Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹26.1 L+₹6.4 L (32.6%)Rejected-Finance 712 GORAKHPUR JABALPUR 482001 MP | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹33.2 L+₹13.5 L (68.5%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Oct 2020, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR AND MAINTENANCE OF CEILING FAN, EXHAUST FANS GEYSERS WALL MOUNTED AND WEATHER HEATING APPARATUS AND OTHER CERTAIN WORKS UNDER GE (WEST) JABALPUR
2020_MES_381789_1
8274/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹80,000
16 Nov 2020
29 Sept 2020
29 Oct 2020
29 Sept 2020
27 Oct 2020
13 Oct 2020
30 Sept 2020 - 10 Oct 2020
Amount
M&L for Rewinding of ceiling fans including opening of fan, Removing the burnt copper winding of ceiling fan after testing and cutting the rotor coil complete and making clean the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling, lubricating with fresh grease including assembling with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for the following .
(a). 1200mm sweep .
(b) 1400mm sweep
M&L for Rewinding of Exhaust fans including opening of fan,Removing the burnt copperwinding of ceiling fan after testing and cutting the rotor coil complete and making clean the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling,lubricating with fresh grease including assembling with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for the following
(a). 450mm sweep .
(b) 380 mm sweep
(c) 300/230 mm sweep
M&L for Rewinding of Wall/Bracket fan including opening of fan, removing the burnt copper winding of ceiling fan after testing and cutting the rotor coil complete any make cleaning the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling, lubricating with fresh grease including assembling with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for 400mm sweep. Note for item No 1 to 8 : Contractor shall to collect fans from AGE E/M Electric store yard & deposit the repaired fans in AGE E/M Store yard
M & L for Opening of ceiling fan of any make and any sweep for over-hauling complete including providing fresh clean lubricating Oil/ grease, reassembling for proper functioning , with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for the following .
(a) 1200mm sweep .
(b) 1400mm sweep
M & L for Opening of Exhaust fan of any make and any sweep for over-hauling complete including providing fresh clean lubricating Oil/ grease, reassembling for proper tunning, with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for the following :
(a) 450mm sweep .
(b) 380 mm sweep
(c) 300/230 mm sweep
Supply only in replacement of ball bearing of 6201/120 for ceiling fan/ exhaust fan of any size and make complete. Make : NBC, SKF, TATA
Ditto all as per above item but 6202/115 complete. Make : NBC, SKF, TATA
Ditto all as per above item but 6203/117 complete. Make : NBC, SKF, TATA
Ditto all as per above item but 6204/118 complete. Make : NBC, SKF, TATA
Supply only in replacement of condenser 2.5 MFD of apporved make forceiling fan complete. Make : ED cos, Scimanse, Unic
Ditto all as per above item but 4.0 MFD for exhaust fan complete. Make : ED cos, Scimanse, Unic
Supply only in replacement of self lubricating bush of gun metal of same make for ceiling fan/exhaust fan complete.
Supply only in replacement of shaft of approved quality for ceiling fan/Exhaust fan any make and type & size complete.
S&F in replacement of split pin suitable for ceiling fan/ exhaust fan any make and type & size complete.
S&F in replacement of PVC flexible 3 core cable with copper con-ductor of size 16/0.20 mm from ceiling rose to fan including connection complete.-
S&F in repair celing fan 1200 mm permanent magnet brushless DC motor 230v 50 hz single phase 28-30 watt rated current 0.16 amp, pf- 0.98, 370/360 rpm air delivery 220m3 rated service value 6. 29m3/min/watt, no of blade three type of blade leaf 1.05 mm thick aluminium sheet remote control radio frequency 5 speed + off timer option speed regulation class of insulation two nos bearings incliuding connecting wire complete with all as required and directed at site.Make: orient /havells/bajaj/khaitan Note : Old U/s ceiling fan of any sweep shall be deposited at AGE E/M E/S Store yard.
M&L for painting of ceiling fan including preparing the surface of body/blades of ceiling fan of any sweep and make and painting with 2 coats of synthetic enamel white paint and writing the MES No. with black paint 2.5 cm height letters comlete.
M&L for painting of exhaust fan including preparing the surface of body/blades/frame of of exhaust fan of any sweep and make and painting with 2 coats of synthetic enamel Grey paint and writing the MES No. with black paint 2.5 cm height letters comlete.
M&L for Hanging only ceiling fan and connecting up with point wiring complete for satisfactory functioning complete with PVC flexible 3 core copper conductor cable. Note: (i) Ceiling fans for hanging in the buildings with regulator shall be issued by Engineer-in-charge on proper issue voucher & receipt voucher after repair.
S&F in repairs rubber seal suitable for ceiling fan of any make and size.
S&F in repairs GI pipe medium grade with all fitting and fixed complete for ceiling fan as down rod of 15 mm bore.
S&F in replacement GI pipe 40mm medium grade with all fitting and fixed complete for hanging of ceiling fan .
M&L in replacement for clamps and back plates fabricated from steel section bolts, washers, drilling holes for bolts in any shape or size for fixing ceiling fan complete weighing not more than 2Kg.
Supply & Fixing in replacement Wall mounting fan 400mm sweep complete. Make :almonard/Bajaj/ Havells. Note : Old U/s existing wall mounting fan of any description shall be deposited at AGE E/M E/S store yard.
M& L for comprehensive maintenance and overhauling of ceiling fans at site of any make and size including following works (a) Checking proper working of ceiling fans. (b) Checking of safety pin/sockets/clamps including replacement of unseviceable part (c) Replacement of unserviceable condenser/bearings. (d) Cleaning of ceilingfan/overhauling with fresh grease. Note : 1.Contractor has to depute Two electricians daily who will report to JE /Fan incharge. 2 Unserviceable parts to be measured & paid seperately under relevant item of Sch A.. 3.All T & P and ladder provide to electrician at site by The contractor.
Taking down carefully storage type water heater any make and capacity from clamps/bolts including disconnection water and electric connection and refixing the same and connecting up after cleaning of geyser and repairs complete.
M&L for repair of inner flange of 25/50 Ltrs geysers and replacement of worn-out stud brazing with gas welding not exceeding 5mm thick complete.
Supply and fix in replacement geyser flange assembly (any make/type) copper alloy chromium plates suitable for 25 Ltrs capacity including rubber gasket, clamps and nuts/bolts etc complete. Make : Racold ditz, Bajaj ISI mark.
Ditto all as per above item but 50 Ltrs complete. Make : Racold,Ditz, Bajaj ISI mark.
Supply and fix and connecting heating element ( triangular or circular base type) 1.5 KW 230 volts suitable for 25 ltrs capacity geysers in replacement of old unserviceable heating element complete.Make : Hot Pace, Power Pace, Das Pass ISI mark.
Supply and fix and connecting heating element ( triangular or circular base type) 2 KW, 230 volts suitable for 50 ltrs capacity geysers in replacement of old unserviceable heating element complete ,Make : Hot Pace, Power Pace, Das Pass ISI mark.
Supply only in replacement thermostae t of existing type/make complete
Supply only in replacement indicating lamp, 230 volts rectangular type complete.
Fixing and connecting only geyser 25/50 ltrs capacity including necessary GI fittings and electric connection complete Note: Geysers will issued under schedule 'B' free for fixing only
S&F in replacement GI tube medium grade 15mm bore fixed to wall/geyser into short places including cutting, screwing, threading and all GI fittings (including union, socket if required) complete.
S&F in replacement geyser bottom cover complete including machine screws etc. as per original size and shape of any make of geyser 25 ltrs capacity complete.
Ditto all as per above item but for 50 ltrs capacity complete.
S&F flexible pipe connection heavy duty suitable for hot water supply with two Nos brass chromium plated union 450 mm long in replacement of PVC pipe connection complete
S&F in replacement non return valve of 15mm size of brass for geyser (weight of valve shall not be less than 400 grams) complete.
M&L for painting of geyser with two coats of synthetic enamel white paint and writing the MES No. (letter not less than 1.5 cm height)for 25 ltrs capacity geyser of any make and type complete.
Ditto all as per above item but of 50 ltrs capacity complete.
S&F in replacement stop valve cast copper alloy 15mm bore at inlet or outlet connection of geysers.
S&F in replacement PVC insulated over all PVC sheathed three core copper cable of size 1.5 sqmm including disconnection of old cable complete.
S&F in replacement PVC insulated over all PVC sheathed three core copper cable of size 2.5 sqmm including disconnection of old cable complete.
S&F Pressure release valve suitable for 25/50 ltrs any make any type of geyser complete in replacement of dead weight.
Removing old glass wool for the geysers and providing new glass wool of equal thickness and specification :-
(a) Capacity 25 Ltrs
(b) Capacity 50 Ltrs
S&F in repair three pin top15 Amp 240 volts complete all as specified directed
S&F in repair Top for ;earth plug socket 20 Amps AC 240 Volts complete all as specified and directed by Engineer in charge/
S&F in repalcement single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SP 20/32 Amps complete all as directed by Engineer-in-Charge.
Supply & fixing in replacement connection and testing exhaust fan single phase 240 Volts AC 50 Hz with louvers of size 300 mm sweep including cutting holes in wall and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed. Note : Old U/s existing exhaust fan of any description shall be deposited at AGE E/M E/S store yard.
M&L for making opening by cutting/chasing existing PCC/Masonary wall for fixing of exhaust fan of 300mm/450 mm sweep capacity including grouting of foundation bolts complete plastering and making good distrubed surface good complete all as specified and directed.
S & F in replacement Water heater storage type Geyser , electric supplied and installed complete capacity 25 litres. Copper inner tank Star rated complete with fixing and required nut bolts and making connection with plug top 15 amps all as required and direted at site. Note : Old U/s existing Geyser of any description shall be deposited at AGE E/M E/S store yard.
S&F in replacement safety valve suitable for geyser 25/50 litre as per sample.
Supply & fixing in replacement connection and testing fresh air fan 230 mm sweep plastic body single phase 240 Volts AC 50 Hz with in built louvers of size 230 mm sweep including cutting holes in wall and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed. Note : Old U/s existing fan of any description shall be deposited at AGE E/M E/S store yard.
Opening and rewinding the fresh air fan 230 mm sweep with suitable size of wire of existing size and varnishing the winding all as required and directed at site
Cutting the wall and making the good to disturbed surface with existing colour and fixing the nut bots all as required and directed at site
Supply & fixing in replacement connection and testing Plastic body fresh air fan single phase 240 Volts AC 50 Hz with louvers of size 300 mm sweep including cutting holes in wall and 3 core copper wire of size 0.50 sqmm for connection complete all as specified and directed. Note : Old U/s existing fan of any description shall be deposited at AGE E/M E/S store yard.
Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge.
Taking down carefully and re-fixing ceiling fan / Exhaust fan of any sweep with 1.5 Sqmm new copper wire upto ceiling rose complete all as specified and directed.
S&F in repair Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6.0 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
S&F in repair Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 2.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 4 Sqmm & one run of 2.5 Sqmm cable shall be measured as one unit run.
S&F in repairs Sub main wiring with two single core PVC Insulated cable two run of size 2.5 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 1.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 2.5 Sqmm & one run of 1.5 Sqmm cable shall be measured as one unit run.
Supply & fixing in repair 25 mm dia non mettalic Rigid PVC conduit, ISI Marked conforming to IS : 9537 medium grade Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified & directed.
S&F in repair Sub main wiring with four single core PVC Insulated cable four run of size 6.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 32 mm dia with all conduit accessories and two run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Four run of 6.0 Sqmm & two run of 4.0 Sqmm cable shall be measured as one unit run.
S&F in repair Sub main wiring with four run single core PVC Insulated cable of size 10.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 40 mm dia with all conduit accessories and two run of 6.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete all as specified and directed. Note : - Four run of 10.0 Sqmm & two run of 6.0 Sqmm cable shall be measured as one unit run.
Material & Labour for concealed Point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into and including concealed PVC conduit medium grade not less than 20mm (ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup washers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge.
(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket point 5 Amp controlled by one switch on same board.
(d) One socket point 5 Amp controlled by one switch on Independent board.
(e) One socket point 5 Amp controlled by one switch on Independent board below the switch board.
(f) One bell point controlled by one bell push button independent board.
Ditto all as per above item here in before but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
M&L for drawing the wire in existing conduit steel/PVC complete with point wiring withtriple layer FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following:
i) One light point point controlled by one way, single pole switch
ii) One light one fan point controlled by one way, single pole switch
(iii) One 3 pin socket outlet, 6 Amp on “independent board” but below/side the switch board of the light point in same vertical plane.
(iv) One 3 pin socket out let, 6 amps on the "same board" with other switches
(v) One 3 pin socket outlet, 6 Amp on “independent board”
(vi) One bell / buzzer point controlled by one bell push
(vii) One light point controlled by two way switch
Ditto all as per above items but drawing in existing conduit for point wiring using 2.5 Sqmm (Nominal area)triple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
M&L for drawing the wire in with casing caping complete with point wiring withtriple layer FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -Make of wire -Finolex/plaza/gloster
i) One light point point controlled by one way, single pole switch
(ii) One light one fan point controlled by one way, single pole switch
(iii) One 3 pin socket outlet, 6 Amp on “independent board” but below/side the switch board of the light point in same vertical plane.
(iv) One 3 pin socket out let, 6 amps on the "same board" with other switches
(v) One 3 pin socket outlet, 6 Amp on “independent board”
(vi) One bell / buzzer point controlled by one bell push
(vii) do but one light point controlled by two way switch
Ditto all as per above items drawing in with casing caping point wiring using 2.5 Sqmm (Nominal area)triple layer FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
Supply & Fixing Modular Switches 5 /6 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Switches 15 /16 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Sockets 6 amps 3/5 pin with fixing arrangements all as required and directed at site
Supply & Fixing Modular Sockets 15/16 amps 5/6 pin with fixing arrangements all as required and directed at site
Supply & Fixing Ceiling Fan regulator modular electronic ROTARY / Step type 80/120 Watt capacity of ploycarbonate body ISI marked complete all as specified & directed.
Supply & Fixing Modular bell push switches 5 /6 AMPS with fixing arrangements all as required and directed at site
Supply & Fixing Modular Switches 5 /6 AMPS single pole two way with fixing arrangements all as required and directed at site
Supply & Fixing switch piano flush button type single pole one way 5 Amps of polycarbonate complete all as specified & directed.
Supply & fixing of call bell ding dong sound type suitable for AC 240 volt single pole complete all as specified & directed.
Supply & Fixing switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.
Supply & Fixing socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified & directed.
Supply & Fixing Switch socket combination 2 in 1, 3 pin / 5 Amp and 15 Amps flush type universal of polycabonate body complete all as specified & directed.
Supply & Fixing lamp holder / batten or angle holder Insulated body with back plate suitable for batten fittings complete all as specified & directed.
Supply & Fixing 9 Watt capacity LED lamp fixed in lamp holder complete all as specified & directed.
Supply & Fixing Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified & directed.
Supply & Fixing Ceiling Fan regulator electronic ROTARY / Step type 100 / 120 Watt capacity of ploycarbonate body ISI marked complete all as specified & directed.
Supply & Fixing in replacement 18/20 watt LED tube light fitting four feet long box type high efficiency aluminum linear batten type along with fixed on surface / wall or Pendent mounting Luminaires connector block etc, with all accessories internally pre-wired and connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified & directed. Make : Surya Cat No -SLEBT 20 MS or Wipro Cat Part No. LL20-221-xxx-NE or equivalent make & model in Philips / Crompton
S&F in replacement LED Mirror light fitting 9 watt along with fixture Surface mounted suitable for indoor aplication , connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge. Make: Surya Cat No SLE BT 9 W ARROW OR Luker code no LMR 10 or Wipro or equivalent in philips/syska
Supply and fixing in replacement of decorative wall light fitting WITH LAMPS 9 WATT made up of Polycarbonate , , Cylindrical shape , with LED lamp complete with fixing arrangements on wall all as specified and directed. make CITY 1 OF HAVELLS /luker light code no LWL-110-2 or equivalent DECON/ or equivalent Bajaj/Philips/CG as approved by GE
Supply & Fixing in replacement Bulk head endura LED light fitting complete with10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suitable size & length complete all as specified & directed. Make : Havells Cat Part No. RUGBY NEONFT10WLED760SSYMBOP/ BIBWP10W LED OF BAJAJ Equivalent make & model in Philips / Crompton
Supply & Fixing in replacement of Indoor commercial recessed mounted luminaires energy efficient LED luminaire suitable for 600mm x 600mm for grid ceiling light not less than 36 watt with diffusers channel incluidng all accessories, internally pre-wired & making connection to ceiling rose with copper conductor of suitable size & length complete all as specified & directed. Make : Surya cat no sle fp 36 r22 or Wipro Cat Part No. CRCO10R036HP57G1 or Equivalent make & model in Philips or crompton or Havells
Supply & fixing in repair 25 watt LED security light fitting out door type with stove enamelled finish sheet aluminium housing with CRCA sheet steel reflector, ribbed acrylic bowl cover and accessories with 40 mm dia GI pipe light grade bracket fixed with 30x5 mm FI clamp with nut bolts & washers complete in all respect as specified & directed. Make : Bajaj Cat part NO BRLEP25W/LED or equivalent in philips & havells
Supply & fixing in replacement electronic energy meter tamper proof design digital technology of three phase 3 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current for CT operated meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete all as specified & directed at site make HPL socomec model PPEM 01 or equivalent in Havells or as approved by GE.
Supply & fixing in replacement electronic energy meter tamper proof design digital technology of SINGLE phase 1 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current for CT operated meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete all as specified & directed at site make HPL socomec model PPEM 02 or equivalent in Havells or as approved by GE.
Taking out old Unserviceable meter of any capacity after disconnecting the electric connection and refixing the electric meter new or old as directed of any capacity and making necessary electric connection and sealing the same with sealign wire and lead seal complete all as directed at site.
Supply & Fixing in replacement sheet metal enclosure MCB DB double door [Acrylic], Triple pole and neutral, 415 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO 507670 / SIEMENS CAT NO 8GB32203RC04 / GE
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO 507610 /SIEMENS /ABB / Schinider
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO 507611 / sIEMENS CAT NO 8 GB 32102RC8/GE
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 12 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed. Make : Legrand CAT NO507612 / SIEMENS CAT NO 8GB32203RC12/GE
Supply & Fixing in repair MCB Triple Pole and Neutral 63 Amps,10KA breaking capacity complete all as specified & directed. Make : Legrand DX3 TPN C 63A AC 408683 / Siemens cat no- 5SL44637 RC / GE
Supply & Fixing in repair MCB double pole 230Volt, 32 Amps,10KA breaking capacity complete all as specified & directed. Make : Legrand DX3 DP CAT No 408636/ Siemens cat no- 5SL 42327RC / GE
Supply & Fixing in repair MCB Single Pole 240Volt, 6 to 32Amps,10KA breaking capacity complete all as specified & directed. Make : Legrand cat no DX3 SP 408587,408590,408592,408593,408594,408595 / Siemens cat no- 5SL41067RC, 5SL41107RC, 5SL41167RC, 5SL41207RC, 5SL41257RC, 5SL41327RC / GE
S&F in repair recessed mounted downlighter LED light 3 Watt all as specified and directed.Make: Surya cat part no: SLE DLR 3 W STELLAR PRIME or in equivalent philips ,bajaj,wipro
S&F in repair essential LED spots MR16/GU10 50 W all as specified and directed.Make :Philips Cat part no: ESS LED MR16 4.5-50W 36D or in equivalent Surya ,Bajaj,wipro
S&F in repair tube 14 watt complete all as required
S&F in repair bipin holder sutable for tube light fitting rotary type all as required and directed at site
S&F in repair T-5 tube light 28 watt complete with repair the tube light fitting etc all as required and directed at site Make : Bajaj/Havells/Wipro
S&F in repair electronic ballast 28 watt suitable for T-5 lamps all as requird and directed at site
Supply & fixing in replacement MCCB with thermal magnetic protection of 63 amps 415 volts 3 pole capacity complete all as specified & directed. Make : Legrand cat no DPX3 TP 420003 / Siemens/ GE/ABB
Supply and fixing in repair 36 watt 4 pin lamps complete
S&F in repair 36 watt ballast suitable for CFL 36 watt lamps all as required and directed at site
S&F in repair Led Lamps 20 watt with fixing all as required and directed at site
Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete.
RAVI TEJ BUILDERS
RAVINDRA ELECTRICAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .