| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-Finance | L1 | Accepted-Finance RATES ARE FOUND LOWEST | |
| 2 | L2₹1.8 L+₹3,250 (1.85%)Accepted-Finance | L2 | Accepted-Finance RATES ARE FOUND SECOUND LOWEST | |
| 3 | L3₹1.8 L+₹4,350 (2.48%)Accepted-Finance | L3 | Accepted-Finance RATES ARE FOUND LOWEST |
Tender Value
₹1.8 L
EMD Value
₹2,000
Closing Date
29 Dec 2022, 5:00 pmClosed
EE ETD RAIBARELI
OFFICE OF ETD RAIBARELI TRIPULA CAMPUS RAIBARELI
repairing AND rectification work of SCADA system installed at 132 KV SS Sareni Salon under ETD Raebareli
2022_UPTCL_761236_1
09/ETDR/2022023
Open Tender
Electrical Works
Item Rate
60 days
RAIBARELI
Please refer Tender documents.
3 documents required · 3 mandatory
₹236
EE
₹2,000
30 Dec 2022
21 Dec 2022
30 Dec 2022
21 Dec 2022
29 Dec 2022
21 Dec 2022
21 Dec 2022 - 29 Dec 2022
Work of Identification of reason of non/partial performance of SCADA System installed at following substations. Rectification of faults and satisfactory operations /Maintenance works for performance of SCADA System. Scope of work shall include partial/complete items as required for satisfactory operation of SCADA System as below-1- Providing & fixing/Replacement of patch card/cable as required for proper operation of SCADA System after tracing of faulty patch card/cable during preliminary inspection. Proper dressing of patch cable/card and all other associated work 2- Providing & fixing/Replacement of LAN cable as required for proper operation of SCADA System after tracing of faulty LAN cable during preliminary inspection. Proper dressing of LAN cable and all other associated work 3-Providing & fixing/Replacement RS232RJ11/RJ45/ as required Contractor for proper operation of SCADA System 4- Installation, confrigation, testing of SQL server 2005 with new data base, DS agile-V5.1.15.0 base and any other software requirement for proper operation of SCADA System 5-Repair of Motherboard of CPU Unit dedicated for SCADA System. 6-SCADA client-Server topology testing/rectification for smooth operation of equipment. 7- Modbus RTU communication testing/rectification for metering parameters from energy meters. 8-Relay healthiness/communication link testing/rectification rom SCADA HMI 9- Testing and rectification of CRP signals to SCADA HMI like, equipment isolators, earth switch, circuit breakers. BCU operation healthiness checking from LEDs to primary equipment's 10-SCADA operation healthiness checking of primary equipment like isolators, earth switch, circuit breakers BCU operation healthiness checking from lEDs to primary equipment's 11- SCADA HMI soft interlocks and its logic from BCU to each feeder in local/ Remote mode and its healthiness checking for smooth operation for future 12-Checking of buffered/ unbuffered reports of SCADA. 13-Testing/rectification To avoid interruption in SCADA system and its backup storage of hot and standby SCADA HMI 1/2 will be recovered 14-Communication system architecture and fiber optics path between IEDS/BCUS to SCADA HMI-1/2 healthiness checking 15-Checking of events, alarms, SOE and reports of integrating system with time stamping 16- GPS synchronization healthiness checking with BCUs/relays. 17- Addition of new bays/line in SCADA System (in SCADA System) 18-Rectification of any wrongly feeded bays /line (in SCADA System)
132 KV S/S Salon, Raebareli
132 KV S/S Sareni, Raebareli
M/S M K Enterprises
JMD INFRASTRUCTURE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .