14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer should have minimum eligibility criteria as given below: Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any of the following (by any Government organizations) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works each costing not less than the amount equal to 30% of advertised value of tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turn over of Rs.500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of Similar Nature of work:Any CLS or RI or EI or IBS/IBH or ABS work involving indoor signalling system. OR Any such work involving activities as given in the name of the tendered work. Note: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/40/60 per cent (as the case may be) criteria of similar nature of work.
26 conditions · 16 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Care In Submission of Tender : (In terms of Railway Board letter NO : 2017/CE-I/CT/4/GST dated : 23.06.2017)
(i) Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer.
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017 (CGST)/Integrated Goods and Services Tax Act, 2017 (IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderer will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under CGST/IGST/UGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UGST/SGST Act to railway immediately after the award of contract without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority
In case the successful tenderer is not liable to be registered under CGST/IGST/UGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority
Design, execution, testing and commissioning of alteration in SIEMENS RRI at Old Delhi Railway Station & Auto section between Subzimandi station and Delhi Adarshnagar station along with part supply of material i.c.w EI at Subzimandi station of Delhi Division of Northern Railway.
Project_DLI_SNT_01~NR
Project_DLI_SNT_01
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹2.1 L
2 Jan 2026
11 Dec 2025
19 Dec 2025
65 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,26,82,407.52 | ||
| — | 2.00 | — | — | ||
| Supply and installation of Relay Rack Assembly including IDF pillars if any complete with scaffolding, ladders, runway fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Rack should be made of first class steel powder coated painting and rack manufacturer's certificate should be submitted. Inspection: Consignee | — | — | — | 67,124.72 | |
| — | 20.00 | — | — | ||
| Supply of 200 way tag blocks with PVC cover conforming to drg no. SA-24753 or latest and as per IRS-S-77/2006 (Rev) or latest. Inspection by RDSO. | — | — | — | 47,055 | |
| — | 26.00 | — | — | ||
| Fixing, wiring & soldering of tag blocks with PVC cover on cable termination rack/relay rack/block rack/HV rack as per Drg no. NR/S&T/CON/4.3/97A.All fixing material like flats , bolts, nuts , washers, plastic tage block cover for tag block etc will be supplied by contractor. Inspection : Site Engineer. | — | — | — | 5,236.4 | |
| — | 4.00 | — | — | ||
| Fabrication, supply and fixing of cable termination board of size 2200mmx900mm as per Drg. No. NR/SandT/CON/4-1/97A made of angel iron size 40mmx40mmx5mm alongwith outer frame made of angle iron size 65mmx65mmx8mm duly fitted with Bakelite sheet (HYLAM MAKE or similar ) of size 6mm thick. This also includes fixing of ARA terminals/strips/Wago connectors and fuse bases etc. Supply and fixing of hard wood of size 70cmx25cmx5cm in the back at bottom for jamming of armour of cables, each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering. All the fixing materials like bolts, nuts, washers, Insulators, shoe, angle irons, flats, L- bolts, Catenary wires and cement concretes etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting and description etc. with ISI mark paints. (Inspection : Site Engineer) | — | — | — | 86,642.8 | |
| — | 6.00 | — | — | ||
| Supply of 96 way tag blocks with PVC cover conforming to IRS-S-77/2006 (Rev) or latest. Inspection by Consignee | — | — | — | 14,727.72 | |
| — | 40.00 | — | — | ||
| Relay base plate complete with amphanols,code pins, fixing screws etc.suitable for Metal to Metal K-50 mini groups of Siemens Make orfunctional equivalent of othermakes.Inspection: Consignee | — | — | — | 37,638.8 | |
| — | 2.00 | — | — | ||
| Supply of Indoor Cable 1x60Cx0.6mm dia Asper IRS -S-76/89. Inspection RDSO | — | — | — | 4,70,294.5 | |
| — | 2.00 | — | — | ||
| Supply of Supply of PVC jumper wire 1x0.6mm dia. Inspection Consignee | — | — | — | 10,468.34 | |
| — | 2.00 | — | — | ||
| Supply of Flexible , PVC sheathed, PVC insulated Copper wire 16/0.20 mm (wiring materials) as perIRS spec. No. IRS-76/89 with amendment no.3 orlatest. Inspection :RDSO | — | — | — | 17,256.62 | |
| — | 20.00 | — | — | ||
| Supply of Plug In type Relay Metal to Metal type neutral relay mini groups Siemens make(No. RSSK 30/0011) .or functional equivalentwithout base plates.Contact configuration5F/3B or 6F/2B or 4F/4B to be specified bySite Engineer. Inspection: RDSO | — | — | — | 2,22,022.4 | |
| — | 10.00 | — | — | ||
| Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (AC Immunised-1) Siemens make (No. RSSK30/0078-1) (Ref. IRS:S46).or functionalequivalent without base plates.Contactconfiguration 5F/3B or 6F/2B or 4F/4B to bespecified by Site Engineer.Inspection: RDSO | — | — | — | 1,19,136.5 | |
| — | 10.00 | — | — | ||
| Supply of Plug In type Relay Interlocked Siemens make (No. RSSK 30/0012) or functional equivalent Inspection: RDSO | — | — | — | 1,11,601.8 | |
| — | 30.00 | — | — | ||
| Supply of AC Universal LED ECR conforming to A-RT-RG-A064 for 110 V AC LED Lighting units or Equivalent. Inspection: RDSO | — | — | — | 2,41,999.5 | |
| — | 40.00 | — | — | ||
| Relay, AC Immunized, plug in type, style "QNA1" DC neutral line 24VDC, 8F/8b contact, front and back contact metal to carbon with plug board, retaining clip and connector a conforming to BRS:931A IRS:S- 60 - 78 IRSS - 34 - 68 IRS:S-23 (as aplicable).The interlocking code for this unit shall be ABDGH or latest Inspection: RDSO | — | — | — | 1,64,558 | |
| — | 2.00 | — | — | ||
| Supply of Time Element Relay (Clock work type) AG timer Siemens Make (No RSSK30/0052).Inspection: Consignee | — | — | — | 21,640.76 | |
| — | 1.00 | Lumpsum | — | ||
| Modification of Design (Alteration) of routerelay interlocking circuits (Siemens Make) of DLI station in c/w SZM-EI work including modification of locking table, circuit diagram,wiring diagram, contact analysis chart etc.This includes complete wiring work in c/w alteration work, alteration and validation of data logger. All necessary card for datalogger if required will be supplied by the contractor.Note: This includes supply of completion 6 sets as per tender condition. Inspection: Site Engineer | — | — | — | 47,20,000 | |
| — | 1.00 | Lumpsum | — | ||
| Supervision, testing & commissioning of RRI system by OEM. All testing arrangement has to be done by contractor itself by means of simulation panel and lamp board as required. Inspection Site Engineer | — | — | — | 47,20,000 | |
| — | 1.00 | Lumpsum 185169.11 | — | ||
| Alteration in existing control panel and indication Panel and wiring of the same. This includes supply fabrication and installation of dominos as required. Inspection: Site Engineer | — | — | — | 1,85,169.11 | |
| — | 1.00 | — | — | ||
| "Designing , preparation of locking table, selection table, circuit diagram, contact analysis chart, relay rack chart etc; preparation of operating & indication panel Domino type diagram, (circuit shall be designed by the contractor with the use of Q series/K-Series relays on the basis of approved signal Interlocking plan and obtaining approval of Competent Authority). The operating & indication panel may have addition & alteration to an extent of 5% variation in number of Domino. Designing should be as per Railway specifications and as per latest rules prescribed by Rly. This also includes preparation of cable route plan, Cable core chart, Station working rule diagram, Power supply arrangement, Cable termination chart in relay room and location boxes, Location wiring plan, Cable insulation chart, Fuse analysis, Indoor circuit diagram, Track circuit jumper plan, Terminal and Contact analysis chart, Outdoor circuits and other outdoor diagrams and obtaining approval of the engineer as per following :-(i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover. (ii) Software back up of complete set in the form of CDs. (iii) One complete set of tracings. (iv) Design through CAD(v) Drawings in A3 & plans in bigger size. (six sets). (Inspection: Site Incharge)" | — | — | — | 51,039.36 | |
| — | 6.00 | — | — | ||
| Fabricating, writing and fixing of description boards made of ply 6mm thick with white sunmica glued over its surface and 1"x1"wooden baton fitted all around on the rear and having aluminum angle size of25.4mmx25.4mmx3.15mm on all four sides asper instruction of Engineer at site. All the materials to be supplied by contractor.(Inspection : Site Engineer) | — | — | — | 15,599.04 | |
| — | 50.00 | — | — | ||
| Wiring of relays in relay room/relay huts as per approved wiring diagrams. All wiring material including resistances and condensers etc. except cables/wires to be supplied by contractor(supply of cables & wires covered separately). It includes dressing, bunching , lacing and fixing of relay bases. Inspection : Site Engineer. | — | — | — | 23,693 | |
| — | 100.00 | — | — | ||
| Supply of electric fuse complete with fuse block(base) for Railway signalling non- deteriorating type low voltage fuse assembly2Amp/4Amp/10 Amp/16Amp. to suit . Spec.No.IRS: S- 78/2006 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006(Rev-2 and Amd 2 ) and drg no. 23748 (IRS)Alt.4 or latest. Fuse block shall be suitable for round head type fuses. Rating : 2Amp/4Amp/10 Amp/16Amp'. (Inspection : RDSO) | — | — | — | 19,904 | |
| — | 100.00 | — | — | ||
| Preparation of SWR Translation of SWR from English to Hindi. : Inspection by JE/SSE/Project/D&D. | — | — | — | 2,213 | |
| — | 100.00 | — | — | ||
| Typing and Printing One master Copy SET in Hindi. Inspection by JE/SSE/Project. | — | — | — | 2,414 | |
| — | 300.00 | — | — | ||
| Photocopies of Hindi Master Copy Set Inspection by JE/SSE/Project. | — | — | — | 468 | |
| — | 6.00 | — | — | ||
| Spiral Binding of master of SWR as above including plastic cover. Inspection by JE/SSE/Project/D&D. | — | — | — | 342.24 | |
| — | 2.00 | — | — | ||
| Supply, Installation, Wiring, Testing, Validation and Commissioning of 512 port digital input and 32 port analog input datalogger having interface with PI with built in network internal modem and power supply as per RDSO Specification No. IRS : S-99/2006 (Amend-3) or latest amendments or as per latest specification. Interfacing and networking of datalogger with central monitoring shall be done by contractor. This also includes Protocol convertor for dataloggers at main cabin & relay huts. This also includes supply and installation of one Data logger each at Station having 512 Digital inputs and 32 Analog Inputs along with supply of one PC for each Datalogger with monitor of minimum 32" size (specs of computer is given in tender document) along with data logger failure analyser system, UPS/Inverter & furniture i.e. table & chair for PC,UPS and Monitor of Datalogger and A4 laser printer.(Inspection: RDSO) | — | — | — | 12,22,331.12 | |
| — | 200.00 | — | — | ||
| Supply of 4 conductor disconnect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm center marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carrier rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Rev. 3.0 or latest. (Inspection by- RITES). | — | — | — | 25,228 | |
| — | 50.00 | — | — | ||
| Supply of Steel carrier Rail 35x7.5mm/0.039 in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. (Inspection by- Consignee) | — | — | — | 7,847.5 | |
| — | 50.00 | — | — | ||
| Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. (Inspection by- Consignee). | — | — | — | 982 | |
| — | 50.00 | — | — | ||
| Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Rev. 3.0 or latest. (Inspection by- Consignee). | — | — | — | 860.5 | |
| — | 1.00 | — | — | ||
| Supply of SM/SI/ESM furniture of Godrej or similar make consisting of the following :- 1. Executive revolving bearing series low back floating chair with normal arms cushioned chair: 1 No. 2. Executive Table size 72x36x30" with 3 drawers one side, lockers cabinet on other side: 1 No. 3. Visitors chair seat & back cushion with high density Foam with plastic PVC handle capsule type flat pipe duly painted black: 3 Nos.4. Almirah steel with locking arrangment size 1145mmx460mmx750mm=1No. (Inspection: Consignee/Site Incharge) | — | — | — | 46,912.79 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .