Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 CrAccepted-AOC | ₹10.1 Cr Quoted ₹10.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹11.8 CrRejected-Finance | ₹11.8 Cr | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹11.8 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹11.8 Cr | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹11.9 CrRejected-Finance | ₹11.9 Cr | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹12.3 CrRejected-Finance | ₹12.3 Cr | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹12.2 Cr
EMD Value
₹9.4 L
Closing Date
16 May 2022, 6:00 pmClosed
HQ CELZ LUCKNOW
Headquarter Chief Engineer Lucknow Zone, 17 Carriappa Marg Post Dilkusha, Lucknow Cantt
UPGRADATION OF CENTRAL ENGINEERING SERVICES AT LUCKNOW CANTT
2022_MES_518543_1
CELZ/LKO/T-03 OF 2022-23
Open Tender
Electrical and Maintenance Works
270 days
HQ CELZ LUCKNOW
As per NIT
7 documents required · 7 mandatory
₹3,000
GE(E/M) Lucknow
₹9.4 L
Yes
HQ CELZ LUCKNOW
9 Jun 2022
18 Apr 2022
18 May 2022
18 Apr 2022
16 May 2022
9 May 2022
20 Apr 2022 - 29 Apr 2022
30 Apr 2022
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying pipes/cable etc. n exc 10 sq m on plan and not exc 1.5 m in depth complete all as specified and directed.
Returning & filling in of excavated any type soil including spreading leveling watering and well ramming in layers n exc 25 cm thick etc complete all as specified and directed.
Removal of excavated soil/materials to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Removal of excavated soil/materials to a distance exceeding 250 m but not exceeding 500 m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for Sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured and paid.
M&L for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as copping of pole all as specified and directed
M&L for cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as copping of pole all as specified and directed .
M&L reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L reinforced cement concrete (nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batt complete all as specified and directed.
Formwork to square rectangular or polygonal rough surface of concrete of sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate 100mm thick as sub base of floors complete all as specified and directed.
M&L for machine pressed precast concrete inter locking paver block of any shape and size confirming to IS 15658-2006 of thickness 80mm, M-40 grade set and jointed with neat grey cement and pigment including 40 mm thich sand cushion etc complete all as specified and directed.
M&L for Rendering 10 mm thick in cement mortar (1:6) on brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar (1:4) on fair faces of brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
Material and laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed.
Supply & laying un- reinforced precast concrete cable cover class HVP type 1 with peak size 300 mm x180mmx40mm in trenches for protection to under ground cable complete all as specified and directed.
M&L for MS Work as in hand rails, half round or other stock section, straight portion, girders of any section.complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L Mild steel TMT bars 5mm dia upto and including 10mm dia, cut to length, spacers and binders and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Framed work such as grills, gratings, etc with ends of bar, shouldered and /or riveted or forged into spikes framed guard bars barred iron doors, ladders, frame work of water tanks and similar work hung as gates including pintle hinges, stops, hand made sliding bolts confirming to FE 290 Gde Fe 165foundation, filling and mass concrete etc including necessary formwork complete all as specified and directed.
Taking up old/ UNSV PVC pipe of size 100mm dia any class (including all fittings) including disconnecting pipes and fitting complete all as specified and directed.
Taking up old/UNSV cast iron pressure pipe of size 150mm dia any class (including all fittings) including disconnecting pipes and fitting complete all as specified and directed.
Taking up old/UNSV cast iron pressure pipe of size 200mm dia any class (including all fittings) including disconnecting pipes and fitting complete all as specified and directed.
Material & labour for laying & testing Ductile Iron pipe 100 mm bore class K-7 both end flanged as per relevant IS in any length suitable for rubber flange joint laid in trenches complete all as specified and directed.
Material & labour for laying & testing Ductile Iron pipe 150 mm bore class K-9 both end flanged as per relevant IS in any length suitable for rubber flange joint laid in trenches complete all as specified and directed.
Material & labour for laying & testing Ductile Iron pipe 200 mm bore class K-9 both end flanged as per relevant IS in any length suitable for rubber flange joint laid in trenches complete all as specified and directed.
Supply, laying, jointing and testing of sluice valve of size 200 mm bore 'ISI marked' both ends flanged and drilled cast iron body class PN-1.6 conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts etc with all fittings,complete all as specified and directed.
Supply, laying, jointing and testing of sluice valve of size 150 mm bore 'ISI marked' both ends flanged and drilled cast iron body class PN-1.6 conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts etc with all fittings,complete all as specified and directed.
Cutting of road (in hard/ dense soil ) for laying pipe line or repair to pipes / lead joints etc .of any size of pipe upto 01 mtr. depth and 0.6 mtr wide and getting out incluiding forming bottom surface to required level and making good the road as per existing all as specified and directed.
Drilling/boaring (horizontally) including also for laying pipe line upto 150 mm /200 mm bore by penumatic tool or horizontal boaring/drilling machine under the existing road (max. 10 mtr. In width) suitable for passing GI/CI/DI tubing complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 1200 mm X 1200 mm X 1200 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, duly welded with heavy duty hinges 03 Nos for open/closing purpose on one side of angle iron, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 1050 mm X 1050 mm X 1050 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, duly welded with heavy duty hinges 03 Nos for open/closing purpose on one side of angle iron, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, duly welded with heavy duty hinges 03 Nos for open/closing purpose on one side of angle iron, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
M&L for cutting of CI/DI pipes of 150mm bore in position for insertion of Tees, branches etc. Incl dewatering due to residual water in pipes complete all as specified and directed. Note : DI fittings joint and jointing materials incl earth work will be measured and paid separately under relevant items.
M & L for flange pipe joints with 3mm thick rubber gasket (packing ring) incl provision of suitable size bolts, nuts and washers etc. 100mm bore pipe complete all as specified and directed.
M & L for flange pipe joints with 3mm thick rubber gasket (packing ring) incl provision of suitable size bolts, nuts and washers etc. 150mm bore pipe complete all as specified and directed.
M & L for flange pipe joints with 3mm thick rubber gasket (packing ring) incl provision of suitable size bolts, nuts and washers etc. 200mm bore pipe complete all as specified and directed.
S & F cast iron specials ISI marked for pressure water mains upto 150mm bore spigot and socket Tee pieces, single or double brunch connection or collar etc. complete all as specified and directed. Note : Excavation and earth work shall be measured and paid for separately.
S & F cast iron specials ISI marked for pressure water mains upto 200mm bore spigot and socket Tee pieces, single or double brunch connection or collar etc. complete all as specified and directed. Note : Excavation and earth work shall be measured and paid for separately.
M&L for drilling vertical bore of 250mm dia at site through any kind of soil including hard stone/boulder by direct rotary method and all works pertaining to pilot boring upto 300mtr depth below ground level complete all as specified and directed. (PREM NAGAR, MORTUARY, HUDSON LINE, BASE HOSHPITAL, NEW POLO, 56 CHAURAHA & OUTRAM LINE).
M&L for drilling vertical bore of 250mm dia at site through any kind of soil including hard stone/boulder by direct rotary method and all works pertaining to pilot boring exceeding 300 mtr depth and upto 500mtr depth below ground level complete all as specified and directed. (PREM NAGAR, MORTUARY, HUDSON LINE, BASE HOSHPITAL, NEW POLO, 56 CHAURAHA & OUTRAM LINE).
M&L for Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 675 mm, from 0 to 160 Mtr deep below ground level of reaming 675 mm size including all works pertain to boring complete all as specified and directed.
M&L for Reaming (Expanding) vertical bore of pilot bore of 200 mm dia to 525 mm, from 160 to 500 Mtr deep below ground level of reaming 525 mm size including all works pertain to boring complete all as specified and directed.
M&L for Mild steel sheet casing plain ERW casing pipe 300 mm bore, 8 mm thickness, conforming to IS: 4270 -2001, ISI marked, lowering and fixing in position upto required depth in all strata cut into different length including cutting, welding pipe jointed and welded coupler rings through out circumference of the pipe and coupler rings both side as in bore wells complete all as specified and directed. NOTE :- (i) Length of each pipe shall not be less than 2.4 metre except where pipe length required is less than 2.4 meters. (ii) Welding shall be done through out the circumference of the pipe and coupler rings both side. Make: JINDAL/TATA/ SAIL
S&F in position plain ERW MS pipe 150 mm dia (internal), 7 mm thickness, conforming to IS: 4270-2001, ISI marked complete and lowering and fixing in position after reducing socket 300 mm × 150 mm bore complete all as specified and directed. Make:-JINDAL/TATA/SAIL
S&F in position ERW MS slotted pipe 150 mm dia (internal), 7 mm thickness, conforming to IS: 4270-2001, ISI marked having slot of size 0,75 mm wide, 7mm thickness including cutting, welding complete all as specified and directed Make:-JINDAL/TATA/SAIL
M&L Pea gravel of 2 mm to 4 mm size of approved quality as ordered to pack around the casing/slotted pipes in bore well in angular space between well assembly and bore hole wall should be over minimum 15-18 cm and thoroughly washed before surrounding in the well and treated, with suitable amount of sodium hexa-metaphosphate for 24 hrs before developing by compressed air complete all as specified and directed.
Electric logging in pilot bore for precise delination of granular zones as also the quality of ground water including report interpretation complete all as specified and directed. Note : Electric logging shall be carried out by any approved Govt Agency.
M&L for MS bail plug of 150 mm dia size 10 mm thick of 1m long with MS Rod 25mm dia size welded to it at bottom bail hook complete all as specified and directed.
S&F two number of MS flat iron 150mm × 16mm thick size clamp for holding with 300mm bore housing pipe including casting of PCC block of size 1200mm × 1200mm × 1000mm in PCC 1:2:4 type B1 using 20mm graded stone aggregate including 150mm bore MS pipe two Nos each 1.5 meter long with cap plug and cap top for feeding pea gravel for bore well complete all as specified and directed.
S & F well cap of 300mm dia and 8mm thick size on top of the pipes with locking arrangement complete all as specified and directed. Note :Contractor shall ensure to proper lock of well cap to avoid any casualty.
Supply only strata sample box with glass cover 3 mm thick having internal dimension 1000mm × 600mm × 100mm made out of 20mm thick shisham wood with hinges hasp and staple including polishing complete with samples at various strata met in boring including strata chart in duplicate complete all as specified and directed.
M&L for MS black column pipe, 3 mtr long heavy duty, 100mm bore, wall thickness 6.5mm, both end flanged with heavy duty MS flanged not less than 16mm screwed and welded inside and outside. Make : JINDAL/ TATA/ SAIL/ PRAKASH/ SURYA
M&L for Yield testing for the bore well with the help of ORIFICE method by continuously pumping for 16 hours to determine safe pumping yield complete all as specified and directed.
M & L for chemical and bacteriological testing of sample from approved laboratory to ensure potability of water complete all as specified and directed. (PREM NAGAR, MORTUARY, HUDSON LINE, BASE HOSHPITAL, NEW POLO, 56 CHAURAHA & OUTRAM LINE).
M&L for Developing tubewell by compressed air with minimum pressure of 10Kg/Sq cm to 30 Kg / Sqcm and minimum 450 CFM all as specified in IS 11189-1985, para 4.3 and directed at site. Note :- (i). Compressor, pump, pipe and other allied items shall be arranged by the contractor and nothing extra shall be admissible on this account. (ii). Draining shall be got approved by the GE.
M & L developing tube well by over pumping for tube well complete after development by compressor and water shall be used only after receipt of satisfactory test result (PREM NAGAR, MORTUARY, HUDSON LINE, BASE HOSHPITAL, NEW POLO, 56 CHAURAHA & OUTRAM LINE).
S & F submersible cable PVC insulated and PVC sheathed conductor 16 Sqmm, 3 core, 1100 volts grade flat copper cable conforming to IS-694 1977 complete with necessary electric connection complete all as specified and directed
Supply, Installation, commissioning and testing Submersible pump set comprising of bronze impellers directly coupled with motor cast iron body electric driven 415V, TP suitable for 300 mm dia borewell multi-stages, discharge of 800 LPM at 105 metre head and complete with suitable end connecting tail piece, NRV complete all as specified and directed.
Supply, laying and testing of LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, installation & testing of automatic digital micro processor based servo controled Voltage Stabilizer 50 KVA, oil cooled with indoor enclosure with bottom cable entry with MCCB at input voltage 300 to 480 volt & output voltage 415 volt with accuracy +2.5% for tripping at various fault condition & speed of correction 8 volts per second. First filling of oil incl & suitable for unbalanced input voltage & unbalanced load including over volt, under volt, over load, short circuit & single phasing preventor with LCD display with back light for displaying input/output voltages & load current alongwith fault/ trip messages complete all as specified & directed
S & F high pressure single head gear motorised adjustable liquid dosing pump complete 230 volts, 50 Hz gear motor (incl all fittings & PVC tank 200 ltrs capacity), commissioning & testing as approved by GE with the following accessories :- (i) Adjustable high pressure single Head Gear 0 to 70m head (ii) Rated 230V, 50 Hz, (iii) Power of pump 1/30 HP minimum (iv) RPM not less than 44 minumum (v) Output 2 US GPD to 30 US GPD (vi) Pump tube connection nut injection check valve, clay weight, ferrules etc. Make : Daclibac or equivalent as approved by GE .
S&F of CI Reflex valve (NRV) both end flanged of size 150 mm (ISI marked) with out by pass arrangement including jointing material, commissioning and testing complete all as specified and directed.
Supply, installation, testing & commissioning electrically connected feeder pillar outdoor type single door compartmenttized with locking arrangements canopy at top weather proof vermin/dust proof of suitable size cubical type factory made of CRCA MS Sheet 3.15mm thick machine pressed of size 60x60x40cm & angle iron frame 40x40x6mm for legs & incl grouted in PCC 1:2:4 type B1 (using 20mm graded stone aggregate) suitable 440 volts, AC, 3 phase, 4 wire busbar 4 pole made out of suitable size copper strip capacity 200 Amps fully mounted on procelain insulator enclosed chamber with openable shutter both sides complete all as specified & directed.
Supplying, laying or fixing. Jointing & testing solid PVC insulated, 10 pairs, individual shielded for interference rejection, armoured PVC sheathed 1100 volts grade 0.5 sqmm instrumental cable ISI-5608 marked laid in trenches/ under floor incl taking out unserviceable cable complete all as specified & directed. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block, clamps, nuts, bolts, washers & pipe shall be measured & paid separately under appropriate items.
S & F water level indicator of OHT 25 mtr head & approx 60 to 90 mtrs apart from the tubewell complete kit in all manners as approved by E-in-C's Branch IE Co. or equivalent of Servel/ Surya Electronics & Control complete all as specified & directed
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
S&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all speciified and directed.
S&F Junction Box made out of MS sheet of size 300 x 300 x 150mm complete with 100 amps, three phase and one neutral rated aluminium bus bar with MS clamp of size 35 x 6mm, MCB SP 6 amp inside the box and fixed on pole with MS clamps, nuts, bolts and washers complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty stranded cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2.5 sq. mm nominal cross section in service connections complete all as specified and directed.
M&L for Earthing (new location or in replacement) complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not 1ess than 2. 25 mtr below normal GL with the top edge of the plate not less than 1.5 mtr below the ground level connected by GI strip of size 32 x 6 mm thick soldered and revetted to earth plate. Complete with watering pipe 20 mm bore GI pipe (light grade) and chamber PCC (1:4:8) type D2 using 40 mm grade stone aggregate, coping shall be PCC (1:3:6) type C-1 using 20 mm graded stone aggregate and RCC (1:2:4) type B1 using 20 mm graded stone aggregate pit cover 50 mm thick reinforced with 8mm tor MS bar at 80 mm c/c both way including excavation and earth work and removal of surplus soil complete all as shown in electrical plate No . 3 of SSR part and as specified including earth plate packed all sides with charcoal dust, common salt and testing complete including GI sheet funnel, wire mesh etc complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, laying, jointing & connecting XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade 2 core, 10 Sqmm with stranded aluminium conductor compelte all as specified & directed. Note : Excavation & earth work will be measured & paid separately under respective items
M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable compelte all as specified & directed.
Material and labour for PCC 1:2:4 type B-2 (using 40 mm graded stone aggregates) for filling of cutting of roads/path/hardstanding etc compelte all as specified & directed.
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed.
Supplying and fixing mild steel water tubing 40 mm bore with screwed & socket joints, light grade, galvanized (including short lengths) with and including all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc as per IS-1239 part-II complete all as specified and directed.
Supplying and fixing mild steel water tubing 50 mm bore with screwed & socket joints, light grade, galvanized (including short lengths) with and including all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc as per IS-1239 part-II complete all as specified and directed.
Supplying and fixing mild steel water tubing 80 mm bore with screwed & socket joints, light grade, galvanized (including short lengths) with and including all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc as per IS-1239 part-II complete all as specified and directed.
Supplying and fixing mild steel water tubing 100 mm bore with screwed & socket joints, light grade, galvanized (including short lengths) with and including all necessary fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc as per IS-1239 part-II complete all as specified and directed.
Supplying and laying or fixing, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip armoured, ISI-7098 Marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade , cross sectional area 10 Sqmm , 4 core complete all as specified laid in trenches/ laid under floor or fixed naked with walls/ on poles/ in ducts /in GI pipes etc. with and including MS clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under resective items of schedule
Ditto all as per srl no. 84 here-in-before but cross sectional area 16 sqmm, 4 core complete all as specified and directed.
Ditto all as per srl no. 84 here-in-before but cross sectional area 25 sqmm, 4 core complete all as specified and directed.
Ditto all as per srl no. 84 here-in-before but cross sectional area 35 sqmm, 3.5 core complete all as specified and directed.
Ditto all as per srl no. 84 here-in-before but cross sectional area 95 sqmm, 3.5 core complete all as specified and directed.
Ditto all as per srl no. 84 here-in-before but cross sectional area 120 sqmm, 3.5 core complete all as specified and directed.
Ditto all as per srl no. 84 here-in-before but cross sectional area 185 sqmm, 3.5 core complete all as specified and directed.
Ditto all as per srl no. 84 here-in-before but cross sectional area 240 sqmm, 3.5 core complete all as specified and directed.
Ditto all as per srl no. 84 here-in-before but cross sectional area 500 sqmm, 1 core complete all as specified and directed.
Ditto all as per srl no. 84 here-in-before but cross sectional area 630 sqmm, 1 core complete all as specified and directed.
M&L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated multistranded copper conductor cable 2x6 sqmm & 1x6 sqmm as earth wire with and including surface PVC casing caping of size not less than 20 mm complete all as specified and directed.
Supplying and fixing Verticle TPN DB IP-54 protection 6 way double door with MCCB FP 125 Amps , 25 KA 415 Volts AC , 50 Hz , and sheet metal enclosure including MCB SP 32 Amps -18 Nos complete with existing cabling network including making good disturbed surfaces complete all as specified and directed .
S&F wheather proof pole mounting junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10 Amp -1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed.
Supply drawing, connecting and testing 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs complete all as specified and directed.
Earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing.
Supplying and laying or fixing, jointing and testing of XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 120 sqmm, 3 core complete all as specified and directed.
Supply and fix cable end jointing kit for 11 KV grade cable for indoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 sqmm. Complete all as specified and directed.
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 sqmm. Complete all as specified and directed.
Supply & install ,testing and commissioning of transformer as per IS : 1180 part - I of 2014 amendment no 1,2,3,&4 level -II step down, copper wound 11KV/433 Volts (at no load) AC 3 phase 50 Hz 315 KVA capacity, core type, oil immersed naturally air cooled, oil natural air natural (ON/AN) , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV) and having taping at +5% to +10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changergear. The maximum temperature rise should not exceed 50 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade crgo with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076and as per IS-1180 part - I of 2014 marked and shall comprise of the following :-
(a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer , with cable glands suitable for reception/taking out 3 core 120 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete.
(b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out single core 500 sqmm/630 Sqmm , LT 1100 volts grade, PVC/XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete.
(c) conservator with filter type drain valve and oil level guage.
(d) De-hydrating breather with first fill of dehydrating agent (Silica Gel).
(e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, at bottom of the tank Lifting ligs,oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers.
(f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(g) Two earthing terminals on tank cover to facilitate fixing of 32x6mm galvanised iron earth strip for earthing of body.
(h) Rating plate and terminal marking plate.
(j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
(k) First fill of new and unused transformer oil, IS-335 of 1986 marked, filtered and tested upto 50 KV dielectric strength at 2.5 mm air gap between testing electrodes, specific resistance at 27 Degree celsius Ohm-om 500 x 10 the power12, water content 50 PPM, Dielectric dissipation factor (tan Deta at 90 degree celsius) 0.005, Neutralisation value mg of KOH/gm of oil 0.03, Inter facial tension N/M at 27 Degree celsius - 0.04, flash point 140 Degree celsius and sluge 0.1 % by weight.
(l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer.
(m) Tranformer losses shall not exceed the loses mentioned in IS: 1180 Part-I of 2014 amendment No 1,2,3 & 4 with energy Effeciency level - II.
(n) Oil temperator indicator.
Ditto all as per srl no. 104 here-in-before but 400 KVA complete all as specified and directed.
Ditto all as per srl no. 104 here-in-before but 500 KVA complete all as specified and directed.
Supplying , installation, testing and commissioning of 12 KV, 630 Amps having short circuit capacity 21kA/3-sec, Outdoor (IP54), RMU (Ring main unit) 3-way comprising of 01 Nos motorized operated Load Break Switch and 02 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank with min. thickness 3+0.5 mm, IP 67 Degree of Protection , internal-arc classified 21kA/1sec, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit alongwith Bus-connected, fixed-type Auxiliary transformer shall include the following along with all necessary accessories and fittings as required at site.
(A) 01 Nos. Incoming Load Break Switch module each consisting of following accessories :- (i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 12V, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21kA/3-sec, Making Capacity - 50kAp -01 No (iii) Auxiliary contacts - 1NO + 1NC-01 No (iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 (vi) Right angle boots (push on type)-Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No
(B) 02 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 12kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp-01 No (iii) Aux. contacts - 1NO+1NC-01 No (iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No (v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 120 Sqmm , 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 (vi) Right angle boots (push on type)-Each set of 3 (vii) 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol-01 No (viii) Associated ring-core cast-resin insulated CTs 50/1 Amp , 2.5 VA, 10P10 for protection - Each Set of 3 (ix) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (x) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (xi) Push button for breaker trip (xii) Shunt trip coil 24V DC - 01 (xiii) ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. (xiv) Emergency Trip Push Button - 01.
(C) 01 No. Bus-connected, fixed-type Auxiliary transformer accomodated in separate compartment of matching height and depth, positioned along-side or top of RMU to provide required aux. supply and metering consisting of following accessories :- (i) 1-Ph (11kV/rt3):230VAC, 500VA Auxiliary transformer-01 No (ii) 2x12 Volt DC battery-01 Set (iii) Battery charger-01 No (iv) HRC fuse-links for primary side isolation and AC/DC MCBs for secondary isolation-01 Set (v) Voltmeter & RYB LED Indications to confirm AC/DC supply availability-01 Set (vi) Anti-condensation space-heater-01 No (vii) CFL lamp for illumination and 3-pin socket with switch -01 No
(D) Additional equipment deliverd separately or mounted seperately :- (i) Operationg Handle for Manual Isolator/Disconnector/Earthing Operation-02 Nos (ii) Standard Manometer -01 No (iii) Operation and Maintenance Manual -01 No (iv) Installation & Commissioning Manual -01 No (v) Cable clamping provision (standard) -01No
Supply and fixing in replacement 40 W LED street light fitting with mandatory driver set having pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embaded PC cover , street light should have IP 65 protection, impact resistance of IK 07 , Lumen efficiency of LED not less than 100 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,street light should have built in potted electronic LED driver with APFC, lower THD, open circuit protection , over voltage protection , surge voltage protection , and provided with company LOGO ingraved on housing of the street light complete including taking down of old UNSV fittings complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Ditto all as per srl no. 109 here-in-before but 60 Watt, IP 66 protection and Lumen efficiency of LED not less than 110 lumen per watt system efficency complete all as specified and directed.
Ditto all as per srl no. 109 here-in-before but 70 Watt, IP 66 protection and Lumen efficiency of LED not less than 110 lumen per watt system efficency complete all as specified and directed.
Supply and fixing in replacement of 70 Watt LED flood fitting having epoxy powder coated die cast aluminium housing ADC12 in grey finish with elegantly designed heat sink for efficient thermal management , sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout , PC lens with narrow /wide beam distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 100 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,flood light should have built in potted electronic LED driver with APFC, lower THD, open circuit protection , over voltage protection , surge voltage protection , and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fixing in replacement of 100 Watt LED flood fitting having epoxy powder coated die cast aluminium housing ADC12 in grey finish with elegantly designed heat sink for efficient thermal management , sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout , PC lens with narrow /wide beam distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 100 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,flood light should have built in potted electronic LED driver with APFC, lower THD, open circuit protection , over voltage protection , surge voltage protection , and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings complete all as specified and directed. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
M&L Brick work with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete as specified and directed .
M & L for PCC 1:3:6 type C-2 (using 40 mm gradded aggregate) for foundation, filling and mass concrete etc complete all as specified and directed .
M & L for cement concrete 1:2:4, type B-2, 100 mm thick (using 40 mm gradded aggregate) for floors and paving etc complete all as specified and directed.
S&F MS work of angles for post and struts of fencing around transformers and RMU etc drilling holes, flat iron ,fillet for securing wire mess by welding to angle iron frame and framed work as in gate of angle and wire mess . Door to be fixed by 03 Nos 100mm long hinges and one sliding door bolt of 300mm long for locking arrangement and MS channel for plinth of transformer complete all as specifed and directed.
Supplying and fixing Chain link MS galvanisd fencing, any size or type complete all as specified and as approved by Engr -in-charge.
Dismantling of steel poles any type any size complete all as specified and as directed by Engineer-in-Charge.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of any size and setting a side complete all as specified and as directed by Engineer-in-Charge.
Dismantling taking down old cross arms, clamps, brackets etc of any section from pole including nuts, bolts, washers complete all as specified and as directed by Engineer-in-Charge.
Dismantling of insulators any type and any size complete all as specified and as directed by Engineer-in-Charge.
Dismantling of GI wire any type and any size complete all as specified and as directed by Engineer-in-Charge.
Dismantling of stay assembly any type and any size complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement GI brackets made of 40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc complete all as specified & directed by Engr-in-Charge.
Disconnecting the LT cable from Panel / Pole, preparing the end for jointing including all earth work and Supply and fixing Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5/4 core 10 to 16 Sqmm complete all as specified and directed.
Ditto all as per srl no. 126 here-in-before but size 25 to 50 sqmm complete all as specified and directed.
Ditto all as per srl no. 126 here-in-before but size 70 to 120 sqmm complete all as specified and directed.
Ditto all as per srl no. 126 here-in-before but size 150 to 185 sqmm complete all as specified and directed.
Ditto all as per srl no. 126 here-in-before but size 240 to 300 sqmm complete all as specified and directed.
Disconnecting the LT cable from Panel / Pole, preparing the end for jointing including all earth work and Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5/4 core 10 to 16 sq mm complete all as specified and directed.
Ditto all as per srl no. 131 here-in-before but size 25 to 50 sqmm complete all as specified and directed.
Ditto all as per srl no. 131 here-in-before but size 70 to 120 sqmm complete all as specified and directed.
Ditto all as per srl no. 131 here-in-before but size 150 to 185 sqmm complete all as specified and directed.
Ditto all as per srl no. 131 here-in-before but size 240 to 300 sqmm complete all as specified and directed.
Taking down old unserviceable aluminium sub main wiring any size complete with PVC conduit/ casing capping and removing materials from site and making good disturbed surfaces of walls, etc complete as specified and directed.
M&L for out door type busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 50x50x6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 250 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three. (d) Platform of Panel. Platform for the busbar panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
Ditto all as per srl no. 137 here-in-before but comprising of the following:- (a) FP, Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 160 Amps 25 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 sqmm. complete all as specified and directed.
(a) Changeover Switch on load in open execution 4 pole, 415V, 50Hz, 160 Amps -01 No Make : L&T Cat Part No CO21600 0000 or equivalent model in Legrand/ Schnieder (b) Busbar 4 pole (three pole & one neutral) made out of laminated copper size 40mmx6mm, of length 0.8 Mtrs each (04 Nos) (c) MCCB cap 160 Amps, 4 pole, 415V, 50c/s, 35KA - 01 No, Make : L&T Cat Part No CM92152 0000X1 or equivalent model on Legrand/ Schneider for Outgoing (d) MCCB cap 100 Amps, 4 pole, 415V, 50c/s, 35KA - 01 No, Make : L&T/Legrand/ Schneider, (e) MCB TPN cap 32 Amps, 4 pole, 415V, 50c/s, 16KA - 01 No, Make : L&T/ Legrand/ Schneider, (f) MCB SPN cap 32 Amps, 'C' series - 02 Nos, Make : L&T/ Legrand/ Schneider, (g) Star/delta soft starter suitable upto 25/30 HP, 3 phase, 415V,50 c/s induction motor incl protection against over voltage, under voltage, over current, under current, reverse phasing, single phasing, earth fault with required PLC. Make : L&T or equivalent model in BCH/ Havells, (h) DOL starter suitable for 3 phase, 50 c/c, 415V not less than 2 HP induction motor - 01 No, Make : L&T or equivalent model in BCH/Havells (j) Single Phase Preventor-01
Supply, installing, testing and commissioning factory made , tested , CPRI approved powder coated LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50x50x6mm thick MS angle iron frame work, the cubical have bottom channel of size 75x40mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 50 KA thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing: (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 02 Nos
(c) Platform of Panel: Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
Ditto all as per srl no. 141 here-in-before but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing: (i) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 06 Nos
Ditto all as per srl no. 141 here-in-before but comprising with following:- (a) Incoming :- (i) ACB 4 pole, 630 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection-01 No (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing:- (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 03 Nos
Ditto all as per srl no. 141 here-in-before but comprising with following:- (a) Incoming :- (i) ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection-01 No (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1600 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing: (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 03 Nos
Ditto all as per srl no. 141 here-in-before but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing:- (i) MCCB 4 pole ,125 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 06 Nos (ii) MCCB 4 pole ,63 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 01 Nos
Ditto all as per srl no. 141 here-in-before but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 320 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing:- (i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 02 Nos
Ditto all as per srl no. 141 here-in-before but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing: (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 07 Nos
Ditto all as per srl no. 141 here-in-before but comprising with following:- (a) Incoming :- (i) ACB 4 pole, 630 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection-01 No (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing: (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 02 Nos (ii) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA thermal magnetic release - 02 Nos
Ditto all as per srl no. 141 here-in-before but comprising with following:- (a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing:- (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 09 Nos
Supply, installing, testing and commissioning in replacement factory made , tested , CPRI approved powder coated Timer panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The timer panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 40x40x6mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50x50x6mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA, with thermal magnetic release - 01 Nos (ii) 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC -01 Nos (iii) Astronomical Timer Switch 240 V AC -01 Nos (iv) Digital VAF+PF meter with RS 485 Cl-1 -01No (v) CTs ratio 100/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three (vii) Four Pole , Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing:- (i) MCCB 4 pole , 40 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 02 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
MANGLA AMIT BUILDERS PVT LTD
FRIZO INDIA PVT LTD
AMIT ASSOCIATES
mahinder pal and co
Sudhir Sharma Associates
M/s Matadeen Ramchandra Agarwal
Global Enterprises
Rabina Enterprises Pvt Ltd
Raja enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid