Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.9 LAccepted-AOC AT PO JARANGDIH BOKARO | JARANGDIH | BOKARO | JHARKHAND | ₹4.9 L | 1 | Accepted-AOC Evaluated as L1 bidder |
| 2 | 2₹45.0 LRejected-Finance | ₹45.0 L | 2 | Rejected-Finance not L1 BIDDER |
| 3 | 3₹5.8 LRejected-Finance AT SAWANG GOMIA BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | ₹5.8 L | 3 | Rejected-Finance not L1 BIDDER |
| 4 | 4₹7.1 LRejected-Finance KATHARA DIST BOKARO 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | ₹7.1 L | 4 | Rejected-Finance not L1 BIDDER |
| 5 | Rejected-Technical CENTRAL COALFIELDS LIMITED OFFICE OF THE PROJECT OFFICER E M DEPARTMENT SAUNDA D BARKA SAYAL AREA | BOKARO | JHARKHAND | 825102 | - | - | Rejected-Technical Submitted documents checked and found not satisfactory as per NIT |
| Sl No | Description | Qty | Unit | M/s. M K ENTERPRISES L2 | SEMCO ENGINEERING WORKS L3 | M/S TIGER ENTERPRISES L1 | M/S JAY GURU CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|
| 1.01 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/Recessed PVC conduit, with Modular type Switch, phenolic laminated sheet, Suitable size M.S/PVC box and earthing the Point with 1.5sqmm. FR PVC insulated Copper conductor single core cable etc. as required. (Group –“B”) | 143 | PT | 661 ₹94,523 | 750 ₹1.1 L | 600 ₹85,800 | 850 ₹1.2 L |
| 1.02 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required (2x1.5Sq.mm+ 1.5sq.mm earth wire) | 220 | MTR | 131 ₹28,820 | 155 ₹34,100 | 130.75 ₹28,765 | 250 ₹55,000 |
| 1.03 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required (2x2.5 Sq.mm+ 2.5sq.mm earth wire) | 329 | MTR | 157 ₹51,653 | 180 ₹59,220 | 160 ₹52,640 | 225 ₹74,025 |
| 1.04 | Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x 4Sq.mm + 1x 4 sq.mm earth wire) | 123 | MTR | 192 ₹23,616 | 215 ₹26,445 | 190 ₹23,370 | 300 ₹36,900 |
| 1.05 | Supply & fixing 5 Amps. To 32Amps. Rating 240/415V. “C” curve, miniature circuit breaker suitable for Inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. ( Single pole and neutral ) | 18 | NOS | 356 ₹6,408 | 380 ₹6,840 | 130 ₹2,340 | 450 ₹8,100 |
| 1.06 | Supplying and fixing metal/PVC box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 150 mm X 60 mm deep as required. | 19 | Nos | 199 ₹3,781 | 300 ₹5,700 | 192 ₹3,648 | 400 ₹7,600 |
| 1.07 | Supplying and fixing metal/PVC box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 200 mm X 250 mm X 60 mm deep as required. | 16 | Nos | 265 ₹4,240 | 365 ₹5,840 | 261 ₹4,176 | 450 ₹7,200 |
| 1.08 | Supplying & fixing following way, single pole and neutral, sheet steel MCB distribution board, 240V. on surface recess, complete with tined copper bus bar neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required (But without MCB/RCCB/isolator) (2+4 way/6way double door) | 7 | NOS | 1,296 ₹9,072 | 1,400 ₹9,800 | 500 ₹3,500 | 1,500 ₹10,500 |
| 1.09 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (5/6 Amp Switch) | 82 | Nos | 28 ₹2,296 | 60 ₹4,920 | 25 ₹2,050 | 150 ₹12,300 |
| 1.10 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 Amps Switch | 23 | Nos | 68 ₹1,564 | 90 ₹2,070 | 67 ₹1,541 | 150 ₹3,450 |
Tender Value
₹7.3 L
EMD Value
₹9,200
Closing Date
28 Jan 2026, 10:00 amClosed
Staff Officer(ENM),Kathara Area
GM office, EnM Dept , GM Unit Kathara Area,CCL P.O Kathara Dist Bokaro
CAMC internal Electrical Repairing / rewiring and changing of electrical items as switches, switch board, earth pit and copper wire etc for electrical day to day maintenance of office building Regional Store, shed A, B,C,D,E, Receipt section ,RCC Jar
2026_CCL_351190_1
GM(KTA)/SO(ENM)/GMU/E Tender/2025-26/30 Date 13.01.2026
Open Tender
Electrical and Maintenance Works
365 days
GM Unit Kathara Area, CCL P.O Kathara Dist Bokaro
A s Per NIT
5 documents required · 5 mandatory
₹9,200
31 Mar 2026
14 Jan 2026
29 Jan 2026
15 Jan 2026
28 Jan 2026
15 Jan 2026
15 Jan 2026 - 27 Jan 2026
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper Conductor single core cable in surface/Recessed PVC conduit, with Modular type Switch, phenolic laminated sheet, Suitable size M.S/PVC box and earthing the Point with 1.5sqmm. FR PVC insulated Copper conductor single core cable etc. as required. (Group –“B”)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required (2x1.5Sq.mm+ 1.5sq.mm earth wire)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVC Conduit as required (2x2.5 Sq.mm+ 2.5sq.mm earth wire)
Wiring for circuit/sub main wiring along with earth wire with the following sizes of PVC insulated copper conductor, single Core cable in surface/recessed PVCConduit as required (2x 4Sq.mm + 1x 4 sq.mm earth wire)
Supply & fixing 5 Amps. To 32Amps. Rating 240/415V. “C” curve, miniature circuit breaker suitable for Inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. ( Single pole and neutral )
Supplying and fixing metal/PVC box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 150 mm X 60 mm deep as required.
Supplying and fixing metal/PVC box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 200 mm X 250 mm X 60 mm deep as required.
Supplying & fixing following way, single pole and neutral, sheet steel MCB distribution board, 240V. on surface recess, complete with tined copper bus bar neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required (But without MCB/RCCB/isolator) (2+4 way/6way double door)
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (5/6 Amp Switch)
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 Amps Switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. ….5/6Amps. Socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 Amps Socket
Supplying and fixing of modular type electronic regulator Supplying & fixing stepped type electronic fan type regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing following rating, four pole, (single phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 AMP
Supplying of 3 pin, 5 amps. ceiling rose on existing junction box/ wooden block excluding connection etc. as required
Supplying and fixing brass batten/ angle holder including connection etc. as required
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr. long etc. with charcoal/coke and salt as required
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Details of cost for 1 Metres
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. For 32 Amp TP&N
Supplying and fixing of following sizes of medium class PVC conduit/ cashing along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.(20mm dia PVC conduit/ cashing )
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.100 Amp TPN switch
Providing of 6 sq mm ttwin core copper cable 1100 Volts grade single phase and neutral.etc as required.
Providing of fall ceiling panel light 36W and 220V (2 feet x 2 feet)squre type for lab and offices
Providing of surface ceiling light of 18W and 220V (circular type)
Providing of electric Siren 2 KM range singel phase 1/2 HP , 230 Volts for Regional Store Kathara.
Labour cost of above items no 25,26,27 & 28
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.45 MB
BOQ_363945.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid