| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.1 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹24.9 L+₹1.8 L (7.88%)Rejected-AOC 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L-2 | Rejected-AOC Other than lowest bidder | |
| 3 | L-3₹25.4 L+₹2.3 L (9.98%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-3 | Rejected-AOC Other than lowest bidder | |
| 4 | L-4₹25.8 L+₹2.7 L (11.6%)Rejected-AOC JAMMU PYRAMID CONSTRUCTIONS SAINIK COLONY JAMMU JAMMU 29 SECTOR SAINIK COLONY JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-4 | Rejected-AOC Other than lowest bidder | |
| 5 | L-5₹25.9 L+₹2.8 L (12.2%)Rejected-AOC | L-5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
2 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL RAM G
GE Kaluchak Pin-900673 C/O 56 APO
REPAIRS AND MAINTENANCE OF LT DISTRIBUTION SYSTEM SECURITY STREET LIGHT EM FITTINGS FIXTURES WIRING CIRCUIT BREAKERS ETC AT KALUCHAK MIL STN UNDER GE KALUCHAK
2021_MES_465754_1
GE/KC/NIT-23/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹66,000
Yes
29 Oct 2021
6 Aug 2021
11 Sept 2021
6 Aug 2021
2 Sept 2021
20 Aug 2021
6 Aug 2021 - 18 Aug 2021
90 days
Amount
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 2 above but for one 3/5 pin 5 Amps socket outlet on independent board.
All as per Srl item No. 2 here-in-before but for one 3/5 pin 5 Amps socket outlet on same board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 4.0 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Socket outlet, 5 pin type, 5 Amp, flush type, 240 Volt, complete all as specified & directed.
Bell push flush type, one way 5 Amps single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan, complete all as specified & directed.
Bell, Ding Dong AC. 230 volts, single pole, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
Fully diffused recessed mounted luminaire 2'x2' LED 36W suitable for POP/ gypsum false ceiling complete with hosing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed.
Sub main wiring using uniform coding of wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4.00 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour including taking down old unserviceable sub main wiring, complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Factory made epoxy powder coated distribution board, SPN, 4 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, double door including taking down old unserviceable distribution board, complete all as specified & directed .
Factory made epoxy powder coated distribution board, SPN, 8 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, double door including taking down old unserviceable distribution board, complete all as specified & directed .
Factory made epoxy powder coated distribution board, SPN, 12 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, double door including taking down old unserviceable distribution board, complete all as specified & directed .
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, double pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, double pole, 63 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCB, four pole, 63 Amp, 50 Hz AC supply, 10 KA repturing capacity, 415 Volt, 'C' curve, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way including taking down old unserviceable switch, complete all as specified & directed.
Socket outlet, 5 pin type, 5 Amp, flush type, 240 Volt including taking down old unserviceable switch, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, 240 volt including taking down old unserviceable switch, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal including taking down old unserviceable switch, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including taking down old unserviceable lamp holder, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan including taking down old unserviceable fan regulator, complete all as specified & directed.
Bell push flush type, one way 5 Amps single pole one way including taking down old unserviceable bell push, complete all as specified & directed.
Bell, Ding Dong AC. 230 volts, single pole including taking down old unserviceable bell push, complete all as specified & directed.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including taking down old unserviceable light fitting, complete all as specified & directed.
Fully diffused recessed mounted luminaire 2'x2' LED 36W suitable for POP/ gypsum false ceiling complete with hosing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting including taking down old unserviceable luminaire, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, double pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, double pole, 40 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, double pole, 63 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, four pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 415 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, four pole, 40 Amp, 50 Hz AC supply, 10 KA repturing capacity, 415 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, four pole, 63 Amp, 50 Hz AC supply, 10 KA repturing capacity, 415 Volt, 'C' curve including taking down old unserviceable MCB, complete all as specified & directed.
FRLS PVC insulated unsheathed multistranded copper conductor of 1.5 sqmm (nominal area), 1100 Volts conforming to IS: 694 including taking down old unserviceable conductor, complete all as specified & directed.
FRLS PVC insulated unsheathed multistranded copper conductor of 2.5 sqmm (nominal area), 1100 Volts conforming to IS: 694 including taking down old unserviceable conductor, complete all as specified & directed.
FRLS PVC insulated unsheathed multistranded copper conductor of 4.0sqmm (nominal area), 1100 Volts conforming to IS: 694 including taking down old unserviceable conductor, complete all as specified & directed.
FRLS PVC insulated unsheathed multistranded copper conductor of 6.0 sqmm (nominal area), 1100 Volts conforming to IS: 694 including taking down old unserviceable conductor, complete all as specified & directed.
Plug top, 3 pin, 15 Amps, 240 volts, 50 Hz AC supply including taking down old unserviceable plug top, complete all as specified & directed.
Cutting holes in existing brick/stone walls for making opening for fixing of exhaust fan of 300mm to 450mm sweep including provision of nuts, bolts, washers, MS jali made of 3mm dia MS wire 50mm apreature fixed with and including proper wooden frame at outer surface of walls and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
Supply, hanging and testing of 1200mm sweep, 230 volts, AC ceiling fans, 2 star BEE rated energy efficient ceiling fan conforming to IS:374-2019, having 3 blades alongwith copper wound stator (capacitor start) with minimum air delivery 210 cubic metre per minute, power consumption not more than 50 watt, top speed minimum 370 RPM or higher, speed control by 5 step electronic regulator including capacitor, down rod, canopy, making connection with three core flexiable copper cable of 1.50 Sqmm upto ceiling rose & taking down old unserviceable ceiling fan of any type/size from existing location and depositing in MES store, complete all as specified & directed.
Supply, installation and testing of water heater storage type (Geyser) single phase, 230V, 50Hz, 5 star energy saving, high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000 Watt rated power, incoloy 800 glass coated heating element, tank coating of ferro glass dry powder tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up fixed to walls by drilling of holes, grouting of bolts of suitable size with nuts etc and making good disturbed surface including taking down old unserviceable geyser, complete all as specified & directed.
Tamper proof with inbuilt intelligence electronic energy meter, single phase, two wire direct connected meter with parameter (voltage P-n, PF, frequency current line KW demand, LCD display, optical port class 1.0s), 240 volts 10-60 Amps, complete with meter box single phase with locking arrangements molded in UV stabilised transperant/ flame retardant high grade engineering plastic with unique arrangements for plifer proof interlocking with hinge type box with connection of suitable size wire including seal and sealing wire including taking down old unserviceable energy meter and depositing in MES store yard, complete all as specified & directed. Notes : (i) MES No to be marked on the meter with black paint as directed. All details ie Bldg No, Qtr No, Initial Reading, SL No of new meter etc as per specified format are to be submitted by the contractor.
Dismantling of cross arms of MS channel or angle iron etc. from pole, complete all as specified & directed.
Dismantling of ACSR conductor of any type & size from over head line or LT poles, complete all as specified & directed.
Dismantling of LT insulators of any type, shape & size, complete all as specified & directed.
Taking out old/ unserviceable damaged existing concrete poles of any size/length from existing position after disconnection of electric supply including necessary excavation, demolition of PCC foundation and removing the same from site, complete all as specified & directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Excavation in trenches n.exc 1.5 mtr wide exc 1.5 mtr in deep but not exceeding 3.0 mtr deep and getting out for foundation of poles etc. in any type of soil, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included the cost of excavation.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed.
PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in stay etc including necessary form work, complete all as specified & directed.
PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed.
Steel tubular swaged poles in vertical position swaged type 410-SP-31, 9 Mtr long, ISI marked, in one piece, complete with cast iron base plate, finial taper plug, bolts, nuts washers and screws as required, drilling of holes for continious earth wire as specified duly painted with two coats of aluminium paint over a coat of red oxide primer above ground level including painting throughout internally & below GL (externally) with two coats of bituminous paint, numbering of poles with cut stencil lettering in size 6mm thick, 50mm high and white and black strips of size 30cm width each with synthetic elamel paint upto 1.5m above coping etc, complete all as specified and directed. Note:- 1. Earth work and PCC will be measured and paid for seperately under appropriate items.
Stay Assembly using stay rod of 20mm dia with complete accessories as shown in Electrical Plate No 1 of SSR 2009 Part-I such as loop type insulator, porcelain, vitreous white/ brown or green, large size with overall dimensions 90x140mm clearance of hole 25.5mm, stay wire of size 7/4.00mm, stay plate 300x300x6mm thick, 14mm dia 400mm long GI stay bow, 20mm dia 1.80m long GI stay rod, galvanized thimble, etc. including dismantling of old unserviceable stay assembly, complete all as specified & directed. Note :- Earth work and PCC shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes, testing after completion including disconnecting and taking out old unserviceable cable, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
All as per Srl item No.62 above but cross-sectional area 185 Sqmm 3.5 core.
All as per Srl item No.62 here-in-before but cross-sectional area 150 Sqmm 3.5 core.
All as per Srl item No.62 here-in-before but cross-sectional area 120 Sqmm 3.5 core.
All as per Srl item No.62 here-in-before but cross-sectional area 95 Sqmm 3.5 core.
All as per Srl item No.62 here-in-before but cross-sectional area 70 Sqmm 3.5 core.
All as per Srl item No.62 here-in-before but cross-sectional area 50 Sqmm 3.5 core.
All as per Srl item No.62 here-in-before but cross-sectional area 35 Sqmm 3.5 core.
All as per Srl item No.62 here-in-before but cross-sectional area 25 Sqmm 3.5 core.
All as per Srl item No.62 here-in-before but cross-sectional area 16 Sqmm 4 core.
All as per Srl item No.62 here-in-before but cross-sectional area 16 Sqmm 2 core.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 10 Sqmm twin core cable flat or circular including taking down old unserviceable service connections, complete all as specified & directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 16 Sqmm twin core cable flat or circular including taking down old unserviceable service connections, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Structural steel work as in cross arms, bracings, supports, clamp and back plate fabricated from steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed by Engineer-in-Charge and applying two coats of aluminium paint over one coat of red oxide zinc chrome primer after preparation of surfaces, complete all as specified & directed.
Shackle type insulator porcelain vitreous white, brown or green 75mm high and 90mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31x5mm size, 14mm dia insulator bolts, washers and nuts, complete all as specified & directed.
ACSR conductor of any size drawn straight horizontal on over head lines on existing poles including binding with insulators & 15mm dia PVC separator at equal intervals, weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers etc, complete all as specified & directed.
Re-stretching, restraining ACSR conductor laid over, OH LT line on steel/PCC poles after removing the binding from insulators, lowering the ACSR conductor or broken OH line due to any reason, jointing the broken conductor, Re-binding the ACSR with insulators including providing binding wire, jumpering & connecting the existing service cables after re-stretching/ Re-straining to OH line & removing unavoidable sag in the lines, complete all as specified & directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of LT over head line feeders and removal of the trimmed branches of trees, complete all as specified & directed. Notes : (a). Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. (b). The cutting / trimming of tree branches shall be done to at least 3.00 metre from the outer conductor of OH line. (c). The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Galvanised iron tube 80mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound including taking down old unserviceable tube, complete all as specified and directed.
Galvanised iron tube 50mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound including taking down old unserviceable tube, complete all as specified and directed.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound including taking down old unserviceable tube, complete all as specified and directed.
MCCB of capacity 63 Amps, 4 pole, 415 volt, 50Hz, rupturing capacity 25 KA (minimum) or higher with adjustable thermal and fixed magnetic release, AC, 50 C/S, complete as per OEM design including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 100 Amps, 4 pole, 415 volt, 50Hz, rupturing capacity 25 KA (minimum) or higher with adjustable thermal and fixed magnetic release, AC, 50 C/S, complete as per OEM design including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 125 Amps, 4 pole, 415 volt, 50Hz, rupturing capacity 25 KA (minimum) or higher with adjustable thermal and fixed magnetic release, AC, 50 C/S, complete as per OEM design including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 160 Amps, 4 pole, 415 volt, 50Hz, rupturing capacity 25 KA (minimum) or higher with adjustable thermal and fixed magnetic release, AC, 50 C/S, complete as per OEM design including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 200 Amps, 4 pole, 415 volt, 50Hz, rupturing capacity 25 KA (minimum) or higher with adjustable thermal and fixed magnetic release, AC, 50 C/S, complete as per OEM design including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 250 Amps, 4 pole, 415 volt, 50Hz, rupturing capacity 25 KA (minimum) or higher with adjustable thermal and fixed magnetic release, AC, 50 C/S, complete as per OEM design including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 315 Amps, 4 pole, 415 volt, 50Hz, rupturing capacity 36 KA (minimum) or higher with adjustable thermal and fixed magnetic release, AC, 50 C/S, complete as per OEM design including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 400 Amps, 4 pole, 415 volt, 50Hz, rupturing capacity 36 KA (minimum) or higher with adjustable thermal and fixed magnetic release, AC, 50 C/S, complete as per OEM design including taking down old unserviceable MCCB, complete all as specified & directed.
Detecting the fault of LT 440 volt overhead/ underground system of any feeder/location with necessary safety, testing equipment, tools and plants and rectify the defects on top priority basis/ as and when required including testing on completion, complete all as specified & directed.
Painting to existing steel tubular poles of any length including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.
Repair to LT panel by disconnecting all connections for incomming and outgoing cables and making alternate arrangement for power supply to the unit/Qtrs and repairing to LT panel by providing locking arrangement and hinges for doors through out the length of panel by welding cutting, screws etc all as required at site including spray painting to the entire panel with smoke grey paint in two layers and refixing the incomming and out going cables with rethimbling with provision of new lugs and providing PVC tape in colour code on each wire of cable, complete all as specified & directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Aluminium socket and lugs of appropriate size after disconnecting the cable of any size of 1100 volts grade from panel, de-reeling the loop including cutting out and removing the burnt portion of cable end and relaying the serviceable portion in the existing position / layout including necessary earthwork, chases cutting in PCC work, taking out & relaying bricks and making good the disturbed surfaces and testing, complete all as specified & directed for the following sizes :-
(a) 25 Sqmm
(b) 35 Sqmm
(c) 50 Sqmm
(d) 70 Sqmm
(e) 95 Sqmm
(f) 120 Sqmm
(g) 150 Sqmm
(h) 185 Sqmm
(j) 240 Sqmm
(k) 300 Sqmm
(l) 400 Sqmm
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy 110 lumens per watt including 10 KV surge protection device, mounted on GI bracket, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting from bracket of pole or any other place, complete all as specified & directed.
Intergral LED security light luminaire 90W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy 110 lumens per watt including 10 KV surge protection device, mounted on GI bracket, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting from bracket of pole or any other place, complete all as specified & directed.
Prakash Trading Corporation
kailu construction co
Pyramid constructions
M/S GRD ENGINEERS
Sarbat Construction Co
VEE ESS ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .