Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.7 CrAccepted-AOC 701 HEADQUARTERS SANT DNYANESHWAR MARG CHETANA COLLEGE ADJUNCT BANDRA EAST MUMBAI 400051 | MUMBAI SUBURBAN | MAHARASHTRA | 400051 | ₹91.7 Cr | L1 | Accepted-AOC Being the lowest tenderer (L1) and reasonable |
| 2 | L2₹104.4 CrRejected-Finance | ₹104.4 Cr | L2 | Rejected-Finance Not being lowest. |
| 3 | L3₹107.8 CrRejected-Finance | ₹107.8 Cr | L3 | Rejected-Finance Not being lowest. |
| 4 | L4₹124.2 CrRejected-Finance | ₹124.2 Cr | L4 | Rejected-Finance Not being lowest. |
| 5 | L5₹126.7 CrRejected-Finance | ₹126.7 Cr | L5 | Rejected-Finance Not being lowest. |
Tender Value
₹100 Cr
EMD Value
₹15 L
Closing Date
26 Apr 2021, 6:00 pmClosed
CE (Navy) Mumbai
HQ CE (Navy) Mumbai, 26 Assaye Building, Colaba, Mumbai-400005
PROVISION OF DEFICIENT OFFICERS MARRIED ACCOMMODATION 120 DUs AT COLABA MUMBAI
2021_MES_415218_1
87883/E8
Open Tender
Civil Works
1095 days
GE (P) (NW) Mumbai
Please refer Tender documents
8 documents required · 8 mandatory
₹3,000
GE (P) (NW) Mumbai
₹15 L
Yes
HQ CE (Navy) Mumbai
30 Oct 2021
22 Jan 2021
28 Apr 2021
22 Jan 2021
26 Apr 2021
5 Mar 2021
9 Feb 2021
Amount
Schedule-A' Part-I 'Buildings & Structures' Total of Schedule-'A' Part-I B/F from serial page No. 33(R)
Schedule-A' Part-II 'Excavation, Earthwork, Site Clearance' Total of Schedule-'A' Part-II B/F from serial page No. 35(R)
Schedule-A' Part-III 'Demolition / Dismantaling' Total of Schedule-'A' Part-III B/F from serial page No. 36
Schedule-A' Part-IV 'Internal Water Supply' Total of Schedule-'A' Part-IV B/F from serial page No. 38
Schedule-A' Part-V 'Internal Electrification' Total of Schedule-'A' Part-V B/F from serial page No. 42(R)
Schedule-A' Part-VI 'LIFTS' Total of Schedule-'A' Part-VI B/F from serial page No. 43(R)
Schedule-A' Part-VII 'Fire Fighting' Total of Schedule-'A' Part-VII B/F from serial page No. 47
Schedule-A' Part-VIII "Lightning Protection" Total of Schedule-'A' Part-VIII, B/F from serial page No. 48(R)
Schedule-A' Part-IX "DG Set " Total of Schedule-'A' Part-IX B/F from serial page No. 49
Schedule-A' Part- X 'Compound wall & Gate' Total of Schedule-'A' Part- X, B/F from serial page No. 51
Schedule-A' Part-XI 'Road / Paths / Hardstanding' Total of Schedule-'A' Part-XI B/F from serial page No. 53
Schedule-A' Part-XII "SEWAGE DISPOSAL" Total of Schedule-'A' Part-XII B/F from serial page No. 55
Schedule-A' Part-XIII 'Area Drainage' Total of Schedule-'A' Part-XIII B/F from serial page No. 57
Schedule-A' Part-XIV 'External Water Supply' Total of Schedule-'A' Part-XIV, B/F from serial page No. 60
Schedule-A' Part-XV 'External Electrification' Total of Schedule-'A' Part-XV, B/F from serial page No. 62
Schedule-A' Part-XVI "Aviation Light " Total of Schedule-'A' Part-XVI B/F from serial page No. 63
Schedule-A' Part-XVII "ARBORICULTURE" Total of Schedule-'A' Part-XVII B/F from serial page No. 64(R)
SCH 'A' PART-XVIII (MISCELLENEOUS ITEMS)
INTERNAL WATER SUPPLY
Providing, fixing, testing and commissioning of CP brass swan neck sink cock with wall flange and swinging casted spout with 6 LPM flow rate as/GRIHA requirement complete as required and making good the walls wherever required.
Providing, fixing, testing and commissioning of 15 mm dia CP brass bib cock with export pettern & with hose union for washing machine with CP wall flange and with flow rate as/GRIHA requirement of approved quality complete as required and making good the walls wherever required
Providing, fixing, testing & commissioning of water regulating angle valve with CP wall flange etc. complete as required and making good the walls wherever required.
Providing, fixing, testing and commissioning of CP Brass 115mm long Shower Arm with wall flange and pressure adjustable Shower Rose with 6 LPM flow rate as/GRIHA requirement complete with all accessories as required and making good the walls wherever required.
Providing, fixing, testing and commissioning of CP brass bath and shower mixer with wall flange and with flow rate as/GRIHA requirement complete with all accessories as required and making good the walls wherever required.
Providing, fixing, testing & commissioning of ABS body (push type) Health faucet of 5 LPM flow rate as/GRIHA requirement with wall hook and 1.2 metre SS braided rubber hose pipe complete as required and making good the walls wherever required.
S&F two way bib cock 20 mm dia. Make - Jaquar Model No CQT-23041 or equivalent as given in Particular Specifications.
Providing and fixing, testing and commissioning of pressure regulating valve (PRV) for water supply line. PRV is tested to a pressure not less than 15.0 kg/cm2 and suitable to reduce the pressure as desired, including flanges/unions, nuts, bolts and washers complete as required for application.
20 mm dia
25 mm dia
40 mm dia
50 mm dia
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
25mm dia nominal bore
65 mm dia nominal bore
75mm dia nominal bore
100mm dia nominal bore
"INTERNAL ELECTRIFICATION"
S &F Modular Electronic 2M chine ding dong AC-230 Volt, Make :Legrand cat No 57333 of Havells cat no AHFCEEW060
S &F TV Socket ( Similar to 5734 25 of Legrand or Equal) all as specified and as directed.
S & F modular type 1 module RJ 11 telephone socket with shutter complete all as specified and directed.
S& F Modular type 25A SP 'C' MINI MCB breaking capacity 10 KA of rating all as directed. Make : Havells model No :- DHFNCSPA025 /L&T/ ABB/schneider( For AC)
S& F Modular Socket 25 A shuttered Socket all as directed. Make : Havells model No :- AHFKCXW253 /L&T/ ABB/schneider (For AC)
S&F Energy efficient BEE five star rated ceiling fan, 1400 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed.Make : HAVELLS Cat No :- XP-390 Crompton Greaves/ Bajaj/Orient
S&F Energy efficient BEE five star rated ceiling fan, 1200 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed.Make : HAVELLS Cat No :- ES Neo Crompton Greaves/ Bajaj/Orient
S&F Exhaust fan 230 mm sweep Metallic body Range complete and shutters including required length and size of copper stranded conductor for connection from ceiling rose to connector of fan with provn of making hole in wall complete with grouting of nuts, bolts and washers and all other accessories required for fixing of fan including testing on completion.Make , - Havells cat no :- Ventil Air -DB Neo / Bajaj/Crompton
S&F of Exhaust fan aluminum louvers size 300x300mm with provn of making hole in wall complete with grouting of nuts, bolts and washers and all other accessories required for fixing of fan including testing on completion all as specified and directed.
S&F Fresh air Exhaust fan of size 200 mm sweep PVC body complete with and shutters including required length and size of copper stranded conductor for connection from ceiling rose to connector of fan with provn of nuts, bolts and washers and all other accessories required for fixing of fan including testing on completion Make , - Havells cat no :- Ventil Air -DX White / Bajaj/Crompton
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromental friendly Energy efficient ready to use pack ,1x20 Watt ,4 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos etc. make-HAVELLS LHEXBLP7PN1W020/WIPRO /JAQUAR /PHILLIPS
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack ,1x10 Watt ( for mirror light),2 feet,surface mounting type extruded pvc, snap on installers and domestic electronic Driver ,connector block ect.with all assoceries intenallt prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nosetc all as specified and as directed. make- HAVELLS Cat no :- LHEXBPNIN1W010/WIPRO / /JAQUAR /PHILLIPS
S&F lamp holder PVC/polycarbonate with back plate suitable for angle batten fittings including LED lamp 9 watt complete all as specified and as directed.
S & F 10/12W Ceiling surface mounted decorative LED Light fixtures all assoceries internally prewired & including conecting up with 2 core flexible copper conductor cable with sutable size & mounting clamps etc all as specified and as directed. Make ;- Crompton Cat No LCSR-12-CDL/Havells INTEGRANEO SURFACE DLS 10W LED or equivalent Philips/Wipro/CG/ Bajaj Make
S&F deep drawn Rugby bulk head fitting 9/10 watt cast aluminium housing& foosted glass. Body epoxy white powder coated heat resistant prismatic glass cover with specially designed gasket complete all as specified and as directed. Make : Crompton Cat No ; LBHE-10CDL/Havells/SYSKA
S & F 1 X 40W LED light fittings surface mounted type in IP 66 Enclosure for Parking and podiums with electronic LED driver, connector block etc. with all accessories internally prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc. Havells MAGNUM GRAND GOLD or equivalent Philips/Wipro/CG/ Bajaj Make
S & F LED Security/Street light fittings 25 Watt wall mounting type extruded metal/aluminium body, and electronic LED driver, ect. with all accessories internal prewired & including connecting up with 2 core flexible cppper conductor cable with suitable size etc and fix GI pipe bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15w ssecurity light fitting all as specified and as directed. Make- HAVELLS Cat No ; ENDURAPEARLSL25WLED757SASYTOPC / WIPRO / /JAQUAR /PHILLIPS
Supply & Installation of 1000 mm wide Class A min. 2.0 mm thick rubber matting of approved make as per IS 15652 : 2006 (up to 3.3 kV) all as specified and as directed.
S&F for MCB TPN 415 Volts, 'C' series , breaking capacity 10KA of rating 40Amps all as directed.Make L&T cat no :- BB40400C/Havells/schneider/ ABB
S&F for MCB TPN 415 Volts, 'C' series , breaking capacity 10KA of rating 32 Amps all as directed.Make L&T cat no :- BB40320C/Havells/schneider/ ABB
S&F for MCB TPN 415 Volts, 'C' series , breaking capacity 10KA of rating 63 Amps all as directed.Make L&T cat no :- BB40630C/Havells/schneider/ ABB
MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating all as directed. Make L&T cat no BB10060C to BB10320C /Havells/ schneider/ ABB
MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 32Amps all as directed. Make L&T cat no BB20320C /Havells/ schneider/ ABB
MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps all as directed. Make L&T cat no BB20400C /Havells/ schneider/ ABB
S & F Geyser BEE 5 star rated, 25 Ltr capacity incl grouting nut bolt of suitable size and making good surface all as specified and as directed. Make:- Havells cat No (Quatro)GHWEQTTIB025/Bajaj/Venus/Racold
Supply, installation, testing and commissioning of sandwich type (3L + N + PE), busbar trunking system complete with two runs of 50 mm x 6 mm aluminium earthing strip and accessories all as specified and directed. Make: L&T/Schneider/ABB/Siemens The busbar trunking system shall conform to the following technical specifications:
[A] General: [i] The busbar trunking system (BTS), both feeder and plug-in, shall be of sandwich construction. All components and fittings (straight length, elbow, tees, flanged ends, cable tap box and circuit breaker, etc.) shall be in accordance with IEC 61439 Part 6 (2012) or UL857 and from the same manufacturer as the busbar trunking system. Degree of protection of the BTS shall be IP 65 in accordance with IEC 60529. [ii] Rated operation voltage of the BTS shall be 1 kV. The neutral conductor shall have the same cross-sectional area as the phase conductor. The earth busbar must be one continuous piece without bolting on housing.
[B] Certificate: [i] The busbar, of full range and each rating, shall pass full type tests specified in IEC 61439-6. The certificate shall be issued by an international independent testing authority (e.g. ASTA, KEMA, UL). [ii] A product safety mark (e.g. KEMA-KEUR, ASTA DIAMOND, UL) shall be on the product offering a visible assurance to all of full product safety testing, factory inspection and ongoing surveillance under independent authority to ensure the ongoing safety of product. [iii] The BTS shall pass seismic tests with actual physical product and being certified complying with UBC seismic Zone 5 condition by an international recognized earthquake research body, e.g. Asian Pacific Network of Centers for Earthquake Engineering Research (ANCER). The OEM shall also furnish a certificate to confirm taht the BTS assembly is capable of withstanding the additional vibration in shaft owing to air movements.
[C] Short-Circuit Ratings & Tests: [i] The whole BTS shall be capable of withstanding the short circuit of the electrical installation without undergoing any electrical, mechanical and thermal stress under fault condition at a service voltage of 1 kV at 50 Hz frequency. The minimum rated insulation voltage shall be 1 kV. [ii] The Minimum certified short circuit withstand capacity for 400 A rating shall be 25 kA for 1 set [iii] The Minimum certified short circuit withstand capacity for 800 A rating shall be 50 kA for 1 set [iv] The Minimum certified short circuit withstand capacity for 1250 A rating shall be 65kA for 1 set [v] The Minimum certified short circuit withstand capacity for 2000 Arating shall be 80kA for 1 set
[D] Housing: [i] The busbar trunking housing shall be constructed of 1.6 mm thick electro- galvanized steel and aluminum to reduce hysteresis and eddy current loses and shall be provided with a suitable protective finish of ANSI 49 grey epoxy paint. [ii] The busbar trunking housing shall be totally enclosed non-ventilated for protection against mechanical damage and dust accumulation. And it shall pass at least 2000 hr salt spray test to ensure the anticorrosion ability. [iii] The totally enclosed housing shall be manufactured by the BTS OEM and modifications of busbar trunking to make it totally enclosed by housing other than the busbar trunking OEM shall be unacceptable without the written consent of the manufacturer.
[E] Busbars: [i] Busbars shall be of aluminum with copper cladding utilized Molecular Fusion technology. [ii] There shall be no bolts passing through the busbars of the busway. [iii] Each busbar shall be insulated with Class B (130 ℃) DuPont Mylar insulation. Epoxy insulation is unacceptable. [iv] The temperature rise at any point of the busbar trunking enclosure shall not exceed 55° C above the ambient temperature of 40° C when operated at rated current.
[F] Joints: [i] The busbar trunking joint shall be of the one-bolt type which utilizes a high strength steel bolt(s) and Belleville washers to maintain proper pressure over a large contact surface area. [ii] The bolt shall be torque indicating and at earth potential. [iii] The bolt shall be two-headed design to indicate when proper torque has been applied and require only a standard long handle wrench to be properly activated. [iv] Access shall be required to only one side of the busbar trunking for tightening joint bolts. [v] It shall be possible to remove any joint connection assembly to allow electrical isolation or physical removal of a busbar trunking length without disturbing adjacent busbar trunking lengths.
[G] Plug-in Openings: [i] The connecting jaw of the plug-in unit shall plug directly on to the busbar and have full contact with busbar itself. Welded tab at plug-in busbar is unacceptable. [ii] All contact on joint and plug-in opening should be silver plated copper. [iii] On plug-in busbar trunking there shall be three dead front, hinged cover type plug-in openings on each side. [iv] All openings shall be usable simultaneously. [v] Busbar trunking shall be installed so that plugs are side mounted to permit practical use of all plug-in openings. [vi] It shall be possible to inspect the plug-in opening and busbars prior to the installation of the plug-in units.
[H] Plug-in Units: [i] The plug-in jaw shall be spring design composed of different metal to ensure the firm and tight contact with the busbar. [ii] Plug-in Units shall be type tested in accordance with IEC 61439-6 (Annex D: Part 1-5 and 9-13). [iii] The earthing contact of the plug-in unit shall always be made before that of the live conductors and the last to break during removal. And it must connect to the earth bar of busway to ensure the safety. [iv] Covers of all plug-in units must have interlocks to prevent the cover from being opened when the switch is in the ON position. [v] Plug-in units (circuit breaker type or fusible switch type) shall be operated with visible blade quick-make and quick-break mechanism. [vi] Presence of transparent shield shall be inside to avoid direct contact of human. [vii] The plug-in units shall be equipped with internal barriers to prevent accidental contact of fish tape and conductors with live parts on the line side of the protective device during time of wire pulling.
[I] Supporting Structure: (i) Support structure shall be provied as per OEM's recommendation. (ii)Indoor feeder and plug-in busbar trunking shall be approved for hanger spacing of up to 3 meters for horizontally mounted run and 4.88 meters for vertically mounted runs. Outdoor feeder busbar trunking shall be approved for spacing of up to 1.5 meters for horizontally or vertically mounted runs. [J] Voltage Drop: [i] The voltage drop (sending end voltage minus receiving end voltage) specified shall be based on the busway operating at full rated current and stabilized operating temparature in [ii] The 3-phase line to line voltage drop 40% power factor concentrated loadshall not exceed 3.4 V per hundred ft. [iii] The line-to line voltage drop at the load power factor shall not exceed 4.1 V per hundred feet.
(K) INSPECTION / SUPPORT OF INSTALLATION (i) The installation of BBT shall be executed by skilled professionals with minimum experience of 4 yrs. Having sufficient installation base and pre- commissioning experiences. (ii) The entire installation shall be directly supervised by the OEM. (iii) The OEM shall be also fuenish a commissioning report underlining satisfactory installation after the commissioning of BBT system 800 A BBT
1000 A straight Run feeder (IP54 Protection)
630 A straight Run feeder (IP54 Protection)
400 A straight Run feeder (IP54 Protection)
Flange End with Equilizer/ Shorting plate
Horizontal/ Vertical Bend
Plug-in-point
Vertical Spring Hanger /Fix Hanger
Expansion Joint
Tinned copper braided Flexibles with Hardware- Nuts&Bolts
Adapter Box
End Feed Unit with 1000A ,415V,35kA,50Hz,FP MCCB STANDERD PLUG-IN-BOX/TAP -OFF UNIT WITH FP, 4P MCCB
SUPPORTING STRUCTURE Horizontal Fixing Clips
Supply & Installation testing and commissioning of plug in type FP Tap off boxes conforming to IS:8623-2 and IEC:439-2 complete with FP MCCB of following capacity for tapping power from rising main with solid connection, rotary operating mechanism with locking arrangement, earthing etc all as specified and as directed.(Each Floor)
(i) 4 Pole MCCB (35 kA) 200 Amps Tap Off Box
(ii) 4 Pole MCCB (35 kA) 125 Amps Tap Off Box
(iii) 4 Pole MCCB (35 kA) 100 Amps Tap Off Box
Notes :(i) The fabrication of bus duct/rising mains shall be taken up only after actual measurement and site routing. Necessary bends/transposition pieces/ expansion joints shall be estimated & included. Payment will be made on running meter basis.(ii)Test for purity of Aluminium/conductivity shall be carried out by third party. The contractor shall have to arrange the same at his cost.
Supply, installation, testing and commissioning of following Inverter system for a constant secondary voltage of 240 volts at 50 Hz, single phase, batteries backup of minimum 90 minutes duration including, SMF batteries, battery chargers, rectifiers, transformers, controls, protection and instruments etc. complete as required. Cost to include battery stand/rack, interconnecting cables etc all as specified and as directed.
2500 VA (with battery backup of 310 AH at 12 Volts or equivalent)
5000 VA (with battery backup of 625 AH at 12 Volts or equivalent)
METER BOARDS
Supply, installation, testing and commissioning of wall/floor mounted meter boards fabricated out of 16 gauge CRCA painted sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels, T irons, flats wherever necessary for large meter boards. Cable gland plates shall be provided at top and bottom both and toughened glass windows for meter reading, locking arrangement (seal) with wiring upto KWH meter & meter to MCB/MCCB shall be done by using flexible single core copper wire same size as of submain . The scope doesnot include supply of KWH meter, only space provision & associated work to be considered.
The boards shall be treated with all anticorrosive process before painting as per standards with 2 coats of red oxide primer & final approved shade of enameled paint or powder coated as approved, 2 nos. earthing terminals shall be provided for 3 phase meter boards and to be connected with the earthing of rising mains by 2 nos. 25 X 6mm GI strips. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Boards shall be fabricated in length, height, depth etc. to match with site conditions. The minimum cross-section of busbars shall not be less than 150sqmm unless otherwise specified. Metering (KWH meter) compartment shall be minimum 400X400mm
An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shall be used in fabrication of boards. Metering Panel Type # 1 ( Typical Floor) Incoming Bus bar link works to receive 4C - 25 Sq. mm Al Arm Cable incoming cable from tap off box. Indication Lamp Outgoing Space only for 3 Phase Smart Digital Energy Meter (Space Only) (4 No) 40 Amps 2P MCB (10 kA) (C - Curve) (4 No) Enclosure Fabrication, 100 Amps, 4P Aluminum Bus Bar, PVC Sleeving, Control / Power wiring & hardware. (1 Set)
Supply, installation, testing and commissioning of wall/floor mounted meter boards fabricated out of 16 gauge CRCA painted sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels, T irons, flats wherever necessary for large meter boards. Cable gland plates shall be provided at top and bottom both and toughened glass windows for meter reading, locking arrangement (seal) with wiring upto KWH meter & meter to MCB/MCCB shall be done by using flexible single core copper wire same size as of submain . The scope doesnot include supply of KWH meter, only space provision & associated work to be considered.
The boards shall be treated with all anticorrosive process before painting as per standards with 2 coats of red oxide primer & final approved shade of enameled paint or powder coated as approved, 2 nos. earthing terminals shall be provided for 3 phase meter boards and to be connected with the earthing of rising mains by 2 nos. 25 X 6mm GI strips. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Boards shall be fabricated in length, height, depth etc. to match with site conditions. The minimum cross-section of busbars shall not be less than 150sqmm unless otherwise specified. Metering (KWH meter) compartment shall be minimum 400X400mm
Metering Panel Type # 2 ( Refuge Floor) Incoming Bus bar link works to receive 4C - 25 Sq. mm Al Arm Cable incoming cable from tap off box. Indication Lamp Outgoing Space only for 1 Phase Smart Digital Energy Meter (Space Only) (3 No) 40 Amps 2P MCB (10 kA) (C - Curve) (3 No) Enclosure Fabrication, 100 Amps, 4P Aluminum Bus Bar, PVC Sleeving, Control / Power wiring & hardware. (1 Set)
Supply and Fixing of following sizes of GI Perforated type cable trays made out from 2 / 2.5 mm thick GI sheet mounted on wall / suspended from ceiling with necessary bends, tees, reducers, couplers, dashfastners, GI nuts bolts including cutting, bending, drilling, bolting, structure steel, supporting arrangements etc. and as approved by the Project Manager. Only factory fabricated accessories shall be used. Note :- Supporting arrangement shall be of same finish as that of cable tray . Supporting hangers shall be fully threaded G.I rods of following size :
(I) 50mm x 150mm x 50mm x 1.6mm, 1800mm C/C in approved manner.
(II) 50mm x 300mm x 50mm x 1.6mm, 1800mm C/C in approved manner.
(III) 50mm x 450mm x 50mm x 1.6mm, 1800mm C/C in approved manner.
Supply and Fixing of following sizes of GI ladder type cable trays made out from 2 / 2.5 mm thick GI sheet mounted on wall / suspended from ceiling with necessary bends, tees, reducers, couplers, dashfastners, GI nuts bolts including cutting, bending, drilling, bolting, structure steel, supporting arrangements etc. complete as per specifications and as approved by the Project Manager. Only factory fabricated accessories shall be used. Specification to be referred for supporting structure. Note :- Supporting arrangement shall be of same finish ( Powder coated ) as that of cable tray . Supporting hangers shall be fully threaded G.I rods of following size :
(i) 300 mm wide Runners 25 x 75 x 25 x 2.0 mm Rungs 20 x 50 x 20 x 2.0 mm 250 mm C/C
(ii) 450 mm wide Runners 25 x 75 x 25 x 2.0 mm Rungs 20 x 50 x 20 x 2.0 mm 250 mm C/C
(iii) 600 mm wide Runners 25 x 75 x 25 x 2.0 mm Rungs 20 x 50 x 20 x 2.0 mm 250 mm C/C
(iv) 750 mm wide Runners 25 x 75 x 25 x 2.0 mm Rungs 20 x 50 x 20 x 2.0 mm 250 mm C/C
(v) 900 mm wide Runners 25 x 75 x 25 x 2.0 mm Rungs 20 x 50 x 20 x 2.0 mm 250 mm C/C
Supply, installation, testing and commissioning of Din Rail mounted, self-powered direct connect AMR watt-hour meter, conforming to IEC 62053-21, with accuracy Cl 1.0 to provide direct measurement of real energy 2 Module (kWh) on a single phase network (92 VA to 276 VAC) up to Imax = 40 A, frequency range 50/60 Hz, operating temperature range -25° C to 55° C with a 6+2 digit display for measurement up to 999999.99 in kWh and for configuration and equipped with a flashing red indicator to check the accuracy of the meter. The meter shall communicate via a Modbus RS-485 protocol and all measured values shall be available via the Modbus control. The meter shall be equipped with anti-tamper security feature to ensure the integrity of the measurement complete all as specified and directed. Make:- L&T Cat No. WD4000101OOO/ABB/HAVELLS
LIFTS
Supply, Installation,Testing & Commissioning of Electric Traction Type fully automatic with Machine room Elevator with AC variable voltage & variable frequency drive unit suitable for operation on 415V, 3 Phase, 50Hz. AC supply, power operated central opening/two-panel center opening type car and landing doors, electro-magnetic brake system, two numbers of operating panel with luminous button , overload warning indicator, battery operated alarmbell, emergency light, infra red ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at ground floor, digital car position indicator in car (at all floors) with up/down direction, light fixtures, ventilation fan, main beam in shaft for machine, pit ladder and with Automatic Rescue Device (ARD) complete and as under provisions: - Make: SCHINDLER, OTIS, MITSUBISHI, HITACHI, THYSSENKRUPP
Capacity - 16 passengers (1088 Kgs) Speed - 2.5 mps Rise - 103.35m (Approx) No. of stops & openings - 34 - 34 Control system - ACVVVF-Regenarative Operation System - Duplex Operation Machine System - PM Gearless Motor Machine Location - Top of Lifts Shaft Car size - As per IS/NBC (Vary from Vendor to Vendor) Interior - S/S Grade 304-N Automatic centre opening doors 900-1000 mm wide Operation - Microprocessor based single automatic push button/quadruplex full collective with / without attendant, group operation control for four lifts. ARD for emergency operation Gong for landing in lobby Car Position indicator Hall button Car operating panel Counter weight provision
Display inside the car Intercom Facility Ready for software integtation (with BMS & FAS System) Handrail - SS mirror finish on rear wall only Car ceiling type & finish - CD41 - SS hairline finish Ceiling interior and LED light fixture shall be in scope of vendor as per OEMs design Infra Red protection for door opening & Closing On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator. Controller: A.C. variable voltage & variable frequency Power- 415 V, 3 phase, 50 Hz, 4 wires system. Type of doors - SS hairline finish Car Power operated, centre opening horizontal sliding SS Hair line finish Landing doors : Stainless Steel Should have regenerative drives to save electricity
Note: Additional load of 200kg shall be considered for Interior Designing. Operation / Grouping: Full Collective Other General Requirements Emergency Light and Alarm Bell Over Load Indicator (Visual & Audible) 3 Way Build in Intercom with EPABX System Fireman Switch in Ground Floor Automatic rescue device (Access Hatch to be consider for each lift for emergency rescue) Car Announcement system Digital indicator with direction of travel indicator in car. Direct Axial 3 speed Fan in Car, with auto switch off if no call is made for 120 sec Self Levelling- ±5 mm Elevator ceiling height – min. 2600mm. Initial inspection by lift manufacture. Passenger Elevator as described above Make: SCHINDLER, OTIS, MITSUBISHI, HITACHI, THYSSENKRUPP
Design, Fabrication, Supply, Installation,Testing & Commissioning of Electric Traction Type fully automatic with Machine room Elevator with AC variable voltage & variable frequency drive unit suitable for operation on 415V, 3 Phase, 50Hz. AC supply, power operated central opening/two-panel center opening type car & landing doors, electro-magnetic brake system, One number of operating panel with luminous button , overload warning indicator, battery operated alarmbell, emergency light, infra red ray sensing door protection for full height, reverse phase relay on controller, digital car position indicator in car (at all floors) with up/down direction, light fixtures, ventilation fan, main beam in shaft for machine, pit ladder, simplex automatic & manual dual controlled operation and with Automatic Rescue Device (ARD) complete as under provisions: - Make: SCHINDLER, OTIS, MITSUBISHI, HITACHI, THYSSENKRUPP
Capacity - 1088 Kgs (Fire Elevator) 16 passenger Speed - 2.5 mps Rise - 106.45m (Approx) No. of stops & openings - 34 - 34 Car size - As per IS/NBC (Vary from Vendor to Vendor) Control system - ACVVVF-Regenarative Operation System - Simplex Operation Machine System - PM Gearless Motor Machine Location - Top of Lifts Shaft Interior - Hairline SS Flooring - As per OEMs design Automatic centre opening doors 1000 mm wide Landing doors : Stainless Steel ( On Ground Floor) and MS Painted on Above floors Operation - Simplex
Other General Requirements Gong for landing in lobby Car Position indicator, as per ID Hall button, as per ID Car operating panel, as per ID Display inside the car, as per ID. Intercom Facility Ready for software integration (with BMS & FAS) Ceiling interior and light fixture shall be in scope of vendor, as per ID. Direct Axial 3 speed Fan in Car, with auto switch off if no call is made for 120 sec Infra Red protection for door opening & Closing Self Levelling- ±5 mm Elevator ceiling height – min. 2600mm. Initial inspection by lift manufacture. Fire Elevator as described above
FIRE FIGHTING & FIRE DETECTION WORKS
PUMP ROOM EQUIPMENT
M & L for ISI marked MS ERW pipes conforming to IS: 1239 (Part 1 & 2) with all accessories like all fittings including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer, including supporting/fixing the pipe on floor/wall/ceiling with clamps, hangers, angles, channels (using anchor fastners) with painting of one coat primer and 2 or more coats of synthetic enamel paint complete all as specified and directed
NOTES: - [i] Standard MS fittings with welded joint shall be used on the pipes. [ii] All hangers, clamps, brackets etc. shall be of galvenized iron. [iii] Welding of any kind on the galvenised support / hanger shall not be permitted. [iv] The pipe size 150 mm NB & below shall be MS 'C' class as per IS 1239 (Part- 1): 2004 & IS 1239 (Part- 2): 2011. [v] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001. [v] Pipes of size more than 50 mm NB shall be butt welded with fittings of equal or higher thickness whereas pipes below 50 mm NB size shall be socket welded. Make: Tata, Jindal, BST
HYDRANT SYSTEM
S & F gunmetal fire hydrant single landing valve with 63 mm NB flanged inlet, brass spindle controlled 63 mm NB female instantaneous outlet type gunmetal coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290- 1993 including fixing and flanged tapping from stand post type fire hydrant complete all as specified and directed. Make: Newage, AAAG, Minimax
S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed by engineer-in-charge. Make: Newage, AAAG, Minimax
S & F non-percolating rubber reinforced lined RRL hose type- A 15 m long fire hose of 63 mm NB size, conforming to IS 636: 1988, rated for bursting pressure of 35.7 kg/cm² complete with gunmetal male & female coupling conforming to IS: 903- 1993, bound and rivetted to the hose pipe with copper rivets and 1.5 mm² copper wire complete as specified and directed. Make: Newage, AAAG, Minimax
S & F branch pipe, conforming to IS 903: 1993, having 63 mm NB instantaneous gunmetal inlet, made threaded outlet, 15 mm NB long nozzle, suitable for inter connection to hose pipe coupling complete all as specified and directed. Make: Newage, AAAG, Minimax
S & F swinging type 36 m long First Aid Hose Reel, conforming to IS:884-1969, having 19 mm NB thermoplastic reinforced hose reel tubing, conforming to IS: 12585- 1988, 25 mm NB ball valve, stop cock, terminating with gunmetal coupling & nozzle of 6 mm NB outlet with shut-off valve, conforming to IS: 8090- 1976 complete with MS socket for tap-off, red colour drum, brackets (including painting) for fixing on wall with anchor fastner, bolts, nuts, etc. complete all as specified and directed. Make: Newage, AAAG, Minimax
Supply, installation, testing and commissioning of 4- way fire brigade inlet connection, conforming to IS: 5290- 1993, with four 63 mm NB inbuilt gunmetal non-return valves, four 63 mm NB instanteneous couplings arranged on 150 mm NB pipe manifold and connected to fire hydrant ring main and fire hydrant wet riser pipe all complete as specified and directed. Make: Newage, AAAG, Minimax
AUTOMATIC SPRINKLER SYSTEM
M & L for installation 150 mm NB sprinkler drawn valve, UL listed of cast iron body, brass / bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. all complete as specified and directed by engineer-in-charge.
M & L for FM approved and UL listed standard response, standard coverage glass-bulb type spray sprinklers, conforming to IS 15105: 2002, and having discharge coefficient K = 8.0, maximum working pressure 175 psi (12.1 bar), bronze frame, brass/copper button, bronze compression screw, copper defletor, TEFLON sealing assembly, etc. with 15 mm NB screwed emd connection, suitable for 68° C temperature rating complete all as specified and directed by engineer-in-charge. Make: Tyco, HD, Viking
Pendent Sprinkler
Upright Sprinkler
Sidewall Sprinkler
Sidewall extended throw Sprinkler
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
Providing, fixing, testing & commissioning of annunciater Panel, suitable for 25 zones (17 working and 8 spare), for flow control switches, providing Audio/visual Indication of actuation of Automatic sprinkler system for each zone complete as per specifications. The panel should have interface for connection to complete controlled building management system. The panel should have : a) Fault indication for each zone. b) indication of zone fire c) Fire/fault hooter. d) Alarm Panel for fire/fault. e) Battery for emergency. f) Battery charger. g) Mains supply.
Supply, installation, testing & commissioning of 25 mm dia inspecting & testing assembly with gunmetal isolation valve, gunmetal sight glass, bypass valve & connected to drain line complete (excluding the cost of drain pipe).
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 3.0 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667 of not more than 0.667 and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ''ABC' stored pressure type Dry chemical powder (Mono-Ammonium Phosphate) fire extinguisher with fixing hangers, hose, brackets, screws to required size etc., complete as per IS:15683, 4.0 Kg.
Supply, fabricating and fixing of hot dip mild steel sleeves (IS:1239 Part-I) heavy class cutting to sizes, drilling welding fixing to insert plates as per drawings and specification issued by Engineer in charge. Before finaling, the vendor should take prior approval from Engineer in charge.
100 mm dia
150 mm dia
Providing and fixing 25mm dia MS conduit of 16 SWG ISI marked (15:9537-1981, Part-11) complete with all fittings viz. tees, bends, junction boxes, clamps/supports etc. To be concealed in slabs/brick work as required or surface laid. (Exact quantities will be measured as per site conditions)
Providing and laying 2 x 1.5 mm2 FRLS insulated ISI marked copper control cable in MS conduit (IS:694) from individual flow switches from towers & stilt floor ceiling to annunciation panel installed in fire control room including sleeves cable clips, supports for horizontal runs etc. complete of size (Exact quantities will be measured as per site conditions).
Providing and fixing 6 mm thick orifice plates of brass for 80 mm dia pipes with central hole of required dia as per TAC design having a projected identification tag duly marked with 'K' factor complete in all respect.
Supply, installation, testing & commissioning of 100 mm dia pressure regulating valve (PRV) for fire line. PRV is tested to a pressure not less than 25.0 kg/cm2 and suitable to reduce the pressure as desired, including flanges/unions, nuts, bolts and washers complete as required for application.
Supply & placing 4 Bucket set of 9 Ltr. Capacity with MS Stand and fills with sand complete in all respect. Intelligent type addressable Fire Alarm system NOTE :- (a)The Fire Panel shall also be interfaced with the ventilation & pressurization System (b)Contractor need to submit the system Architecture and Riser diagram. (c)Panel should work satisfactorily at voltage 240V+/-10%
M&L of Addressable-Multi Sensor DETECTOR Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination.
M&L of Addressable-Heat DETECTOR Detectors Complying with and type certified to EN - 45 Addressable type heat detector with base with rate of rise cum fixed temperature as per lS:2175
M&L Short circuit isolators complete all as specified
M&L Remote response indicators complete all as specified
Supply, installation, testing & Commissioning of micro processor based 2 wire fault tolerant loop, 12 loop networkable type (each loop accessing minimum 125 detectors and 125 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 8 hours with battery charger complete as required including 16 Channel Integrated Digital Voice Evacuation and Two Way Fire Fighter Telephone communication System capable of supervision of all the speaker circuits, with required suitable digital amplifiers, mic and acessories required to compelete the system. The system shall be of the same make as the panel and shall be UL Listed. The system shall also have capability to be integrated with EPBAX. NOTE-The panels shall be Networked with each other .The panel shall be complete with all accessories as required for detection, PA & hooter, talk back as per norms and complete as required.
Supply, installation, testing & commissioning of Intelligent Network Repeater Panel with minimum 10" Color Touch Screen display, mapping minimum 2,00,000 points on network. The NRP shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of NRP operation. UL and FM Approved
Supply, laying including termination with proper connection & temination of wiring with 2 x 1.0 sqmm PVC insulated solid copper conductor FRLS 660/1100 volts grade wires in conduit complete as required. Note:-The conduit and it's accessories measured and paid separately
Supply, installation, testing & commissioning of 2c x 1.5 sq.mm Fire Survival Circuit Integrity unarmoured cable of 300/500V rated with Class-2 annealed copper conductor having crosslinkable ceramified Silicon insulation as per BS EN 50363 along with drain wire, aluminium tape screening and LSZH outer sheath. Should comply to EN 61034-2 & EN 60754-1. Should meet fire performance circuit integrity test as per BS EN 50200 & BS 6387 CWZ (950 Deg. C for 3 hrs). Outer sheath should be in red colour. Cable shall be laid in conduits. Make :- Finolex/RR cable/ Polycab
Fire Fighter's Telephone Supply, installation, testing and commissioning of recess/surface mounting intelligent analogue addressable Fire Fighter's Telephone Module/ jack with stainless steel face plates for connections of Fireman's handsets including the cost of supplying all the required control modules, mounting accessories and and complete as required.
Supply ,installation,testing and commissioning of 2 way communication Fire Fighter's handset complete as required.
Supply and Fixing Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
20mm dia
25mm dia
32mm dia
Supply and Fixing Junction boxes (1 to 4 way)
20mm dia
25mm dia
32mm dia
M & L for Construction of fly-ash brick masonary valve chamber of size 1000 mm X 800 mm X 1000 mm (internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Pressurisation (Axial Flow Fans)
35000 CFM; SP 35 mm of wg; Power 15 KW for Liftwell Pressurization all as specified and as directed.
Ducting
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required all as specified and as directed.
Dampers/Grilles
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications all as specified and as directed.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with louvers but without volume control dampers complete as required all as specified and as directed.
Electrical Control Panel
Cables
Supplying, laying, testing and commissioning of XLPE insulated 3 C x 6 Sq. mm copper conductor armored cables of 1.1 KV grade of following sizes directly on wall/structural frame/ cable trays or racks using approved type of clamps, With/ Without End terminations with Double Compression type glands on both ends, double earthing with GI strip/wire of suitable size and hardware as per specifications including termination of cables to feeders all as specified and as directed.
GI perforated Cable tray to carry Cables from panel to Fans , all inclusive Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc all as specified and as directed.
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and laying of the following earthing clamped to wall with suitable clamps saddles and fixing bolts/ in ground including the cost of digging and back filling as required and complete as required to comply with IS 3043:1987. All copper joints shall be tinned. The rates shall be inclusive of making test joints where ever required
25 mm x 6 mm GI strip
8 SWG GI Wire
LIGHTNING PROTECTION
TIER I- AIR TERMINATION/DOWN CONDUCTORS / RING CONDUCTORS/TESTING / DISCONNECTING LINK/EARTHING SYSTEM
Supply,Installation,Testing & Commisioning of 1 metre Vertical Aluminium Air terminal of dia 16mm to meet the requirement of IS/IEC 62305.Tested for Electrical, Mechanical, Environmental test and should have Impulse current withstand capability of 100KA (Class H)and as per IEC 62561-1&2.
Supply,Installation,Testing & Commisioning of Aluminium Air terminal base for dia15mm,1 meter long Air terminal to meet the requirement of IS/IEC 62305 .Tested for Electrical, Environmental test and should have Impulse current withstand capability of 100KA (Class H)and as per IEC 62561-1&2.
Supply,Installation,Testing & Commisioning of 25x3mm Aluminum Tape Conductor with fixing accessories and should be tested for electrical resistivity test , Tensile strength, Environmental Test (salt spray & humidity test) to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.
Supply,Installation,Testing & Commisioning of Aluminum Square Tape Clamp for Cross connection and T connection of 25x3mm Aluminium Tape should be tested for electrical resistivity test ,Environmental Test (salt spray & humidity test),Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.
Supply,Installation,Testing & Commisioning of U bolt rebar to Cable Clamp should be tested for Environmental Test (salt spray & humidity test),Contact resistance test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.
Supply,Installation,Testing & Commisioning of 50sq mm Green/Yellow PVC insulated Copper cable with terminal Lug, should have Each stranded of 1.7 mm diameter as per requirements of IS/IEC 62305 and IEC 62561-2:2012.
Supply,Installation,Testing & Commisioning of Bi-metallic Connector should be tested for Environmental Test (salt spray & humidity test), Contact resistance test, Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.
Supply,Installation,Testing & Commisioning of Test link should be tested for Environmental Test (salt spray & humidity test),Contact resistance test, Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.
Supply,Installation,Testing & Commisioning of Copper Square Tape Clamp for Cross connection and T connection of 25x3mm Aluminium Tape should be tested for electrical resistivity test ,Environmental Test (salt spray & humidity test),Mechanical test and Impulse current withstand capability of 100KA (Class H)to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.
AVIATION LIGHT
Supply and fixing aviation light luminaire,LED type 9 W IP 65 protection yellow painted die-cast of aluminium alloy housing with red colored polycarbonate double dome enclosure including provn of nuts, bolts and washers and all other fixing accessories required for fixing of light including testing complete all as specified. Make :- Bajaj Cat No BJAOL2BC-GLS 2X100 BC or equivalent make in Philips, C&S etc.
DG SET
Supply, installation, testing and commissioning of silent DG Set, conforming to IS: 10002- 1981, complete with Diesel Engine of suitable BHP & AC Brushless SPDP alternator, conforming to IS: 13364- 1992, mounted on a common base frame & coupled through a flex disc complete with platform, control panel having meters, sound-proof canopy, etc. of capacity 160 kVA complete all as specified and directed. Make: Kirloskar, Crompton Greves,Ashok Leyland,Mahindra
[a] Engine: 4/6 cylinder, in-line, 4 stroke, radiator cooled engine, well designed air handling system with dry type, heavy duty, replaceable paper element air cleaner with restriction indicator, air to air aftercooling, optimised turbocharger for increased altitude,Inline fuel pump with A1 class mechanical governing, spin on fuel filter, standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature, full flow spin on lube oil filter, electrical starter motor with soft start engagement feature, battery charging alternator with 1 X 12 V DC battery. [b] Alternator: Brushless type, screen protected, revolving field, self-excited alternator, conforming to IS/IEC 60034-1 3-phase reconnectable winding with 12 terminals brought out for connection, dedicated winding specially designed for single operation, impregnation on all wound components for better mechanical strength. [c] Control Panel: Manufactured with 14/16 gauge CRCA sheet and powder coated for weather-proof and long lasting finish. The control panel consists of the following parts: [i] Controller: Aluminum bus bars with suitable capacity with incoming/outgoing terminals [ii] Indicating lamps for ‘Load ON’ and ‘Set Running’
[iii] Instrument fuses duly wired and ferruled [iv] MCCB of suitable rating with overload and short circuit protections, 200 amps 415V TP MCCB-02 Nos [d] Microprocessor based generator set monitoring and control system including an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics, LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps, remote START-STOP [e] Engine Metering: Oil pressure, engine temperature, starting battery voltage, engine running hours [f] AC Alternator Metering: L-L voltage and L-N voltage, current (phase and total), kVA (phase and total) and frequency [g] Engine Protection: Low lube oil pressure, high/low coolant temperature, battery over/under/weak volts, fail to crank/start, sensor failure, cranking lockout, low fuel level [h] AC Alternator Protection: Over/under voltage, over/under frequency, loss of AC sensing. [i] Data Logging: Engine hours, control hours and upto 5 recent fault codes [j] Configurable glow plug control [k] 12 V DC operation
[l] Silencer: Critical grade silencer suitably optimized to meet stringent noise emission standards laid down by MoEF / CPCB [m] Mounting Arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. [n] Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning (h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
ROAD / PATHS / HARDSTANDING
Providing and laying 150mm thick Dry lean concrete (DLC) of compressive strength not less than 10 Mpa at 7 days for each consecutive group of 5 cubes or in dual strength of cube shall not be less than 7.5 Mpa at 7 days using table 600-1 Mpa for grading of aggregate, minimum cement content shall not be less than 150 kg/cum as per MORTH>IRC specification 49 including spreading and compacting by using mechanical vibratory roller of capacity 8 to 12 tonnes and testing as per IS complete all as specified and directed.
AREA DRAINAGE
Recharge pit/Soakage wells exc. In any type of soil, foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber brick work in CM, SFRC cover slab in M-25/ interconnecting pipes/ DWC complete Filling with brick bats, complete of size 3.0 m dia x 6.0 deep complete all as specified and directed.
EXTERNAL WATER SUPPLY
Supply, installation, testing and commissioning of end-suction & top-discharge, non-self-priming, single-stage, centrifugal volute type pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency, conforming to IS: 12615- 2018 at 2900 RPM speed star/delta starter panel, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply all complete as specified and directed by engineer-in-charge.
Horizontal End Suction Long Coupled type pump with insulation suitable for 1200 LPM water flow rate at 125 m head for domestic water supply. [1 W + 1 S]
Horizontal End Suction Long Coupled type pump with insulation suitable for 450 LPM water flow rate at 125 m head for flushing water supply. [1 W + 1 S]
Supply, installation, testing and commissioning of PN 1.0 rated CI 'Y' -type strainer for suction conforming to IS: 907- 1984 with SS filter screen and flange drilling standard end connection conforming to IS: 1538- 1993 and necessary accessories for suction side of fire pumps all complete as specified and directed.
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type WATER SUPPLY PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. Make: L & T, Schneider, Siemens, ABB
The Water Supply Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 250 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 160 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set
[ii] 32 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos. [for Area Lighting DB] [iii] 32 A, 230 V, 50 Hz, SPN MCB (C-curve) - 01 Nos. [for Pump room] [iv] LED phase indicators (Red, Yellow, Blue)- 03 Set [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 03 Nos. NOTES: [i] The Panel shall be completely Ethernet communication ready to communicate with Energy Management System. [ii] 04 Nos. of ON / OFF / TRIP status and operations counters as well as meters shall be wired to Ethernet gateway part of the Panel.
Supply, installation, testing and commissioning of water level indicator to indicate different levels of water filled in tank (up to 4 levels) in percentage having carbon sensor probes to sense the water level, LED indicators indicating different levels and suitable for 3 Ph, 415 ± 20% V system, and capable to support cabling length up to 1000 m complete all as specified and directed by engineer-in-charge.( All sensor shall be fitted in to the O/H water tank dully supported with strong& sturdy fixing arrangement)
M & L for ISI marked 1.1 kV grade 3 core 1.5 mm² copper conductor, XLPE insulated armoured cables, conforming to IS: 7098 (Part 1)- 1988 having stranded copper compact shaped conductor as per Cl. 2, IS: 8130- 1984, PVC inner sheath, single armouring of galvanized steel strip/wire and PVC Type ST- 2 outer sheath conforming to IS: 5831- 1984, including termination complete as specified and directed. (water level indicator to P/H)
"EXTERNAL ELECTRIFICATION"
UTILITY PANEL
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type UTILITY PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. Make: L & T, Schneider, Siemens, ABB
The Utility Panel shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 400 A, 415 V, 50 Hz AC, 4 Pole Auto Transfer Switch (ATS)- 01 Nos. [ii] 320 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos. [iii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iv] LED phase indicators (Red, Yellow, Blue)- 01 Set
[B] OUTGOING [i] 200 A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos. [for Building Utilities Panel] [ii] 160 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.- 01 Nos. [for water supply] [iii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 02 Nos.
NOTES: [i] The Panel shall be completely Ethernet communication ready to communicate with Energy Management System. [ii] 03 Nos. of ON / OFF / TRIP status and operations counters as well as meters shall be wired to Ethernet gateway part of the Panel.
MBD PANEL
Supply, installation, testing and commissioning of factory made, of MBD Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA painted sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels, T irons, flats wherever necessary for large meter boards. Cable gland plates shall be provided at top and bottom both and windows for meter reading, locking arrangement (pad-lock & seal) with wiring upto KWH meter & meter to MCB shall be done by using adequately rated flexible single core copper wire. The boards shall be treated with all anticorrosive process before painting as per standards with final approved shade of powder coated as approved, 2 nos. earthing terminals shall be provided for all panels. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Boards shall be fabricated in length, height, depth etc to match with site conditions. An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shall be used in fabrication of boards. Note: The following provisions shall be required to be made in the switchboard detailed below
The Switchboard shall have provision for entry of all PVCA cables/bus duct from the top/bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever required Positive isolation of all breakers. All fault level breaking capacity indicates shall be IC.S value at 415 volts (ICS = ICU = ICW = 100%). Space Heater/ light/air filter shall be provided as required Padlocking facility shall be provided on all outgoing feeders. Link and drops from MCCB shall be designed for full rated current of MCCB ratings at same current density as of Main Bus Bar 2 nos. GI earth strip throughout the MDB COMMON AREA PANEL Incoming (i) 630A, TPN MCCB with Micro processor based release having overload ,short circuit and Earth fault protection.01 Nos (Ics=100% Icu) and with following
Metering, Indication & Protection: (ii) Voltmeter with VSS 1 Nos. (iii) 1 Nos. 6 parameter energy analyser with CTs (iv) supply available indicating lamps with control MCBs.01 Sets (v) R-Y-B and ON/OFF indication lamps for incomer Bus Bar: 800A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings: (I) 160 A, TPN MCCB with thermal magnetic release having overload and short circuit protection 2 Nos. (Ics=100% Icu) (ii) 125 A, TPN MCCB with thermal magnetic release having overload and short circuit protection 2 Nos. (Ics=100% Icu) (iii) 100 A, TPN MCCB with thermal magnetic release having overload and short circuit protection. 01 Nos (Ics=100% Icu) (iv) 40 amp TPN MCB( Motor Duty) 6 nos. (v) 63 amp TPN MCB( Motor Duty) 1 nos. (vi) 32 amp TPN MCB( Motor Duty) 3 nos (vii) 63 amp DP MCB( Motor Duty) 2 nos. (viii)32 amp DP MCB( Motor Duty) 12 nos.
ROOF PANEL
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type ROOF PANEL of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge. Make: L & T, Schneider, Siemens, ABB
The Roof Panel shall comprise of the following: Incoming (i) 200A, TPN MCCB with Micro processor based release having overload ,short circuit and Earth fault protection. (Ics=100% Icu) and with following :-1 Nos. Bus bar link works to receive 3.5C - 50 Sq. mm Al Arm Cable incoming cable Metering, Indication & Protection: (i) Voltmeter with VSS 1 Nos. (ii) 1 Nos. 6 parameter energy analyser with CTs (iii) supply available indicating lamps with control MCBs for each supply 1 Sets (iv) R-Y-B and ON/OFF indication lamps for each incomer
Bus Bar: 200A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 25 kA. Neutral busbar shall be of 100% capacity. Outgoings: (i) 63A, TPN MCCB with thermal magnetic release having overload and short circuit protection and each with ELR and CBCT -5 Nos (Ics=100% Icu) (ii) 63A, TPN MCCB with thermal magnetic release having overload and short circuit protection. 1 Nos. (Ics=100% Icu) (iii) 40 amp TPN MCB( Motor Duty) :- 2 nos. (iv) 32 amp TPN MCB( Motor Duty) :- 1 nos
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable with copper conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size note- rate is inclusive of cable gland & cable lugs including necessary clamping / dressing with cable ties and termination complete all as specified and directed by engineer-in-charge.
4 core, 10 mm² (Lifts)
3 core, 6 mm² (UPS)
S&F LED streetlight having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficiency of > 100 lm/W, integral SMPS based constant current electronic LED driver with THD < 10%, surge voltage protection and other safety tests as per IS 15885 (Part- 2/Sec-13): 2012, IP 66 protection, polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm, including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket having 40 mm diameter light grade GI pipe, nuts, bolts, washers, GI clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by engineer-in-charge. Make: BAJAJ, Philips, Havells
Supply and fixing LED Landscape lighting 20W , made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP65 protection with high power LEDs as light source capacity including making necessary connection complete all as specified and directed. Make : Crompton Cat No:- LPTH-20-WW or equivalent make in Philips, C&S, Havells, BAJAJ
M & L for hot dipped galvanized iron octagonal pole of 6mtr height, minimum galvanizing of 70 micron, top -70mm dia , bottom 130 mm dia and 3 mm sheet thickness in single section with joints with box plate of minimum dimensions 220mm x220mmx 12mm , foundation bolts, single area GI bracket of 900-1000 mm for mounting the light fitting at an angle of 120°,Bakelite sheet with one 6A SP MCB and 16 mm stud type connector (4 Nos) inside the pole at door opening for cable connection, common templates minimum 1 for each 15 poles, all fixed and bolted on suitable PCC pedestal as per manufactures recommendation & specifications and all as directed. Make of poles shall be Bajaj/ Crompton/ Subham/Jindal.
M&L for ECO POLES Aesthetical designed decorative hot dipped galvanised mild steel step pole 4 Mtr with grey powder finish. Compactible for post top range,window- plasma cut & duly chamfered opening window of 300X110 mm for terminal connections & mounting accessories, window cover is fitted with allen screws to the pole, Decorative sleek casting ring to increase aesthetical appeal, all fixed and bolted on suitable PCC pedestal as per manufactures recommendation & specifications and all as directed. Make :- Havells Cat No 4MECOPOLE /Cromption /Bajaj/Wipro.
S & F weather- proof PVC looping boxes of size 250 mm x 200 mm x 100 mm, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos. of polymide gland with check nuts fixed on poles with flat aluminium clamps of size 20 mm x 3 mm, nuts, bolts, washers, etc. complete all as specified and as directed by engineer- in- charge. Make: Sintex, Hensel, HPL
Supply, installation, testing and commissioning of intelligent street light control (ATSC) suitable for 6 kW maximum load, wall/pole mounted, having built-in networking support, built-in astronomical timer, 32 A TP contactor, 40 A TPN MCB housed in 3.15 mm thick powder CRCA sheet housing all complete as specified and directed by engineer- in- charge. Make: Havells, HPL, Insu
COMPREHENSIVE MAINTENANCE OF LIFTS
Comprehensive maintenance and repair of fully automatic electrically operated passenger lift of any make and 16 Passenger capacity lift installed against Sch 'A' BOQ Item No. 21.01, herein before in building (G+33), (Total 04 Lifts) comprising of all devices and accessories through out 12 months on all days including holidays for period of 04 years after expiry of defects liability period as shown below and all as specified and directed by GE.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(c) 3rd year after expiry of defects liability period
(d) 4th year after expiry of defects liability period
Comprehensive maintenance and repair of fully automatic electrically operated lift of any make and 1020 Kgs capacity lift installed against Sch 'A' BOQ Item No. 21.05 herein before in building (G+33), (Total 01 Lift) comprising of all devices and accessories through out 12 months on all days including holidays for period of 04 years after expiry of defects liability period as shown below and all as specified and directed by GE.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(c) 3rd year after expiry of defects liability period
(d) 4th year after expiry of defects liability period
IRON TRIANGLE LIMITED
Rds Project ltd.
KALPANA STRUCT-CON PVT LTD
Som Projects Pvt. Ltd.
Varindera Constructions Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid