Tender Value
₹4.1 Cr
EMD Value
₹3.6 L
Closing Date
16 Jan 2026, 11:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER
14 conditions · 2 needing a document upload
10.2.The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where. V=Advertised value of the tender in crores of Rupees. N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turn over. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported byAudited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. b(1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows. The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as
Defination of Similar Work :- Execution of Panel Interlocking or Electronic Interlocking with MACLS either Indoor or Outdoor works or Both. OR Alteration to Existing Panel Interlocking / Electronic Interlocking with MACLS either Indoor or Outdoor works or Both. OR Provision of IBS works in panel Interlocking or Electronic Interlocking sections. OR Provision of Automatic signalling with Axle counter/Track circuits or both together. OR Provision of UFSBI/BPACs/Digital Axle counters at Panel Interlocking stations/Electronic interlocking stations.
8 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer has to go through the General Technical Conditions and Specifications and Drawing as stipulated in Annexure - XVII of the Tender Document and comply
As per GCC Clause 14.0 Documents to be Submitted Along with tender. (i)The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the Constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
ii) Following documents shall be submitted by the tenderer: (a)Sole Proprietorship Firm: (i) All documents in terms of Para 10of the Tender Form (Second Sheet) above. HUF: (ii)A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (iii)All other documents in terms of Para 10 of the Tender Form (Second Sheet) above. (c) Partnership Firm: (i) All documents as mentioned in para18 of the Tender Form (Second Sheet). (d) Joint Venture (JV): All documents as mentioned in para 17 of the Tender Form (Second Sheet). (e) company registered under Companies Act 2013: (i)The copies of MOA(Memorandum of Association) / AOA (Articles of Association) of the company (ii)A copy of Certificate of Incorporation (iii)A copy of Authorization/Power of Attorney issued by the Company(backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv)All other documents in terms Para 10 of the Tender Form (Second Sheet) above. (f) LP Limited Liability Partnership): If the tender is submitted on behalf of a LLP registered under LLP Act-2008, the tenderer shall submit along with the tender: (v)A copy of LLP Agreement (vi) A copy of Certificate of Incorporation (vii)A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (viii)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/ members. Concealment /wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (ix)All other documents in terms of Para10 of the Tender Form (Second Sheet). (g)Registered Society &Registered Trust: The tenderer shall submit: (x)A copy of the Certificate of Registration (xi) A copy of Memorandum of Association of Society/Trust Deed (xii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (xiii)A copy of Rules & Regulations of the Society. (xiv) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above (iii) If it is NOT mentioned in the submitted tender that tender is being submitted on behalf of a Sole proprietorship firm / Partnership firm / Joint Venture / Registered Company etc., then the tender shall be treated as having.
GCC Clause No.15. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association/Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Apostille certificate
As per GCC Clause No.18.10 The tenderer shall clearly specify that the tender is submitted on behalf of a partnership firm. The following documents shall be submitted by the partnership firm, with the tender: (i) A notarized copy of partnership deed or a copy of the Partnership deed registered with the Registrar.. (i) A notarized or registered copy of Power of Attorney (duly registered as per prevailing law) in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (ii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry/Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract.
As per GCC 2022): The tenderers shall submit a copy of certificate stating that all their statements/ documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V (Annexure-V of GCC April 2022). Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid (Clause 6.1 of GCC2022 PART-I) ( Click here to download Format) ( Click here to download Format)
Tenderer has to go through the Technical Specifications as stipulated in Annexure - XVIII of the Tender Document and comply
Hyderabad Division: (1) SC-DHNE section: Falaknuma - Making Road No. 5 & 6 as Full Length Dead-End Spur, (2) Falaknuma - Conversion of existing Road No. 6 & 7 into R&D Line and Provision of One Dead-End Spur & (3) Repais/replacement of defective Signal Cables at Interlocked LC Gate Locations - Signal and Telecom arrangements
Y-SG-36-2025-26-29~SCR
Y-SG-36-2025-26-29
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹3.6 L
16 Jan 2026
15 Dec 2025
2 Jan 2026
137 items across 8 schedules · ₹4,12,05,519.15 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of CLS Post 140mm Dia to Specn IRS:S 6-81 Rev.3 or latest - 3.5m Long (Inspection: RITES). | Numbers | 7.00 | 4,442 | 31,094 |
| 2 | Supply of CLS Ladder for 3.5m post as per Drg No. SA 23150, 5 2033 or latest (Inspection: RITES).. | Set | 7.00 | 5,226 | 36,582 |
| 3 | Supply of Suiface Base 140mm Dia CLS post as per Drg No. 52011/M (Inspection: RITES). | Numbers | 7.00 | 3,476 | 24,332 |
| 4 | Supply of Metallic (MS) Colour Light Signal Unit 2 Aspect complete as per Drg No. SA.23003/AIM (Adv.) with latest amendment and specification IRS: 5 26-64 or latest (Inspection: RITES). | Numbers | 7.00 | 12,998 | 90,986 |
| 5 | Supply of Offset Bracket to suit 140mm Dia CLS post with two numbers of U bolts and nuts complete (Inspection: RITES). | Numbers | 6.00 | 4,938 | 29,628 |
| 6 | Supply of Ground type Position Light Shunt Signal complete with base, pipe, arrow mark and hoods as per RDSO Drg No. SA 23840 or latest (Inspection: RITES). | Numbers | 3.00 | 6,083 | 18,249 |
| 7 | Supply of Post type Position Light Shunt Signal with hoods, arrow mark and offset bracket to suit 90mm sockets (CLS) with two numbers of 'U' bolts and nuts complete to fix shunt signal below main stop signal as per ROSO Drg No. SA 23840 or latest (Inspection: RITES). | Numbers | 3.00 | 3,502 | 10,506 |
| 8 | Supply of Junction type I Direction type Route Indicator as per Specn IRS:S 66-84 Amd.1 or latest - Three way as per Drg No. SA 23403 (Inspection: RITES). | Numbers | 2.00 | 24,051 | 48,102 |
| 9 | Supply of Calling On Signal Unit complete with U Bolts as per RDSO Drg No. SA.24351 (Adv.) or latest (Inspection: RITES). | Numbers | 3.00 | 4,740 | 14,220 |
| 10 | Supply of 'E' type lock of specified ward as per requirement with one key E-type lock to Drg No. SA3376/M or latest and Specn IRS: S30-64 or latest. (as specified by site/store incharge) (Inspection: RITES). | Numbers | 29.00 | 1,051 | 30,479 |
| 11 | Supply of Relay fixing Frame for Full Location Box. The Frame shall be of approximate size 940mm x 150mm and made with powder coated MS Angle of 25mmx25mmx3mm. The Frame shall have suitable holes to fix in Full Location Box (Inspection: Consignee). | Numbers | 25.00 | 853 | 21,325 |
| 12 | Supply of Relay fixing Frame for Half Location Box. The Frame should be of approximate size 470mm x 150mm and made out with powder coated MS Angle of 25mmx25mmx3mm. The Frame should have suitable holes to fix in Half Location Box (Inspection: Consignee). | Numbers | 4.00 | 427 | 1,708 |
| 13 | Supply of Track Lead Junction Boxes Fibre Glass as per Drg No. CWM-00597 of FRP material to and Specn IRS:S 23 along with fixtures i.e., one MS angle 50mmx50mmx 5mm, 0.9m long, two numbers of GI pipes of 25mm Dia, 500 mm long along with nuts and bolts and 500 mm long (grommet bushes, 60 mm ARA terminals-2 Nos) (Inspection: Consignee). | Numbers | 104.00 | 1,546 | 1,60,784 |
| 14 | Supply of 'B' type Chokes to as per Specn IRS: S65-83 Amd.l or latest (Inspection: RDSO). | Numbers | 52.00 | 2,313 | 1,20,276 |
| 15 | Supply of Stationary Low Maintenance Secondary Lead Acid Cells as per RDSO Specn IRS:S88-2004 or latest. This includes supply of inter cell connectors, bolts, nuts, Acid level indicating floats and vent plugs - 2V, 80AH (Inspection: RDSO). | Numbers | 104.00 | 3,315 | 3,44,760 |
| 16 | Supply of Distilled water for topping of Secondary Cells as per Specn IS 1106 or latest (Inspection: Consignee). | Litre | 2000.00 | 10 | 20,000 |
| 17 | Supply of Porcelain Insulators for Secondary Lead Acid Cells (Inspection: Consignee). | Numbers | 104.00 | 30 | 3,120 |
| 18 | Supply of Track Feed Regulating Resistance Disk Type 00 to 300 as per Drg No. SA 20161 66/M or latest. To be procured from RDSO approved firms (Inspection: Consignee). | Numbers | 100.00 | 358 | 35,800 |
| 19 | Supply of Plug-in type miniature tractive armature Non-AC immune, DC Neutral Line Relay complete with plug board, retaining Clip/ATC Clip and connectors as per Specns BRS 930, lRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS: S67-85 Amd.3 or latest (as applicable) - QN1- 8F/8B, 24 V DC. The interlocking code: ABODE (Inspection: RDSO). | Numbers | 40.00 | 4,400 | 1,76,000 |
| 20 | Supply of Plug-in type miniature tractive armature Non-AC immune, DC Neutral Line Relay complete with plug board, retaining Clip/ATC Clip and connectors as per Specns BRS 930, lRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QNI- 12E/4B, 24 V DC. The interlocking code: ABODE (Inspection: RDSO). | Numbers | 40.00 | 4,283 | 1,71,320 |
| 21 | Supply of 24 V DC Plug-in type miniature tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QBCA1- 2HF/4B, Interlocking code: BCEJK as per Specns BRS 943 or latest (Inspection: RDSO). | Numbers | 20.00 | 8,307 | 1,66,140 |
| 22 | Supply of 24 V DC Plug-in type miniature tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QNA1- 8F/8B, Interlocking Code: ABDGH as per Specn BRS 931 A or latest (Inspection: RDSO). | Numbers | 40.00 | 4,738 | 1,89,520 |
| 23 | Supply of 24 V DC Plug-in type miniature tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QNA1 - 12F/4B, DC Neutral Line Relay, Interlocking Code: ABDFH as per Specn BRS 931 A or latest (Inspection: RDSO). | Numbers | 40.00 | 4,413 | 1,76,520 |
| 24 | Supply of 24 V DC Plug-in type miniature tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QNA1 K-6F/6B, Interlocking Code: CDEKY as per Spec BRS 931 A or latest and RDSO letter No. STS/E/Relays/UEA (P1), dt.30.05.97 (Annexure-Il) (Inspection: RDSO). | Numbers | 40.00 | 5,062 | 2,02,480 |
| 25 | Supply of 24 V DC Plug-in type miniature tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QSPA1- 8F/4B, The interlocking code: ABDEJ, Spec BRS 933A or latest (Inspection: RDSO). | Numbers | 35.00 | 6,465 | 2,26,275 |
| 26 | Supply of AC immune, plug-in type, Style 'QTA2', 2F/1 B DC Neutral track relay for Rly Signalling track circuits with coil resistance 9 ohm, complete with plug board, retaining clip and connectors as per specifications: BRS 939A & 966 or latest, IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S67-85 Amd. 3 or latest (as applicable) with interlocking code FGHKX (Inspection: RDSO). | Numbers | 40.00 | 4,806 | 1,92,240 |
| 27 | Supply of ECR 4E/4B' for 110V AC lit LED signals, complete with plug board, retaining clip and connectors as per RDSO Specn No. STS/E/Relays/ AC Lit LED Signal/09-2002 Amd.1 or latest, BRS 941A, IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S67-85 Amd.3 or latest (as applicable). The interlocking code for this unit shall be ABDHK (with ATC clips) (Inspection: RDSO). | Numbers | 50.00 | 5,841 | 2,92,050 |
| 28 | Supply of Housing Rack for 1-9 Multi Lamp Route Indicator of 2mm MS thick sheet with mounting Socket on Signal Post (LED single digit) (Inspection: Consignee). | Numbers | 2.00 | 20,309 | 40,618 |
| 29 | Supply of Vitreous Enamel Coated Board of 230mm Dia (A, P, G, C, lB Markers) made of 2mm thicksheet as per following colour scheme: 1) 'G' Marker - Yellow back ground, Black letters 2) Other boards - White background, Black letters (Inspection: Consignee). | Numbers | 8.00 | 267 | 2,136 |
| 30 | Supply of 280mmx102mmx2mm thickness Vitreous Enamel Coating Arrow Markers Board fabricated with MS Clamp of size 40mmx6mm along with suitable bolts and nuts (Inspection: Consignee). | Numbers | 8.00 | 370 | 2,960 |
| 31 | Supply of Ground connections for Point Machines - Ground connections for Universal Point Machine 143 mm with 'D' type clamp for 52 Kgs/60 Kgs/90R rail as per Drg No. RDSO/S3267-74 (Inspection: RITES). | Set | 16.00 | 8,670 | 1,38,720 |
| 32 | Supply of Insulations for Ground connections Drive lug insulation for Universal Point Machine as per Drg RDSO/S 3361@45>46@ (One set consists of one number central insulation plate, bushes-2 Nos. and washer-4 Nos.) (Inspection: RITES). | Set | 16.00 | 160 | 2,560 |
| 33 | Insulations for the Ground connection for Point Machine comprising of the following:1) Switch extension piece insulation -1 set (Each set comprising of S3265-1 No.; S 3266-1 No.; S23199-2 Nos. and 58640-4 Nos.).2) Stretcher bar insulation-3 Sets (Each set consisting of T10367-1 No., T10368-2 Nos., T10371-4 Nos.).3) Gauge tie plate insulations-4sets (Each set consisting of T10372-1 No., T10368-3 Nos. and T10371-6 Nos.).4) Drive lug insulation-i set (Each set consisting of S 8804-1 No., S 8813-2 Nos. and S 8640-4 Nos.) complete with bushes.Note: The type of insulation required will be specified by Engineer in-charge of the work depending on the type of Machine proposed (Universal/PTJ Make) as per specification (Inspection: RITES). | Set | 16.00 | 2,203 | 35,248 |
| 34 | Ground connection insulations for thick web switch layout facing point (BG) for 52 Kgs/60 Kgs Rail fitted with high thrust Point Machine comprising of the following: 1) Bush as per Drg No. S3463-1 No. and Washer as per Drg No. 58640-2 Nos. for drive (throw) rod. 2) Bush as per Drg No.S23199-1 No. and Washer as per Drg No. S8640-2 Nos. for short detector rod. 3) Bush as per Drg No. S23199-1 No. and Washer as per Drg No. S8640-2 Nos. for long detector rod. 4) Bush as per Drg No. S22179-1 No. and Washer as per Drg No. S8640-2 Nos. for short lock rod. 5) Bush as per Drg No. S22179-1 No. and Washer as per Drg No. S8640-2 Nos. for long lock rod. 6) Bush 'B' as per Drg No. S8912 for LH lock slide-1 No. 7) Bush 'B' as per Drg No. S8912 for LH lock arm-2 Nos. 8) Bush 'B' as per Drg No. S8912 for RH lock arm -2 Nos. 9) Bush 'B' as per Drg No. S8912 for RH lock slide-1 No. 10) Bush as per Drg No. S23199-4 Nos. and washer as per Drg No. S8640-4 Nos. for LH lock slide. 11) Insulating Plate LH as per Drg No. S3404 RDSO/ S 3593-1 No. 12) Insulating Plate RH as per Drg No. S3404 RDSO/ S3592-1 No. 13) Bush as per Drg No. S23199-4 Nos. and washer as per Drg No. S8640-4 Nos. for RH lock slide (Inspection: RITES). | Set | 8.00 | 1,074 | 8,592 |
| 35 | Supply of powder coated Cable Termination Rack of size 880mmx2075mm made using 50mmx50mmx 6mm (6mm thickness) MS angles. The Cable Termination Rack shall be supplied with stainless steel nuts and bolts for fixing the Rack, tripod bases and reel insulators (for K Rack, P Rack and Power Rack), Cable Ladder of 400mm width and 2075mm length with two angles of size 40mmx40mmx5mm (5mm thickness) and supporting flats of size 25mm x 25mm. Suitable holes shall be drilled to fit hylam sheet as per standard practice (Inspection: Consignee). | Numbers | 2.00 | 7,585 | 15,170 |
| 36 | Supply of Terminal Block: 1 way Poly Butylene Terephthalate (PBT) of size 60mm (link centre to centre) as per RDSO Drg No. SA23745/Alt.5 or latest, SA23746/Alt.5 or latest, S23747/Alt.5 and Specns IRS: S75- 2006 Rev.2.0 (Tentative) or latest, IRS: S23-88 Amd.1 or latest (Inspection: RDSO). | Numbers | 350.00 | 97 | 33,950 |
| 37 | Supply of Terminal Block: 6 way Poly butylene Terephthalate (PBT) of size 25mm (link centre to centre) as per RDSO Drg No. SA23756/Alt.3 or latest, S23757/Alt.4 or latest and Specns IRS:S 75- 2006 Rev.2.0 (Tentative) or latest, IRS:S23-88 Amd.1 or latest (Inspection: RDSO). | Numbers | 750.00 | 406 | 3,04,500 |
| 38 | Supply of Modular Terminal Block (WAGO or similar) as per RDSO Specn RDSO/SPN/189/2004 Ver.3.0 or latest consisting, the following parts: a) 2 conductor disconnect terminal block-6 Nos. b) End/intermediate plate suitable for 2 conductor disconnect terminal-1 No. c) Screw less end stop similar to WACO Model No. 249-117-2 Nos. d) Insulated jumper WAGO Model 280-402-5 Nos. e) Din Rail - 0.1 metre per set (in length of 1 metre for every ten set) (Inspection: Consignee). | Set | 200.00 | 703 | 1,40,600 |
| 39 | Supply of Non-Deteriorating type of Fuse Holders and Fuse Links 240V AC/DC as per Specn IRS:S 78- 2006 or latest, IS 13703 (Part 2):1993 knife edge type Fuse of El Fuse Link type (up to 20A) - Fuse holder 20A capacity (Inspection: RDSO). | Numbers | 100.00 | 220 | 22,000 |
| 40 | Supply of Non-Deteriorating type of Fuse Holders and Fuse Links 240V AC/DC as per Specn IRS:S78- 2006 or latest, IS 13703 (Part 2):1993 knife edge type Fuse of El Fuse Link type (up to 20A) - Fuse link 1A/ 2A/6A/10A/16A/20A as specified by Engineer in charge (Inspection: RDSO). | Numbers | 200.00 | 31 | 6,200 |
| 41 | Supply of 60 core Indoor Cable with 0.6mm conductor Diameter as per Specns IS 694: 2010 or latest, IRS:S76-89 Amd.3 or latest (Inspection: RDSO). | Kilometre | 1.00 | 1,91,009 | 1,91,009 |
| 42 | Supply of PVC insulated Wire Coils Multi- strand, single core, copper conductor 16/0.2 (16 wires, Diameter of each wire is 0.20mm) (0.5 Sq.mm) wire coil as per Specns IS 694:2010 or latest, IRS:S76-89 Amd.3 or latest. Length of coil should be 100m. Colour of coil to be specified by Engineer in charge (Inspection: RDSO). (Coil) | Numbers | 120.00 | 1,153 | 1,38,360 |
| 43 | Supply of 10 Sq.mm PVC insulated, multi- strand, single core, copper conductor 140/0.3 (140 wires, Diameter of conductor 0.3mm) cable as per IS: 694 or latest, IRS:S76-89 Amd.3 or latest. Cable to be supplied in 100 meter coil (Inspection: RDSO). | Metre | 800.00 | 124 | 99,200 |
| 44 | Supply of PVC insulated Wire Coils Multi- strand, single core, copper conductor 28/0.3 (28 wires, Diameter of each wire 0.30mm) flexible wire coil as per Specns IS 694:2010 or latest, IRS:S76-89 Amd.3 or latest. Length of coil should be 100m. Colour to be specified by Engineer in charge (Inspection: RDSO).(Coil) | Numbers | 10.00 | 2,908 | 29,080 |
| 45 | Supply of Universal Locks with one steel key for every ten locks or part thereof (For example, if locks ordered is 10, 1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19) (Inspection: Consignee). | Numbers | 100.00 | 195 | 19,500 |
| 46 | Supply of Double Walled Corrugated (DWC) HDPE Duct of various Diameter of length of 6m as per Specn RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The Duct shall be supplied along with push-fit type 0-ring coupler or end cap - DWC of outer Diameter 180mm and inner Diameter 153mm (Inspection: Consignee). | Numbers | 60.00 | 3,827 | 2,29,620 |
| 47 | Supply of Basic Material to construct unit Maintenance Free Earth as per Specn RDSO/SPN/ 197 Ver.1.0 or latest consisting of the following:a) Copper bonded steel electrode 3m long, 17mm diameter with copper bonding thickness mini 250 micron and UL listed and marked - 1 No.b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of minimum 10 Kgs - 3 Nos.c) Copper strip with dimensions 150 x 25 x 6mm to terminate earth rod - 1 No.d) Copper strip with dimensions 300x25x6mm Main Equipotential Earth Bus bar (MEEB) - 1 No.e) Copper strip of with dimensions 150 x 25 x 6mm Sub Equlpotential Earth Bus bar (SEEB) - 1 No.f) 35 Sq.mm multi-strand PVC insulated Copper Cable (15 meter) (Inspection: RDSO). | Set | 12.00 | 16,837 | 2,02,044 |
| 48 | Supply of 35 Sq.mm PVC insulated multi- strand, single core, copper conductor 277/0.4 (277 wires, diameter of each wire is 0.4mm) cable as per IS:694 or latest, IRS:S76-89 Amd.3 or latest. Cable to be supplied in 100-meter coil. Colour to be specified by Engineer in charge (Inspection: RDSO). | Metre | 900.00 | 391 | 3,51,900 |
| 49 | Supply of 16 Sq.mm PVC insulated, multi- stand, single core, copper conductor 127/0.4 (127 wires, diameter of each wire is 0.4mm) cable as per IS: 694 or latest, IRS:S76-89 Amd.3 or latest. Cable to be supplied in 100 meter coil. Colour to be specified by Engineer in charge (Inspection: RDSO). | Metre | 400.00 | 178 | 71,200 |
| 50 | Supply of 2-conductor disconnect/test Terminal Blocks (WAGO) or similar with pivoting knife disconnect and test port as per Specn RDSO/SPN/ 189/2004 Ver.3.0 or latest. WAGO Model No. 280-870 or similar (Inspection: Consignee). | Numbers | 1000.00 | 52 | 52,000 |
| 51 | Supply of 3 in 1 Modular Crimping Tool for RJ-45, RJ-11, CAT-5/CAT-6 Ethernet Cable Cutter Crimping Tool IMP Make of Standard, D-Link, i-Ball, Belkin, Tech NXT, Fluke or Terabyte make (Inspection: Consignee). | Numbers | 10.00 | 574 | 5,740 |
| 52 | Supply of Thermo Shrink Jointing Kit for jointing underground 0.9mm Dia conductor 6 Quad cable as per Specn IRS:TC 77-2012 Rev.3 (Amd.1 to Amd.3) or latest (to be procured from approved firm) (Inspection: Consignee). | Numbers | 20.00 | 3,715 | 74,300 |
| 53 | Supply of Permanently lubricated HDPE Duct with outer Diameter of 40mm and inner Diameter of 33mm as per Specn RDSO/SPN/TC/45/2013 Rev 2.0. The length of the duct shall be 1 Km. Two end plugs shall be provided along with the drum (Inspection: Consignee). | Kilometre | 2.00 | 66,223 | 1,32,446 |
| 54 | Supply of Track Feed Battery Charger to work on 110V AC for charging br 2 or 3 or 4 Lead Acid Cell of 80AH (10 Amps) used in Track Circuit as per RDSO Specn No. IRS.S.89/2013 Ver 1.0 latest (Inspection: RDSO). | Numbers | 20.00 | 8,294 | 1,65,880 |
| Schedule total | ₹53,50,029 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022.pdf
ATTACHMENT
GCCcorrectionSlip1to10.pdf
ATTACHMENT
LetterofCredit.pdf
ATTACHMENT
Experience.pdf
ATTACHMENT
Annexure-VIBTurnover.pdf
ATTACHMENT
MakeinindiaPolicy1.pdf
ATTACHMENT
29TD_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .