Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC AT BAGHUABOL CHHAK PO HATATOTA TALCHER ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L1 | Accepted-AOC The amount quoted by L1 bidder M/s Industrial Engineering Works is 23.16 percent below the estimated cost / 23.16 percent below the updated cost. | |
| 2 | L2₹10.3 L+₹64,650.10 (6.71%)Rejected-Finance AT GURUDHWAR NEAR UCO BANK SOUTH BALANDA TALCHER DIST ANGUL ODISHA PIN 759116 | TALCHER | ANGUL | ODISHA | 759116 | L2 | Rejected-Finance On being L2 |
Tender Value
₹14.8 L
EMD Value
₹18,500
Closing Date
28 Mar 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Vijay Kumar Staff Officer(EnM) Lakhanpur Area
Vijay Kumar Staff Officer(EnM) Lakhanpur Area GM Office Bandhabahal Dist-Jharsuguda Odisha-768211 Mob-9437595715
Repairing overhauling and replacement of spares of 33 KV MOCB make- ESWARAN, 33KV SF-6 ABB make breaker at BOCM, Lakhanpur Area.
2023_MCL_275052_1
MCL/LKPA/EnM/eNIT/22-23/155 dt-13.03.2023
Open Tender
Electrical and Maintenance Works
Item Rate
21 days
Belpahar OCM, Lakhanpur Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹18,500
29 Apr 2023
13 Mar 2023
31 Mar 2023
13 Mar 2023
28 Mar 2023
14 Mar 2023
13 Mar 2023 - 17 Mar 2023
Amount
Repairing/Overhauling , maintenace & testing of 33 KV MOCB make ESWARAN,sl no 5961023, newly supply and fixing of 33 KV lighting surge Arrestor , Current Transformer, Potentional Transformer & SF-6 of ABB make spares fitted and testing work in substation of 33 KV incoming 1 & 2 circuit, and overhauling of AB Switch of both the yard and Bus coupler of Transformer and 33KV relay panel switch repairing and testing.
S&F of Ammeter 96/120 sqmm 40/5 Amps, 33 Kv 110 V
S&F Indicating lamp with holder
S&F TNC switch
S&F moving contract tip assembly
S&F moving contract Rod assembly
S&F contract fixed upper assembly
Complete set of Baffles with Tubular sleeves & partion set consists (a)Top Baffels assembly (b) Partition lower Baffels (c) Intermediate Baffles (d)Tubular Sleeves ,
S&F of Tripping coil 48 V DC
S&F of Closing coil 48 V DC
Supply&fixing of Insulatr gasket
Supply&fixing of oil seal
Supply&fixing of Gasket plate
Supply&fixing of Auxillary contator 240 V SC
Supply&fixing of Nuts & Bolts with washer
Dismantling of 3 pole insulator 06 nos, Rupturing chamber 03 nos moving & fixed contact including Bus bar pipe
Cleaning of the a rupturing chamber & their Baffles moving
contact rod, fixed contact including assly the above Aligment of the moving contact rod with fixed contact of connecting rod of all 03 poles
dismantling of the oil tank & its mechanism including fitting of the (a)Oil tank & its mechanism after cleaning & greasing (b)Drainage of carboised oil & pouring the treated oil in all 3 poles
Realigment of the oil tank mechanism & spring charing gear system
Dismantling, repairing, mechanism operation charging closing tripping motor & changing proper mechanism functioning tripping and testing commissioning
Repairing/Overhauling , maintenace & testing of 33/3.3 KV Relay control Panel of Substation
S&F Voltmeter PTR 33 KV /110 V
S&F Ammeter CTR 50/5 AMP
S&F COS Q Mtr CTR/5 AMP, PTR/110 V
S&F KVAR mtr CTR 50/5 Amp OTR 33 KV/ 110 V
Earth leakage relay with CBCT
Repairing, cleaning & maintenance of 33 KV relay panel of indoor type breaker with control relay panel including charging, closing and tripping system of mechanism units etc.
Dismantling, maintenance & installation of HT protective and metering accessories with checking of ITC power circuit and control circuit and necessary spares for smooth operation .
Testing of control circuit and protective devices for smoothly working to ensure the affectiveness wheather the breakers are tripping during faulty condition.
33 KV incomer Feeder 1&2 spares of SF-6 station surge arrestor, current transformer and potentional transformer & rep/maint./ OH of AB switch in S/S yard.
S&F 33 KV station surge Arrestor/Suppressor Rating- 36 Kv LD class-2, PR Class-A/30 KA, COV-25.5 KV,
S&F of current Transformer type-GWT 0/33-3,Rating-70/170 KV, ratio-100/5-5-5 A HTC-17.5 KA/3 sec,HSV-36 KV, TH/DY-43.7 KA
S&F 33 KV Potential Transformer 33KV/ꝩ3, 110 V/ꝩ3,
S&F of Bus Coupler for 33 Kv Transformer
S&F CLOSE/TRIP Coil 110 -220V DC
S&F TRIP 1 COIL 110-220V DC
S&F TRIP 2 COIL 110-220V DC
S&F Spring charging motor 220V AC-DC
Auxillary contactor 110 V DC
Auxillary switch assly 16 way
Local Remote switch
Limit Switch with roller (4NOS)
Overhauling kit of pole column for 1 breaker
SF-6 gas cylinder 4 kg
SF-6 gas interconnecting pipe with NW8 connector
TNC switch
Damper
Nuts, Bolts, washers, PVC tape, Copper control Lugs & other necessary as required
Repairing, cleaning & maintenance of 33 KV, 1600 Amps, outdoor type, SF-6 breaker with control relay panel including charging, closing and tripping system of mechanism units etc.
Dismantling, maintenance & installation of HT, CTs, PTs, protective and metering accessories with checking of ITC power circuit and control circuit and necessary spares for smooth operation of VCB panel etc.
Control circuit opening of old MOCB /VCB with complete control circuit wiring, cable termination from control relay panel to SF-6 breaker etc.
Testing of control circuit and protective devices for smoothly working to ensure the affectiveness wheather the SF-6 breakers are tripping during faulty condition.
For the 33 KV/3.3 KV Breaker Andrew Yule make spares.
S&F power factor COS Ꝋ mtr/P.F mtr, CTR/5 A , PTR/110 V
S&F MW/KWH mtr, 0-3.5 KV
S&F Of TNC switch
S&F shunt trip coil assly
S&F closing coil assly
S&F Auxillary contactor 3 NO + 3 NC
Repairing, cleaning & maintenance of 33 KV, , indoor type, breaker with control relay panel including charging, closing and tripping system of mechanism units etc.
Testing of control circuit and protective devices for smoothly working to ensure the affectiveness wheather the breakers are tripping during faulty condition.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/s Evergreen Electrical Works
stage.html
html • 0.04 MB
techsummary_284711.pdf
PDF • 0.34 MB
finsummary_284711.pdf
PDF • 0.60 MB
LOA155.pdf
PDF • 0.62 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .