Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | L1 | Accepted-AOC M S Shree Mahavir Associates Index E 101 CE N Vskp Being the lowest tenderer and rates are reasonable | |
| 2 | L2₹12.1 L+₹51,752 (4.45%)Rejected-Finance AT BRAJARAJPUR PO INS CHILKA DISTT KHURDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Being other than the Lowest tenderer | |
| 3 | L3₹14.2 L+₹2.5 L (21.8%)Rejected-Finance | L3 | Rejected-Finance Being other than the Lowest tenderer | |
| 4 | Rejected-Technical NEAR SOLAPOKHARI PO INS CHILKA DIST KHURDA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | - | Rejected-Technical No in WLR CECC Luknow |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
31 May 2021, 6:00 pmClosed
Commander Works Engineer 2 Visakhapatnam
Commander Works Engineer 2 ,Chief Engineer Navy Visakhapatnam Complex, Station Road, Visakhapatnam, 530004
REPAIRS REPLACEMENT OF SPARE PARTS AND PERIODICAL MAINTENANCE OF 3 x 21 TR CENTRAL AC PLANT AT INHS NIVARINI AND 2 x 45 CENTRAL AC PLANT AT APSARA AT INS CHILKA
2021_MES_438411_1
82521
Open Tender
Miscellaneous Works
Item Rate
120 days
GE Chilka
Class E cat c i
6 documents required · 6 mandatory
₹500
Yes
GE Chilka
₹24,000
Yes
1 Jul 2021
26 Apr 2021
4 Jun 2021
26 Apr 2021
31 May 2021
10 May 2021
26 Apr 2021 - 28 Apr 2021
Amount
M & L for descaling of the condensers tubes and other tubes of 2 x 45 TR capacity Central AC Plant capacity by suitable chemical reagent (HCL & others as approved) by pressure feed method by pump after disconnecting condenser water lines, and opening the end covers of both side, disconnecting electrical supply, brushing with suitable size of wire brush removing the scales and maintaining proper internal diameter and refixing all dismantled parts including replacement of 3mm thick rubber gasket set as per existing pattern complete all as specified and as directed. Note:- (i) Supply only spare parts shall be measured and paid separately under relevant Item. (ii) Cost of fixing of spare parts,lubricants,T&P and minor spares,bolts,nuts,etc shall deemed to be included the unit rate quoted.
M&L for descaling of the condensers tubes and other tubes of 3 x 21 TR capacity Central AC Plant capacity by suitable chemical re agent (HCL & others as approved) by pressure feed method by pump after disconnecting condenser water lines, and opening the end covers of both side, disconnecting electrical supply, brushing with suitable size of wire brush removing the scales and maintaining proper internal diameter and refixing all dismantled parts including replacement of 3mm thick rubber gasket set as per existing pattern complete all as specified and as directed. Note:- (i) Supply only spare parts shall be measured and paid separately under relevant Item. (ii) Cost of fixing of spare parts,lubricants,T&P and minor spares,bolts,nuts,etc shall deemed to be included the unit rate quoted.
M&L for pumping down the gas of the Central AC plant of various capacities pressure testing the complete plant by dry nitrogen gas by separating high side and low side, rectifying and sealing the the leakage by gas welding/ brazing pressure, completely vaccuming the system and re-charging the system with R-133a or R-407 gas or as mentioned in the AC plant system, testing and commissioning complete all as specified and as directed. Note: Gas will be measured and paid separately under relevant Item.
S&F in replacement of 11 Ton Voltas HVAC compressor scroll type, Model No SZ185S4RC, 415V,50 Hz, for R-407C, R-134a, R-507 gas , sealed compressor for central AC plant capacity 3x21 TR at INHS Nivarini hermetically sealed type with overload protector as per existing sample complete all as directed by Eng-in-charege.
Supply only pressure gauge of HP/LP/OP of size 4" dia of rating 0-16 Kg/sqcm or 0 - 300 PSI (lb/sq inches) complete all as specified and directed. Make :- Feibig / H-Guru
Supply only temperature guage size 4 inch dia of rating 0 to 50 degrees complete all as specified and directed. Make:- Allied/ Altod/ Fiebig / Heibig / Scientific
Supply only water pressure cut out valve 1 PS - 70 complete all as specified and directed. Make :- Danfoss / Indfoss
Supply only HP cut out valveType MP - 5 suitable for R - 407 C gas complete all as specified and as directed. Make :- Danfoss / Indfoss.
Supply only LP / HP combination cut out valve MP - 15 Suitable for R - 407 C gas complete all as specified and directed. Make : Danfoss / Indfoss
Supply only oil pressure control switch type MP - 55 suitable for R - 407 C complete all as specified and directed. Make : Danfoss / Indfoss.
Supply only solenoid pilot control valve type 10 with two / three coil assembly of same model complete all as specified and directed. Make :- Rotex / Eqmt
M&L for dismantling Monoblock pump set 7.5 HP capacity (any make) removing scales cleaning, heating varnishing of motor winding , servicing the pump sets by repalcing the worn out bushes, bearings, gland rope, gland bolts & nuts, painting etc reassembling the complete pump set including testing and commissioning complete all as specified and directed.
All as per item No.12 but capacity of Monoblock pump set 1.5/ 5 HP complete all as specified and directed.
Supply and filling refrigerant gas R 407 or as per exisiting Refrigerant of the AC plant at various installation complete all as specified and directed. Make :- FLORN / REFRON / MAFRON. Note :- The gas is to be supplied in sealed cylinder. Empty cylinder will be returned to contractor after consumption of Gas
Supply and filling of compressor oil suitable for DANFOSS Make COMMERICAL to the compressor at various installation after draining the old compressor oil complete all as specified and directed Make : Note :-The compresssor oil to be supplied in sealed cane. Empty cane will be returned to contractor after consumption of Oil.
M&L for repairing fan motor of capacity 1.1 X 2 KW after disconnecting and removing it from its position and getting it repaired by copper winding the motor with copper wires of existing guage and re-fixing the same and re-connecting all the electrical wiring ,testing complete all as specified and directed.
Supply only 63 mm dia gun metal gate valve ,ISI marked with iron wheel head screwed both ends for iron pipe complete all as specified and directed. Make :- Zoloto/ Flowwell / Indco/ Inter valve.
Supply only thermostatic expansion valve of existing make and model MWE -34 -CP 100 complete all as specified and directed. Make:- Danfoss/Honeywell/ Sporlan
Supply only Bimetal thermal over load relay (relay range suitable for MNX12 contactor) including disconnecting & reconnecting inter connections complete all as specified and directed. Make :- L&T/ BCH / Siemens / Legrand.
All as per item No. 19 above but suitable for MNX 22/25 (relay range 12.5 -25.0)complete all as specified and directed. Make :- L&T/ BCH / Siemens / Legrand.
All as per item No. 19 above but suitable for MN32 contactor (relay range 9-15) complete all as specified and directed. Make :- L&T/ BCH / Siemens / Legrand
Supply only electronic Timer (for time delay) suitable for 240V/360V/415VH z suitable for 3-10 seconds from panel board complete all as specified and directed Make : L&T/ BCH / Siemens / Legrand.
Supply only Copper Tube Pipe 1/4 inch suitable for gauge and cutout connection purpose as per existing model complete all as directed.
Supply only Flare nut brass 1/4 inch suitable for gauge and cut out connection purpose as per existing model complete all as specified and directed NOTE :- Rate quoted under this item is inclusive of cutting and flaring of copper pipe as required
Supply only 100 A, 4 pole MCCB, 25 KA including necessary cable lugs & wire etc complete all complete as specified and directed. Make :- Legrand/Siemens/ ABB/ Schneider/ L &T
Supply only 63 A, TP MCCB, 25 KA including necessary cable lugs & wire etc complete all as specified and directed MAKE: Legrand / Seimens /ABB / Schnieder.
Supply only digital type Ammeter 96X96 mm square flush mounted case of class 1.0 complete all as specified and directed. Make : AE / IMP / MECO / MEI / HPL.
Supply only digital type Voltmeter 0-500V, 96X96 mm square Flush mounted case of class 1.0 complete all as specified and directed . Make : AE / IMP / MECO / MEI / HPL
Supply only MCB,TP , 40 Amp,10 KA, 240 V, AC supply, 50 Hz, C-series complete all as specified and directed. Make: Legrand/Seimens/ABB / Schneider
Supply only MCB,SP,10A, 10 KA, 240 V, AC supply, 50 Hz , C-series complete all as specified and directed. Make: Legrand/Seimens/ABB / Schneider
Supply only 3 pole air break power contactor auxiliary MNX9 AC3= 10A, 415 V main supply, 240 V control supply, 50 Hz, for 1.1 x 2 KW fan motor complete as specified and as directed. Make:-Legrand/Seimens/ABB / Schnieder
Supply only 3 pole air break power contactor auxiliary MNX32 AC1 = 56A, AC3=32A, 415 V main supply, 240V control supply, 50 Hz, for 15 KW/20 HP compressor motor complete all as specified and directed. Make:-Legrand/Seimens/ABB / Schneider
Supply only 3 pole air break power contactor auxiliary MNX22 AC1 = 32A, AC3=25A, 415 V main supply, 240V control supply, 50 Hz, for 15 KW/20 HP compressor motor complete all as specified and directed. Make:- Legrand/Seimens/ABB / Schneider
Supply only Water flow Sensor/switch WFS - 0 - 1001 - H Max Pressure 1 Mpa, Max temp - 100 degree complete all as specified and directed. Make :- Honeywell / Dansfoss / Emmerson / Sporlon.
Supply only Therrmal expansion valve for R22 / R407C , 40 degree +/- 10 degree , pressure 46 bar, MWP 667 Psig complete all as specified and directed. Make :- Sporlon / Danfoss / Indfoss / Honeywell
M&L for chilled water Mild steel pipe line insulation by applying adhesive SSR 998 Make: Favicol, adding pre-fabricated glasswool for pipe section 50mm wall thickness to cover 32 to 100 mm mild steel pipe, covered with waterproof PUF insulation material and aluminium cladding 24 guage thickness over the top joined by aluminium rivetting complete all as directed by Eng-in-charge.
M&L for repairing HVAC compressor scroll type Model No SZ185S4RC , 415V, 50 hz,for R407C, R134a, R507 after dismantling from the HVAC system, after extracting the gas completely from the system and storing it for further re-use, securing the liquid line and gass line, transporting to the work shop, and re-instating the same after rectifying the defect , charging the system with refrigerant gas and successful commisioning of the HVAC system complete all as specified and directed
Supply only Display control unit microprocessor based computer control functioning unit, LCD with touch functionality, 415 main voltage, 3 phase, AC supply, calliberating and programming to operate the HVAC system under desired temperature and pressure and providing smooth operation to the system, along with all necessary wiring etc complete all as specified and directed. Make:- Voltas / As per OEM recommendation
S&F V belt B-63 17 x 1600 of required size as per existing sample complete all as specified and directed Make:- As per existing model as directed by GE.
S&F mild steel ,butterfly valve 100 mm dia, ISI marked as per existing sample complete as specified and directed. Make:- Zoloto / RMCO.
S&F 50mm dia gate valve, with iron wheel head, ISI marked as per existing sample complete as specified and directed.
S&F RYB LED indicator bulb , 240 V ,AC supply complete all as specified and directed. Make:- C&S / HPL/ Havells
S&F cast iron Y- strainer 4"/100mm dia along with rubber gasket ISI marked complete all as specified and directed
S&F push button start/ stop type, 240V, AC supply complete all as specified and directed. Make :- C&S/ L&T
S & F in replacement HEPA filter of suitable size (min 1feet x 1 feet) of efficiency 99.97% down to 0.3 microns or higher efficiency all units tested by DOP( Dispersed Oil Paticulate ) / POA ( Poly Alpha Olefin) tests all as per existing sample for hospital operation theatre complete all as specified and directed.
S&F in replacement Medium pressure electric valve actuator CN7510A2001 , non-spring return direct-coupled damper actuator with modulating and floating/2 - position control for AHU vent dampers, supply voltage : 24Vac-15%/+20%, 50/60 Hz, Nominal Voltage : 24 Vac/dc, 50/60Hz, MN7505/7510: 5VA/2W, control signal,. modulating:0)2....10Vdc, Floating/2-position:24 Vac/dc, Ambient operating limits: -5...+140 degree F(20...+60 degreeC), Ambient storage limits : -22....+ 176 F (-30...+80 degree C), Relative humidity : 5-95%, non- condensing, IP54, overvoltage category:II, torque rating : 88lb-in(10 N-m) complete all as specified and directed. Make : Honeywell
M & L for wiring of electric valve actuator in AHUs to air dampers at end points of air duct, calibrating the actuator and motors to perfectly balance and operate the dampers at suitable time interval, with suitable wiring of size not less than 4 sqmm wire complete all as specified and directed.
ANTARYAMI PANDA AND COMPANY
M/S KAMAL KEE ENGINEERS WORK
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .