Tender Value
₹24.0 L
EMD Value
₹48,000
Closing Date
15 Jul 2023, 2:00 pmClosed
Executive Engineer ED Kathua
Executive Engineer ED Kathua
Erection of 630KVA 11KV Sub Station along with HT Cable including CT PT for Build AC Electric Buses and allied infrastructure at Kathua under Jammu Smart City Mission in respect JPDCL Electric Division Kathua.
2023_PDD_218156_1
KED 08 of 2023 24 Dated 22.06.2023
Open Tender
Electrical Works
Turn-key
90 days
Kathua
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer ED Kathua
₹48,000
19 Aug 2023
22 Jun 2023
17 Jul 2023
22 Jun 2023
15 Jul 2023
22 Jun 2023
22 Jun 2023 - 15 Jul 2023
Amount
Creation of 630 KVA Sub Station E-Buses Charging point new Bust stand Kathua in respect JPDCL Electric Sub Division Kathua on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 630 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Copper Wound and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
400 mm² (2 Ckt) cable,1.1 K V Grade, PVC Insulated Stranded Conductor FRLS type.
9 Mtr. Long pole (ST-410 SP 33)
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Transformers Pad / GI Channel Bedding
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 630 KVA DTR with MCCB for incommer and SFU's for outgoing Ckt
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for anti Clambing
3 Ph 4 Wire Trivector meter with CT
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole
Painting of poles Red oxide
Painting of poles Aluminum Paint
Sundary items like Aluminium Lugs, Jumpers , binding tape
Erection of 70 Mtr 120 MM2 HT cable for E-Buses Charging point for New Bus stand Kathua in respect JPDCL Electric Sub Division Kathua on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11 Mtr. Long pole (ST-410 SP 56)
120 MM2 AB (HT ) Cable (3x50+1x90mm2) XLPE (11 KV, 3C+Earth) (2x145=290 Mtr)
Heat Shrinkable outdoor Cable Termination Kit.
Supsension/Tension clamps with eye Hook
Gulvanized Nuts and bolts
Danger Plates
Anti Climbing Device
Red oxcide Paint
Aluminium Paints
Cement Bottoming 1:2:4 mix as per REC Standrad 0.6 CUM per pole
Installation 11 KV CT / PT alongwith Trivector meter at E-Buses Charging point for New Bus stand Kathua in respect JPDCL Electric Sub Division Kathua on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11KV Pilfer resistant metering cubicle for 3 phase 4 wire metering system of Ms sheet steel thickness not than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement . The cubicle shall be painted through7-tank process. The External diametions should be adwquate. panl have two compartment upper meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gas cut firmly flued to the surface. Dust weather and vermic proof and shall somply degree of protecion IP 65 both the chamber having one side hinged door arrangement. The metering panel shall be provided with two no Ms Channle of size 100x50mm on the front ane rear side duly welded and 4 No. of lofting hooks. It should be possible to take meter reading manually. through CMRI and computer with out operating the LV chamber door.
Single Phase. Single Core, Single ratio, Epoxy resin Cast current transformers suitable for 11 KV, copper wound primary type with rated buden 5 VA and accuracy class 0.5 or better and conforming to IS 2705 (Part-i & ii) amended upto date ISF shall be upto 5 the CT ratio shall be as under:- i) 2.5/5 for 25 KVA DT
11 KV/110 V, three phase epoxy resin sast PT rated burden 15 VA per phase and accuracy class 0.5 better and conforming to IS :3156(part I & II) emended upto date with proper clolour coded identification . PTs shall be uniform insulating and withstands seprate source 23 KV pf for one minute
Bus bar details. CTs bus bar- 40x6 mm copper strip of adequate size. PTs bus bar. Copper wire 8 SWG of 30x0.6 mm copper flat strip to connect PT terminal of adequate size. Duly Insulated by the monoplast tape.
PVC copper wire flexible multi-stand of required size secondary connection for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5mm2 (RYB)
Copper lugs preferable ring duly crimped for termination of wire and tape.
Grounding bus of minimum 40mm copper, 25 CM long fixed to the unit in HV chamber. The CTs, PT meter and 11KV cable sheath shall be grounded to the bus through grounding wire (green) of Min size 10mm2
3 Phasse 3 wire HT CT/PT operated fully static smart Tri-vector meter DLMS complaint category "C" with RS 232 port for modern compatibility 11 KV/110V, ph-ph(3 ph,3w) meter for measurement of different electrical parameters including active energy (K Wh/MWh). Rective energy (kVAh/MVAh)
Independent flexble PVC pipe for CT wiring and PT wiring of aooroprate size from HT compartment to meter compartment
Pedestal made out of MS Channel of size 75x40mm or angle iron of size 65x65x5 mm duly painted as per site requirement for mounting of metering panel including concrete foundation wherever required including cost of nuts and bolts.
3 core 11 KV aluminium cable XLPE armoured 35mm2 including cost of clamp for its fixing where required.
Cable termination kits suitaable for 3c 35mm2 XLPE cable (indoor/outdoor)
Earthing 40mm GI pipe of 20mm GI rod, 2.5 Mtr for metering unit. Earthing of metering cubicl through two No. 25x5 mm flat iron.
M/S ROHIT ASSOCIATES
JAI CHANDI MAA ENTERPRISES
m/s asha nand
RAGHBIR SINGH
M/S MAHALAXMI ENTERPRISES
power control system
M/S BETTER CHOICE AGENCIES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .