Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹34.0 L+₹64,300 (1.93%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹34.8 L+₹1.4 L (4.22%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Recommended to open price bid since your firm not enlisted in the category of NIT ie a (i) a(ii) | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Recommended to open price bid since your firm not enlisted in the category of NIT ie a (i) a(ii) |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
26 Jun 2023, 6:00 pmClosed
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8542/E8
2023_MES_599553_1
8542/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VASCO
Class D Category b i and b iii
7 documents required · 7 mandatory
₹500
GE NW VASCO
₹64,000
Yes
7 Aug 2023
31 May 2023
28 Jun 2023
31 May 2023
26 Jun 2023
14 Jun 2023
31 May 2023 - 13 Jun 2023
Amount
M & L for loose spreading of graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard complete all as directed and as specified.
Surface dressing not exceeding 15 cm depth by removing of creepers/ vegetation on stay wires/ HT/LT/ street light poles including clearing 3 mtr all around Stay wire & pole in soft/ loose including removing to a distance n.exc 200mtrs and depositing at a level n.exc 1.5mtr above starting point complete all as specified and as directed. (Note : Each cleaning will be mesaured and paid)
Dismantling of existing old unserviceable ACSR conductor of any size of any descritpion and material and labour for providing new ACSR conductor all as specified and directed including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc for different sizes complete all as specified and as directed. Note : Rates for new Aluminium cable terminal lugs are included in this rate.
S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps, ISMB 200 X 100 x 6 mm, ISMB 150 x 100 x 6 mm etc fabricated structural steel, sections, including nuts, bolts, washers etc and cutting to required length bent to any shape drilling holes, fixed on poles or jointed by means of electric welding complete including painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces including taking down / dismantling the old items complete all as specified and as directed.
Disnmantling of existing old unserviceable earth wire and cradle guard of any size from any position, material and labour for providing new GI wire 4 mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, all as directed.
Dismantling old unserviceable stay assembly complete & material and labour for new stay assembly complete with 20 mm dia stay rod with accessories shown in electric plate No 01 including stay clamp, (loop insulator , stay wire, earthwork excavation and concrete shall be measured and paid seperately) complete all as specified and as directed.
M & L in repairs for Galvanised Stay wire of size 7/4 mm including dismantling old wire all as directed.
S & F in repairs for loop insulator Vitreous Porcolain white or brown of size 90 X 140 mm clearance hole 25.5 mm complete all as specified and as directed.
S & F in repairs of Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cut to required shape and size for cable duct or any other description complete all as specified as directed.
Repairing/Servicing the Air break isolating switch HT 33 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts nuts etc all as specified. Note :- Major spare will be measured & paid seperately under relevant item of Sch'A' item No. 11
Supply only following spares of 33 KV Airbreak switch.
Male contact/moving Contact Blade
Female contact/Fix Contact Jaw
Rotating contactor pipe 200A/400 A
MS jumper carrier
Back Connector plate
Supply & Lay , testing and commissioning XLPE, cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 33000 Volts grade (earthed), 3 core 185 sqmm laid in trenches/floor/duct/fixed on poles/through GI tubing including brass cable glands complete all as specified and as directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in getting out hard/dense soil and levelling of bottom surface to required level for laying of UG cable complete all as specified and as directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep getting out in soft/disintegrated rock and levelling of bottom surface to required level for laying of UG cable. .
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and as directed.
Supplying & Laying in trenches Clear Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified. (punned thickness of sand will be measured and paid)
Supply and lay un-reinforced precast concrete cable covers, class EHV , type- I with peak, size 300mm x 180mm x 40mm, all as specified and directed.
S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of sizes 100 mm dia as in repairs complete all as specified and as directed.
M & L for PVC insulated unarmoured heavy duty electric cable with copper conductor 1100 V grade with cross section area 4 Core 4 Sqmm complete all as specified and as directed.
M & L for PVC insulated armoured heavy duty electric cable with copper conductor 1100 V grade with cross section area 16 Core 2.5 Sqmm complete all as specified and as directed.
S & F in repairs drop out (DO) fuse unit expulsion type outdoor three pole 200 Amp suitable for HT 33 KV, comprising of insulators, steel base mounting frame , GI nut bolts etc with 30A , HT barrel type fuse complete all as specified and as directed.
S & F in repairs including testing, and commissioning of gang operated type air break switch horizontal/vertical type type mounting complete, double break and operation rod of suitable length 400 A capacity and suitable for 33 KV HT supply, complete all as specified and directed.
S & F in repairs lightning arrestor Zinc oxide gap less type, station class suitable for 33 KV/10 KA complete with all fittings all as specified and directed . (Make : M/s Crompton Greaves / M/s Lamco / M/s Elpro / M/s Oblum)
S & F in repairs single post insulator, 33 KV with mounting spindle etc. complete all as specified and as directed..
S & F in repairs Pin insulator, 33 KV with mounting spindle etc. complete all as specified and as directed.
S & F in repairs disc insulator, 33 KV with hardware fittings etc complete all as specified and as directed.
M & L preparation of old painted external surfaces of HT 2 pole structures consisting of cross arms, GOD assembly with pipe, DO fuse assembly, clamps etc., of any description and applying one coat of Aluminium paint by mannualy (Except PCC/RCC Pole) all as directed. Note for item No 29 to 31 :- This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in the structures & Each job will be measured and paid.
All as per item No 29 here in before but including Steel tubular pole or ISMB of size 150x100x6 mm 11 mtr long complete all as specified and as directed.
All as per item No 29 here in before but for 4 pole structure complete all as specified and as directed.
M & L preparation of old painted surfaces of HT 33/11 KV MRS at Hansa consisting of Steel poles / ISMBs, cross arms, GOD pipe,clamps etc., having of any description and applying one coat of Aluminium paint by mannualy (incl structure) all as directed. The approx particulars are as under :- (a) ISMB 200 X 100 x 6 mm 12 mtr height as pole - 18 Nos (b) ISMB 200 X 100 x 6 mm 2.5 to 3.5 mtr height as pole - 30 Nos (c) Angle Iron cross support 75 x 75 x 6 mm - 50 RM (d) MS Flat 50 x 4 mm - 24 Rm (e) C Channels of size 75 x 75x 6 mm - 110 RM (f) ISMB 150 x 100 x 6 mm as cross member - 284 RM Note :- (a) This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b) This painting work will be carried out during Holidays only to avoid electrical shut down.
M & L for servicing of 33 KV VCB at Hansa MRS, dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required, reassembling the VCB and reinstalling back to its original position checking and repairsing the current circuit panel wiring , relay testing and provision of minor spares as required complete including operational testing and commissoning all as directed. Note : New major spare parts will be measured and paid under Sch A item No 34.01 to 34.09.
M & L supply only of the following spares for outdoor VCB 33 KV 800 A 750 MVA fault level 36V-26/2000 make: Crompton Greaves/as approved by GE and all as directed.
Closing coil 30V DC
Tripping coil 30V DC
Anti pumping device 30V DC
33 KV porcelain bushing for VCB Top
33 KV porcelain bushing for VCB bottom
Connector strip 16 way
Earth Fault and over current relay of L & T Model No MC61A 24-110V
Digital type power factor indicator meter
Digital type Voltmeter / Ammeter 96 x 96 mm size
Supply only rubber hand gloves of 33 KV grade ISI marked.
Supply only fiber glass discharge rod in three sections and aluminium head with complete accessories suitable for 33 KV of 20 feet height.
S & F in repairs HT DO Fuse element for 33 KV system of 5 Amps.
S & F in repairs HT DO Fuse element for 33 KV system of 10 Amps.
S & F in repairs HT DO Fuse element for 33 KV system of 20 Amps.
S & F in repairs HT DO Fuse element for 33 KV system of 40 Amps.
S & F in repairs HT DO Fuse element for 33 KV system of 50 Amps.
S & F in repairs HT DO Fuse element for 33 KV system of 60 Amps.
S & F in repairs sealed maintenance free battery 2 Volts 100 Amps for UPS supply including necessary connections complete all as directed. (Exide/Amron/TATA)
M & L for taking out the MS duct cover from the cable duct chamber disconnecting the haphazardly laid serviceable HT UG cable of 3 core of 95 to 185 Sq mm from VCB/Any description taking out from cable trenches / ducts and straighten and laying in proper layers including provn of new identification tags for each cables and connecting back to its original position including cleaning the cable ducts complete all as specified and as directed.
S & F in repairs for Breather unit with superior quality blue colour silica jel, to maintain the exact value of grade for transformer of capacity 33/11 KV type 2 MVA Transformer, including taking down unserviceable complete all as specified.
S & F in repairs HV insulator with studs nut & washers suitable for 33 / 11 KV, HV side of transformer 2 MVA
S & F in repairs LV insulator with studs nut & washers suitable for 33/11 KV LV side of transformer of Capacity 2 MVA
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc mixed with 10% of paddy field earth, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
M & L for painting of HT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun complete all as specified and as directed.
M & L for removing vegetation, grass, shrubs and bushes growing in Sub station yard along with fencing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. cutting of grass is month wise measured and paid separeatly.
M & L for Cutting and trimming of tree branches 3 mtr all around of any size which is obstructing illumination of street light and touching LT / HT Over head line by using required tools and plants including removing trimmed tree branches. Rate inclusive of time loss due to stinginess in issuing power shut down. (Note : Each cleaning will be measured and paid separetely)
S & F in repairs cable jointing kit for 33KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
S & F in repairs cable jointing kit for 33KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
S & F in repairs cable jointing kit for 33KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
Carry out Material/machineries & labour for foult finding of 33 KV or 11 KV HT under ground cable of length up to 1.5 KM in case of cable foult such as short circuit/burn out/earth foult etc including carryout necessary hypot test by injection high voltage up to 50 KV complete all as specified and as directed.
S & F in repairs including testing, and commissioning lightning arrester (LA) for 33KV HT grade with nuts,bolts, washers , clams and all accessories as per sample including taking down unserviceable complete all as specified by engr- in- charge. Note :- Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
S & F in repairs including testing, and commissioning Aluminium bus bar of 32mm dia for 33KV HT grade with nuts,bolts, washers , clamps and all accessories as per sample including taking down unserviceable complete all as specified. Note :- Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
S & F in repairs including testing, and commissioning Aluminium bus bar of suitable size to match the existing for 33KV HT grade with nuts,bolts, washers , clams and all accessories as per sample including taking down old unserviceable complete all as specified. Note :- Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
Disconnecting, opening of VCB of any description and any make of rating 11 KV 400/800 Amps capacity for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in these item. (ii) Servicing shall be got carried out by the authorised rep of the VCB manufacturer and the service engineer will submit a service report for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
Supply only following items/spare parts suitable for 11KV VCB, 400/800 Amps capacity of make Crompton greaves dismantled / fixed under Sch 'A' item No: 59 here-in-before complete all as specified and directed.
Vacuum circuit breaker main mechanism assembly complete with all accessories all as specified and directed by Engr-in-Charge
Vacuum Interrupter type WL-33379 suitable for 11 KV VCB Panel complete all as specefied and directed.
Isolating contact assembly 400/800 Amps suitable for 11 KV VCB Panel complete all as specefied and directed.
Tripping Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete all as specefied and directed.
Close Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete all as specefied and directed.
Motor & Gear assembly 110V AC and 220 AC for 11 KV VCB Panel complete all as specefied and directed.
TNC switch for 11 KV VCB Panel complete all as specefied and directed.
Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commisioning and testing of cast resin type 11KV current transformer having ratio 100+50/5+5A as per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second all as specified and directed. Make: CG/Kappa/Jyoti/Alstom
Disconnecting and taking down unserviceable voltage transformer of any description and in any position and supply, installation, commisioning and testing for 11KV single phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 complete all as specified and directed. Make: CG/Kappa/Jyoti/Alstom
Taking out old but serviceable ACB of capacity 400 to 1200 amps 415 volts AC 50 HZ at various sub station and carry out necessary servicing , gresing to fixed and movable part , cleaning complete internally and testing after reinstallation. ( Any demage occures during servicing will be borne by the contractor ).
Supply and fix charging motor 110V AC/DC, 220V AC/DC of suitable size for ACB of capacity 400 to 1200 Amps complete all as specified and directed by Engr-in-charge
Supply and fix control relay for charging motor 110V AC/DC, 220V AC/DC of suitable size for ACB of capacity 400 to 1200 Amps complete all as specified and directed by Engr-in-charge
Shine Enterprises
S and G Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .