| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.9 L+₹48,605 (1.41%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹35.9 L+₹1.5 L (4.43%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹40.6 L+₹6.2 L (18.0%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹40.6 L+₹6.2 L (18.0%)Rejected-Finance 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L5 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | krishna Associate L1 | Vijay Electricals L4 | DEMROT ELECTRICAL WORKS L6 | M/s Ranaji Construction Co L2 | shyam construction L5 | PARM BUILDERS L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old Unserviceable air termination rod of any size and capacity complete all as specified. | 700 | Each | 10 ₹7,000 | 4 ₹2,800 Lowest | 20 ₹14,000 | 10 ₹7,000 | 5 ₹3,500 | 10 ₹7,000 |
| 2.00 | Refixing of serviceable Air termination rod as obatined from Item No 01 above including new threading and grinding of tip of air termination as per site requirnment complete all as specified. | 500 | Each Job | 50 ₹25,000 | 5 ₹2,500 Lowest | 100 ₹50,000 | 15 ₹7,500 | 20 ₹10,000 | 20 ₹10,000 |
| 3.00 | S&F single pointed air termination aluminium rod 12 mm dia and 300 mm long complete all as specified. | 200 | Each | 100 ₹20,000 Lowest | 150 ₹30,000 | 200 ₹40,000 | 120 ₹24,000 | 350 ₹70,000 | 135 ₹27,000 |
| 4.00 | Taking down old Unserviceable aluminium strip from roof and wall of ESHs any size and position including making good to disrurbed surface of wall and roof complete all as specified. | 5,000 | RM | 15 ₹75,000 | 4 ₹20,000 | 5 ₹25,000 | 2 ₹10,000 | 1 ₹5,000 Lowest | 10 ₹50,000 |
| 5.00 | Refixing of serviceable aluminum strip 25x3 mm complete as obtained from above item 04 with new saddle / insulators, including straightning and fixing screws/accessories for roof and down conductor complete all as specified. | 2,000 | RM | 15 ₹30,000 | 23 ₹46,000 | 20 ₹40,000 | 5 ₹10,000 Lowest | 15 ₹30,000 | 15 ₹30,000 |
| 6.00 | S&F aluminium srip of size 25x3 mm complete with insulator/saddle and fixing with screw/accessories for roof and down conductor complete all as specified. | 3,000 | RM | 80 ₹2,40,000 | 65 ₹1,95,000 | 50 ₹1,50,000 | 30 ₹90,000 Lowest | 100 ₹3,00,000 | 92 ₹2,76,000 |
| 7.00 | Taking down old Unserviceable GI rusted pipe from roof or wall of size 40/50 mm and position including making good to disrurbed surface of wall and roof complete all as specified. | 600 | RM | 10 ₹6,000 | 25 ₹15,000 | 10 ₹6,000 | 10 ₹6,000 | 5 ₹3,000 Lowest | 15 ₹9,000 |
| 8.00 | S&F GI pipe light grade 40 mm dia for protection of GI strip complete all as specified. | 200 | RM | 400 ₹80,000 | 200 ₹40,000 | 300 ₹60,000 | 300 ₹60,000 | 220 ₹44,000 | 135 ₹27,000 Lowest |
| 9.00 | S&F GI pipe medium grade 40 mm dia for supporting of ACSR conductor grid complete all as specified. | 400 | RM | 400 ₹1,60,000 | 250 ₹1,00,000 | 350 ₹1,40,000 | 440 ₹1,76,000 | 290 ₹1,16,000 | 230 ₹92,000 Lowest |
| 10.00 | Supplying and stringing Aluminium conductor, steel reinforced (ACSR) any type of ACSR conductor for airtermination points supported by GI tubing on the roof of the ESHs to inner connect the all termination points including taking down of existing conductor complete all as specified.
(Notes : (i) The ACSR conductors shall be conforming to IS-398 and as specified in SSR Part-I.(ii) The unit rate quoted shall also be deemed to include for supply & fixing of aluminium binding wire, aluminium tapes etc which shall not be included in the weight of conductors.(iii) Weight of conductors shall be determined by measuring true horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc.
(iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.) | 3 | Qtl | 15,000 ₹45,000 | 9,500 ₹28,500 Lowest | 25,000 ₹75,000 | 12,000 ₹36,000 | 18,000 ₹54,000 | 19,000 ₹57,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
16 Jul 2026, 6:00 pmClosed
GE Bharatpur
GE Bharatpur
REPAIR/REPLACEMENT AND RENEWAL OF LIGHTENING PROTECTION SYSTEM OF ESHs AND OTHER SHEDS INSIDE DEPOT AREA AND BLDG AT KANJOLI LINE, PARADE GROUND AND SEWAR FORT UNDER GE BHARATPUR
2026_MES_772694_1
8647/E8
Open Tender
Civil Works
Item Rate
330 days
GE Bharatpur
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE Bharatpur
₹98,000
Yes
25 Jul 2026
17 Jun 2026
18 Jul 2026
17 Jun 2026
16 Jul 2026
2 Jul 2026
17 Jun 2026 - 27 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old Unserviceable air termination rod of any size and capacity complete all as specified. | 700 | Each | - | - |
| 2 | Refixing of serviceable Air termination rod as obatined from Item No 01 above including new threading and grinding of tip of air termination as per site requirnment complete all as specified. | 500 | Each Job | - | - |
| 3 | S&F single pointed air termination aluminium rod 12 mm dia and 300 mm long complete all as specified. | 200 | Each | - | - |
| 4 | Taking down old Unserviceable aluminium strip from roof and wall of ESHs any size and position including making good to disrurbed surface of wall and roof complete all as specified. | 5,000 | RM | - | - |
| 5 | Refixing of serviceable aluminum strip 25x3 mm complete as obtained from above item 04 with new saddle / insulators, including straightning and fixing screws/accessories for roof and down conductor complete all as specified. | 2,000 | RM | - | - |
| 6 | S&F aluminium srip of size 25x3 mm complete with insulator/saddle and fixing with screw/accessories for roof and down conductor complete all as specified. | 3,000 | RM | - | - |
| 7 | Taking down old Unserviceable GI rusted pipe from roof or wall of size 40/50 mm and position including making good to disrurbed surface of wall and roof complete all as specified. | 600 | RM | - | - |
| 8 | S&F GI pipe light grade 40 mm dia for protection of GI strip complete all as specified. | 200 | RM | - | - |
| 9 | S&F GI pipe medium grade 40 mm dia for supporting of ACSR conductor grid complete all as specified. | 400 | RM | - | - |
| 10 | Supplying and stringing Aluminium conductor, steel reinforced (ACSR) any type of ACSR conductor for airtermination points supported by GI tubing on the roof of the ESHs to inner connect the all termination points including taking down of existing conductor complete all as specified.
(Notes : (i) The ACSR conductors shall be conforming to IS-398 and as specified in SSR Part-I.(ii) The unit rate quoted shall also be deemed to include for supply & fixing of aluminium binding wire, aluminium tapes etc which shall not be included in the weight of conductors.(iii) Weight of conductors shall be determined by measuring true horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc.
(iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.) | 3 | Qtl | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_865240.xls
BOQ • 0.64 MB
tender8647.pdf
Tender Documents • 1.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .