| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.7 LAccepted-AOC 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 1 | Accepted-AOC BEING LOWEST | |
| 2 | 2₹14.3 L+₹1.2 L (9.12%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹15.9 L+₹2.8 L (21.4%)Rejected-Finance | 3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | 4₹16.2 L+₹3.1 L (23.8%)Rejected-Finance | 4 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹17.5 L
EMD Value
₹35,000
Closing Date
12 Dec 2019, 6:00 pmClosed
GE FATEHGARH
GE MES FATEHGARH
REPAIR / RENEWAL/ REWIRING OF INTERNAL ELECTRIFICATION FITTING / FIXTURE AND CERTAIN MISC WORKS AT JCOs OR AND MES STAFF MD ACCN AT FATEHGARH CANTT
2019_MES_298198_1
GE/FAT/ET-33 OF 2019-20
Open Tender
Miscellaneous Works
Item Rate
150 days
GE MES FATEHGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE MES FATEHGARH
₹35,000
11 Jan 2020
16 Nov 2019
14 Dec 2019
16 Nov 2019
12 Dec 2019
30 Nov 2019
16 Nov 2019 - 29 Nov 2019
Amount
Taking down carefully unservicable aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan//bell/socket or power and including unscrewing from board, fitting and fixure such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified.
Taking down Aluminium sub main wiring including GI earth wire and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed by the Engr-in-Charge.
M&L for point wiring for One light/fan/bell/exhaust fan point controlled by one switch with 1100 volt grade PVC insulated-unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable, with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated-unsheathed, drawn in & including concealed PVC conduit medium grade with fittings (ISI marked) not less than 19 mm dia & 1.6 mm thick sunken pressed steel galvanised terminal boxes with top cover 2.80 mm thick ISI marked plastic laminated hylam sheet of required colour for housing/ fixing switches etc complete all as specified and directed Note- Cutting chases for concealed point wiring shall be made good by the contractor at his own cost with using Cement Mortar ( 1:4)/PCC ( 1:2:4) type B-0 (using 12.5mm graded stone aggregate) and surface finished to match the existing surface.
...ditto .. but point wiring controled by two way switch on an independent board ..ditto...
...ditto .. but point wiring for One 5 pin 5 Amp switch socket out let point on an independent board ..ditto...
...ditto .. but point wiring for One 5 pin 5 Amp socket out let point controlled by one switch on same board ..ditto...
...ditto .. But point wiring for one 15 Amp 6 Pin switch socket out let on independent board with using 2.5 Sqmm FRLS unsheathed copper conductor single core multistranded cable complete all as specified.
S&F switch piano flush type 5 Amp single pole ( ISI marked) one way complete all as specified and directed.
Fixing only switch piano flush type 5 Amp single pole ( ISI marked) one way of any description retrieved in serviceable condiiton from taking down of wirring complete all as specified and directed.
S&F switch socket combination Pin 2 in 1, 5 Amp flush type ( ISI marked) 240 Volt complete all as specified and directed.
Fixing only switch socket combination Pin 2 in 1, 5 Amp flush type ( ISI marked) 240 Volt of any description retrieved in serviceable condiiton from taking down of wirring complete all as specified and directed.
S&F switch socket combination Pin 5 in 1, 5/15 Amp flush type ( ISI marked) 240 Volt complete all as specified and directed.
Fixing only switch socket combination Pin 5 in 1, 5/15 Amp flush type ( ISI marked) 240 Volt of any description retrieved in serviceable condiiton from taking down of wirring complete all as specified and directed.
S&F switch piano flush type 5 Amp single pole ( ISI marked) two way controled complete all as specified and directed.
S&F metal clad plug & socket with metal plug top enclosure with a two pin and earth plug top and socket with & including one single pole MCB 32 Amp `C' Curve complete all as specified and directed.
M & L for lamp holder,PVC/Polycarbonate type insulated body with back plate batten/angle type for batten fittings complete all as specified & directed
S&F LED lamp of 9W and colour temp 6500K suitable to fix in angle holder complete all as specified and directed.
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
Supply and fixing of electric fan regulator 120 watts 5 stepped type stepped range hum free complete all as specified and directed .
Fixing only of electric fan regulator of any description retrieved in serviceable condiiton from taking down of wirring complete all as specified and directed .
Fixing only ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts of any description retrieved in serviceable condiiton from taking down of wirring complete all as specified and directed.
M&L for sub main wiring with using two single core 6 Sqmm (FRLS ) copper conductor PVC unsheathed cable with and including PVC conduit (appropriate size) ISI Marked medium grade not less than 19mm dia concealed in wall for sub main wiring & connections including 4.0 Sqmm (FRLS) insulated multistranded unsheathed copper conductor cable used as a earth wire to common earth and connection to earth dolly all as specified. ( Note :- Two runs of 6 sqmm (FRLS) and one run of 4.0 sqmm (FRLS) copper conductor cable & PVC conduit shall be measured as one unit length.)
S&F in replacement of VTPN DB suitable for Mounting MCCB as Incomer of rating 63 Amp Vertical distribution board 4 way with suitable Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required with & including MCCB ,63 Amp, 16 KA 4 Pole thermal magnetic release including complete electrical connection by appropriate size of copper lugs complete all as specified and directed. Conforming to Cat part No - 5077 25 of Legrand or Equivalent of other specified makes.
S&F in replacement MCB distribution board SPN 240 Volt 6 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified. Conforming to Cat part No - 5076 11 of Legrand or Equivalent of other specified makes.
S&F in replacement MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified. Conforming to Cat part No - 5076 11 of Legrand or Equivalent of other specified makes.
S&F in replacement MCB distribution board SPN 240 Volt 4 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified. Conforming to Cat part No - 5076 10 of Legrand or Equivalent of other specified makes.
S&F bell push ISI Marked 230 Volts AC supply complete all as specified and directed. .
S&F in replacement MCB SPN 40-63 Amp 240 volt 'C' curve complete all as specified and directed by the Engr-in-Charge. Conforming to Cat part No - 4086 18 to 20 of Legrand or or Equivalent of other specified makes.
S&F Call bell ding dong ISI Marked 230 Volts AC supply complete all as specified and directed. .
S&F in replacement MCB single pole 6-32 Amp 240 volt 'C' curve 10 KA complete all as specified and directed by the Engr-in-Charge. Conforming to Cat part No - 4086 87 to 95 of Legrand or Equivalent of other specified makes.
S&F in replacement of surface and wall mounted 18/20W LED extruded aluminium batten fitting including Polycarbonate LED Rod 18W complete provided for efficient heat dissipation complete all as specified and direcetd. Conforming to Cat part No - IMC50 IP 1xT-LED 22W P3241of fitting & LED Rod CAT Part No MASLEDTUBE 18W 2100 Lumens of philips or Equivalent of other specified makes.
S&F in replacement of surface and wall mounted 10W LED extruded aluminium batten fitting provided for efficient heat dissipation complete all as specified and direcetd. Conforming to Cat part No - BN021 LED10S-6500 PSU GR S1 of philips or Equivalent of other specified makes.
S&F in replacement building secrutity LED light 14 watt with IP-65 including suitable size of GI bracket complete all as specified and directed. Conforming to Cat part No - BRP 042 LED 14 CW MR S1 PSU GR of philips or Equivalent of other specified makes.
S&F in replacement surface mounted LED porch light 9 watt plastic body with cleaner prismatic diffuser all as specified and directed. Conforming to Cat part No - SM 250C LED 12S-6500 PSUWH of philips or Equivalent Model Havells/Bajaj as Approved by GE
M&L for Earthing complete with galvansied steel earth plate electrode 600 mmX600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below ground level earth plate connected with GI earthing lead 4 mm dia as earthing lead forDB etc. etc by means of bolts, nuts, check nut and washers of galavanised iron all as shown in Electrical plate No.3 of MES Sch part I ncluding bronze test point and testing on completion with & including Neccessary excavation and earth work, adequate common slat, charcoal dust and PGI funnel, PCC (1:3:6) type C-1 pit with pre-cast RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6 mm dia bars, MS bar 3 Nos both ways funnel with 20 mm dia GI medium grade watering pipe and GI protection pipe light grade 15mm dia for earth lead protection up to 7.5m. from earth plate to equipment earth point complete all as specified.
M/S J.B.AND SONS
S B ENTERPRISES
M/S BABA BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .