Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC | ₹2.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.5 Cr+₹4.6 L (1.91%)Rejected-Finance 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | ₹2.5 Cr+₹4.6 L (1.91%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹2.8 Cr+₹42.3 L (17.5%)Rejected-Finance | ₹2.8 Cr+₹42.3 L (17.5%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹2.9 Cr+₹52.5 L (21.7%)Rejected-Finance 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹2.9 Cr+₹52.5 L (21.7%) | L4 | Rejected-Finance Other than L1 |
Tender Value
₹3.1 Cr
EMD Value
₹3.9 L
Closing Date
25 Nov 2021, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg Camp Pune 411001
ADDN/ALT AND SPECIAL REPAIRS INCLUDING REPLACEMENT OF ROOF AND LEAKAGE/ SEEPAGE TREATMENT TO SELECTED OLD MD ACCN UNDER GE (SOUTH) PUNE
2021_MES_465556_1
84518E8
Open Tender
Civil Works
Item Rate
730 days
GE South Pune
CLASS A AND CATEGORY a(i)
7 documents required · 7 mandatory
₹2,000
GE South Pune
₹3.9 L
Yes
4 Jan 2022
6 Aug 2021
27 Nov 2021
6 Aug 2021
25 Nov 2021
11 Nov 2021
6 Aug 2021 - 30 Aug 2021
Amount
Demolition of stone slab and tiles of any description or thickness laid bedded and pointed in cement mortar, as in floors, hard standing , Aprons etc complete all as specified & directed.
Taking down chowkat or frames (wooden /steel) with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each complete all as specified and directed including making good disturbed wall surfaces/jambs with cement plaster in 1:4 of thickness as required at site or disturbed masonry, if any, in PCC 1:3:6 type C-1 using 20 mm graded stone aggregates finished even & smooth using extra cement all as specified and directed.
Taking down chowkats or frames (wooden/steel) with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed including making good disturbed wall surfaces/jambs with cement plaster in 1:4 of thickness as required at site or disturbed masonry, if any, in PCC 1:3:6 type C-1 using 20 mm graded stone aggregates finished even & smooth using extra cement all as specified and directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15cm thick (below or above ground level) unreinforced all as specified and as directed.
Demolition of brick work or PCC block masonry or stone/boulder masonry, built in cement mortar, including all quoins, arches, pillars etc, complete all as specified & directed.
Taking down cement plaster on brick/ block walling including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling of structural steel work including doors, gates but excluding framed Truss etc complete all as specified and as directed.
Dismantling and disconnecting existing water tanks 250 lit/ 500 lit/1000 litre capacity and removing to store or removing from site etc. complete all as directed.
Dismantling of Cast Iron / AC/ PVC/Salt glazed ware drain pipes of various dia jointed in cement mortar or chemical adhesive, 75 to 100mm dia all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for but including sunken portion, unreinforced etc all as specified and as directed.
Demolition of reinforced cement concrete in roof, floor (other than ground floors), beams, staircase, landings, Chajjas and other similar suspended works; reinforcement cut as required to facilitate demolition, all as specified and directed..
Dismantling Wrought iron or mild steel work as in old cooler stand, angle support for chajja/facias, post etc of any description, not otherwise provided for, all as specified and directed.
M&L Non skid ceramic coloured tiles of size 400mm x 400mm and 7 to 8mm thick in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M&L Non skid ceramic coloured tiles as in skirting using Non skid ceramic tiles of size 400mm x 400mm and 7 to 8mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match complete over & including 10mm thick backing coat of cement mortar 1:4 including triangular filleting in cement mortar 1:4 on top of skirting all as specified.
M&L Glazed ceramic coloured tiles of size 300mm x 600mm and 7 to 8 mm thick of approved colour as in dado etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete over & including 10mm thick backing coat in cement mrotar1:4 including triangular filleting in cement mortar 1:4 on top of dado all as specified and directed.
M&L Non skid ceramic coloured tiles of size 300mm x 300mm and 7 to 8mm thick in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tile, over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M&L PCC(1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in levelling course for laying floor tiles on undulated/uneven/depressed floor area complete all as specified & directed.
M&L Prepolished machine cut kota stone 20 to 25mm thick single piece as in treads/riser of steps/staircase etc and of size as required at site, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of kota stone slab laid over and including 10mm thick screed bed/backing coat in CM 1:4. (Note: Kota stone shall be provided with bull nosing for tread slab & 2 Nos of 5mm thick anti skid grooves at one edge all as directed)
M&L Hand cut Kota stone of size 600mm x 450mm flooring (or near size available) and 20 to 25 mm thick; laid, jointed with grey cement slurry and pointed with coloured cement to match the shade of Kota stone as in floor etc. including rubbing and mirror polishing complete; laid over and including screed bed 20mm thick in CM 1:6 complete all as specified and directed.
M&L 18 to 20mm thick Granite work (of any type/colour) work, table rubbed and polished as in steps, cladding on pillars, window cills/jamb, cooking platforms, counters of any radius and like, set in cement mortar (1:4) including pointing in white cement mixed with marble dust in 1:2 proportion using admixture of pigment to match with shade of granite; laid over and including 15mm thick screed bed or backing coat in Cement Mortar (1:6) complete all as specified and directed.
Labour only for chamfering splays or arries in face work not exceeding 15mm wide, for thickness of granite stone slab 18 to 20mm complete; all as specified and directed.
M&L 20-25mm thick machine cut cudappah stone slabs, machine polished on one side, fixed independently as in shelves or for cooking platform and the like, set in and including cement mortar 1:4 as required etc, complete all as specified and as directed.
S&F in repair 18 mm thick prelaminated particle board interior grade, Conforming to IS-12823, Gde-I, prelaminated both side with decorative choice lamination as in Kitchen Cabinet etc, fixed with screw including 3mm thick, 1st Class HW (TW) beading all around on edging and fixed to timber frame work all as specified and directed.
S&F in repairs 40 mm dia cupboard Knobs (as approved by GE) fixed with nuts, screws and washer of brass polished, all as specified and directed.
S&F in repairs continuous (Piano) hinges, mild steel bright finished or electro galvanised width of flap 30mm, all as specified and directed.
S&F Pressed steel frames for doors with one or more rebates including necessary hold fasts, hinges, lock strike plate etc complete as specified; size of frame 105 x 60mm; filled with PCC 1:3:6 type C-0 using 12.5mm graded stone aggregates all as specified and directed.
S&F pressed steel frames for doors with one or more rebates including necessary hold fasts, hinges, lock strike plate etc complete as specified size of frame 125 x 60mm filled with PCC 1:3:6 type C-0 using 12.5mm graded stone aggregates all as specified.
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels commercial type on both faces incl 6mm thick Ist class HW (Teakwood) beading all around on edges, all as specified and directed.
S&F IInd class hard wood Kiln seasoned and chemically pressure treated, glazed and skeleton shutters 35mm thick factory made, open rebated and prepared to receive glass, gauge,etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass,etc; the size of the rail and stile as per IS 1003 (Part-I), supplied and fitted to chowkhats all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube, supplied and fixing in opening all as per specification & drawing, all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed colour PVC ‘C’ channel having a wood grain printed PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain printed colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. complete all as specified and as directed.
M&L Preparation of new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, all as specified and directed.
Supply and fixing three track sliding window with two shutters with 4mm thick tinted glass and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18 mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc; fabricated using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engineer-in-Charge. (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352. (Note:- Cost of Tinted glass & wire cloth shall be included in the quoted rate of the item).
Supply and fixing fixed glass ventilators using 5mm thick figured/plain glass and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc all as directed. (a) SP - 20048 (b) Glazing clips - 19352; complete all as specified and directed by Engineer-in-Charge. (Note:- Cost of figured/plain glass shall be included in the quoted rate of the item).
S & F butt hinges 100mm size MS cold rolled medium weight all as specified.
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long.
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 300 mm.
S&F aluminium handles, anodised, cast type, of size 150 mm
S & F 300mm, Mild Steel ordinary rat tail rod pattern spring including roller and roller plate complete.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18 mm & fixed with stainless steel wire staples all as specified.
Removing of old water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust, foreign materials including flushing at junction of wall and removing the rubbish off the premises to a distance exc 500m all as directed by Engr-in-Charge
M&L Water proofing treatment to RCC roof slab and shall be carried out as specified below and as directed (a) M&L 10mm thick screed bed in CM 1:3 on concrete surfaces of roof slab and parapets mixed with and including WPC @ 3% by weight of cement finished even and smooth without using extra cement. (b) The roof surface shall be thoroughly wire brushed, cleaned to eliminate all sharp projection , surface washed, dried up and cleaned of all foreign matter and dust to receive primer. (c) M&L Applying bituminous primer on cleaned surface @ 0.40 Litre/Sqm. (d) M&L Providing APP polymer modified approved membrane 3mm thick, non woven, polyster,weighing not less than 3.6 Kg/Sqm and laying on roof surface and parapets with laps, overlaps and sealing joints as specified and applied completely by torch application method, the overlap of membrane while torching shall be kept 100mm on length wise and 100 mm width wise; all as specified & directed. (e) M&L Carrying out test by flooding water for 24 hrs for leakages & seepages and rectifying the same to the entire satisfaction of GE. (f) M&L Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 litre/Sqm on the top of membrane surfaces complete all as specified & directed. (g) The treatment shall be carried out as per manufacturers instructions and through authorised applicator of manufacturer. (Note:- The contractor shall furnish the following :- (i) Quality confirmation from the manufacturer of the product alongwith quantity supplied. (ii) Manufacturer test certificate. (iii) The result if tested any of the independent laboratory, the testing charges shall however be borne by the contractor).
Disconnecting existing tanks ,setting aside (or lowering if required) for repair ,cleaning etc and hoisting if required reconnecting and refixing in position of capacity 500 Litre and more but not exceeding and including 1000 Litre complete; all as specified and as directed.
M&L 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base / flooring complete; all as specified and directed.
M&L 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) as in floor, finishing the surface even and smooth without using extra cement, all as specified and directed.
S&F Glass dividing strips 3 mm thick and 38 mm wide inserted in position as dividing strip in flooring; all as specified and directed.
M&L 100 mm thick PCC 1:2:4 Type B-2, using 40 mm crushed graded stone aggregate as in PCC path and paving; finished even and fair without using extra cement including making impressions of expanded metal,whilist concrete is green all as specified and directed.
M&L PCC 1:3:6 type C-2, (using 40mm graded stone aggregate), 75mm thick, laid in alternate bays including finishing the surfaces even and smooth using extra cement as in plinth protection, all as specified and directed.
M&L Chequered cement concrete tiles 25cm x 25cm x 22 mm thick, with grey cement and pigment, set jointed and pointed in neat cement slurry; as in floor, laid over and including 15mm thick screed bed in CM (1:6) all as specified and directed.
Material and labour Brickwork using old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed.
M&L Rendering 10mm thick in CM 1:6, on brick/ PCC block walling, finished even & smooth, all as specified and directed.
M&L Rendering 15mm thick in cement mortar 1:4 on brick/concrete surfaces using water proofing compound as per manufacturers instructions surface finished with sponge finish, all as specified and directed. (Note : WPC shall be measured and paid separately).
Supply only water proofing compound all as specified and directed.
M&L Rendering 5 mm thick in CM 1:3 on concrete surface finished even and smooth with a thin layer of sagol; as in ceiling, soffits etc., all as specified and directed.
M&L Preparing newly plastered surfaces of walls and applying two coats of acrylic emulsion distemper over a coat of alkali resistant primer over and including two coats of wall care putty (Total thickness of wall care putty not less than 1.5mm in two coats). all as specified and directed.
M&L Preparing newly plastered surfaces and applying two coats of white wash in ceiling, all as specified and directed.
M&L Preparation of old painted wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint, all as specified and directed.
M&L Complete removal of existing treatment and applying two coats of acrylic emulsion distemper on walls over a coat of alkali resistant primer over and including two coats of wall care putty (Total thickness of wall care putty not less than 1.5mm in two coats), all as specified and directed .
M&L Preparing old decorated surfaces of ceiling and applying one coat of white wash on ceiling, all as specified and directed.
S&F Towel rails 600mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight 190gms), all as specified.
S&F Rolled mild steel structural steel work Fe-410W of grade E-250, quality A; in roof trusses (framed), purlins, rafter, post etc. including shaped washers, necessary cutting to required length, notching, drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plate, gusset plate etc including erecting in true position complete all as specified and as directed.
S&F Rolled mild steel structural steel work Fe-290 of grade E-165 for framed work as in door or gates of angle or other section with gusset plates rails, braces, etc complete drilled for fixing of steel sheeting or other covering of doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, fastening, etc complete all as specified and directed.
M&L Mild steel framed work conforming to Fe-410 or Fe-310 using MS angle or other sections as in grills, gratings with ends of bar shouldered and / or riveted or forged into spikes; framed guard bars; railings, frame work of water tank and like completed all as specified and directed.
M&L Preparing new or previously untreated surfaces of steel exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L Cast iron floor/Nahani trap with grating 75mm dia including jointing to waste pipe including fixed in and including cement concrete type (1:2:4) type B1 including removing old traps complete, all as specified and directed.
M&L SGSW gully trap of size 150x150mm, square or round mouthed, type 'P', 'Q' or 'S' as required at site, including setting and jointing to drains with CM 1:1, all as specified and directed.
Supply and fixing rotational moulded polyethylene water storage tank 500 Litres capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with 20 mm ball valve high pressure PTMT with rod & high density plastic ball complete all as specified and directed.
Taking up or down carefully steel tubing and connection s including cleaning for refixing or removal to store of size 15mm bore.
Taking up or down carefully steel tubing and connection s including cleaning for refixing or removal to store of size 20mm bore.
M & L for 15 mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and directed.
M & L for 20mm bore GI tubing medium grade with all fitting and fixed complete on walls and ceilings or laid in floors etc complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, ceilings, floors etc) 15mm bore.
Refixing old steel tubing and connections in new or old position (wall, ceilings, floors etc) 20mm bore.
Material and labour for Cutting chases, pinning in. brick work making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed
S&F PVC (SWR) pipes of size 110mm bore, single socketed in any length with rubber ring joints laid in trenches or fixed to wall complete all as specified & directed
S&F PVC (SWR) pipes of size 75mm bore, single socketed in any length with rubber ring joints laid in trenches or fixed to wall complete all as specified & directed
S&F PVC (SWR) bends any radius 110 mm bore
S&F PVC (SWR) bends any radius 75 mm bore
S&F in repairs vitreous china, squatting pan, 'Orissa' pattern, size 580 x 440mm white, with integral foot rest, including concrete bedding and PVC flushing cistern 10 Litre capacity including all internal fitting, inlet, outlet pipe connections etc. complete all as specified and directed.
S & F vitreous china wash basin white flat back of size 550mm x 400mm including 15mm dia CP pillar tap, CP waste coupling 32mm, chain and plug and PVC waste pipe including CI brackets, etc. complete in repairs all as specified and directed.
S & F in repair sink made out of stainless steel 1mm thick for kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe for over all size 495mm x 420mm, bowl size 410mm x 330mm x 160mm (or nearest size) complete all as specified and directed.
Supply and fixing looking mirror of size 600 x 450mm approved quality and make , mounted on 6 mm thick plywood commercial as backing and aluminium powder coated frame all around on edges complete.
S&F 15mm bore bib taps, brass chromium plated, cast copper alloy fancy type handle, screwed down, screwed for iron pipes all as specified fixed in repairs.
Supply and fixing aluminium powder coated brackets suitable for 20mm dia curtain rod (minimum projection from wall 75mm) fixed in wall including drilling, rawl plug, screws etc complete all as specified and directed. Note: Curtain rod shall be measured and paid for separately.
Supply and fixing aluminium powder coated fancy type curtain rod 20mm bore all as specified and directed by Engr-in-Charge.
S & F in repair stop valve 15mm bore brass chromium plated, screwed down high pressure with long shank handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
S&F in repair stop valve brass chromium plated, fancy type with long shank and cup (concealed type) fixed to pipe of 15mm bore.
Supply and fix in repairs, stainless steel plate rack of size 36inch x 31inch x 10inch, made out of 0.63mm thick stainless steel sheet (Grade AISI 304 18/8), S S screws and round pipe, fixed to wall with screws complete all as specified and as directed.
Material and labour Water proofing treatment to sunken slab, walls, etc, shall be carried out as specified below and as directed by Engineer-in-Charge.
(a) Clean the sunken portion of toilet/Baths/WCs/Kitchen thoroughly remove laitance, dirt, dust etc.
(b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (“ Dr fixit” Pidicrete URP” or eqvt).
(c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bath seal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bath seal Grout” or eqvt. Nahani traps etc to be fitted securely and the gaps around it to be grounted in the same manner.
(d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bath seal Plus” or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.
(e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or eqvt can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.
(f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2.
(g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC SIKA, MC BUCHEMIE, ROFF, etc.
M & L PCC 1:5:10 type E-2 (using 20mm graded stone aggregate) lean concrete for filling sunken floor, mass concrete, sub base and similar places complete as specified & directed.
M&L PCC (1:2:4) type B-1 using 20mm graded stone aggregates as in coping on top of wall, bed blocks, lintel band upto 1.5 metre span, haunching, padding and the like including weathering, slightly rounded or chamfered angles and throating as directed including use of necessary form work.
Supply and fixing butt Hinges, medium weight, brass, 50 mm B 12 size complete all as specified.
Supply and fixing aluminium handles fabricated type, anodized of 150 mm size complete all as specified and directed.
S&F floor door stopper, aluminium alloy body and tongue anodised with hard drawn steel spring of 140mm size overall.
M&L Preparation of old painted surface of steel over 10 cm width or girth and applying one coat of synthetic enamel paint at working height upto and including 15 Metre, unless otherwise described, complete all as specified and directed.
S&F PVC (SWR) junction, (Single Tee) equal or unequal 110mm bore
S & F in repairs long body 'U' shaped sink taps cast copper alloy with chromium plated fancy type screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed bore of pipe 15mm in kitchen sink or counter sink or basin.
Supply and fixing Swivel shower rose size 125 mm of PTMT , any colour , for fixing with 15 mm dia pipe ,( minimum weight 40 gm. ) with and including Shower arm 15 mm size, 195 mm long with bend of 45 degree with flange of PTMT any colour (Min wt 40gms) , fixed in repairs , complete all as specified and directed .
S & F PVC connection 60 cm long 15 mm bore with 2 Nos PTMT check nuts fixed in repairs.
Removal of trees / roots from wall ( height of building not exc 15m ) including dismantling wall, filling wall with concrete, plastering and finishing wall surface same as existing finishes complete all as specified and directed.
Material and labour PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
Material and labour two coats home shield smart care PU magnum of Asian paints over chajja and roof for water proofing all as specified and directed.
Supply and fixing gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for size 20mm dia.
Excavation in trenches n.exc 1.5mtr wide and n.exc. 1.5m in depth for foundation and getting out in soft/loose soil.
Excavation in trenches n.exc 1.5mtr wide and n.exc. 1.5m in depth for foundation and getting out in hard/dense soil.
Removing excavated material not exceeding 50mtr and depositing where directed at a level n.exc 1.5 metre above the starting point all as specified and directed by Engr-in-Charge.
Returning filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm
M & L RCC pipes class NP-2, with socketed ends,150mm bore laid and jointed as specified complete
M&L PCC 1:4:8 type D2 using 40mm graded aggregate as in bed to drain pipes including forming cradles for 150mm RCC hume pipe as specified and directed.
M&L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, for the following internal dia of pipe 150mm.
S & F MS plates conforming to Fe-410W (Gde E-250) square cut or notched forming holes without any attachment.
Supply and fixing in replacement (existing cupboard shutter) with mild steel almirah shutters with frame, exceeding 1.5 Sqm, made of 1mm thick mild steel sheet in two leaves as built in furniture in cupboards including locking arrangement with mortise lock of mild steel, vertical type, 65mm size, 2 lever, ISI marked with duplicate keys and handle and suitable hinges etc (all as per Godrej pattern) including two coats of spray painting over a coat of red oxide primer complete fixed on brick or concrete wall with minimum six numbers of 10mm dia and 100mm long mild steel bolt with washer and nut in cement mortar (1:4) or PCC 1:2:4, type B-0 and including all arrangement / hardwares required for fixing complete all as specified and directed.
Material and labour for cutting hole in brick wall built in cement mortar for inserting cooler stand angles and like, making good dismantled portion in CM 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but n.exc one brick.
M&L for MS framed work conforming to grade E-165 (Fe-290) or Fe-310-O of MS angle or other sections, such as grills, gratings with ends of bar shouldered and / or riveted or forged into spikes; framed guard bars; railings, supports for chajja,cooler stand, RCC drop roof facia, frame of angle iron door and like completed all as directed by Engineer-in-charge.
Use and waste of form work to Chajjas, troughs and similar items including edges for rough finished flat surfaces.
S&F MS TMT bars upto 10mm dia, cut to length, bent to shape required, including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
M&L Nominal mix RCC using 1:2:4 type B-1 using 20mm graded stone aggregate, as in fins, facias, chajjas.
M & L Precast cement concrete 1:2:4 type B-1 using 20 mm graded stone agg for cover slab of manholes set in cement mortar 1:4 including use & waste of formwork.
Material and labour Scrapping and removing old paint, lease material and algae fungus then cleaning of surface with water using pressure washer machine ,then crack filling with acrylic based textured crack filler an application of one coat of primer primer cum sealer having alkali resistance property diluted with water and mixed with bio block in ratio 5:4:1 followed by application of two coats of modified acrylic apex exterior emulsion paint of approved shade having silicon additives in paint which gives 5 year of performance warranty (Make : Burger/Nerolac/Asian paint) complete all as specified & directed.
M&L Preparation of new plastered surfaces of walls & one coat of primer primer cum sealer having alkali resistance property diluted with water and mixed with bio block in ratio 5:4:1 followed by application applying two coats of modified acrylic apex exterior emulsion paint which gives 5 year of performance warranty. (Make : Burger/Nerolac/Asian paint) complete all as specified & directed. all as specified.
Taking down carefully point wiring any type (light, fan, socket or power) complete, removing the material from site and making good disturbed surfaces of walls, floors etc. (Note :- Removal of fittings such as switches, ceiling roses, pendants, sockets etc. to be measured separately).
Taking down carefully by unscrewing from the boards, out lets boxes/ceiling/walls the fittings and fixtures such as switches,sockets,ceiling rose, lamp shades lamp holders, tube light, bulk head fittings, street light fittings,MCBs/DBs etc of any type/size and capacity
Taking down unserviceable submain wiring of any description any type and any size complete all as specified and directed.
M & L Point wiring complete with and including single core PVC insulated unsheathed flexible bright annealed multi stranded copper conductor FRLS cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through and including heavy grade PVC rigid conduits 20 mm or higher dia as reqd at site, totally concealed in walls/floors/ ceiling including all conduit accessories /fittings /junction boxes/ inspection covers etc; of heavy grade, ISI marked and sunk terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls with 3 mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets fan regulators etc; including 1.5 Sqmm (22/0.30 mm) 1100 V grade PVC insulated, unsheathed flexible multi stranded copper conductor FRLS cable as continuous earth wire connected to metallic bodies of luminaries/fans etc; at one end and to common earth dolly at other end, all as specified & directed for One light/fan/ point controlled by one switch and regulator.(Note: Rate quoted is deemed to be inclusive for cutting chases in wall for concealed wiring & making good disturbed surfaces to match existing)
All as per item No 124 above but for One 3 pin 5 Amps Socket outlet point controlled by one switch on independent board.
All as per item No 124 above but for One 3 pin 5 amps socket outlet point on same board with other switches
All as per item No 124 above but for One bell/buzzer point controlled by one bell push.
All as per item No 124 above but for one two way light point controlled by two nos. Two way switches complete.
All as per item No 124 above but with stranded copper conductor 2.5 Sqmm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 6/16 Amp socket outlet on independent board including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed.
M&L Concealed sub main wiring complete with two single core 4 Sqmm 1100 volt grade PVC insulated, stranded copper conductor (FRLS) cable with continuous copper earth conductor 1 x 4 Sqmm passing through & including PVC conduit/accessories complete all as specified and directed by Engr-in-Charge. (Note:- (a) 2 runs of 4 Sqmm cable and 1 run of earth wire incl PVC conduit shall be measured as one length.) (b) Rate quoted is deemed to be inclusive for cutting chases in wall for concealed wiring & making good disturbed surfaces to match existing)
S&F switch piano flush type, 5 amps, 230 volts, single pole one way .
S&F ceiling rose surface bakelite, 2 to 3 terminals with base plate.
S&F switch socket outlet combination multipurpose 2 in 1, 5/15 amps, 230 volts flush type.
S&F switch piano flush type, 15 amps, 230 volts, single pole one way .
S&F socket outlet, 5 amps, 3 pin 230 volts, flush type.
S&F lamp holder PVC insulated body with back plate suitable for batten/angle
S&F bell push, flush type, 5amp
S&F bell electrical ding dong including teak wood board.
S&F in replacement ceiling fan regulator, electronic step type, deluxe, suitable for fan 48"/56" sweep complete all as directed
S&F MCB,DB double door, SPN 8 way, 240 volts with 200 amps rated bus bar.
S&F double door, MCB DB 4 way SPN with 200 Amp rated bus bar 240V including whether proof and vermin proof sheet metal enclosure.
S & F MCB SP 6 to 32 Amps 240 Volts, '' C'' series 10KA
S & F MCB SPN 40 to 63 Amps 240 Volts, '' C'' series 10KA
S & F exhaust fan PVC body exhaust fan 300mm sweep, 1400 RPM single phase, light weight, white/ivory plastic rust proof body & blades, self opening louvers for protection from birds and rain water, fixing by means of rugged bolts, nuts and washers etc on round hole cut in wall, including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC,SP 230 v electric supply. Make as listed in Appendix 'C', complete all as specified and directed.
M & L Cutting and making hole into cement concrete/stone masonry wall for fixing exhaust fan of size 300mm sweep and providing fasteners grouting in wall / including fixing arrangement and making good the disturbed surface with PCC 1:2:4 type B1 & cement plaster 1:4 to match existing surface all as directed.
M&L Earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter in deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level including connecting GI earth wire 4mm dia by GI nut, bolt, washers all as shown in electrical plate No. 3 of SSR Part I of 2009 including funnel for watering, PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in pit / chamber, RCC 1:2:4 type B0 using 12.5mm graded stone aggregates and 6mm dia mild steel bats at 100mm c/c as in chamber cover, charcoal, salt etc complete including excavation and earth work in any strata, test point and testing on completion including filling up the earth pit with black cotton soil for best result and removal of excavated material from site all as specified and directed by Engineer-in-charge. (Note : GI earth wire and GI protection pipe upto 7.5 meter length shall be included in this item.)
S & F LED tube light fitting complete with all fitting & fixing accessories, 1x20 Watt prewired with high efficiency electronic driver, glare free, smooth light distribution conforming to cat No. LUMILINEPLUS20WLED8655PCSS of Havells or of equivalent make specified here-in-after.
S & F integral LED security light luminaries 30W comprising of epoxy powder coated aluminium pressure die cast housing with glass cover and lens in frame suitable for mounting on & including bracket made of 40mm GI pipe light grade complete with accessories, conforming to cat No. LPCRSRT30WXC of Jaguar or of equivalent make specified here-in-after including taking down old fitting.
S & F LED tube light fitting complete with all fitting & fixing accessories, 1x10 Watt prewired with high efficiency electronic driver, glare free, smooth light distribution of makes specified here-in-after.
S & F IP-54, IK 09, protection metal double door vertical TPN DB rated bus bar,415 volts,50Hz complete with interconnection links, blank plates, cable ties, identification labels TPN 8 way, 24 modules complete with MCCB 4 pole 100 amps as incomer and SP/TP MCB as outgoing and concealed in wall including all cutting holes through walls, making good to disturbed surfaces to match the existing.
Supply, laying and testing cable XLPE insulate, screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 Volts grade stranded aluminium conductor of size 35 Sqmm, 3.5 core laid in trenches, wall or floor complete all as specified and as directed.
Supply and spreading fine dry river sand for cushioning to UG cable including spreading, leveling and hand punning etc complete all as specified and directed. (Note :The punned thickness shall only be measured for payment.)
Supply & laying un reinforced precast concrete cable cover class LV type I flat size 250 mm X 150 mmX 40mm complete
S & F in replacement GI pipe, light grade 50mbore,conforming to IS - 1239, for cable protection on poles/walls/Road crossing/floor crossing all as directed.
Anand Trading Co
L.K.R.TIWARI CONSTRUCTION
Mehta Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .