Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹14.8 L+₹31,904 (2.20%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹15.3 L+₹75,894 (5.23%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹15.5 L+₹99,214 (6.83%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹15.7 L+₹1.2 L (8.12%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Mar 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR REPLACEMENT TO INTERNAL WIRINGS INCLUDING MISCELLANEOUS REPAIRS TO CEILING FANS EXHAUST FANS GEYSERS BLDG LIGHTS SOLAR WATER HEATER AND ITS CONNECTED WORKS AT INSP ORG UNDER GE MH AND RH KHADKI
2024_MES_641868_1
8505/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹50,000
17 May 2024
10 Feb 2024
11 Mar 2024
10 Feb 2024
9 Mar 2024
25 Feb 2024
10 Feb 2024 - 2 Mar 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items shall be made as per condition laid down under schedule of credit seprately) and making good disturbed surfaces of walls, floors etc all as specified.
M&L for point wiring using approved colour coding as per IS (Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and sheathed FRLS cable1100 volts grade, ISI-694 (1990) marked with valid CML No in and including medium grade, PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories, mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep (with earth dolly) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-Charge for the following:- Make: Polycab /Finolex/ RR
(a) One fan/light /bell point controlled by one switch/bell push
(b) One switch socket outlet 5 Amps on independent board
(c) One socket outlet 5 Amps on the same board
All as per item No 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but sheathed copper conductor FRLS cable 1100Volts grade and 1.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board complete all as specified and directed by Engr-in-Charge
All as per item No 2 here-in-before but with 4 Sqmm PVC insulated multistranded copper conductor cable including 4 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board complete all as specified and directed by Engr-in-Charge
M&L for point wiring using approved colour coding as per IS ( Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathed FRLS cable1100 volts grade, ISI-694 (1990) marked with valid CML No in and including medium grade,PVC Conduit of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep ( with earth dolly ) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally , covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-Charge for the following:- Make : Polycab /Finolex/ RR
(a) One fan/light /bell point controlled by one switch/bell push
(b) One switch socket outlet 5 Amps on independent board
(c) One socket outlet 5 Amps on the same board
All as per Item No 5 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board through medium PVC conduit complete all as specified and directed by Engr-in-Charge
All as per Item No 5 here-in-before but with 4 Sqmm PVC insulated multistranded copper conductor cable including 4 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board through medium PVC conduit complete all as specified and directed by Engr-in-Charge
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size complete all as specified and directed by Engr-in-Charge. Note: Two single core cable, earth wire and PVC conduit shall be measured as one length.
Ditto item no 08 above but of 6 Sqmm cable
Supply and fix in repair ceiling rose surface bakelite with three terminals type in complete all as specified and directed.
Supply and fix in repairs switch piano type one way 6 Amps flush type ,240volt AC complete all as specified and directed.
Supply and fix in repairs socket outlet 2 in1,3 pin 5 Amps complete all as specified and directed.
Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3 pin, 5 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs switch piano type 16 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs socket outlet 2 in 1, 3/ 5 pin 16 Amps flush type complete all as specified and directed.
Supply and fix in repairs switch socket combination(SSC) 2 in 1, 3/5 pin, 16 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs Bell push, flush type, 6 Amp flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs switch piano type two way 6 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs Bell push, Modular type, 6 Amp flush type ,240volt AC complete all as specified and directed.
Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular switch 2 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular socket 6A /16A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular fan regulator,120 watt - 2 module complete all as specified and directed.
Supply & Fix in repair stepped type electronic fan regulator 120 watt, 240 volt flush type on the existing phenolic laminated sheet complete all as specified and directed.
Supply and fix in repair electric bell Ding Dong, AC 230 volts complete all as specified and directed.
Supply and fix in repair modular white cover plate with frame of following size complete all as specified and directed.
1 module
2 module
3 module
4 module
6 module
8 module
Supply and fix in repair RCCB 63 A, four pole, 30 mA complete all as specified and directed by Engr-in-charge. Make: Hager/L & T/Standard
Supply and fix in repair industrial wall mounted plug socket suitable for IP 44 degree of protection of 32Amps rating 3p+N +E all as specified and directed. Make: L&T cat part DBPPS563SD or other equivalent make complete all as specified and directed
S & F sheet metal enclosures for double door distribution board factory made duly painted of following capacity with 200 amps rated bus bar, suitable for fixing MCB /Isolators complete all as specified and directed. Make :L & T/legrand/Havells or equivalent.
12 way SPN , 240V
8 way SPN 240V
4 way TPN ,415V
8 way TPN ,415V
S & F MCCB 125 Amps, 4 pole, breaking capacity 16 KA, 415 V adjustable type complete all as specified and directed. Make: L &T /Legrand/Indoasian/standard.
Ditto item no 31 Above but of capacity 100 Amps.
Supply and fix miniature circuit breaker (MCB) of following current carrying capacity, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. Make L &T /Legrand/Havells
SP 5/6 to 32 AMP,240V, 10 KA 'B' curve
SP 40 AMP, 240V, 10 KA 'B' curve
SPN 32 Amps, 240V, 10 KA 'B' curve
SPN 40 Amps , 240V, 10 KA 'B' curve
TPN 63Amps, 240V, 10 KA 'B' curve
Labour only for attending MES complaints received through Mobile App / complaint slip with 01 High skilled electrician and 01 Helper for one shifts from 0830 Hrs to 1730 hrs on all working days at New Mandaly line Officer Qtr, Old Mandaly line Officer Qtr, Old Mandaly line MES Qtr, QMTI OR /JCO Md Accn, 204 PL ASC Supply, AGE E/M (W) Khadki office, BSO yard, AGE B/R (W) Khadki office, P-20 Burr road VIP bungalow, Range hills bungalow, Ashok Nagar & BDTC Md Accn, New MAP offr Md accn opposite to Stn workshop EME Khadki, Stn workshop EME Khadki, MES Qtr at Goal Market, Siprox Qtr, Aaya Qtrs and various E/M Installations complete all as specified and directed. Note: - (i) The complaints will be entered in complaint slip by JE E/M/MCM in-charge. (ii) The complaint slip should be returned to JE E/M on completion of the work with stores consumed. (iii) Any delay in attending the complaints for more than 03 days, a penalty of Rs 100/- per complaint will be adhered to the contractor. (iv) T & P, Minor spares like nuts, bolts, screws, washers required for attending the complaints shall be provided by the contractor. (v) Job card register and complaint register should provided by contractor to note down the MES complaints.
S & F in repair wall mounted extruded aluminium housing high quality indoor batten of following capacity having colour temperature 6500 K lumen 2000 -3000, PF> 0.9, THD less 15% diffused connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing and as per site requirement complete all as directed by Engr-in-charge. Make : Havells/wipro/Halonix or equivalent
LED tubelight fitting of 20 watt/22 watt , 4 Ft long
LED tubelight fitting of 10watt, 2 Ft long
S & F in repair recess mounting LED flat panel light fitting of following wattage and size with efficient LEDs lumen 2000 -3000, PF> 0.9, THD less 15% including taking down unserviceable fitting of any type and make complete all as specified and directed. Make : Havells/wipro/Halonix or equivalent
36 watt, 2 x 2 , 600mm x 600 mm size
18/20 watt, (1x1 )ft
Circular in size 18/20 watt not less then 6 '' dia
S & F in repair wall mounted high quality indoor wall bracket light cylinderical / oval shape aesthetically designed fitting with B22D lamp holder and 12 Watt bulb temp range 4000k to 6500 K as per site requirement connecting with three core flexible copper wire complete all as directed by Engr-in-charge. Make : Halonix cat No: HLWB-01-B22 or equivalent Havells/wipro
S & F in repair high effiicient suspended type 150 watt,230v, lumen 2000 -3000, PF> 0.9, THD less 10% LED bay light of die cast aluminium housing with lens embedded PC cover IP 66 with effficany not less then 120 lm/W, as per IS -10322 , high voltage cut off, open and short circuit protection including constant voltage and current LED driver complete all as directed by Engr-in-charge. Note: Making arrangement for T & P to fixing of bay light is incluidng quoted rate. Make : Havells/wipro/Halonix or equivalent.
S & F in repair high efficent LEDbuilding security light 30 watt , 230 V, lumen 2000 -3000, PF> 0.9, THD less 10%, made of pressure cast aluminuim housing with high power LEDs, lens and toughened glass IP 66 connecting with three core flexible copper wire from connecto to ceiling rose complete all as directed by Engr-in-charge. Make : Halonix, Bajaj, Havells or equivalent.
M & L in repair LED driver suitable for 36/40 watt LED panel light fitting (600 x 600 mm) complete all as specified and directed by Engr-in-Charge.
S & F in repair bracket for mounting building security light made out of 40 mm dia Light Grade GI pipe bend in angle with holding MS clamps two nos each bracket of size 25x3 mm including screw etc for fixing complete all as specidfied and directed by Engr-in-Charge
M & L in repair for earthing with galvansihed steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m for below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregate RCC cover, 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board complete all as specified & directed. Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge.
M & L for repairs & re-fixing on exiting or new location to storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (f) at different locations (a) Inspection, taking down, opening (dismantling) descaling, brushing, cleaning of storage tank (b) Examine water tightness of storage tank after cleaning. (c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) S & F in repair rubber / PVC gasket to ensure water tightness. (e) Checking of safety valve (f) Testing of geysers after repairs.
S & F in repairs thermal cutout ISI marked temp range 50-80/90 degree as required at site for geyser of capacity 25/35/50 Ltr of any make complete all as directed by Engr-in-charge
S & F in repairs of safety valve/high pressure valve ISI marked as per site requirement or complete all as directed by Engr-in-charge.
S & F in repairs heating element of following rating as required at site including rubber washers complete all as specified and directed by Engr-in-charge..
1/1.5 KW, 240 volt
02 KW , 240 volt
S & F in repairs PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection complete all as specified and directed by Engr-in-Charge
S & F in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection complete all as specified and directed by Engineer-in-charge.
S & F in repairs, non return valve 15 mm dia of brass, ISI marked complete all as specified and directed by Engineer-in-charge.
S & F in repair stop valve, cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore complete all as specified and directed by Engr-in-Charge
M & L for repairing and replacment of unserviceable copper container of capacity 25/50 Ltrs solar water heater of any type after completion of work testing the heater all as specified and directed by Engr-in-Charge
Copper container 50/100 ltr
Copper container capacity 25 Ltrs of water heater (gyeser)
M & L for rewinding of Ceiling Fan, Exhaust Fan and Air circulator of any type/make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: Bearing ,fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
Ceiling fan of 1200/1400 mm sweep
Exhaust Fan of sweep 275-300 mm
Exhaust Fan of sweep 350-450 mm
Air circulator of sweep 350-450 mm
Supply only ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC
Supply only ball bearing suitable for 275-450 mm exhaust fan complete all as specified and directed Make : SKF/NBC or equivalent
Supply only fan capacitor of following capacity complete all as specified and directed
Supply only capacitor 2.5 mfd
Supply only capacitor 4 mfd
Supply only, rubber yoke, MS clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge.
Supply only gunmetal bush suitable size for ceiling fan 1200 /1400 mm sweep complete all as specifed and directed by Engr-in-Charge.
Supply only fan down rod of following length with white enamel paint with both side hole for hanging fan of sweep 1200/1400mm complete all as specified and directed
1 ft long
2 ft long
Supply only stator for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting rotor size complete all as specified and directed
Supply only rotor for ceiling fan of 1200/1400 mm sweep with silicon coating, anti rust coating, size and slot as per sample, feasible to fix in exisiting stator size complete all as specified and directed
Supply only fan canopy set off white /white coloured as per colour of ceiling fan of sweep1200/1400mm complete all as specified and directed.
Taking down old/new electric meter three phase/single phase, taking it to testing lab as approved by State electricity board or NABL approved lab calibarating it and reparing it if rejected in testing parameters of the testing authorities. Refixing the meter back to the site with proper nut bolts, washers/fastners and suitable size of connecting pvc copper wire as per reqd length complete all as specified and directed. Note:- (i) Test certificate/calibration report of the electric meters to be provided by the contractor (ii) The meter is to be fixed on wooden board of thickness not less than 8 mm size as per the site requirement. (iii) The rates are all inclusive of dismantling, transporting, repairing , calibrating and refixing back on wooden board of thickness not less than 8 mm to its original place. (iv) Contractor has to install new meter issued from the dept before dismantling the old meter. (v) The meters will not be given in complete lot , meters will be given as and when required basis or as directed by the Engr-in-charge. (vi) All minor spares such as CT's power convertor, circuit board,(PCB), resistors, terminal covers etc as required are included in quoted rates.
Supply and fix in repair hylum sheet 3 mm thick for Junction boxes, circuit boxes for various size and refixing the existing switches, sockets, regulators cut in to requied sizes including fixing with new cadmium plated screws and cup washers complete all as specified and as directed.
M & L in repair for PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
100 x 100 mm and 50 mm deep
200 x 150 x 50 mm deep
250 x 200 x 50 mm deep
150 x 150x 50 mm deep
Decarbonizing of indoor MCB / meter box any type removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter, replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of broken MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB & MCBs, powder coating painting with suitable 'U' type gasket to make it dust and vermin proof, providing fancy locks incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed by Engr -in- charge. Note : (i) MCCBs,indicator lamps,Ammeter, Volt meter, will be measured & paid separately as supply only. (ii) necessary MS sheet and welding incuding sealing the meter with sealing Lead/PVC seal with MES Emblum empossing on it all are inclusive coated rate. (iii) Required size of neutral bus bars including coated rate. (iv) Required size of copper cable for connecting MCBs and meters are including quoted rate.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc., with its original specification complete all as specified and directed.
M&L for point wiring flame proof and including in stove enamelled ERW steel conduit 20 mm dia medium grade on surface with ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRHR) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRHR) copper conductor cable as earth wire with all flame proof fittings such as elbow, bends, junction boxes, ceiling rose saddles , flexible metal conduits etc. incl suitable size of sheet metal box 1.6mm thick (ISI Mark), screws and rawal plug etc. and connected to light/fan and common earth dolly with necessary copper thimbels complete all as specified and directed by the Engr-in-charge for the following :-
One light/fan point controlled by one, one way flame proof switch .
-Ditto- all as per item No 64 here-in-before but for socket out let, 15/16 Amps. independent with 2.5 Sqmm size cable and 2.5 Sqmm for continuity earth wire connected to common earth dolly complete all as specified and directed by Engr-in-Charge.
S&F LED tube light fitting 1x16W flameproof type FLP-WP made of aluminium alloy LM6, complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Note : The rates are inclusive of LED Tube rod of 16 Watt.
S&F in repair FLP-WP flood light fittings of capacity 120 watts made of aluminium alloy LM6, complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-charge. Make-Shyaam, Cat No. - SSPL/1251 or Sudhir or equivalent.
M & L for rewinding of flame proof ceiling fan of 1200/1400 mm sweep of any make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: Bearing ,fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
All as per item No 68 above but Exhaust Fan of sweep 300-450 mm
S&F FLP - WP switch socket and plug combined in LM6 aluminium alloy 16 A 2P + Earth complete all as specified and as per Make-Sudhir or equivalent.
S&F FLP - WP switch flame proof rotary ON-OFF type with termination box in LM6 aluminium alloy, 10/16A, single pole 250V all as per Make-Shyaam, Cat No. - SSPL/2C/1010. or Sudhir or equivalent.
S&F flame proof, weather proof 12 way SPN MCB DB 240 V. 50 Hz in LM 6 construction, consisting of 01 No. incoming MCB SPN- 63 Amps(01 Nos), MCB SP – 6 to 32 Amps (10 Nos), 10KA Breaking capacity as outgoing with clip on type terminals with suitable cable entries certified by CMRI Dhanbad complete all as directed by Engr-in-Charge. Make : Shyaam Cat Part NO-SSPL/MCDB/186 or Sudhir or equivalent.
S&F in repair of flame proof, weather proof 8 way SPN MCB DB 240 volts in LM 6 construction consisting of 01 nos of incomer MCB SPN -40/32 amps (01) Nos MCB SP -06 -32 Amps 06 nos 10 KA breaking capacity as outgoing all as specified. Make : Shyaam Cat Part No-SSPL/MCDB/186 or Sudhir or equivalent.
S&F submain wiring alongwith earth wire with FRHR PVC insulated copper conductor, multistranded, on surface of size 2 x 6 Sqmm & 1 x 6 Sqmm earth wire in ERW steel conduit complete all as directed by Engr-in-Charge. Note: Two run of FRHR PVC insulated copper cable, earth wire and Steel conduit shall be measured as one length.
PURVA ELECTRICALS AND ENGINEERS
M/S kirpan Enterprises
SKS Electricals
ONKAR ELECTRIC AND GENERAL STORE
ANUSHKA BUILDERS
SHREE VAIBHAV ELECTRICALS
PAMS ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .