Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.0 Cr+₹18.1 L (9.72%)Admitted-Finance | ₹2.0 Cr+₹18.1 L (9.72%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Jas Construction L1 | The Reef Constructions L2 |
|---|---|---|---|---|---|
| 1.00Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : | |||||
| 1.01 | All kinds of soil.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia | 1,750 | metre | 1,500 ₹26,25,000 | 590 ₹10,32,500 Lowest |
| 2.00Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : | |||||
| 2.01 | Above 40 mm nominal bore | 1,550 | metre | 100 ₹1,55,000 | 60 ₹93,000 Lowest |
| 3.00Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : | |||||
| 3.01 | 50 to 80 mm nominal bore | 4 | each | 5,000 ₹20,000 | 3,000 ₹12,000 Lowest |
| 4.00Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : | |||||
| 4.01 | 100 mm diameter pipe | 84 | each | 8,000 ₹6,72,000 | 500 ₹42,000 Lowest |
| 5.00 | Supplying pig lead at site of work. | 224.8 | qunital | 4,000 ₹8,99,200 Lowest | 49,000 ₹1,10,15,200 |
| 6.00Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : | |||||
Tender Value
₹1.8 Cr
EMD Value
₹3.7 L
Closing Date
30 Jan 2023, 3:00 pmClosed
Executive Engineer
Executive Engineer, CD, APWD, Diglipur
Replacement of damaged and rusted main pumping line with new pipes and pipe fittings wherever required from Subashgram pump house to Morich Tikrey under SD-II, CD, APWD, Diglipur
2023_APWD_8820_1
NIT No. 23/SE/CC-I/2022-23/113
Open Tender
Civil Works - Water Works
Works
365 days
Subashgram Pump house to Morich Tikrey, Diglipur
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹3.7 L
Yes
SE, CC-I, Port Blair
30 Jan 2023
6 Jan 2023
30 Jan 2023
6 Jan 2023
30 Jan 2023
16 Jan 2023
6 Jan 2023 - 16 Jan 2023
12 Jan 2023
Amount
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
Above 40 mm nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
50 to 80 mm nominal bore
Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead :
100 mm diameter pipe
Supplying pig lead at site of work.
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :
100 mm diameter Class I
150 mm diameter Class I
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :
100 mm dia
Providing and laying S&S C.I. Standard specials such as tees, bends, collars tapers and caps etc, suitable for flanged jointing as per IS : 1538 :
Up to 300 mm dia
Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost of rubber gasket :
100 mm dia pipes
150 mm dia pipes
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :
100 mm dia Ductile Iron Class K-9 pipes
150 mm dia Ductile Iron Class K-9 pipes
Providing and fixing G.I. Pipes complete with G.I. Fittings including trenching and refilling etc. External work:
100 mm dia nominal bore
Providing and fixing G.I. Union in existing G.I. Pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required:
100 mm nominal bore
Providing and fixing gun metal non-return valve with C.I. Wheel of approved quality (screwed end):
100 mm nominal bore
Providing and fixing G.I. Glanged with specials including testing of joints:
100 mm diameter pipe
The Reef Constructions
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
TenderDocumentNIT23SE.pdf
Tender Documents • 1.54 MB
BOQ_9420.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .