Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 CrAccepted-AOC BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹8.2 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹8.7 Cr+₹52.7 L (6.41%)Rejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹8.7 Cr+₹52.7 L (6.41%) | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹8.9 Cr+₹65.0 L (7.90%)Rejected-Finance THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹8.9 Cr+₹65.0 L (7.90%) | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹9.1 Cr+₹83.1 L (10.1%)Rejected-Finance | ₹9.1 Cr+₹83.1 L (10.1%) | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹9.2 Cr+₹92.9 L (11.3%)Rejected-Finance 184 MAIN STREET NASIRABAD AJMER RAJASTHAN 305601 | ₹9.2 Cr+₹92.9 L (11.3%) | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹9.6 Cr
EMD Value
₹8.1 L
Closing Date
17 Jul 2023, 6:00 pmClosed
CHIEF ENGINEER CG GOA
HQ CE CG GOA, CHICOLNA BOGMALO 403806
PROVISION OF CGRPT (KOCHI) AT WILLINGDON ISLAND, KOCHI
2023_MES_593323_2
83015/E8
Open Tender
Civil Works
Lump-sum
540 days
GE (I) CG KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE I CG KOCHI
₹8.1 L
Yes
4 Aug 2023
16 Jun 2023
19 Jul 2023
16 Jun 2023
17 Jul 2023
1 Jul 2023
Amount
SCHEDULE ‘A’ PART-I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( EXCAVATION AND EARTH WORK /SITE CLEARANCE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/ PATH/ HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (COMPOUND WALL & GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (ARBORICULTURE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (LAN/ TELEPHONE/TV CONDUIT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (AIR CONDITIONING/ COOLING APPLIANCE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XV (DG SET) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XVI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
PILE FOUNDATION Boring Cast in situ DMC pile of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials outside MD land complete all specified and directed and shown in drawings. Note:- (i) The rate shall include mobilisation, erection, dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii) This item will be executed as per location marked in drg.
Boring Cast in situ DMC pile of 600mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials outside MD land complete all specified and directed and shown in drawings. Note:- (i) The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment separately. (ii) This item will be executed as per location marked in drg.
Reinforced cement concrete of grade RMC M-30 design mix as per IS – 456 with using 20mm graded stone aggregate in cast in situ bored pile of any length/any sections complete all as specified and as shown on drg as in bored pile including non destructive integrity test on all pile as per IS-14893,2001 part-IV. (Note: The unit rate quoted under this item is deemed to be inclusive of charges for non destructive integrity test)
RCC grade RMC M30 design mix as per IS–456 using 20mm graded stone aggregate in pile caps , grade beams etc complete all as specified and shown on drg. Notes for Sl item Nos 16.01,16.02 & 16.03 :- Reinforcement shall be measured and paid for separately under relevant items of this Schedule.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
All as per item No 16.05 here-in-before but for pile caps complete all as specified and directed.
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5 mm dia end over up to and including 10mm dia conforming to IS-1786 as in Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS annealed wire or welding complete all as specified, directed and as shown in drawings.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate for concrete layer below pile caps and foundation complete all as specfified and as shown in drawing.
Formwork to sides of concrete foundation, pile caps , grade beams etc rough finished surface of concrete flat. All as specified and as directed.
Excavating over areas, n exc1.5 m deep and getting out for In Soft/loose soil for pile cap.
Excavating over areas, exc 1.5 m deep and getting out in soil for foundation in soft/loose soil for pile cap beam.
Returning/filling in layers and ramming in layers around pile cap,plinth beam etc using excavated soil incl sprading,levelling,well ramming in layers not less than 25cm thick complete all as specified and as directed.
Removing excavated material exc 1.5Km n.exc 5Km and depositing where directed at a level n.exc 1.5m above starting point.
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 500 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. (Note :- Providing and installing test piles shall measured and paid separately)
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. (Note :- Providing and installing test piles shall measured and paid separately)
M&L for carrying out Initial (lateral load test) cast in situ piles of 500 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M&L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M&L for carrying out Initial load test ( pull out test) of cast in situ piles of 500 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M&L for carrying out Initial load test ( pull out test) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately)
M & L for carrying out Routine load test (Vertical load , Lateral load & Pull out load test) cast in situ Under Reamed piles of 500 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M & L for carrying out Routine load test (Vertical load , Lateral load & Pull out load test) cast in situ Under Reamed piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 500 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
INTERNAL WATER SUPPLY: Supply and fixing 15mm Health faucet with wall hook Make: Hindware Model No F160027 or equivalent complete all as specified & directed.
Supply & fixing 15 mm dia 2 way bib Tap ( Fancy type) cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron/ CPVC pipes complete all as specified & directed.
Supply & fixing wall mixer Jaguar make (CQT-CHR-23273G) equivalent with provision for over head shower with 115 mm long bend pipe on upper side, connecting legs, wall flenges complete all as specified 15 mm dia
INTERNAL ELECTRIC SUPPLY S & F BEE 3 star rated energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed.
S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S&F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed.Make: Crompton Cat-Part No.TRANS AIR 12" or equivalent model of Usha, Havells or BAJAJ
S & F Vertical triple pole & neutral (VTPN), double door, 12-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP MCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY: S & F LT Control panel board, Outdoor type,double door, cubical type, pedestal mounted, of suitable size, CPRI approved having, IP 55, independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar of 600 Amp rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and out going accessories all as approved and comprising as under : Main LT Panel The LT Panel comprising of the following:- Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 400 Amps for Neutral.
Incoming:-Incommer :- MCCB 4 pole 400 Amp, 36 KA, 415 volt- 01 No. Ics =100% Icu Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CT's - 400/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, breaking capacity 36 KA- 02 No. Ics =100% Icu (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu (c) MCB, SPN, 220 Volts, 63 Amps, breaking capacity 10 KA, C Curve - 01 No. Ics =100% Icu Make of MCCB:- Havells/L&T/Indo Asian/ equivalent. (d) Street light timer for automatic operation of street lights Make Havells Cat Part No. DHTBW01006 or equivalent (e) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA 50x50x6 mm thick angle iron duly painted-01 No
Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimum size 255 x 355 x 122 including suitable Cable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, complete all as specified and directed.
S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length 1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and sub main wiring using of FRLS insulated sheathed, multistranded copper conductor 2 runs of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn through the poles for connection from junction box to light fitting complete etc all as specified. Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length.
M & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6" dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 typr D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground incl necessary earth work complete all as specified and directed.
AIR CONDITIONINING/ COOLING APPLIANCES: Supply and fixing, testing and commissioning water cooler with inbuild purifier HIMA 7 NHC, dispensing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. Make: Samsung/Haier/Godrej/Voltas/Equivalent.
Supply and fix refrigerator, electric driven (single phase), 220 V, 50 HZ, capacity 190 Litres, single door complete all as specified and directed. Make:- Samsung/Haier/Godrej/Voltas/Equivalent.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Make: V Guard/ Shakti/Equivalent.
DG SET: Supply and installation, test and commissioning of acoustic proof AMF Panel type diesel engine driven generating set fully wired 415 Volts +5% AC three phase 4 wire 50Hz having capacity 100 KVA continuous rating, Power factor 0.8 (lagging) 415 Volts , 3phase, 4 wire 50 cycles per seconds diesel engine meet stringent exhaust emission tests as per MOEF norms without sacrificing fuel efficiency at normal operating loads directly coupled complete with self- starting system including all accessories , equipment, control panel etc as under as per BS/B 5514/10002, with fuel tank, battery & standard accessories, tools and spares as provided by manufacturer with the following accessories all as specified and as directed:
(a) Diesel Engine : Diesel Engine shall be water cooled and electric start suitable to drive above alternator independently, coupled directly through flexible coupling, six cylinder four stroke, cold starting , 1500 RPM industrial type asm per BS-5514 or IS- 3046 with electronic governor for A-1 governing suitable to regulate speed of DG Set from no load to full load complete with fuel tank of a capacity as per manufacturers recommendations. Fuel lines, stainless steel exhaust flexible coupling and residential silencer mufflers etc shall be provided for continuous operation and standard accessories, sump pre- heaters, turbo charger, lubricating oil pump ( Gear type), lubricating oil cooler, starter, 24 DC, corrosion resistant, scale inhibitor, lubricating oil filters (mounted), fuel filter (mounted), Air cleaner heavy duty dry type with restriction indicator, flywheel housing and flywheel to suit single bearing alternator, Fuel injection pump, Radiator fan (Blower type) with Guard and water pump engine mounted etc. The make shall be CUMMINS/ KIRLOSKJER/ ASHOK LEYLAND/ GREAVES COTTON LTD. (b) Alternator : Alternator shall be 80KW output at 0.80 PF AC 3 phase, 4 wire, 415 Volts, 50cycles, 1500RPM, brush less, self excited, self regulated, screen protected drip proof type with two end shield ball/ roller bearing with damper winding in each pole faces. Alternator shall hace Class 'H' insulation with IP -23 protection. The automatic voltage regulation +/- 1.5% as per IS- 4722 or BS 2613-1970 screen protected drip proof enclosure, self ventilated. The make shall be CUMMINS/ KIRLOSKER/ ALSTOM STMAMFORD/ JYOTI/ CROMPTON.
(c) Generator Set Controller :Microprocessor based gen set controller shall be provided for metering , monitoring, protecting and electronic governing of the engine with LED display for engine water temperature, lubrication oil pressure, Engine protection for low lube oil pressure, high coolant temperature (alarm and shutdown). The system shall include Alternator protection parameters like under voltage, over voltage, over frequency, over current, under frequency (alarm and shutdown), F Relay drivers for remote annunciations, Cyclic cranking, Auto/ manual start, sop, Remote monitoring capability through separate interface modules, engine RPM, engine shutdown display, total hours run and suitable for protection against high water temperature, low lubrication oil pressure, over speed and battery charger failure. (d) Control Panel :The Control panel IP 53 non metallic enclosure with aluminium bus bar, bottom entry and exit of cable, current transformer, set of control fuses, multifunctional meter, indicating lamps for "DGH On" and "Load On" with LED display suitable to display time and date, volts, frequency, current, KW,KWH,PF, RPM and having RS 485 communication port complete with appropriate CTs and control wiring. Factory made floor mounted, totally enclosed, epoxy powder coated suitable for 100KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection MCB for panel instruments duly wired within flexible copper conductor cable sand cable connection with lugs/ thimbles complete as per latest IS/BS and all as specified and directed.
NOTES: (i) Material such as diesel ,oil, water load for testing, instrument required and labour engaged for testing the DG Set for the entire satisfaction of testing officers shall be deemed to be included in the above quoted rate. (ii) Testing of DG Set shall be carried out in presence of authorised representative of manufacturer alongwith Engineer in Charge, Testing Officer nominated by competent authority. The DG set to be installed with RECD ( Retrofit Emission Control Device) as per latest CPCB Norms suitable for DG set of capacity 100KVA complete all as directed.
Supply and fix ON-Load change over switch 415 Volt in sheet metal enclosure 4 pole of capacity 160 Amp complete all as specified and directed.
EXTERNAL WATER SUPPLY: M & L Valve chamber of internal size 0.90 X 0.90 X 0.90 mtr (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10 mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified.
A2Z ENGINEERS AND PILE FOUNDATIONS
SHAIJAL T M
Kanika Construction Company
Agarwal Jagdish Construction Company Pvt. Ltd.
Kurian And Varghese
Mecone Construction Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .