Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC SHIVSHAI PUNARVASAN PRAKALP BLDG NO 10 ROOM NO 115 MAHARASHTRA NAGAR MANKHURD E MUMBAI 400088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹39.4 L+₹1.0 L (2.67%)Rejected-Finance B 20 H 1 PANCHANANTALLA ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹43.4 L+₹5.1 L (13.2%)Rejected-Finance 25A KUSTIA ROAD KOLKATA 700 039 | KOLKATA | WEST BENGAL | 700039 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.5 L+₹8.1 L (21.2%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹47.0 L+₹8.7 L (22.6%)Rejected-Finance 00 RAJ ENTERPRISE NEAR SUB JAIL SEMARVAV GIR SOMNATH SEMARVAV JUNAGADH GUJARAT 362150 | GIR SOMNATH | GUJARAT | 362150 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY SYSTEM AT EAST GATE, GEORGE GATE, VATIKA, VIJAY SMARAK, P-1 BLDG UNDER GE (FW) KOLKATA
2022_MES_499849_2
8812/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender document
6 documents required · 6 mandatory
₹500
GE(FW) Kolkata
₹70,000
10 Mar 2022
21 Feb 2022
2 Mar 2022
21 Feb 2022
28 Feb 2022
21 Feb 2022
60 days
Amount
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed.
Excavation of trench in road/hardstanding etc, not exc 1.50 m wide and not exc 1.50 m deep and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed.
Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M & L for hardcore of gauge exc 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 using 40 mm graded crushed stone aggregate complete all as specified and directed by the Engineer-in-Charge.
M&L for dry sand cushioning/sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. NOTE: Punned thickness only shall be measured for payment)
Supply and laying bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 50 Sqmm, 3.5 core
70 Sqmm to 120 Sqmm, 3.5 core
150 Sqmm to 185 Sqmm, 3.5 core
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) complete all as directed by the Engr-in-Charge of the following sizes :- Note : Necessary earth work shallo be measured and paid separately under respective items.
10 sqmm 3.5/4 core to 16 Sqmm, 3.5/4 Core
25 Sqmm to 50 Sqmm, 3.5 core
70 Sqmm to 120 Sqmm, 3.5 core
150 Sqmm to 185 Sqmm, 3.5 core
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole complete of the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm, 4 core
16 sqmm, 4 core
25 Sqmm, 3.5 core
35 Sqmm, 3.5 core
50 Sqmm, 3.5 core
95 Sqmm, 3.5 core
120 Sqmm, 3.5 core
185 sqmm, 3.5 core
S&F heat shrinkable straight through Joints using suitable jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :-
upto 16 sqmm, 3.5/4 core
25 sqmm to 50 sqmm, 3.5/4 core
70 sqmm to 150 sqmm, 3.5 core
185 sqmm to 240 sqmm, 3.5 core
S&F in repair MCCB, 4 pole, 50 KA, with thermal magnetic release, 630 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM94104OOT1OG / LEGRAND, Cat No: 4220 23 / HAGER, Cat No; HMJ631DE / SCHNEIDER, Cat No: LV563319 / C&S, Cat No: CSCS630EM6304P)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 400 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM94103OOR1OG / HAGER, Cat No: HMJ401DR / SCHNEIDER, Cat No: LV540319 / LEGRAND, Cat No: 4220 21, C&S, Cat No: CSE3N400ATM4P-400)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, range 315 - 320 amps, Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM98403OOQOOG / HAGER, Cat No: HNJ321DR / SCHNEIDER, Cat No: LV540308 / LEGRAND, Cat No: 4220 06 / C&S, Cat No: CSE3N400ATM4P-320)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 250 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM92109OOP1OG / HAGER, Cat No: HNT251DR / SCHNEIDER, Cat No: LV525343 / LEGRAND, Cat No: 4202 49 / C&S, Cat No: CSCN250EM2504P)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic release, 200 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM92109OON1OG / HAGER, Cat No: HNT201DR / SCHNEIDER, Cat No: LV525342 / LEGRAND, Cat No: 4202 48 / C&S, Cat No: CSE2NN250ATM4P)
S&F in repair MCCB, 4 pole, 36 KA, with thermal magnetic, 160 Amps, Ics=100% of Icu, 415 Volts AC with all accessories incl taking down existing MCCB complete all as specified and directed. (Make: L&T, Cat No: CM92108OOM1OG / LEGRAND, Cat No: 4200 97 / HAGER, Cat No: HNS161DR / SCHNEIDER, Cat No: LV516343 / C&S, Cat No: CSE2NN250ATM4P-160 )
S&F in repair MCCB 4 pole 36 KA with thermal maganetic release range 100 Amps Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make : L&T, Cat No : CM97919OOK2OG / LEGRAND, Cat No: 4200 95 / HAGER, Cat No: HNS101DR / SCHNEIDER, Cat No: LV510347 / C&S, Cat No: CSE1NN125ATM4P-100)
S&F in repair MCCB 4 pole 36 KA with thermal maganetic release range 63 Amps Ics=100% of Icu with all accessories incl taking down existing MCCB complete all as specified and directed. (Make : L&T, Cat No : CM97919OOH2OG / LEGRAND, Cat No: 4200 93 / HAGER, Cat No: HNS064DR / SCHNEIDER, Cat No: LV510345 / C&S, Cat No: CSE1NN125ATM4P-63)
S&F 100 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor complete,as in repairs, all as specified and as directed by the Engineer-in-charge.
S&F 80 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor complete, as in repairs, all as specified and as directed.
S&F 50 mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor or fixed along pole for cable/earth strip protection with proper size clamps, nuts & bolts for fixing ightning conductors complete, as in repairs, all as specified and as directed.
Material & Labour for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-2 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge.
S&F PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs incl taking down existing cable, as in repairs, complete all as specified and as directed.
S&F cable route indicator (blue in colour) for LT UG cable of 1100 volts, with embossed letters, min 80 mm dia, made from 5 mm thick cast iron plate 80 mm dia, bolted with 40 x 40 x 6 m angle iron of height 0.60 mtr above GL, embedded in PCC (1:3:6) type C2 (using 40 mm graded aggregate) of size 200 x 200 x 200 mm block, including taking down old unserviceable one, complete all as specified and directed. (NOTE: Cost of PCC is deemed to be included in quoted rate)
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling hole for bolts, in any shape of size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint incl dismantling of existing unserviceable cross arms complete all as specified and as directed.
S&F in repairs Street light junction box made out of 3 mm thick mild steel sheet including applying two coats of synthetic enamel paint over a coat of zinc chrome primer duly spray painted of size not less than 25 cm x 20 cm x 10 cm with locking arrangements inclusive of 20 x 3 mm thick aluminium bus bar 100 amps - 04 Nos of suitable length incl MCB SP 5 amp - 01 No, fixed on and including insulators for mounting bus bar (with provision of cable entry and exit conduit), fixed with necessary flat iron clamp of size 25mm x3 mm 2 Nos (length as reqd to fix in pole), bent to required shape including painting, at bottom portion of the pole (above coping), fixed with GI bolts, nuts and washers (of suitable size) complete all as specified and as directed.
Dismantling carefully serviceable isolating LT panel board of size 1500 mm x 900 mm x 600 mm to 2500 mm x 2000mm x900 mm, duly unscrewing/opening front and back cover and cleaning complete bus bar chamber, tightening all the nuts, bolts, incoming and outgoing terminals including cleaning all the switchgear/accessories and replacement of cable gland and replacement of stainless steel hinges of size 100mm for panel board door, fixed with welding machine incl applying one coat of synthetic enamel paint externally to panel board after scrubbing/cleaning the surface including reconnecting the panel and testing to the entire satisfaction of the engineer-in-charge. (NOTE: Cost of nuts, bolts, wahers, screws, stainless steel hinges, colour tape for bus bar, recharging and testing shall be deemed to be included in the quoted rates)
-ditto- but panel of size 500 x 500 x 500 mm to 1500 x 900 x 600 mm complete
Taking out unserviceable LT panel board (of any size) and Supply, install, commissioning and testing of indoor type LT panel board, cubical type, dust and vermin proof, made out of 2.0 mm thick CRCA sheet of size 2000 mm x 1800 mm x 600 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each ACB/MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of four numbers copper bus bar of 1000 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS channel 75 x 40 mm complete including earthing all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
Motorised Change Over Switch, open execution type, 415V, 3 phase, 630 Amps, 4 Pole with AST controller with wire harness - 01 Nos (Make: L&T, Cat No: CK90167BOOO & CK90192OOOO or equivalent model in other makes specified in tender)
MCCB, 4 pole, 50 KA, thermal magnetic release, 630 Amps, Ics=100% of Icu, 415 Volts AC - 02 No. (Make: L&T, Cat No: CM94104OOT1OG / HAGER, Cat No: HMJ631DE / SCHNEIDER, Cat No: LV563319 / LEGRAND, Cat No: 4220 23 / C&S, Cat No: CSCS630EM6304P)
MCCB, 4 pole, 50 KA, thermal magnetic release, 400 Amps, Ics=100% of Icu, 415 Volts AC - 01 No. (Make: L&T, Cat No: CM94103OOR1OG / HAGER, Cat No: HMJ401DR / SCHNEIDER, Cat No: LV540319 / LEGRAND, Cat No: 4220 21 / C&S, Cat No: CSE3N400ATM4P-400)
MCCB, 4 pole, 36 KA, thermal magnetic release, 315-320 Amps, Ics=100% of Icu, 415 Volts AC - 01 No. (Make: L&T, Cat No: CM98403OOQOOG / HAGER, Cat No: HNJ321DR / SCHNEIDER, Cat No: LV540308 / LEGRAND, Cat No: 4220 06 / C&S, Cat No: CSE3N400ATM4P-320)
MCCB, 4 pole, 36 KA, thermal magnetic release, 250 Amps, Ics=100% of Icu, 415 Volts AC - 01 No. (Make: L&T, Cat No: CM92109OOP1OG / HAGER, Cat No: HNT251DR / SCHNEIDER, Cat No: LV525343 / LEGRAND, Cat No: 4202 49 / C&S, Cat No: CSCN250EM2504P)
MCCB, 4 pole, 36 KA, thermal magnetic release, 200 Amps, Ics=100% of Icu, 415 Volts AC - 01 No. (Make: L&T, Cat No: CM92109OON1OG / HAGER, Cat No: HNT201DR / SCHNEIDER, Cat No: LV525342 / LEGRAND, Cat No: 4202 48 / C&S, Cat No: CSE2NN250ATM4P)
CT's ratio 630/5A - 03 Sets (Set of 03)
MCB, 10 kA, SP, 6-32 Amps - 03 Nos
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Sets
Spare compartment with adequate capacity copper busbar for spare MCCBs - 04 Nos
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All ACB, MCCB & Changeover to be connected internally with suitable size of copper strip.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
RAY STANDARD ENGG CO.
SIMPLEX DRILLING COMPANY
MS AP CONSTRUTION AND CO
RAJ ENTERPRISE
GHOSH ENTERPRISE
M A ENTERPRISES
PRABIR TRADERS
ARJUN DAS VALECHA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .