Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹8.7 LAccepted-AOC | 1st | Accepted-AOC The lowest bidder M/s Parikshit Sharma has been accepted please. | |
| 2 | 2nd₹11.5 L+₹2.6 L (28.6%)Rejected-Finance | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹11.6 L+₹2.6 L (28.9%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹13.7 L+₹4.7 L (52.6%)Rejected-Finance 148 SANGHI STREET MHOW MP 453441 | MHOW | INDORE | MP | 453441 | 4th | Rejected-Finance L4 | |
| 5 | 5th₹13.8 L+₹4.9 L (54.6%)Rejected-Finance | 5th | Rejected-Finance L5 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
17 Aug 2020, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
REPAIR TO 6/5 GR, ACE AND MAP QTRS AND SEWAGE LINE PATH CULVERT BOUNDARY WALL IN STN UNIT AREA UNDER GE (AWC) MHOW.
2020_MES_361976_1
8422 GE(AWC) /MHOW / OF 2020-21
Open Tender
Civil Works
Works
270 days
GE AWC MHOW
All as per Tender Documents and NIT.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹30,000
Yes
26 Sept 2020
18 Jul 2020
18 Aug 2020
18 Jul 2020
17 Aug 2020
4 Aug 2020
Amount
Cleaning blockage of floor/nahani/bottle trap of wash hand basin/sink/bathrooms/kitchen by using hand pump with rubber bucket or by cleaning rod till clear flow of water is observed all complete all as specified and as directed.
Cleaning blockage of sewer lines in any position by rodding from both sides between two adjacent manholes or from inspection chamber to manhole or from gully trap to inspection chamber or through inspection eye of any depth till clear flow of sewer/water is observed complete all as specified and as directed for the 100mm dia (internal) of sewer pipe line. Note:- Unit rate quoted shall deemed to be included of cleaning of scurbs, grass small roots etc, around the manholes, inspection chamber at adjacent to the pipe lines cleaning etc and along sewage lines wherever required or as directed and no extra payment shall be made on this account).
Description same as per item No 02.00 above but for 150mm dia (internal) of sewer pipe line.
Description same as per item No 02.00 above but for 200mm dia (internal) of sewer pipe line.
Cutting in to existing manhole’s for connecting new drains making good to pipe and rendering cutting out existing benching and forming brand channel ( ½ round or ¾ section) in cement concrete type B1 smooth finished and reforming benching as required internal dia pipe 100 mm dia pipe.
Description same as per item No 05.00 above but for 150mm dia pipe.
M&L for cleaning of septic tank of any capacity, inclduing excavation in trenches not exc. 1.5m in dept in mud in fould poistion by de-sludging, disilting and getting out all silt, sludge, organic and inorganic materials by manuyally / mechanically and removing the sludge to a distance exc 250 mtr but not exc. 500 mtr away from site and burrying in to pits and covered with earth including spreading bleaching powder @ 1 kg per sqm complete all as directed at site. After complete cleaning of septic tank the manhole cover shal be re-fixed in same position with CM 1:4 and bleaching powder spread on top surface of septic tank @ 1 Kg per septic tank complete all as specified and directed at site.
Description same as per item No 07.00 above but depth of septic tank exc 1.5 mtr and n. exc 3 mtr.
Excavation in trench in any type of soil not exceeding 1.5M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete.
Demolition and breaking up drain pipe of dia 100mm (internal dia) (salt glazed stoneware, AC or reinforced conrete) set in cement mortar complete all as specified and directed.
Demolition and breaking up drain pipe of dia 150 mm (internal dia) (salt glazed stoneware, AC or reinforced conrete) set in cement mortar complete all as specified and directed.
Demolition and breaking up drain pipe of dia 200 mm (internal dia) (salt glazed stoneware, AC or reinforced conrete) set in cement mortar complete all as specified and directed.
M & L cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate for the 100 mm internal dia of pipe complete all as specified and directed.
M & L cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate for the 150 mm internal dia of pipe complete all as specified and directed.
M & L cement concrete bed to drain pipe including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate for the 200 mm internal dia of pipe complete all as specified and directed.
Supplying, laying, jointing and testing salt glazed stone ware drain pipe of size 100 mm internal dia of pipe grade 'A' confirming to IS-651-1980 laid in trenches and jointed cement kmortar 1:1 complete all as specified and directed.
Supplying, laying, jointing and testing salt glazed stone ware drain pipe of size 150 mm internal dia of pipe grade 'A' confirming to IS-651-1980 laid in trenches and jointed cement kmortar 1:1 complete all as specified and directed.
Supplying, laying, jointing and testing salt glazed stone ware drain pipe of size 200 mm internal dia of pipe grade 'A' confirming to IS-651-1980 laid in trenches and jointed cement kmortar 1:1 complete all as specified and directed.
Returning, filling in Soft/Loose soil including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete.
Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete.
Demolition of brickwork or stone masonary built in cement mortar including all quoins, arches,pillars etc. complete.
M & L Brick work with sewer bricks straight or curved on plan exc 6 m mean radius for man-holes/septictank /soakwell etc, in sewer work in CM 1:4 complete all as specifed and directed.
Description same as per Item No. 22 above but except brick complete. Note :- Old serviceable brick obtained from demolition shall be re-used. The rate quoted against this item is inclusive of necessary cleaning and stacking of bricks before incorporation in the work.
Taking down existing cement plaster on brick or stone wall including racking out joints, hacking for key, scrubbing down with water etc complete.
M & L 15 mm thick rendering in cement mortar 1:4 mixed with water proofing compound @ 3% per one Kg of cement by weight or as per manufacturer instruction on brick work or concrete surfaces, surface finished even and smooth without using extra cement complete. Note :- WPC shall be measured and paid separately as supply only.
Supply only Integral water proofing compound complete.
M&L preparing surfaces and white washing three coat on walls.
Demolition of reinforced cement concrete of any description for manhole cover, slab of septic tank & soak well etc complete.
M & L providing pre-cast cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in cover slab of manholes, septic tank, soak well etc set in cement mortar 1:4 with plain fair faces including chamfered weathering, throating etc including necessary use and waste of form work complete.
M&L for RCC 1:1 1/2:3 Type A-1 using 20mm graded stone aggregate as in slabs supported on wall, beam and columns in floors, roof slabs and in shelves complete
Use and waste form work to soffits of suspended slabs fair finished such as roof slabs, floor slabs, Landings and similar work not exceeding 200 mm thick, fair finished surface of concrete complete.
Use and waste form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings openings in concrete wall, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horisontal or sloping and smiliar work exc 10cm but n. exc 20 cm wide, rough finished surfaces of concrete complete
S & F mild steel TMT bars 6 to 8 mm dia as in reinforcement, cut to length, benty shape required including cranking, bending, spirally for hooping for columns, hooking ends and hinding with mild stee wire (annealed) not less than 0.9 mm dia or securing with clips complete.
M& L for loose filing of broken bricks aggregates, of gauge 80 to 150mm as in soakage pits, soakage walls etc, complete.
S&F in repairs 75 mm internal dia of pipe PVC (SWR) single socketed in any length with solvent cement fixed to walls incluidng clamping complete. Make :- Finolex,Supreme, Kissan Mouldings Pvt Ltd
S&F in repairs 110mm internal dia of pipe PVC (SWR) single socketed in any length with solvent cement fixed to walls incluidng clamping complete. Make :- Finolex,Supreme, Kissan Mouldings Pvt Ltd
S & F in repairs Plastic water closet seat cover black or any colour and size closed patter with flat bottom, and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F 75 mm bore PVC cowl including taking out existing unserviceable cowl complete
S & F 110 mm bore PVC cowl including taking out existing unserviceable cowl complete
Demolition of cement concrete (un-reinforced in ground floors and paving not exc 15 cm thickness below or above ground level complete.
M & L PCC 1:3:6 type C-I using 20 mm graded aggregate as in mass concrete, foundation and any other location etc. complete.
M & L PCC 1:3:6 type C-I using 20 mm graded aggregate as in surface channel, drain etc. including necessary use and waste of form work complete
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds mitered or stopped ends etc. complete.
S & F in repairs, vitreous china wash down water closet pedestal pattern white,(excluding flushing cistern and flush pipe) with ‘P’ or ‘S’ trap including connection to trap and to flushing pipe and fixing of sheet cover ‘white’ complete including making good to floor complete.
M & L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in benching to drain, coping, bed block etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete.
S & F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm X 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete.
S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including bracket with 32 mm dia PVC pipe 600mm long complete.
S & F in repair PVC (SWR) nahani trap with grating having diameter of outlet 75 mm including joining to waste pipe with solvent cement complete.
S & F in repair 110 mm dia bore PVC (SWR) pipes single socketed in any length with solvent cement joints, fixed in floor/ trenches complete all as specified and directed. Make :- Finolex,Supreme, Kissan Mouldings Pvt Ltd
S & F in repair 75mm dia bore PVC (SWR) pipes single socketed in any length with solvent cement joints, fixed in floor/ trenches complete all as specified and directed. Make :- Finolex,Supreme, Kissan Mouldings Pvt Ltd
S & F in repair 110 mm dia bore PVC (SWR) bends any radius with solvent cement joints, fixed to complete all as specified and directed.
S & F in repair 75mm dia bore PVC (SWR) bends any radius with solvent cement joints, fixed to complete all as specified and directed.
S & F in repair 110 mm dia bore PVC (SWR) junction single, single (T) equal or unequal with solvent cement joints, fixed to complete all as specified and directed.
S & F in repair 75mm dia bore PVC (SWR) junction single, single (T) equal or unequal with solvent cement joints, fixed to complete all as specified and directed.
S & F in repair vitreous china urinal , full stall type white (excluding flushing cistern , flush pipe ) and waste pipe complete all as specified and as directed.
M&L for Vitreous china urinal partition white of size 310 X 700 mm fixed in repair.
S & F in repairs vertical discharge pipe for Urinal.
S & F in repair, for vitreous china wash basin flat back of size 550x400mm pedestal pattern incl brackets, cutting for and pinning in ends or brackets, 32 mm dia waste coupling and down pipe and also refixing of piller tap , PVC connection complete all as specified and directed.
Demolition of cement concrete in any description and any position etc removal from site up to 500 m complete all as specified and directed.
M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in sub base of floor complete all as specified and directed.
M&L for 80mm thick machine pressed precast interlocking paver block(glossy finished) with grey cement with pigment conferming to IS 15658-2006 of M-40 grade ,laid dry & jionts filled with fine sand and shape,colour and pattern as approved by GE,laid required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
M& L for providing precast cement concrete kerb blocks(machine pressed) ,solid,cement concrete type B-1,1:2:4 (20mm graded aggregate) finished at top bullnosed shape and finished surface even and smooth and jointed in cement mortar 1:4 stuck finished including necessary earth work complete all as specified and directed.
kriti construction
yash enterprises
M/S Ashish Construction
Sameer Auto Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .