Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC reasonable | |
| 2 | L2₹9.4 L+₹29,847 (3.28%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹9.4 L+₹32,540 (3.58%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹9.6 L+₹51,641 (5.68%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹9.7 L+₹61,886 (6.80%)Rejected-Finance | L5 | Rejected-Finance HIGH RATE |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
21 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI TAPAN DAS AGE I
AGE I AF SINGARSI
CLEANING OF PVC TANK INCLUDING PLUMBING FITTINGS AND OTHER MISC WORKS AT AF STN SINGARSI UNDER AGE I AF SINGARSI
2023_MES_606883_1
C/8611/E8
Open Tender
Civil Works
Item Rate
270 days
AGE I AF SINGARSI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE I AF SINGARSI
₹18,000
Yes
2 Sept 2023
30 Jun 2023
28 Jul 2023
30 Jun 2023
21 Jul 2023
14 Jul 2023
Amount
M&L for cleaning and degermination inside the RCC/PVC water storage tanks of capacity not exceeding 500 ltr of any description and in any position comprising the following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/INCHLOR-5/NB-10, TERBAC G65/INOXI-60/NB-69 and ultra violet rays complete all as specified and as directed. (a) 1st stage: Drain out the water by using exit valve or with high capacity dewatering system or any other suitable method approved by Engr-in-Charge. (b) 2nd Stage: Cleaning all the algae formation inside the tank by using TERBAC G10/INCHLOR-5/NB-10, (a laboratory tested branded chemical) and scrubbing the walls of the tanks. (c) 3rd stage: Cleaning with fresh water by high speed jet pump with pressure of 5 PSI. (d) 4th stage: Sterilization by using TERBAC G5/INCHLOR-5/NB-10, (a Laboratory certified branded halogen compound) for first bateria screening. (e) 5th stage: Cleaning the floor of the water tank by heavy duty industrial vaccum cleaner. (f) 6th stage: Sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria for 2nd bacteria screening. (g) 7th Stage: Cleaning and sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TERBAC G65/INOXI-60/NB-69 for third bacteria screening. Note:- (i) After cleaning of the tank necessary completion certificate confirming the completion of sterilization of water tank shall be issued by the service provider and a sticker shall be fixed on the tank duly mentioning the date of cleaning and name of site etc) Note: Clause (i) applicable for work carried out under ser item no.1 to 3 for subject contract. Note:- For Srl item No 1,2 and 3 above:- (i) If any complaint regarding tank incomming pipe and outgoing pipe, discharge of water, float valve and pressure of water supply to out going pipe, overflow of tank to corresponding bldg received vide users/stn authority or by this office same shall be carried out within 24 hrs. If the contractor failed to carried out the above complaint witin the time mentioned above penality of Rs.500.00 per complaint/day shall be imposed to the contractor and recovery shall be done from the contractor. (ii) Only Date of cleaning of tank in DD/MM/YY shall be clearly mentioned and payment shall be made under respective item. (iii) Before cleaning work to be carried out contractor shall check the tank, If any breakage /crack of tank shall found ,contractor shall immediately notify to Engr in charge in written. (iv) Taking down float valve before cleaning the tank and refixing the same after cleaning of tank if any found broken/u/s same shall immediately notify to Engr in charge in written before cleaning of tank. (v) Contractor or his agent has to be reported daily at 10.30 am regarding receving the complaint and also to inform about planning of cleaning of tank to be carried out after 48 hrs.
All as per Serial item No. 01 above but PVC tank of capapcity exc 500 and n.exc 1000 Litres complete ditto.
All as per Serial item No. 01 above but PVC tank of capapcity exc 1000 and n.exc 2000 Litres complete ditto.
Demolition of cement concrete (unreinforced) in roofs, floors other than ground floors beams staircases, landing, hajjas and similar suspended work, ccomplete all as specified and as directed by Engineer-in-Charge.
M&L for PCC type B0 1:2:4 (12.5 mm Graded stone aggregate) as in roof padding, complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 15mm thick on fair faces of brick work / concrete surfaces in CM 1:4 finished even and smooth without using extra cement and mixing with WPC as per manufacturers instruction, complete all as specified and as directed by Engineer-in-Charge. Note:- WPC will be measured and paid separately.
M&L for Cleaning the roof surfaces and applying bitumen primer @ 0.30 kg/sqm, providing and laying 3mm thick APP modified water proofing membrane weighing not less than 3.00 kg/sqm reinforced with non woven polyester mat weighing not less than 160 gm/sqm, having softening point not less than 800 N /Sq cm, tearing strength of 180N, with minimum of 10 cm side laps and 15cm end laps, laying by application of torch, and applying industrial bitumen 85/25 @ 1.2 kg/sqm on top surface, complete all as specified and as directed by Engineer-in-Charge.
Supply only liquid water proofing compound.
M&L for Cleaning the roof surfaces and applying industrial bitumen 85/25 @ 1.2 kg/sqm on top surface,complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 15mm bore tubing and connections of any description including cleaning for refixing or removal to store,complete all as specified and as directed by Engineer-in-Charge.
Taking up or down 20 mm bore steel tubing and connections of any description including cleaning for refixing or removal to store
S&F for 15mm die GI tubes (medium grade) with all fitting and fixed complete to walls and ceilings or laid in floors after taking up or down old unserviceable tubing and connections.
S&F for 20mm die GI tubes (medium grade) with all fitting and fixed complete to walls and ceilings or laid in floors after taking up or down old unserviceable tubing and connections,complete all as specified and as directed by Engineer-in-Charge.
Re-fixing for 15mm die old steel tubing and connection in new or old position (wall, ceiling, floor etc) including cleaning, re-running the old threads etc complete after taking up or down old unserviceable tubing and connections,complete all as specified and as directed by Engineer-in-Charge.
Re-fixing for 20mm die old steel tubing and connection in new or old position (wall, ceiling, floor etc) including cleaning, re-running the old threads etc complete after taking up or down old unserviceable tubing and connections,complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying including all fittings of CPVC pipes SDR 11 & Plain CPVC SDR 11 of outer dia 20mm fittings on walls/ceiling or laying in floors, complete all as specified and as directed.
Supplying and laying including all fittings of CPVC pipes SDR 11 & Plain CPVC SDR 11 of outer dia 25mm fittings on walls/ceiling or laying in floors,complete all as specified and as directed.
S&F 500 Ltrs rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of multi-layer, hoisted and fixed in position all as specified in SSR Part-l, after dismantling of old water tank (PVC) and Dismantling water tanks and removing to outside defence area,complete all as specified and as directed.
S&F 1000 Ltrs rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of multi-layer, hoisted and fixed in position all as specified in SSR Part-l, after dismantling of old water tank (PVC) and Dismantling water tanks and removing to outside defence area,complete all as specified and as directed.
S& F in repair 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed,complete all as specified and as directed.
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed,complete all as specified and as directed.
S&F in repair 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed,complete all as specified and as directed.
S&F for PTMT ball valves high pressure with epoxy coated aluminium rod & high density plastic ball screwed for 20mm die pipes all as specified and directed as in repair, (minimum weight 210 gms),complete all as specified and as directed.
M/S KUMAR AVINASH
M/S SINGH ENTERPRISE
M/S MBS TRADING CO
M/S ASHA ENTERPRISE
M/S AMARNATH AGARWALLA
LALAN SHARMA
M/S New Builders Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .