| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹10.8 L+₹1.6 L (17.1%)Rejected-AOC 120 144 III PHASE APNA VIHAR JAMMU J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180010 | L2 | Rejected-AOC L2 | |
| 3 | L3₹10.9 L+₹1.7 L (18.3%)Rejected-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹11.8 L+₹2.6 L (28.0%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹12.3 L+₹3.0 L (32.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹30,500
Closing Date
4 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jammu
HQ CWE Jammu pin 900172 C/o 56 APO
REPAIR AND MAINT GOD LIGHTENING ARRESTOR AND ALLIED WORKS UNDER AGE E and M OF GE SATWARI
2021_MES_459377_1
CWE/JP-25/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR of GE Satwari
Class E, Cat b(ii)
9 documents required · 9 mandatory
₹500
GE Satwari
₹30,500
Yes
28 Aug 2021
13 Jul 2021
11 Aug 2021
13 Jul 2021
4 Aug 2021
28 Jul 2021
90 days
Amount
Supply and fixing in replacement of lightning arrestor HT 33 KV expulsion type complete with all fittings, transmission class, discharge capacity 10 KA, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement of pin/post insulator HT 33 KV with all fittings, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement of Switch air break gang operated triple pole mechanically operated from ground level, mounted on insulators and steel frame (15 insulator type) outdoor type suitable for vertical installation single break provided with locking arrangement consisting of MS channel, HT post top porcelain insulator with drop out fuses operating Rod 20mm dia GI pipe medium grade confirming to IS:1818 of 1972 and current rating 200 Amp and voltage 11 KV complete all as specified including jumpering, lead of wire/cable, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement of Switch air break gang operated triple pole mechanically operated from ground level, mounted on insulators and steel frame (15 insulator type) outdoor type suitable for vertical installation single break provided with locking arrangement consisting of MS channel, HT post top porcelain insulator with drop out fuses operating Rod 20mm dia GI pipe medium grade confirming to IS:1818 of 1972 and current rating 400 Amp and voltage 11 KV complete all as specified including jumpering, lead of wire/cable, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement of Switch air break gang operated triple pole mechanically operated from ground level, mounted on insulators and steel frame (09 insulator type) outdoor type suitable for horizontal installation single break provided with locking arrangement consisting of MS channel, HT post top porcelain insulator with drop out fuses operating Rod 20mm dia GI pipe medium grade confirming to IS:1818 of 1972 and current rating 400 Amp and voltage 11 KV complete all as specified including jumpering, lead of wire/cable, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement of Switch air break gang operated triple pole mechanically operated from ground level, mounted on insulators and steel frame (09 insulator type) outdoor type suitable for horizontal installation single break provided with locking arrangement consisting of MS channel, HT post top porcelain insulator with drop out fuses operating Rod 20mm dia GI pipe medium grade confirming to IS:1818 of 1972 and current rating 400 Amp and voltage 33 KV complete all as specified including jumpering, lead of wire/cable, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement of aluminium conductor steel reinforced (ACSR) of size 54/7 x 3.18mm (Panther) including stretching on overhead line on 33 KV steel structures to required sag and binding with aluminium binding with fixing arrangements with T clamps, tension fittings and isolator clamps as per Panther conductor in 33 KV sub Stn, with nuts and bolts etc to include aluminium conductor Panther) bus bars, jumpering the OH line, jointing, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement of 12 KV lightning arrestor station class 10 KA complete all as specified and as directed.
Supply and laying synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for elecrical purpose as per IS :15652-2006, (superseding IS-5424) suitable for electrical shock safety of sizes 2m x 1m in front of HT panels, under GOD complete all as specified and as directed.
Supply and laying synthetic rubber insulated mats 3 mm thick for voltage upto 33 KV for elecrical purpose as per IS :15652-2006, (superseding IS-5424) suitable for electrical shock safety of sizes 2m x 1m in front of HT panels, under GOD complete all as specified and as directed.
Surface excavation not exceding 30 cm deep in any type of soil and averaging 15 cm deep and getting out green vegetation, roots, bushes, etc surrounding of 2 / 4 / 6 pole structure / substations / Panels complete all as specified and as directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
Supply and spreading 20mm graded crushed stone coarse aggregate in 33/11 KV switch yards, two pole/four pole structures, 11 KV Sub Stns, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement anti climbing device, spikes type, fabricated out of MS bars (round, square or flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the poles, spike welded to flat iron, including on primer coat, one under coat and two finishing coats of silver aluminium paint including preparation of surfaces, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement pin/post insulator HT 11 KV complete with all fittings, complete all as specified and as directed by Engr-In-Charge
Supply & fixing in replacement of male contact (moving contact blade) as per sample approved by GE suitable for 11 KV 400 Amp rating GOD including cable lead/wires, thimbles and connected items etc, complete all as specified and as directed by Engr-In-Charge
Supply & fixing in replacement of female contact as per sample approved by GE (fixed contact jaw) suitable for 11 KV 400 Amp rating GOD including cable lead/wires, thimbles and connected items etc, complete all as specified and as directed by Engr-In-Charge
Supply & fixing in replacement of tinned copper flexible jumper suitable for 11 KV 400 Amp rating GOD, complete all as specified and as directed by Engr-In-Charge
Demolition of Cement concrete (unreinforced) in four pole / two pole / HT & LT pole / panel / approach path to sub station (below or above ground level) and removing all the demolished material outside defence area, complete all as specified and as directed by Engr-In-Charge
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc, complete all as specified and as directed by Engr-In-Charge
Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping of poles etc including necessary form work, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for LT 440 volt of size 20x15cm, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for HT 11000 Volt of size 25x20cm, complete all as specified and as directed by Engr-In-Charge
Material and Labour in replacement of Earthing complete with galvanised steel earth plate 600 x 600 x 6mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI strip 25x3mm by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 kg/Sqm with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc complete all as specified and directed. (Length of GI earth strip & Protection pipe is up to 7.5 RM including) Complete all as specified and as directed. Contd to Srl Item No 24.01
Note : - If extra soil is required in earthing it shall be provided by contractor and cost of the same is deemed to be included in quoted rates.
Material and Labour in replacement of Earthing complete with galvanised steel earth plate 600 x 600 x 6mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI wire of size 4 mm by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 kg/Sqm with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc complete all as specified and directed. Contd to Srl Item No 25.01
Note : - If extra soil is required in earthing it shall be provided by contractor and cost of the same is deemed to be included in quoted rates.
Supply and fixing in replacement of GI strip 25 x 3 mm including clamps, nut, bolt, washers etc, complete all as specified and as directed by Engr-In-Charge
Supply and fixing in replacement of GI wire 4mm dia along the pole, wall, floor etc all as directed by Engr-in-Charge.
Supply and fixing cross Arms, bracings, supports, clamps etc fabricated from steel including nuts, bolts, washers, welding, bending, drilling holes for bolts in any shape or size as directed inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including dismantling of old cross arms, complete all as specified and as directed by Engr-In-Charge
bamral builder
SATISH AND CO
LAL CONSTRUCTIONS
M/S S K Electricals Regd
M/S ASHOK KUMAR SURI
R K BUILDERS
SUMEET TRADING CORPORATION
kailu construction co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .