Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.1 LAdmitted-Finance | +8.50% | ₹7.1 L | L1 | Admitted-Finance |
| 2 | L2₹7.1 L+₹4,873.28 (0.69%)Admitted-Finance | +9.25% | ₹7.1 L+₹4,873.28 (0.69%) | L2 | Admitted-Finance |
| 3 | L3₹7.3 L+₹22,741.95 (3.23%)Admitted-Finance | +12.00% | ₹7.3 L+₹22,741.95 (3.23%) | L3 | Admitted-Finance |
Tender Value
₹6.5 L
EMD Value
₹12,995
Closing Date
16 Feb 2026, 3:30 pmClosed
Executive Engineer
IWD IIT Kanpur
Consolidation of Room No 303A 303B and 304A and 304B to convert into a single Facility at New Core Lab SH Electrical works
2026_IITK_896274_1
66/EE/Elect/2025-26
Open Tender
Electrical Works
Percentage
60 days
IIT Kanpur
As per tender
3 documents required · 3 mandatory
₹0
₹12,995
25 Mar 2026
30 Jan 2026
17 Feb 2026
30 Jan 2026
16 Feb 2026
30 Jan 2026
30 Jan 2026 - 3 Feb 2026
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 1.5 sq. mm
3 x 4 sq. mm
6 x 16 sq.mm.
S & F following size of steel flexible pipe along with the accessories on surface etc as required
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supply and fixing of following LED light fixture with efficiency >100 lumen/ watt, P.F. >0.95, THD<10%, Electronic driver, LED lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete.
36 watt recess mounting LED light fixture 600 x 600 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
3 Module
6 Module
Supplying and fixing following size/ modules, plastic box for modular switches in recess etc as required.
3 Module
6 Module
Laying of 1/2/3 run of UTP cable enhanced cat 5/cat 6 cable in existing steel conduit pipe/GI pipe/ raceway / RCC pipe as reqd. the cost shall also include numbering of networking wire from room to rack as reqd. (wire will be supplied by dept)
Fixing of RJ-45 modular box with cover plate or I/o box for internet on surface/ recessed cutting the wall making good the same as required. ( box and cover plate will be supplied by dept.)
Supplying, fixing, painting of 15mm dia GI heavy class pipe down rod for ceiling fan etc as required complete.
Extra for cutting and drilling hole in down rod of 15mm dia GI pipe for ceiling fan etc. as required complete.
Dismantling concealed & damaged DB/TPN Switches/starter/ loose wire boxes along with all accessories and depositing the same in the sectional store repairing the damages as reqd complete.
Dismantling, disconnecting old damaged unserviceable fl fitting/ exhaust fan/ ceiling fan/ bulkhead fitting with bracket etc. as reqd. and depositing in sectional store.
Dismantling the old conduit pipe/wood batten of all sizes from surface/recessed & making good the damages I/c filling the holes of the surface etc as reqd. and depositing it in sectional store.
Fixing 20/25/32 mm conduit pipe/ DLP on surface with clamp/in recessed only conduit pipe supplied by department.(Free of cost)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Overhauling of ceiling fan of any size including dismantling and refixing of fan, bearings, checking, cleaning the all parts and supply & replacement of rubber real, rubber rings, nut bolts, hanger clamps, bearing plates, cotter/ split pin, varnishing if reqd etc, reassembling testing and commissioning of fan as required complete.
Supplying and fixing following capacity capacitor suitable for ceiling fan / exhaust fan / air-curtain etc..
S&F, Copper tube / reducer/ lug terminals suitable for following size of conductor.
Supply and fixing of 105 x 50 mm DLP trunking white-system but without cover and partition etc. as required complete.
Supply and fixing of following accessories suitable for 105 mm x 50 mm size plastic trunking white system.
85 mm flexible cover
End cap
Internal angles- adjustable from 80°-100°
external angles- adjustable from 60°-120°
flat junction
flat angles
separation partitions
Joints for 85mm width cover
Joints for 85mm width cover
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
Tendernotice_2.pdf
PDF • 0.19 MB
BOQ_942057.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .