
15 PCC Work : Providing PCC supports for Outdoor units of required sizes with cement morter 1:2:4 with curing etc., all complete as per specifications, drawings and as directed by E-I-C. 1500 kg Excess(+) Full Conversion INR
16 MS Structural Steel: SITC of MS structural steel includeing plates, flanges, angles, I beams etc. 6 Cum Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Chief Engineer (ESG)
Name of Work: Supply, Installation, Testing and Commissioning of HVAC System for School of Computer & Mathematical Science Buildings at NISER, Bhubaneswar, Orissa.
250A MCCB Switch- Fabrication, Supply, installation, testing & commissioning of 250 A Electrical Switchboard, powder-coated, wall-mounted, front-operated, front-access, cubicle type, totally enclosed, IP-42 protected, with hinged and lockable doors, fabricated from 2 mm thick CRCA MS sheet, including all interconnections, tinned copper crimping lugs, earthing/bonding, cable end boxes on both sides, suitable for 415 V, 3-phase, 4-wire, 50 Hz system and designed for 50 kA symmetrical fault level at 415 V, complete as per specifications, drawings and instructions of EIC, comprising the following: 1.) 250A, 4-Pole MCCB, 50 kA breaking capacity, microprocessor-based trip unit (as applicable), with extended rotary handle and ON/OFF/TRIP indication – 1 No. 2.) Multifunction Meter, 3-phase 4-wire, CT secondary 5A, Class-1, flush mounting 96×96 mm, indicating Voltage, Current, Frequency, PF, Power & Energy, similar to Model EM6436H of Schneider / equivalent – 1 No. 3.) 250/5A, Class-1, 10VA / 15VA burden, Cast Resin Current Transformers – 3 Nos. 4.) RYB Indication Lamps (LED type) – 1 Set Note: Scope also includes fixing of switchboard on wall with necessary accessories as required.
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT TOTAL AMOUNT In Words
1 No. 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
1.2 MAIN POWER PANEL for Zone K-S/6-12 & B-I/1-6: Supply, installation, testing & commissioning of floor-mounted, 1 25 x 3 mm Copper strip. Excess(+) Full Conversion INR
1.3 powder-coated, front-operated, cubicle type, totally enclosed Main Power Panel suitable for 415 V, 3-phase, 50 Hz system, designed for symmetrical fault level of 35 kA. Panel shall be fabricated from 2 mm thick CRCA sheet with hinged and lockable doors, IP-55 protection, fully finger-safe, with busbars insulated with heat shrinkable sleeves and supported on SMC/DMC supports. Incomer :- a) 1 No. 630 A, 4-pole MCCB, microprocessor-based trip unit with LSIG, electronic overcurrent, short-circuit & earth fault release, Type-II coordination as per IS 13947-4-1, with adjustable settings, extended padlockable rotary handle, shunt-trip facility b) 1 set of RYB indication lamps with HRC protection fusses. c) 3 nos 630/5 A Class-I, 15 VA burden cast resin current transformers for current monitoring – 1 set. d) 1 No. 0–500 V voltmeter, 96 sq.mm, with 3-way & off selector switch with HRC protection fusses. e) 1 No. 0–630 A ammeter, 96 sq.mm, with 3-way & off selector switch – 1 set. Bus bar:-630 A TPN tinned copper bus bar having maximum current density of 800 A/sq.inch to withstand symmetrical fault level of 35 KA at 415 V. The neutral bus bar shall have 100% capacity. Outgoings :- A) FOR ODU'S VTPN DB ( 6 SETS): 1) 125 A TPN microprocessor MCCB, microprocessor-based trip unit with LSIG, electronic trip (overcurrent, short-circuit & earth fault). 2) "ON" "OFF" Indication lamp - 1 set 3) 1 no.0-125 A , 96 sqmm ammeter with three way & off selector switch - 1 set 4) 3 nos 125/5 A ratio,class-I, 5 VA burden cast resin current transformer for current monitoring. - 1 set B) Distribution Board : a) 32 A TPN MCB – 2 No. b) 6 - 10 A TPN MCB - 04 nos. c) Brass neutral link. - as required. 18 Supply, installation, testing and commissioning of 63A, 415 V, 3-phase (TPN) MCB, 10 kA breaking capacity, housed in a suitable factory-made powder-coated MS enclosure (IP-42), including all accessories such as ferrules, interconnections, earthing, mounting hardware, including fixing on wall and making good the site complete as required and as per the direction of Engineer-in-Charge. Excess(+) Full Conversion INR
2 MAIN POWER PANEL for Zone B-K/6-16 Incomer :- a) 1 No. 400 A , 4-pole MCCB, microprocessor-based trip unit with LSIG, electronic overcurrent, short-circuit & earth fault release, Type-II coordination as per IS 13947-4-1, with adjustable settings, extended padlockable rotary handle, shunt-trip facility b) 1 set of RYB indication lamp with HRC protection fuses c) 3 nos 400/5 A ratio, Class-I 15 VA burden cast resin current transformer for current monitoring - 1 Set. d)1 No. 96 sqmm, 0-500V voltmeter with 3 way & off selector switch and HRC protection fuses. e) 1 no.96 sq.mm , 0-400 A ammeter with three way & off selector switch - 1 set Bus bar:- 400 A TPN tinned copper bus bar having maximum current density of 800 A/sq.inch to withstand symmetrical fault level of 35 KA at 415 V. The neutral bus bar shall have 100% capacity. Outgoings :- A) FOR ODU'S VTPN DB ( 4 SETS) 1) 125 A TPN microprocessor MCCB, microprocessor-based trip unit with LSIG, electronic trip (overcurrent, short-circuit & earth fault). 2) "ON" "OFF" Indication lamp - 1 set 3) 1 no.0-125 A , 96 sqmm ammeter with three way & off selector switch - 1 set 4) 3 nos 125/5 A ratio,class-I, 5 VA burden cast resin current transformer for current monitoring. - 1 set B) Distribution Board a) Incoming - 1 No. 125 A , 4-pole MCCB, microprocessor-based trip unit with LSIG, electronic overcurrent, short-circuit & earth fault release b) Outgoing - 32 A SPN MCB – 8 No.(6 for split Ac and 2 for spare) c) 6 - 10 A TPN MCB - 02 nos. d) Brass neutral link. - as required.
2.1 VTPN DB for ODUs: Supply, installation, testing & commissioning of a Readymade / Fabricated 4-way VTPN Distribution Board (IP-55 protected), complete with 2 Nos. cable end boxes, fully wired and ready for use, comprising the following components: 1.) Incomer- 125 A TPN microprocessor MCCB, microprocessor-based trip unit with LSIG, electronic trip (overcurrent, short-circuit & earth fault) – 1 No. 2.) Outgoings - 32A / 40A / 63A, TPN MCB, 10 kA – 4 Nos. 3.) Neutral link and Earth link – 1 Set. Note: The job includes all accessories, terminations, earthing, testing & commissioning as per specifications and directions of the Engineer-in-Charge.
2.11 M.V.CABLES 500 m Excess(+) Full Conversion INR
2.12 Copper Cables: Supply, installation, testing & commissioning of 1.1 KV grade Cu. armoured cable for Outdoor units on Wall/Cable tray XLPE insulated, inner sheath PVC , extruded outer sheath PVC with FRLS and rodent termite repellent properties, GI strip / wire armoured, copper conductor power ca 500 m Excess(+) Full Conversion INR
2.13 ble confirming to IS : 1554 part I/IS 7098 part-1 with upto date amendments, fixed on cable tray (measured as separate item) all fixing accessories, etc. complete including painting of M.S spacers/angles and saddles all as per enclosed detailed specifications, drawings & as per instructions of the E-I-C. The space between the two supports shall be 600 mm. approximately. The rodent and termite repellent property of MV cable shall be proved by either testing at factory or by submitting appropriate test certificates as per instructions of EIC. 500 m Excess(+) Full Conversion INR
2.14 4C x 16 sq. mm. Copper Conductor cable. 250 m Excess(+) Full Conversion INR
2.2 800A MCCB Switch- Fabrication, Supply, installation, testing & commissioning of 800 A Electrical Switchboard, powder-coated, wall-mounted, front-operated, front-access, cubicle type, totally enclosed, IP-42 protected, with hinged and lockable doors, fabricated from 2 mm thick CRCA MS sheet, including all interconnections, tinned copper crimping lugs, earthing/bonding, cable end boxes on both sides, suitable for 415 V, 3-phase, 4-wire, 50 Hz system and designed for 50 kA symmetrical fault level at 415 V, complete as per specifications, drawings and instructions of EIC, comprising the following: 1.) 800A, 4-Pole MCCB, 50kA breaking capacity, microprocessor-based LSIG trip unit, with extended rotary handle and ON/OFF/TRIP indication – 1 No. 2.) Multifunction Meter, 3-phase 4-wire, CT secondary 5A, Class-1, flush mounting 96×96 mm, indicating Voltage, Current, Frequency, PF, Power & Energy, similar to Model EM6436H of Schneider / equivalent – 1
2.21 4C x 10 sq. mm. Copper Conductor cable. 900 m Excess(+) Full Conversion INR
2.22 4C x 6 sq. mm. Copper Conductor cable. 300 m Excess(+) Full Conversion INR
3 3C x 2.5 sq. mm. Copper Conductor cable.
3.1 3.5C x 300 sq. mm. Al.
3.11 3.5C x 70 sq. mm. Al. 50 nos. Excess(+) Full Conversion INR
3.12 END JOINTS 40 nos. Excess(+) Full Conversion INR
3.13 END JOINTS FOR COPPER CABLE: End jointing of Cu. Stranded cable by crimping with supply of all jointing materials like solderless tinned copper cable socket, cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge. 30 nos. Excess(+) Full Conversion INR
3.2 4C x 16 sq. mm. Copper
3.21 4C x 10 sq. mm. Copper Conductor cable. 30 Supply, installation, testing and commissioning of 63A, 415 V, 3-phase (TPN) MCB, 10 kA breaking capacity, housed in a suitable factory-made powder-coated MS enclosure (IP-42), including all accessories such as ferrules, interconnections, earthing, mounting hardware, including fixing on wall and making good the site complete as required and as per the direction of Engineer-in-Charge. Excess(+) Full Conversion INR
3.22 4C x 6 sq. mm. Copper Conductor cable. 36 Supply, installation, testing and commissioning of 63A, 415 V, 3-phase (TPN) MCB, 10 kA breaking capacity, housed in a suitable factory-made powder-coated MS enclosure (IP-42), including all accessories such as ferrules, interconnections, earthing, mounting hardware, including fixing on wall and making good the site complete as required and as per the direction of Engineer-in-Charge. Excess(+) Full Conversion INR
4 4C x 10 sq. mm. Copper 1000 m Excess(+) Full Conversion INR
5 4C x 6 sq. mm. Copper
5.1 END JOINTS FOR ALUMINUM CABLE : End jointing of Al. Stranded cable by crimping with supply of all jointing materials like solderless tinned copper cable socket, cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge. 500 m Excess(+) Full Conversion INR
5.2 CABLE TRAY: Supply & fixing of ladder type GI cable trays of size 300 mm (W) x 50 mm (D) x 2 mm (T) with vertical sides on both ends and suitable MS supports including concrete bolts, hold fast etc. The scope includes supply of readymade bends, reducers,Tee, covers etc. as required as per instructions of EIC. 500 m Excess(+) Full Conversion INR
6 EARTHING SYSTEM : Supply, installation & testing of earthing system & associated accessories, etc. of Tinned Copper strip/wire fixed on cable tray with saddles, interconnections of earth strip/wire with brass nuts, bolts & washers and solder jointing, painting with two coats of green enamel paint for earth wire/strip on surface, etc. complete all as per layout drawing, specifications & as per the instructions of E.I.C. 4 Supply, installation, testing and commissioning of 32A, 415 V, 3-phase (TPN) MCB, 10 kA breaking capacity, housed in a suitable factory-made powder-coated MS enclosure (IP-42), including all accessories such as ferrules, interconnections, earthing, mounting hardware, including fixing on wall and making good the site complete as required and as per the direction of Engineer-in-Charge. Excess(+) Full Conversion INR
7 25 x 6 mm Copper Strip. 8 Supply, installation, testing and commissioning of 32A, 415 V, 3-phase (TPN) MCB, 10 kA breaking capacity, housed in a suitable factory-made powder-coated MS enclosure (IP-42), including all accessories such as ferrules, interconnections, earthing, mounting hardware, including fixing on wall and making good the site complete as required and as per the direction of Engineer-in-Charge. Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Chief Engineer (ESG)
Name of Work: Supply, Installation, Testing and Commissioning of HVAC System for School of Computer & Mathematical Science Buildings at NISER, Bhubaneswar, Orissa.
250A MCCB Switch- Fabrication, Supply, installation, testing & commissioning of 250 A Electrical Switchboard, powder-coated, wall-mounted, front-operated, front-access, cubicle type, totally enclosed, IP-42 protected, with hinged and lockable doors, fabricated from 2 mm thick CRCA MS sheet, including all interconnections, tinned copper crimping lugs, earthing/bonding, cable end boxes on both sides, suitable for 415 V, 3-phase, 4-wire, 50 Hz system and designed for 50 kA symmetrical fault level at 415 V, complete as per specifications, drawings and instructions of EIC, comprising the following: 1.) 250A, 4-Pole MCCB, 50 kA breaking capacity, microprocessor-based trip unit (as applicable), with extended rotary handle and ON/OFF/TRIP indication – 1 No. 2.) Multifunction Meter, 3-phase 4-wire, CT secondary 5A, Class-1, flush mounting 96×96 mm, indicating Voltage, Current, Frequency, PF, Power & Energy, similar to Model EM6436H of Schneider / equivalent – 1 No. 3.) 250/5A, Class-1, 10VA / 15VA burden, Cast Resin Current Transformers – 3 Nos. 4.) RYB Indication Lamps (LED type) – 1 Set Note: Scope also includes fixing of switchboard on wall with necessary accessories as required.
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT TOTAL AMOUNT In Words
1 Each 1 Job Excess(+) Full Conversion INR 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
2 MAIN M.V PANEL: Supply, installation,testing & commissioning of Electrical panel, powder coated floor mounting,front operated for acess cubicle type, totally enclosed, with IP-55 protection with hinged and backable doors. It shall be fabricated from 2mm thick CRCA sheets including interconnections, tinned copper crimping lugs, bonding to earth, suitable for use at 415 V, 3 phase 50 HZ system and suitable for a fault level of 35 KA symmetrical at 415 V complete as per specification, instruction, drawings & approval of E-I-C as below : All switchboards shall have provision for entry of cables from the top/bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Notes :-1) All G.A. & fabrication drawings shall be got approved from the E.I.C. Necessary touch up painting may be done at site, incase if required. The scope includes all tests as specified in department's specification, relevant I.S. and as required by E.I.C, shall have to be performed at factory & at installation site and shall be included in the quoted rate. 2) The equipment shall be designed to ensure complete safety during operation inspection, connection of cables etc. 3) Control wires shall be of 1.1 KV 1.5 sq.mm FRLS copper wires and neatly bunched separately and adequately supported so as to prevent sagging and strain on termination. 4) A minimum of 20% spare terminals shall be provided on each terminal block for future requirement. 5) All metallic parts of the equipment not carrying current shall be earthed with copper material 6) All concealed hinged doors and covers shall be provided with suitable flexible earthing connections. 7) The size of the earth bus chosen shall be to withstand full fault current of 35KA 8) Earth bus bar shall be supported at suitable intervals. 9) All the current transformers shall be resin cast type Class-1 only. 10) Name of fabricator, G.A. & detailed fabrication drawing and short circuit forces and temp rise calculation for panel shall be submitted for dept's approval. 11) Bimetallic washers shall be used for all aluminium to copper joints & it shall be of approved make & quality. 12) Indication lamps shall be heavy duty cluster type LED. 13) All Outgoing feeders shall have 'ON' & 'OFF" indication lamps. 14) All neutrals shall be isolatable type. 15) Power cabling between motor and starter shall be measured separately. Control cabling between panel and tank shall be measured separtaely. However, any other control / power wiring / cabling, if required is in the scope of this item. 1 Job Excess(+) Full Conversion INR
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.99 MB
DetailedNITNISERVRV.pdf
Tender Documents • 0.97 MB
TechdatasheetNISERVRV.xls
Tender Documents • 0.08 MB
Drawing103070.pdf
Tender Documents • 0.30 MB
Drawing113071.pdf
Tender Documents • 0.17 MB
Drawing123072.pdf
Tender Documents • 0.33 MB
TechBidSGFNISERVRV.pdf
Tender Documents • 1.76 MB
BOQ_933260.xls
BOQ • 0.39 MB
Drawing053065.pdf
Tender Documents • 0.23 MB
Drawing133073.pdf
Tender Documents • 0.17 MB
Drawing063066.pdf
Tender Documents • 0.23 MB
Drawing012944.pdf
Tender Documents • 0.40 MB
Drawing073067.pdf
Tender Documents • 0.22 MB
Drawing143074.pdf
Tender Documents • 0.29 MB
Drawing022945.pdf
Tender Documents • 0.32 MB
Drawing032946.pdf
Tender Documents • 0.34 MB
Drawing083068.pdf
Tender Documents • 0.21 MB
Drawing042947.pdf
Tender Documents • 0.31 MB
Drawing093069.pdf
Tender Documents • 0.40 MB
Download all tender documents and submit your bid