Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 93 BAPUJI NAGAR ITC ROAD SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹27.2 L+₹6.7 L (32.6%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹31.5 L+₹11.1 L (53.9%)Rejected-Finance VILL ASADPUR PO SARSAWA DISTT SAHARANPUR | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-Finance Being 3rd |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
10 Nov 2021, 6:00 pmClosed
SHRI B K SREEKUMAR EE GE (AF) SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
SPECIAL REPAIR /REPLACEMENT OF ELECTRICAL FITTING AND CONCEALMENT OF WIRING IN CORRIDOR OF ADMIN AND TECH SIDE COMPLEX TO ELECTRICAL INFRASTRURE AND CERTAIN MINOR WORKS AT AF STN SARSAWA
2021_MES_473542_3
8121/SAR-48/E8 SPECIAL REPAIR /REPLACEMENT OF ELEC
Open Tender
Civil Works
Item Rate
183 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹68,000
Yes
8 Dec 2021
25 Oct 2021
12 Nov 2021
25 Oct 2021
10 Nov 2021
27 Oct 2021
25 Oct 2021 - 27 Oct 2021
Amount
Taking down carefully copper / aluminium point wiring light / fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc. removing from site and making good disturbed surface of wall, floor etc. to match with existing finish complete all as specified and directed by Engr-in-Charge.
Taking down tube light fittings / bulk head fittings / light fittings retrieved from Srl item No 1 here-in-before and kept in safe custody for re-use the serviceable fittings complete all as specified and directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm copper conductor cables single core (multistranded) FRLS PVC insulated and unsheathed in and including concealed PVC conduit of (ISI marked) 25mm dia for one Light/fan independent controlled by one, one way switch including continuous earth wire single core 1.5 Sqmm copper conductor (multistranded) FRLS PVC insulated and unsheathed cable connected to earth dolly complete all as specified conforming to IS-694 including 2 mm thick Ms sheet Metal box with earth dolly including 3 mm thick ISI marked, plastic laminated sheet for mounting switches and socket etc all concealed including finishing the disturb plaster surface and painting 2 coat of white wash/ distamper to meet the existing surface complete all as specified and directed by Engr-in-Charge.
All as per item No. 3 here in before but for one 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and directed by Engr-in-Charge.
All as per item No. 3 here in before but for one 3 pin socket outlet 5 Amps independent complete all as specified and directed by Engr-in-Charge.
Point wiring with 2.5 Sqmm copper conductor cables (multistranded) FRLS PVC insulated and unsheathed in and including concealed PVC conduit of (ISI marked) 25mm dia for one 5 pin socket outlet 15 Amps independent controlled by one, one way switch including continuous earth wire single core 2.5 Sqmm copper conductor (multistranded) FRLS PVC insulated and unsheathed cable connected to earth dolly including finishing the disturb plaster surface and painting 2 coat of white wash/ distamper to meet the existing surface complete all as specified and as directed complete all as specified conforming to IS-694.
All as per item No. 3 here in before but for one socket outlet 15 /20Amp independent using 4 Sqmm copper conductor cable single core (multi-strand) FRLS PVC insulated and unsheathed cable and 4 sqmm copper (multistrand) single core FRLS PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm including finishing the disturb plaster surface and painting 2 coat of white wash/ distamper to meet the existing surface ccomplete all as specified and directed by Engr-in-Charge.(for AC)
S&F Electronic fan regulator flush mounting 300-400 Watts switch size having 4 step to regulate/ control speed of ceiling fan complete all as specified and directed by Engr-in-Charge.
S&F switch 1 way 6A, Piano Type complete all as specifed and as directed by Engr-in-Charge.
S&F switch 1 way 16A, Piano Type complete all as specifed and as directed by Engr-in-Charge.
S&F socket 6A -2/3 pin Piano Type complete all as specifed and directed by Engr-in-Charge.
S&F socket 6A /16A- 6 pin Multipurpose Piano Type complete all as specifed and directed by Engr-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket with MCB 20 Amps 10kA 'C' curve rating capacity suitably fixed in a weather proof metal enclosure complete all as specified and directed by the Engr-in-charge.
S&F Ceiling rose, PVC / Polycarbonate 65mm x 50 mm with 3 plate three terminals, ISI Marked complete all as specifed and directed by Engr-in-Charge.
S&F batten holder pin type, PVC body ISI marked complete all as specified and as directed by Engr-in-Charge.
S&F LED lamp 9 watt Make-SYSKA -or equivalent in Havells/Bajaj/CG complete all as specified and as directed by Engr-in-Charge.
S&F LED T5 AL batten 20watt MAKE-SURYA or equivalent in Havells/Bajaj/CG as specified and directed by Engr-in-Charge.
S&F LED Bulkhead fitting 10 watt, MAKE-SURYA or equivalent in Havells/Bajaj/CG as specified and directed by Engr-in-Charge.
S&F Recess mounting 36 watt LED of size 2x2 feet slim ceiling light with extruded aluminium housing powder coated, milky diffuser, operating voltage 120V-280V, power factor>0.95, inbuilt Short circuit protection and surge protection, soft and uniform light distribution, system lumen more than 100lm/W,CRI>80, integrated constant current electronic driver with 2 year warranty all as specified and directed by Engr-in-Charge.. Make:-Philips/Wipro/Osram
S&F Surface mounting 18/20 watt LED of size 1x1 feet slim ceiling light with extruded aluminium housing powder coated, milky diffuser, operating voltage 140V-280V, power factor>0.95, inbuilt Short circuit protection and surge protection, soft and uniform light distribution, system lumen more than 100lm/W,CRI>80, integrated constant current electronic driver with 2 year warranty all as specified and directed by Engr-in-Charge.. Make:-Philips/Wipro/Osram
Replacement of existing old MH /Helogen/out dated flood light with LED flood light 150watt Rectangular LED Flood light with innovative thermal management anmultipal optics and equipped with IP66 protection complete all as specified and as directed by Engr-in-Charge.Make:-Philips/Wipro/Osram
S&F in replacement of MCB single pole of 6 to 32 Amp capacity, 'B' curve,10KA, 240 volt complete all as specified and directed by Engr-in-Charge..Make-Legrand/L&T/Siemens
S&F in replacement SPN/DP MCB 40-63 amp range10KA ,240v ac complete all as specified & Directed by Engr-in-Charge.Make-Legrand/L&T/Siemens
S&F in replacement of Sheet metal enclosure factory made shutter type for double door distribution board (when MCBs are to be used) single pole and neutral, 240 Volts, with 200 Amp rated busbar, IP 43/IK09 (MCBs are to be measured & paid separately) complete all as specified and directed by Engr-in-Charge. Make-Legrand/L&T/Siemens (Note-Make of DBs & MCB should be same) (a) 12 way
-Ditto- but 8way complete all as specified and directed by Engr-in-Charge
-Ditto- but 6 way complete all as specified and directed by Engr-in-Charge
S&F in replacement of Double door TPN prewired distribution board 4 way made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection ( Single Phase MCBs are to be measured and paid for seperately) complete all as specified and directed by Engr-in-Charge
S&F Isolater 415 V 100Amp ,16kA 4 pole complete all as specified and directed by Engr-in-Charge
S & F in Replacement of submain wiring with two single core 10 sq mm FRLS PVC insulated, unsheathed, cable 1100V grade heavy duty, copper conductor multistranded, drawn in PVC conduit, medium grade, 25 mm bore having 2mm wall thickness including one single core FRLS PVC insulated copper cable multistranded of size 10 sq mm as earth wire fix to wall etc including finishing the disturb plaster surface and painting 2 coat of white wash/ distamper to meet the existing surface complete all as specified and as directedcomplete all as specified and as directed by Engr-in-Charge. Note- Three run of cable shall be measured as single run for payment purpose.
S & F in Replacement submain wiring with two single core 6 sq mm FRLS PVC insulated, unsheathed, cable 1100V grade heavy duty, copper conductor multistranded, drawn in PVC conduit, medium grade, 25 mm bore having 2mm wall thickness including one single core FRLS PVC insulated copper cable multistranded of size 6 sq mm as earth wire fix to wall etc including finishing the disturb plaster surface and painting 2 coat of white wash/ distamper to meet the existing surface complete all as specified and as directed complete all as specified and as directed by Engr-in-Charge. Note- Three run of cable shall be measured as single run for payment purpose.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick surrounded by charcoal & salt buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of the earth plate not less than 1.5m below normal ground level, connected to main earth lead GI wire of size 4mm as earthing lead upto 7.5m length by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 including exc & earth work in any type of soil,disposal of soil, providing alternate layer of charcoal and common salt, construction of pcc earth chamber in mix 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B1 cover rein forced with 8mm dia MS bars ways with lift hook made out of 8 mm dia bar,watering arrangement with funnel and wire mesh and watering pipe of 20 mm dia GI light grade and 15mmm dia medium grade pipe for earth lead protection incl provn of test point and testing on completion complete all as specifed and directed by Engr-in-Charge at site Note:-Main earth lead beyoned 7.5 meter shall be measured and paid seperatly.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc as required 4mm galvanised iron strip complete all as specified and directed.
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 volt grade FRLS electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia concealed type including all flame proof conduct fittings and accessories such as tees junction boxes, bends duly tested by CMRI Dhanbad suitable for one light /fan point controlled by one flame proof rotary switch SP one way and including drawing continuous earth wire FRLS PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed by Engrs-in-Charge.
Supply and fixing flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc all as specified and directed. Make : Flexpro/Sudhir/Baliga/Shyam.
Supply and fix in replacement with Flame proof LED light fitting. 2x16/20W flameproof type CMRI Certifed ,Recommended for Gas/Vapour Group ofIIA & IIB and Zone 1& IP 65 Protection. made of aluminium alloy LM6, make-Crompton or Equiltent in sudhir/Baliga/Shyam etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Note :- (a) All fittings shall be ISI marked and shall have approval of CMRI Dhanbad . (b) Original Test certificate of Manufacturer shall be produced by Contractor . (c) (1) Lumens efficiency of fitting shall be minimum 90 lumens/watt. (2) PF shall be minimum 0.9. (3) THD shall be maximum 20%. complete all as specified and directed by Engrs-in-Charge.
Supply and fixing LED light fitting 1x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed by Engineer-in-charge.
Supply and fixing flame proof wall fan 415 mm sweep,RPM 1440, Single phase C.F.M. 5400 including grounting Nuts, bolts and making electrical connections with flame proof cable drawing into flame proof Conduit, complete all as specified and directed & making good to disturbed surfaces as per matching to existing. complete all as specified and as directed by Engr-in-Charge
Supply and fixing flame proof Ceiling fan 1200 mm (48") sweep, Single phase weather proof in cast aluminium LM7 including making hole, grounting Nuts, bolts , regulator and making electrical connections with flame proof cable drawing into flame proof Conduit, complete all as specified and directed & making good to disturbed surfaces as per matching to existing. complete all as specified and as directed by Engr-in-Charge
Material and labour for flameproof point wiring complete with 1.5 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core on surface in stove enamelled steel conduit not less than 20 mm complete with junction box and plate for fitting mounting flameproof switch with 1.5 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one light point controlled by one switch complete all as specified and as directed by Engr-in-Charge
Switch flame proof rotary type with termination box in LM6, 6A, single pole 250V complete all as specified and as directed by Engr-in-Charge
S&F DB DD SPN 415 Volts 4 ways double door complete all as specified and as directed by Engr-in-Charge
M&L for sub main wiring 2 run of size 1.5 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with, 1.5 sqmm PVC insulated copper conductor earth wire in concealed PVC conduit (2 run of 1.5 sqmm cable and 1 run of 1.5 sqmm wire and one run of PVC conduit will be measured as one unit) complete all as specified and as directed by Engr-in-Charge
S&F of MCB SP-6-40 Amps,240 Volt B series type complete all as specified and as directed by Engr-in-Charge
S&F of MCB SPN 40-63 Amps,240 Volt B series type complete all as specified and as directed by Engr-in-Charge
All as per item No.01 Above but One 5 pin, 5 Amps socket out let on independent board with 1.5 Sqmm cable & alongwith 1.5 Sqmm continous earth wire of copper conductor concealed in wall in medium duty PVC conduit complete all as specified and as directed by Engr-in-Charge
All as per Item No. 01 above One 15/20 Amps socket out let or for sheet metal enclosure on independent board with 4 sqmm cable alongwith 4.0 Sqmm continuous earth wire of copper conductor concealed in wall in medium duty PVC conduit complete all as specified and as directed by Engr-in-Charge
S&F Switch piano, flush type single pole, one way 5 Amp complete complete all as specified and as directed by Engr-in-Charge
S&F Switch piano, flush type single pole, one way 15 Amp complete complete all as specified and as directed by Engr-in-Charge
S&F Socket outlet 6 pin multipurpose, 15/5 Amp, flush type complete all as specified and as directed by Engr-in-Charge
S&F Socket outlet 5 pin, 5 Amp, flush type complete all as specified and as directed by Engr-in-Charge
Supply & fix PVC body exhaust fans AC single phase 230/ 240 V of size 250 mm sweep with louver for washroom complete with making arrangement for fixing of exhaust fan on steel window and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed by Engr-in-Charge
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge
Supply & fix wall mounting Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-Charge
Supply and fix electric water heater, storage type steel body with inner tank and heating element upto 2 KW capacity 10 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, SS connection piece etc. Make:- Faber, Havells/Recold complete all as specified and as directed by Engr-in-Charge
Supply and fixing LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engr-in-Charge
M&L for sub main wiring 2 run of size 4.0 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with, 4 sqmm PVC insulated copper conductor earth wire in concealed PVC conduit (2 run of 4 sqmm cable and 1 run of 4 sqmm wire and one run of PVC conduit will be measured as one unit) complete all as specified and as directed by Engr-in-Charge
Supply and lay cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 3.5 core complete all as specified and as directed by Engr-in-Charge
M&L for Straight through joints heat shrinkable for XLPE/PVC insulated and sheathed aluminium conductor under ground cable 1100 Volts 3.5/ 4 core 25 sqmm to 35 sqmm and testing after jointing complete all as specified and as directed by Engr-in-Charge
Excavation in trenches in any type of soil not exc 1.5 mtr wide and not exc 1.5 mtr deep for taking out/laying of U/G HT/LT cable and getting out the excavated soil including triming the sides complete all as specified and as directed by Engr-in-Charge
Returning, filling in, incl spreading leveling, watering and well raming in layers not exc 25 centimetre thick in layer in any type of soil complete all as specified and as directed by Engr-in-Charge
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed Engr-in-Charge.
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
Material and labour for sand cushioning with layer of dry, clean & fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed by Engr-in-Charge
Dismantling concrete poles/ struts, any size and transporting to store and stacking complete all as specified and as directed by Engr-in-Charge
Dismantling insulators any type, any siz complete all as specified and as directed by Engr-in-Charge
Dismantling of ACSR or AAC conductors complete all as specified and as directed by Engr-in-Charge
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and as directed by Engr-in-Charge
Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately) complete all as specified and as directed by Engr-in-Charge
Supply & fix bus bar chamber having four number aluminium bus bar mounted on insulator of capacity 100 Amp fixed/grouted in the PCC in with angle stand minimum height 2 feet from ground level and including PVC conduit pipe of 25 mm dia heavy duty for incoming and outgoing cable connection complete with gland complete all as specified and as directed by Engr-in-Charge
M&L in replacement of stay assembly using GI stay rod 20 mm dia complete with accessories excluding stay wire 7/4 mm dia shown in electrical plate no 1 of SSR part 1 of 2009 (loop type insulators ,stay clamps excavation, stay clamp and concrete measure separately complete all as specified and as directed by Engr-in-Charge
S&F Loop type insulator, vitreous porcelain, white, brown or green small size, with overall dimensions 65 x 90mm, clearance of hole 16m complete all as specified and as directed by Engr-in-Charge
S&F galvanised stay strand, 7/4mm complete all as specified and as directed by Engr-in-Charge
S&F in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending (cold or hot) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and as directed by Engr-in-Charge
S & F submain wiring with two single core 6 sq mm FRLS PVC insulated, unsheathed, cable 1100V grade heavy duty, copper conductor multistranded, drawn in PVC conduit, medium grade, 25 mm bore having 2mm wall thickness including one single core FRLS PVC insulated copper cable multistranded of size 6 sq mm as earth wire fix to wall etc including finishing the disturb plaster surface and painting 2 coat of white wash/ distamper to meet the existing surface complete all as specified and as directed by Engr-in-Charge
S & F submain wiring with two single core 10 sq mm FRLS PVC insulated, unsheathed, cable 1100V grade heavy duty, copper conductor multistranded, drawn in PVC conduit, medium grade, 25 mm bore having 2mm wall thickness including one single core FRLS PVC insulated copper cable multistranded of size 10 sq mm as earth wire fix to wall etc including finishing the disturb plaster surface and painting 2 coat of white wash/ distamper to meet the existing surface complete all as specified and as directed by Engr-in-Charge
S&F Double door three phase prewired distribution board 4 way made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 200 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and suitable MCCB 4 pole AMP,415 V 16KA rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately) complete all as specified and as directed by Engr-in-Charge
S&F MCCB 4pole 100 Amp 415 volt 16KA repturing capacity(for VPTN) complete all as specified and as directed by Engr-in-Charge
S&F in replacement of Sheet metal enclosure factory made shutter type for double door with acrylic window distribution board (when MCBs are to be used) single pole and neutral, 240 Volts, with 200 Amp rated busbar, IP 43/IK09 08 WAY (MCBs are to be measured & paid separately) complete all as specified and as directed by Engr-in-Charge
M&L for maintenance free chemical earthing with copper bonded (min 250 microne) electrode of dia 17.2mm (3/4") 10 feet long , bus bar 150X25X6mm exothermic welding at top of electrode, with copper strip 20X3mm upto test point as directed location & making test point with 300X25X6mm copper bus bar mounted on wall with insulated studs, electrode to be fixed in 6" dia hole 9 feet depth withfilled with chemical compound NABL lab tested 0.039 Ohm-m resistivity (test certificate to be submitted before execution of work) as per manufacturer recommendation as per IS code 3043:1987, wet side wall of earth hole, making paste with 3kg of backfill compound with 2 Ltrs of water, pouring of same paste in earth pit and place earth electrode in centre of pit, now again make paste 5kg of back fill compund with 5 liter of water and pour inside the pit repeat the process till complete pit gets covered with compound including PCC earth pit chamber 300X300X300mm with 50mm thickness (100mm above ground 200mm below ground) with top PCC cover 300X300X50mm with handle for lid for inspection of pit including embossed at top cover - 1. Pit No. , 2. Resistance value, 3 Test date & 4. Test due date complete all as specified and as directed by Engineer-in-charge(FOR UPS). complete all as specified and as directed by Engr-in-Charge
M&L for eathing copper strip 20X3mm complete all as specified and as directed by Engr-in-Charge
Point wiring with 1.5 Sqmm copper conductor cables single core (multistranded) FRLS PVC insulated and unsheathed in and including concealed PVC conduit of (ISI marked) 25mm dia for one Light/fan independent controlled by one, one way switch including continuous earth wire single core 1.5 Sqmm copper conductor (multistranded) FRLS PVC insulated and unsheathed cable connected to earth dolly complete all as specified conforming to IS-694 including 2 mm thick Ms sheet Metal box with earth dolly including 3 mm thick ISI marked, plastic laminated sheet for mounting switches and socket etc all concealed including finishing the disturb plaster surface and painting 2 coat of white wash/ distamper to meet the existing surface complete all as specified and directed by Engr-in-Charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV,SS connection piece etc complete all as specified and as directed by Engr-in-Charge Make- Havells/Recold/Bajaj
S&F DB DD SPN 415 Volts 8 ways double door complete all as specified and as directed by Engr-in-Charge
Supply & Fix 4 socket outlet with surge protection with master switch 15000Amps, Led indicator, less than 1 nano second response time for surge protection, made of fire resistant material, copper wire lead 2 meter long with plug top complete all as specified and as directed by Engr-in-Charge. Make:- Honeywell platinum model.
M&L Point wiring with 2.5 Sqmm copper conductor cables (multistranded) for one 5 pin socket outlet 5 Amps independent controlled by one, one way switch including continuous 2.5 Sqmm copper conductor (multistranded) FRLS PVC insulated and unsheathed cable connected to earth dolly including finishing the disturb plaster surface confirming to IS-694 and painting 2 coat of white wash/ distamper to meet existing Surface confirming to IS-694 comlete all as specified and as directed
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louver complete with making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed by Engr-in-Charge
BRIJ CONSTRUCTIONS
DHARAMPAL SINGH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .