| 1 | L1₹8.2 LAccepted-AOC 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹10.2 L+₹2.0 L (24.0%)Rejected-AOC | L2 | Rejected-AOC Other than the lowest bidder | |
| 3 | L3₹10.9 L+₹2.6 L (31.8%)Rejected-AOC 546 14 JUTOGH CANTT SHIMLA HP 171008 | SHIMLA | HIMACHAL PRADESH | 171008 | L3 | Rejected-AOC Other than the lowest bidder | |
| 4 | L4₹12.5 L+₹4.3 L (51.5%)Rejected-AOC | L4 | Rejected-AOC Other than the lowest bidder | |
| 5 | L5₹12.8 L+₹4.5 L (55.0%)Rejected-AOC 217 ARHAT BAZAR KASAULI DISTT SOLAN HP 173204 | SOLAN | HIMACHAL PRADESH | 173204 | L5 | Rejected-AOC Other than the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹28,840
Closing Date
3 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE JUTOGH
GE JUTOGH, JUTOGH CANTT SHIMLA (HP) 171008
PROVN OF EXTERNAL ELECTRIC SUPPLY ALONGWITH CONNECTED ITEMS FOR SRI BUILDINGS AT JUTOGH CANTT UNDER GE JUTOGH
2020_MES_393467_1
GE/JUT-53 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
JUTOGH
CLASS E CATEGORY b (i)
7 documents required · 7 mandatory
₹500
GE JUTOGH
₹28,840
Yes
16 Dec 2020
7 Nov 2020
5 Dec 2020
7 Nov 2020
3 Dec 2020
20 Nov 2020
60 days
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays and trench etc complete all as specified and directed.
Supply, laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 185 sqmm 3.5 core laid in trenches/ on poles/ road crossing or passing through pipe under road crossing, clamping on wall etc. Note: (i) Earth work, DWC pipe, removing, returning filling will be paid separately. (ii) Cost of laying electrical cable through pipe under road, buildings, tracks, are incl in the quoted rates. (iii) All equipments , machinery, Aluminium lugs/thimbles or tools as per site requirement for laying and connecting electrical cable are provided by the contractor without any extra cost complete all as specified and directed.
Supply, laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 50 sqmm 3.5 core laid in trenches/ on poles/ road crossing or passing through pipe under road crossing, clamping on wall etc. Note: (i) Earth work, DWC pipe, removing, returning filling will be paid separately. (ii) Cost of laying electrical cable through pipe under road, buildings, tracks, are incl in the quoted rates. (iii) All equipments , machinery, Aluminium lugs/thimbles or tools as per site requirement for laying and connecting electrical cable are provided by the contractor without any extra cost complete all as specified and directed.
Supply, fixing or laying HDPE (DWC) tubing 100 mm dia of pressure rating 6Kgf/Cm2 fixing on poles, walls under floors, laying on surface etc as reqd at site complete all as specified and directed. Note: All items and accessories , bend, joints, nut bolts, clamps for wall fixing as per site requirement etc are incl in quoted rates.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and directed.
Removal of excavated material to a distance n exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and directed.
M&L for earthing complete with galvanized steel earth electrode plate of size 60x60x6.3 mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less than 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to GI earth lead strip of size 25x4.0 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing complete all as specified and directed. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh, protection pipe , watering pipe are incl in quoted rate .
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6.3 mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0mm dia at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe for protection of earth lead wire incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing all as directed by Engr-In-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh, protection pipe , watering pipe are incl in quoted rate .
Supply , Fixing & laying GI tubing light grade 100 mm dia for road crossing along with pole/culvert /drainage for mechanical protection of cable complete all as directed. Note: All items and accessories , bend, joints, nut bolts, clamps etc are incl in quoted rates complete all as specified and directed.
S&F busbar chamber of size 1.00 x 1.00 x 0.60 mtr with set of 04 Nos aluminium busbar 400 Amps rating with indication lamp (R-Y-B), supported with angle iron of size 40X40X5 mm, each of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chamber shall be fixed 60 cm above the normal ground level complete with PCC 1:2:4, type B-2, as in foundation complete all as specified and directed . Note : Rate for PCC foundation, earth work and angle iron frame deemed to be included in the quoted rates.
Supply and fixing of on load changeover switches 4 pole 400 Amps , 415 volts in sheet metal enclosure fixing on wall / Poles / LT Panel / Bus bar chamber complete all as specified and directed.
Supply, installation, testing and commissioning outdoor type cubical LT panel board of size not less than 1.0 m x 1.0 m x 0.6 m with outer shell made out of 3.15 mm and inner shell made out of 2.0 mm thick MS sheet and MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1 platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system (each door hinged with body at 4 places) lockable, openable by keys, having pad lock arrangement with both side, with pad lock of three keys 2 nos. olouvers and air vent, gasket ‘u’ type for natural flow of air, completed dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factor fabricated ( Factory approved from CPRI) having modern fabrication followed by powder coated painting having thickness not less than 100 microns TPN aluminum bus bar 600 Amps insulated with colour coded heat shrinkable and shall be mounted on suitable size ‘F’ class insulators, marking connection with aluminum strip conductor of and general construction to IS-8623 of 1993 comprising of the following:-
MCCB 315 Amps, 36 KA 4 pole 415 Volts AC, Ics=100% Icu , adjustable overload setting Ir = (0.8 to 1.0) x In (incoming)-01
MCCB 250 Amps, 25 KA 4 pole 415 Volts AC, overload adjustable Ir = (0.8 to 1.0) x In (Outgoing) -01 Nos
RYB indication LED type, 22.5mm dia, 230 volts protected with MCB SP 2 Amp showing 3 phase supply -03 Nos
Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves etc complete
Note (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, PCC, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.
Supply, installation, testing and commissioning outdoor type cubical LT panel board of size not less than 1.5 m x 1.2 m x 0.8 m with outer shell made out of 3.15 mm and inner shell made out of 2.0 mm thick MS sheet and MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1 platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system (each door hinged with body at 4 places) lockable, openable by keys, having pad lock arrangement with both side, with pad lock of three keys 2 nos. olouvers and air vent, gasket ‘u’ type for natural flow of air, completed dust & vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz factor fabricated ( Factory approved from CPRI) having modern fabrication followed by powder coated painting having thickness not less than 100 microns TPN aluminum bus bar 600 Amps insulated with colour coded heat shrinkable and shall be mounted on suitable size ‘F’ class insulators, marking connection with aluminum strip conductor of and general construction to IS-8623 of 1993 comprising of the following:-
Onload change over switch 400 Amps 4 Pole - 01
MCCB 250 Amps, 25 KA 4 pole 415 Volts AC, Ics=100% Icu adjustable overload setting Ir = (0.8 to 1.0) x In (incoming)-01 Nos
MCCB 100 Amps, 16 KA 4 pole 415 Volts AC, overload adjustable Ir = (0.8 to 1.0) x In (Outgoing) -06 Nos.
RYB indication LED type, 22.5mm dia, 230 volts protected with MCB SP 2 Amp showing 3 phase supply -03 Nos
Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves etc complete
Note (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, PCC , provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) or road cutting complete all as specified and as directed.
M&L for PCC 1:2:4, type B-1, using 20 mm graded crushed stone aggregate as in filling demolished surface or as leveling course or in foundation or under tiles or in any required work and make surface clear complete all as specified and directed.
KATWAL TECHNOCRATS
M/S kuldeep kumar khullar
Vinod Kumar Aggarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .