Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.4 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹62.3 L+₹3.0 L (4.98%)Rejected-Finance 10 SHANTI VIHAR RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹62.4 L+₹3.0 L (5.05%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹65.4 L+₹6.0 L (10.2%)Rejected-Finance PURAMUFTI NEAR GURUDWARA G T ROAD ALLAHABAD UTTAR PRADESH 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹67.8 L+₹8.4 L (14.2%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | M/S VIJAY SINGH L1 | M/S MALHOTRA ENGINEERING WORKS L6 | Unnati Engineers L7 | Ambrish Builders L5 | M/S Amar Enterprises L2 | Success PEB and Infra Consultants L8 | NSA ENGINEERING WORKS L4 | M/S SEWA AND SERVE BUILDERS L9 | Madhu Electricals and Engineering Works L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 300 | RM | 1,480 ₹4,44,000 | 1,450 ₹4,35,000 Lowest | 2,270 ₹6,81,000 | 1,740 ₹5,22,000 | 1,450 ₹4,35,000 Lowest | 1,832 ₹5,49,600 | 1,760 ₹5,28,000 | 1,950 ₹5,85,000 | 1,618 ₹4,85,400 |
| 2.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core lwith necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 350 | RM | 1,180 ₹4,13,000 | 1,130 ₹3,95,500 Lowest | 1,790 ₹6,26,500 | 1,380 ₹4,83,000 | 1,300 ₹4,55,000 | 1,467 ₹5,13,450 | 1,400 ₹4,90,000 | 1,750 ₹6,12,500 | 1,290 ₹4,51,500 |
| 3.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 975 | RM | 835 ₹8,14,125 | 760 ₹7,41,000 Lowest | 1,190 ₹11,60,250 | 804 ₹7,83,900 | 850 ₹8,28,750 | 1,011 ₹9,85,725 | 810 ₹7,89,750 | 1,200 ₹11,70,000 | 860 ₹8,38,500 |
| 4.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 575 | RM | 686 ₹3,94,450 | 615 ₹3,53,625 | 932 ₹5,35,900 | 730 ₹4,19,750 | 610 ₹3,50,750 Lowest | 801 ₹4,60,575 | 730 ₹4,19,750 | 950 ₹5,46,250 | 679 ₹3,90,425 |
| 5.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 800 | RM | 572 ₹4,57,600 | 475 ₹3,80,000 Lowest | 752 ₹6,01,600 | 698 ₹5,58,400 | 475 ₹3,80,000 Lowest | 636 ₹5,08,800 | 700 ₹5,60,000 | 720 ₹5,76,000 | 540 ₹4,32,000 |
| 6.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 500 | RM | 424 ₹2,12,000 | 360 ₹1,80,000 Lowest | 640 ₹3,20,000 | 432 ₹2,16,000 | 400 ₹2,00,000 | 485 ₹2,42,500 | 435 ₹2,17,500 | 520 ₹2,60,000 | 400 ₹2,00,000 |
| 7.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 620 | RM | 288 ₹1,78,560 | 240 ₹1,48,800 Lowest | 392 ₹2,43,040 | 319 ₹1,97,780 | 331 ₹2,05,220 | 367 ₹2,27,540 | 320 ₹1,98,400 | 415 ₹2,57,300 | 296 ₹1,83,520 |
| 8.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 880 | RM | 238 ₹2,09,440 | 220 ₹1,93,600 Lowest | 345 ₹3,03,600 | 280 ₹2,46,400 | 225 ₹1,98,000 | 301 ₹2,64,880 | 270 ₹2,37,600 | 360 ₹3,16,800 | 245 ₹2,15,600 |
| 9.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 1,600 | RM | 226 ₹3,61,600 | 199 ₹3,18,400 | 270 ₹4,32,000 | 214 ₹3,42,400 | 195 ₹3,12,000 Lowest | 260 ₹4,16,000 | 200 ₹3,20,000 | 340 ₹5,44,000 | 200 ₹3,20,000 |
| 10.00 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 1,200 | RM | 196 ₹2,35,200 | 189 ₹2,26,800 | 240 ₹2,88,000 | 201 ₹2,41,200 | 199 ₹2,38,800 | 243 ₹2,91,600 | 180 ₹2,16,000 Lowest | 190 ₹2,28,000 | 186 ₹2,23,200 |
Tender Value
₹87.3 L
EMD Value
₹1.6 L
Closing Date
17 Apr 2026, 6:00 pmClosed
CWE(AF) Bamrauli
HQ CWE(AF) Bamrauli Prayagraj-211012
SPECIAL REPAIR/REPLACEMENT OF LT CABLE IN TECH AREA UNDER GE(AF) BAMRAULI
2026_MES_757082_1
87593/C/E8
Open Tender
Civil Works
Item Rate
182 days
BAMRAULI
MES Enlisted Contractor of Class C category b i
7 documents required · 7 mandatory
₹1,000
GE(AF) BAMRAULI
₹1.6 L
Yes
26 May 2026
20 Mar 2026
24 Apr 2026
20 Mar 2026
17 Apr 2026
10 Apr 2026
20 Mar 2026 - 27 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 300 | RM | - | - |
| 2 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core lwith necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 350 | RM | - | - |
| 3 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 975 | RM | - | - |
| 4 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 575 | RM | - | - |
| 5 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 800 | RM | - | - |
| 6 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 500 | RM | - | - |
| 7 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 620 | RM | - | - |
| 8 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 880 | RM | - | - |
| 9 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 1,600 | RM | - | - |
| 10 | Supply , laying, jointing and testing in replacement of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 Core with necessary cable glands and aluminium lugs of suitable size laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and as directed. | 1,200 | RM | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
87593TENDERDOCUMENTS.pdf
Tender Documents • 1.44 MB
BOQ_848027.xls
BOQ • 1.41 MB
87593CORR2.pdf
PDF • 0.28 MB
87593CORR2.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .