Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC | L1 | Accepted-AOC Admitted | |
| 2 | L2₹44.5 L+₹14,956.90 (0.34%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹44.8 L
EMD Value
₹45,000
Closing Date
31 Jan 2025, 3:00 pmClosed
The Project Director DRDA Krishnagiri
DRDA Krishnagiri
Krishnagiri DT Hosur Block Under National Rurban Mission Scheme PH III 2019-2020 provision Water Supply _ Sanitary and Electrification Arrangements for indoor stadium and Drainage_ Window Glass arrangements for centerlized kitchen building TN04KRI75
2025_RDTN_520858_1
RocNo_10503_2015_R4_10_01_2025
Open Tender
Civil Works - Others
Item Rate
90 days
Hosur
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹45,000
DRDA Krishnagiri
4 Jul 2025
27 Jan 2025
31 Jan 2025
27 Jan 2025
31 Jan 2025
27 Jan 2025
29 Jan 2025
Amount
1.Provision of Water supply and Sanitary arrangements and Electrification arrangements to the Proposed for Indoor Stadium in GHSS (Boys) at Bagalur.
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and cleaning and levelling the site etc., complete - Open Earth work Excavation
Plain Cement concrete 1:4:8 (one cement, four sand, eight aggregate) using 40mm gauge hard broken granite stone jelly for foundation including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted, etc., complete c
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation -
Reinforced Cement concrete 1:1.5 :3 (one cement,one and half sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete as directed by departmental officer etc., complete. - Upto Basement
For Foundation and basement
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors as per standard specification.
Brick work in CM 1:3 (one cement & Three sand) using III class Country bricks of size 8 3/4"X41/4"X 2 3/4" including finishing, curing, etc., complete complying with standard specification
Foundation and basement
Plastering with cement mortar 1:3 (One Cement, Five Sand) 12mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications.
Providing the following thickness of Granolithic pattern floor finish with Plain Cement concrete 1 : 2 : 4 mix using 10-12mm ISS HBG metal and the top rubed smooth etc., complete complying with standard specification as directed. i. 25mm thick for Resid
Supplying and fixing of CI Manhole Cover slab etc., complete
Supplying and fixing of PVC Moulded Steps etc., complete
Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (CPVC-SDR-11 Pipes conforming to IS 15778 having thermal stability cold water with brass and CPVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, Tee with clamps @1.00 meters spacing, with jointing of pipes with one step CPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles taxes, levies VAT etc all complete as per as per specifications, Concealed work including chase cutting)complete complying with standard specification and as directed by the Departmental Officer.
32 mm CPVC pipe
25 mm CPVC pipe
32 mm CPVC elbow
32 mm CPVC ball valve
32 mm CPVC Tee
25 mm CPVC elbow
25 mm CPVC tee
Supply and delivery of 1000 lit capacity and fixing of HDPE tank as per IS 12701/1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complete as per standard specification.
Upto 150M Below GL
From 151M to 180M
From 181M to 210M
From 211M to 240M
From 241M to 270M
From 271M to 300M
Supply of 160 mm PVC casing pipe of best approved qualityetc complete as directed by the departmental officers. The pipe should got approved by the Executive Engineer before use on works
Supply of 160 mm End Cap of best approved qualityetc complete as directed by the departmental officers. The pipe should got approved by the Executive Engineer before use on workson. ( Schedule of rate 2016-17, Item no: 159 C (d))
Supplying and fixing 3 Phase, 5 HP Submergible Mortar of approved make and quality with ISI mark with necessary accssories and fixed with delivery pipe errected in the borewell with necessary clamp etc., with following necessary accessories.
Supplying & Fixing of 1.00 HP sub mergible Motor all accessories etc., complete complying with standard specification
Supplying of 2.5 sqm 3core submersible cable etc complete complying with standard specifications
Supplying and fixing of wall mounting of Panel board with following accessories etc.,
Supplying of best and approved quality of HDPE pipe of the following size including laying in the bore well and tying with copper wire it etc commplete complying with standard specification
40mm dia HDPE pipe
Supplying and fixing of 63mm dia 4Ksc PVC pipe for Water line including laying charges
Supplying and fixing of M.S Grill gate for doowrs, window and Ventilator etc., compete
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 4 points / Coil) Lower End (SD-222)
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End (SD-226)
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Light point / fan point (for electronic regulator) ( 6 points / Coil) Lower End (SD-230)
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A 2 way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for Open MS conduit Staircase Light point Lower End [SD-240]
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End . . [SD-377]
Supply and fixing of 2 nos.6/16A two module socket , 2 nos. 16A one module switch on suitable module surface mounting Box ( GI ) with module cover plate (plastic) on wall with connections. Lower End [SD-406]
Supply and fixing of 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End (SD-387)
Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) . [SD-144]
Supply and fixing of 300mm SL bracket with fancy glass shade and 7W / 9W LED bulb. [SD-81]
Supply and fixing of single box type 4'18W of single box type LED tube Light fitting complete with TW round blocks on wall or ceiling with PVC unsheathed Copper leads from terminals to the fitting. (Make: Phillips/ Havells or Equivalent) (DATA - 1)
Supply and fixing of Square model type fitting Recess Mounted direct-indirect lighting luminaries with special seamlessly integrated frame and side mounted high efficiency low glare 1X400 W LED in CRCA housing with fullsquea type fitting] fitting. (Philips//Luker model Aqua surface fitting [LFLSL 400 W Luker make]with suitable wiring complete with connection. [DATA-2]
Supply and fixing of Square model type fitting Recess Mounted direct-indirect lighting luminaries with special seamlessly integrated frame and side mounted high efficiency low glare 2x2 24W LED in CRCA housing with fullsquea type fitting] fitting. (Philips model FBS 2X2 Aqua surface fitting[LT SAQ-36-C-24W orient make] with louvers cover complete with connection. [SD-439]
Supply and fixing of 4'20W LED Twin box type fluorescent fitting (Philips/ Crompton/ Wipro/orient) complete with Electronic ballast and condensor with TW round block on wall or ceiling with LED tube and PVC unsheathed copper leads from the terminals to the fittings with LWD Tubes. [DATA-3A ]
supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm] [SD-458]
Supply and fixing of AC/DC 76MM Buzzer /call bell suitable for 230volts 50c/s single phase AC supply on suitable TW board with push switch. [SD-105]
supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting. (SD -448)
Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End (SD -530).
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End [SD-507]
Supply and run of 2 of 1.5 sq mm (22 /0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour. [SD 55]
Supply and run of 2 of 2.5sqmm (36/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour. [SD-337]
Supply and run of 2 of 4sqmm (56/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour. [SD-351]
Supply and run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour . [SD-60]
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 6 sq.mm copper wire with painting of suitable colour. [DATA-62]
Supply and laying of 3 1/2 x 120 sq mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Laner of sand and covering the cable completely with bricks and sand and refilling the earth to make good (SD -187)
Supply and clamping of 3 ½ x 120 sqmm PVC LTUG armoured LTUG cable on post or on wall with MS clamps.(SD-205)
Supply and fixing of brass cable gland for 3 1/2 x 120 sqmm PVC armoured LTUG cable with earth connection .(SD 169)
Supply and providing cable end termination of 3 ½ x 120 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. (SD 218)
Supply and fixing of 32A TPN metal clad switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing . ( SD-147)
Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete. (SD-134]
Supply and fixing of 3 phase 500A aerial fuse units for 3 nos 300A fuse units [500V] on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps. [MR]
Supply and run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe concealed in wall ceiling and making good of the concealed portion with connection.[SD- 371]
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry. [SD-211]
Provision TNEB Charge
Provision for Name Board
Provision for Photo Charge
02. Providing Drainage and Window Glass arrangements to the centerlized kitchen and accomadation building at Bagalur H/O Bagalur
Dismantling Plain cement concrete
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and cleaning and levelling the site etc.,complete
Refilling in foundation and basement with excavated earth in layer of not more than 15cm thick
Cement Concrete 1:4:8 (One Cement, Four M.Sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification
Cement Concrete 1:1-1/2:3 (One Cement, One and a half crushed stone M.Sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three M.Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers
Supplying and fixing of non pressure RCC spun pipe of NP4 class including conveyance etc., complete
Jointing RCC pipe with cement with necessay Coller
RCC pipe laying labour charges including all costs
Provisions for supply and fixing of precast RCC Ring including cost and conveyance of materials and all labour charges
Provisions for supply and fixing of precast RCC cover slab including cost and conveyance of materials and all labour charges
Supplying fabricating and fixing in position 2/3rd plain glass 5.50mm thick 1/3rd MDF Shutter With Alu.glass, arrangements
Provision for Name Board
Provision for Photo charges
GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column "BB" for all works in this package} (Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD)
Karpaga Vinayagar Engineer Construction (BID ID -1240253)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .