| 1 | 01₹16.7 LAccepted-AOC H NO 1 7 1 79 1 ROAD NO 7 REDDY ENCLAVE TEMPLE ALWAL SECUNDERABAD 500 010 | HYDERABAD | TELANGANA | 500010 | 01 | Accepted-AOC FOUND LOWEST TENDER WILL BE ACCEPTED IF REASONABLE | |
| 2 | 02₹17.9 L+₹1.3 L (7.63%)Rejected-AOC 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | 02 | Rejected-AOC NOT LOWEST | |
| 3 | 03₹18.1 L+₹1.4 L (8.36%)Rejected-AOC H NO 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500015 | HYDERABAD | TELANGANA | 500015 | 03 | Rejected-AOC NOT LOWEST | |
| 4 | 04₹19.8 L+₹3.1 L (18.7%)Rejected-AOC | 04 | Rejected-AOC NOT LOWEST | |
| 5 | 05₹20.9 L+₹4.2 L (25.3%)Rejected-AOC | 05 | Rejected-AOC NOT LOWEST |
Tender Value
₹25.0 L
EMD Value
₹49,920
Closing Date
14 Jan 2023, 6:00 pmClosed
SHRI MAHAVIR SINGH, IDSE, GE (SOUTH)
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD PIN - 500003
REPAIRS TO TEMP ROOF, FALSE CEILING AND ROOF TREATMENT TO POL AREA, NEW SAFILGUDA ORS, JCOS AND NEW ASSEY LINE UNDER GE SOUTH SECBAD
2022_MES_571225_1
GE(S)/SEC/TOKEN-43 OF 2022-23
Open Tender
Civil Works
Item Wise
240 days
GE SOUTH, MUDFORT, SECUNDERABAD
For Enlisted contractors class E and above category a (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹49,920
Yes
16 Feb 2023
26 Dec 2022
16 Jan 2023
26 Dec 2022
14 Jan 2023
9 Jan 2023
26 Dec 2022 - 6 Jan 2023
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F Hand rails, half round or other steel section nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes notching of wire, etc and similar work conforming to Fe-290 Gde E-165
S&F rolled Mild steel sections as in main and cross beams hip and jack rafters, purlines fixed independentlyof Fe-410W (Gde-250) quality A complete all as specified and as directed.
M&L Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strengh of 550 mpa as on roof covering/ridges fixed with self tapping screws complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc) sheets in roof covering incl ridges complete all as specified and directed.
M&L for 6mm thick AC corrugated sheets in roofs fixed with 'L' or 'J' type in cranked hooks bolts all as specified.
Fixing only for 6mm thick AC corrugated sheets in roofs fixed with 'L' or 'J' type in cranked hooks bolts all as specified.
M&L for asbestos cement two piece separated ridge fixed with "L" type or "J" type in crancke hook bolts for corrugated or semi corrugated sheets complete all as specified and directed.
Fixing only for asbestos cement two piece separated ridge fixed with "L" type or "J" type in crancke hook bolts for corrugated or semi corrugated sheets complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar, or cement line mortar including all quoins, arches pillars etc.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6. complete all as specified.
M&L brick work with sub class B bricks straight or curved on plan to any radious in half brick thick walls built in CM 1:4. complete all as specified and as directed.
Taking down cement plaster from brick or stone walls, ceiling etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick works in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or cement concrete surfaces in cement mortar 1:4, finished fair and even without using extra cement incl mixing of water proofing compound complete all as specified. (Note: Water Proofing compound shall be measured and paid for separately)
M&L for making good of the fallen/broken portion of the RCC Roof/Ceiling with proper reinforcement binding & application of antifungal paint for avoiding rusting of old steel reinforcement complete all as specified and directed.
M&L for applying two coats of oil bound distemper over a coat of primer with wall care putty in two coats including prepartion of new surfaces on walls complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over a coat of primer including prepartion of new surfaces on walls complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying three coats of white washing all as specified.
M&L for applying three coats of white wash on ceiling including perpartion of new plaster surfaces complete all as specified and as directed.
M&L for applying two coats of cement base paint on new plastered surfaces of wall including preparation of surfaces over a coat of priming paint complete all as specified & directed
M&L for applying two coats colour washing on wall surfaces including prepartion of new surfaces complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre pulp insulation etc) or insulation boards / slabs /blankets any thickness, including cover fillets.
M&L for providing false ceiling with anodised aluminium snap grid frame work with size of grid 605 x 605 mm with aluminium main tee size 25 x25 x1.60mm thick and, cross T section of size 25 x 25 x 1.60mm thick and wall angle of size 25x25x2mm thick fixed to roof with rawl plugs/GI wire suspenders complete all as specified and directed.
Providing and fixing Gypsum board 12mm thick in ceiling fixed with screw as per manfacturers instructions and as per specified and directed by Engineer-in-chage.
M & L 4 mm thick Non-Asbestos Cement Plain ceiling boards, fixed to timber/ Aluminium frame work with screws in ceilings and preparing surface, applying two coats of OBD over a coat of primer. complete all as sepcified and directed by Engr-In-Charge.
Demolition of cement concrete of any description and in any position not otherewise specifically provided for as in roof incl tarfelt etc complete all as specified and as directed.
M&L for 40mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in padding (level course) on roof finishing cement concrete surfaces complete all as specified and as directed by Engr-in-charge.
M&L for rendering 10 mm thick in CM (1:3) using water proofing compound as per manufacturer instruction as in roof and chajjas finishingcement concrete surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. Note : Water proofing compound will be measured and paid separately.
M&L for (a)applying a coat of 85/25 bitumen based primer over the plastered surfaces @0.30Ltr/Sqm (b) Providing and laying APP based polymeric membrane of 3mm thickness of weight not less than 3.50kg/sqm on primed surfaces by means of torch application with side overlap of 100 mm both longitudinally and transversely (c) Over APp membrane applying a coat of bitumen primer of 85/25 grade @1.20Ltr/Sqm and over this primer a coat of aluminium paint @0.20Ltr/sqm complete all as specified and directed
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Supply only water proofing compound complete all as specified and as directed.
S & F steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls,(concealed) 15mm bore.including taking down old pipe complete all as specified and as directed.
S & F steel tubing galvanized, medium grade with all fittings, laid in floors or fixed to walls, 20mm bore.including taking down old pipe complete all as specified and as directed.
Demolition and breaking up drain AC pipes/PVC pipe set in cement mortar of any size complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 110mm complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed , in any length with rubber ring joints, fixed to walls bore of the pipe 75mm complete all as specified and as directed.
S&F PVC (SWR) bends 110mm all as specified and as directed.
S&F PVC (SWR) bends 75mm all as specified and as directed.
Cleaning of RCC/PVC water tanks with bleaching powder disconnecting the connection & removing all scales and dirt etc from tanks & from mouth of circulating pipes etc including writing with paint out side tanks " tank cleaned on with month and year " capicity of tanks exc 250 & n exc 500 ltrs and recconneting ,air lock complete all as specified.
Cleaning of RCC/PVC water tanks with bleaching powder disconnecting the connection & removing all scales and dirt etc fromtanks & from mouth of circulating pipes etc including writing with paint out side tanks " tank cleaned on with month and year " capicity of tanks exc 750 & n exc 1000 ltrs and recconneting ,air lock complete all as specified.
S&F in repair rotational moulded polyethylene water storage tanks 500 ltrs(cylindlerical verrtical with closed top) hoisted and fixed in position all as specified in SSR part I including dismantaling of existing damaged water tanks.
S&F in repair rotational moulded polyethylene water storage tanks 1000 ltrs(cylindlerical verrtical with closed top) hoisted and fixed in position all as specified in SSR part I including dismantaling of existing damaged water tanks.
S&F in repair PTMT ball valves 20 mm dia high pressure with epoxy coated aluminium rod and high denscity plastic ball screwed for iron pipes and fixed to iron pipes.
S&F in repairs Gun metal globe or gate valves high pressure with polythene float and fly nut complete screwed for iron pipe or for unions of 20 mm bore and complete all as specified and directed.
M&L for uprooting of wild trees such as grass/ bushes etc., from the roof / wall surfaces /AC sheets/ Soil pipes surroundings including its penetrated roots with suitable cleaning chemical and making good to the damaged plaster by providing CM 1:3 and finish the surfaces to match with the existing surfaces complete all as specified and as directed.
ATUL ENTERPRISES
M/S C MALLIAH & SONS
BEEGEE DESIGN SYSTEMS
VACON INFRASTRUCTURES
S.R.M.K Enterprises
harshraj and co
GUTHIKONDA BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .