Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2384.5 CrAdmitted-Finance 12 LANDT HOUSE SHIVAJI NAGAR NORTH AMBAZARI ROAD NAGPUR MAHARASHTRA 440010 | NAGPUR | NAGPUR | MAHARASHTRA | 440010 | L1 | Admitted-Finance | |
| 2 | L2₹2499.3 Cr+₹114.8 Cr (4.81%)Admitted-Finance 8TH FLOOR BUILDING 9A DLF PHASE III SECTOR 25 GURUGRAM 122002 | GURUGRAM | GURUGRAM | HARYANA | 122002 | L2 | Admitted-Finance | |
| 3 | L3₹2712.1 Cr+₹327.6 Cr (13.7%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | LARSEN AND TOUBRO LIMITED L2 | KEC INTERNATIONAL LTD. L3 | Kalpataru Projects International Limited L1 |
|---|---|---|---|---|---|---|
| 1.00Isolators and accessories as per specification. | ||||||
| 1.10Supply of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required. | ||||||
| 1.11 | 245KV, 2000A, 50kA for 3 sec, Horizontal Double Breaktype Isolator with double earth switch. | 6 | Sets | 21,85,379.53 ₹1,31,12,277.18 | 22,14,457.94 ₹1,32,86,747.64 | 19,79,275 ₹1,18,75,650 Lowest |
| 1.12 | 245KV, 2000A, 50kA for 3 sec, Horizontal Double Breaktype Isolator with one earth switch. | 6 | Sets | 19,21,953.84 ₹1,15,31,723.04 | 19,72,168.32 ₹1,18,33,009.92 | 16,24,887 ₹97,49,322 Lowest |
| 1.13 | 245KV, 2000A, 50kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch (Tandem type) | 4 | Sets | 16,75,086.34 ₹67,00,345.36 | 17,45,108.32 ₹69,80,433.28 | 15,10,788 ₹60,43,152 Lowest |
| 1.14 | 245KV, 2000A, 50kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch | 4 | Sets | 16,60,033.44 ₹66,40,133.76 | 17,31,263.2 ₹69,25,052.8 | 14,53,198 ₹58,12,792 Lowest |
| 1.15 | 72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch. | 2 | Set | 4,77,477.88 ₹9,54,955.76 | 4,67,826.65 ₹9,35,653.3 | 4,44,965 ₹8,89,930 Lowest |
| 1.16 | 72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch. | 2 | Set | 5,81,342.87 ₹11,62,685.74 | 5,63,357.99 ₹11,26,715.98 | 3,90,303 ₹7,80,606 Lowest |
| 1.20Supply of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. | ||||||
| 1.21 | 245KV, Horizontal Double Breaktype Isolator with double earth switch. | 6 | Sets | 2,56,877.96 ₹15,41,267.76 | 1,74,666.97 ₹10,48,001.82 Lowest | 2,45,768 ₹14,74,608 |
Tender Value
Refer Docs
EMD Value
₹35 Cr
Closing Date
5 Nov 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief General Manager (PPnD)
O/o the MD, AEGCL, 1st Floor, Bijulee Bhawan, Guwahati-01
Implementation of transmission infrastructure to evacuate 3200 MW thermal power from upcoming generation station at Chapar
2026_AEGCL_53698_1
AEGCL/MD/Tech-1219/Chapar/2026
Open Tender
Electrical Works
Turn-key
1096 days
Chapar
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
₹35 Cr
Yes
Guwahati
16 Nov 2026
2 Sept 2026
7 Nov 2026
2 Sept 2026
5 Nov 2026
5 Oct 2026
2 Sept 2026 - 15 Sept 2026
16 Sept 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Isolators and accessories as per specification. | |||||
| 1.1 | Supply of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required. | - | - | - | - |
| 1.11 | 245KV, 2000A, 50kA for 3 sec, Horizontal Double Breaktype Isolator with double earth switch. | - | Sets | - | - |
| 1.12 | 245KV, 2000A, 50kA for 3 sec, Horizontal Double Breaktype Isolator with one earth switch. | - | Sets | - | - |
| 1.13 | 245KV, 2000A, 50kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch (Tandem type) | - | Sets | - | - |
| 1.14 | 245KV, 2000A, 50kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch | - | Sets | - | - |
| 1.15 | 72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch. | - | Set | - | - |
| 1.16 | 72.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch. | - | Set | - | - |
| 1.2 | Supply of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. | - | - | - | - |
| 1.21 | 245KV, Horizontal Double Breaktype Isolator with double earth switch. | - | Sets | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.63 MB
Bid_Volume_I.pdf
Tender Documents • 1.96 MB
Bid_Volume_II.pdf
Tender Documents • 11.55 MB
IFB.pdf
Tender Documents • 0.70 MB
Additional Documents_400 kV A Type Foundation.pdf
Additional Documents • 9.26 MB
Additional Documents_400 KV AGIA - CHAPAR LINE TOWER SCHEDULE.pdf
Additional Documents • 0.27 MB
Additional Documents_400 kV B Type Foundation.pdf
Additional Documents • 4.68 MB
Additional Documents_400 kV C Type Foundation.pdf
Additional Documents • 5.39 MB
Additional Documents_400 kV D Type Foundation.pdf
Additional Documents • 1.33 MB
Additional Documents_400 KV DC CHAPAR AGIA LINE (2).kmz
Additional Documents • 0.02 MB
Additional Documents_400kV GIS Building 19 July 2026.pdf
Additional Documents • 0.30 MB
Additional Documents_400kV GIS Extension Module Rangia End.pdf
Additional Documents
Additional Documents_400kV GIS.pdf
Additional Documents • 0.26 MB
Additional Documents_400kV _ Extension Module Approved.pdf
Additional Documents • 6.06 MB
Additional Documents_Agia 400 kv & 220 kv Sw.yard Section.pdf
Additional Documents • 0.98 MB
Additional Documents_Agia 400kV SLD revised 31-08-26-Model.pdf
Additional Documents • 0.47 MB
Additional Documents_AGIA SS MASTER PLAN new block 31-08-26-Model.pdf
Additional Documents • 4.36 MB
Additional Documents_Agia Transformer & 220 kv Sw.yard Layout 31-08-26-Model.pdf
Additional Documents • 1.16 MB
Additional Documents_CABLE TRENCH FOR ROAD CROSSING.pdf
Additional Documents • 0.36 MB
Additional Documents_CABLE TRENCH WITH EDGE PROTECTION.pdf
Additional Documents • 0.54 MB
Additional Documents_CHAPAR- RANGIYA(GANTRY TO GANTRY)27-08-2026 (1).kml
Additional Documents • 0.76 MB
Additional Documents_DRAIN 1.pdf
Additional Documents • 0.43 MB
Additional Documents_DRAIN 2.pdf
Additional Documents • 0.25 MB
Additional Documents_FENCING.pdf
Additional Documents • 0.11 MB
Additional Documents_KIOSK FINAL.pdf
Additional Documents • 0.52 MB
Additional Documents_LAYOUT.pdf
Additional Documents • 2.67 MB
Additional Documents_MAIN ACDB AGIA.pdf
Additional Documents • 0.21 MB
Additional Documents_Pile Foundation 400kV Drawing.pdf
Additional Documents • 0.14 MB
Additional Documents_RANGIA TAMULPUR SS CHAPAR LINE BAY LAYOUT AND SECTION 31-08-26-Model.pdf
Additional Documents • 0.57 MB
Additional Documents_RANGIA TAMULPUR SS CHAPAR LINE BAY LAYOUT AND SECTION WITH WHOLE SS 31-08-26-Model.pdf
Additional Documents • 2.91 MB
Additional Documents_ROAD SECTION.pdf
Additional Documents • 0.26 MB
Additional Documents_SUB ACDB AGIA'.pdf
Additional Documents • 0.31 MB
Additional Documents_TS of 400KV CHAPAR - RANGIYA TL.pdf
Additional Documents • 0.24 MB
BOQ_84456.xls
BOQ • 1.27 MB
CORRIGENDUM_IX.pdf
PDF • 0.19 MB
CORRIGENDUM_VIII.pdf
PDF • 0.44 MB
Corrigendum_VII.pdf
PDF • 31.00 MB
400kV D Type BOM_1) 400kV DD type Basic Body BOM.pdf
PDF • 0.35 MB
400kV D Type BOM_1) BOM Basic Body with Aux Axilary X-arm DD type.pdf
PDF • 0.38 MB
400kV D Type BOM_11) 400 kV DD +25m BOM.pdf
PDF • 0.27 MB
400kV D Type BOM_2) 400kV DD type +0 BOM.pdf
PDF • 0.23 MB
400kV D Type BOM_3) 400kV DD type +3 BOM.pdf
PDF • 0.28 MB
400kV D Type BOM_4) 400kV DD type +6 BOM.pdf
PDF • 0.24 MB
400kV D Type BOM_5) 400kV DD type +9 BOM.pdf
PDF • 0.24 MB
400kV D Type BOM_6) 400kV DD type +18 BOM.pdf
PDF • 0.27 MB
400kV Stub_400kV DD+18,+25 Stub BOM.pdf
PDF • 0.21 MB
400kV Stub_400kV upto DA+9 Stub BOM.pdf
PDF • 0.21 MB
400kV Stub_400kV upto DB+9 Stub BOM.pdf
PDF • 0.21 MB
400kV Stub_400kV upto DC+9 Stub BOM.pdf
PDF • 0.29 MB
400kV Stub_400kV upto DD+9 Stub BOM.pdf
PDF • 0.21 MB
SINGLE PILE FOUNDATION.pdf
PDF • 0.25 MB
400kV A Type BOM_1) 400 kV DA Type Basic body BOM.pdf
PDF • 0.29 MB
400kV A Type BOM_2) 400 kV DA Type +0m BOM.pdf
PDF • 0.24 MB
400kV A Type BOM_4) 400 kV DA Type +3m BOM.pdf
PDF • 0.24 MB
400kV A Type BOM_5) 400kV DA Type +6m BOM.pdf
PDF • 0.25 MB
400kV A Type BOM_6) 400kV DA Type +9 BOM.pdf
PDF • 0.25 MB
400kV B Type BOM_1) 400 kV DB Type Basic Body BOM.pdf
PDF • 0.34 MB
400kV B Type BOM_2) 400 kV DB Type +0m BOM.pdf
PDF • 0.22 MB
400kV B Type BOM_3) 400 kV DB Type +3m BOM.pdf
PDF • 0.22 MB
400kV B Type BOM_5) 400 kV DB Type +6m BOM.pdf
PDF • 0.22 MB
400kV B Type BOM_6) 400 kV DB Type +9m BOM.pdf
PDF • 0.23 MB
400kV C Type BOM_1) 400 kV DC Type Basic Body BOM.pdf
PDF • 0.35 MB
400kV C Type BOM_2) 400 kV DC Type +0m BOM.pdf
PDF • 0.23 MB
400kV C Type BOM_3) 400 kV DC Type +3m BOM.pdf
PDF • 0.23 MB
400kV C Type BOM_4) 400kV DC Type +6m BOM.pdf
PDF • 0.23 MB
400kV C Type BOM_5) 400kV DC Type +9m BOM.pdf
PDF • 0.24 MB
Corrigendum_VI.pdf
PDF • 0.29 MB
Corrignedum_V.pdf
PDF • 1.12 MB
Corrignedum_III.pdf
PDF • 0.24 MB
Corrigendum_I.pdf
PDF • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .