Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.1 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹30.0 L+₹3.7 L (14.0%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹31.4 L+₹5.0 L (19.1%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹31.9 L+₹5.6 L (21.2%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹33.4 L+₹7.0 L (26.6%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L-5 | Rejected-Finance L-5 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
2 Mar 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/REPLACEMENT OF VALVE PIT CHAMBERS JOINTS, FILTRATION PLANT, REPAIR MAINT OF MES INSTALLATION AND OTHER APPLIANCES ETC AT AF STN CHANDINAGAR IN AOR OF GE (AF) FARIDABAD
2024_MES_640432_1
GE (FBD)/AF-79/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹98,000
Yes
10 Apr 2024
2 Feb 2024
5 Mar 2024
2 Feb 2024
2 Mar 2024
17 Feb 2024
2 Feb 2024 - 9 Feb 2024
Amount
M&L for servicing of Indoor unit & Out door unit of Split type AC of 1.5 tone capacity by taking out the same from existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil rinse solution without damage any part and reinstall at the same location and clean water with water pressure gun, greasing of fan , motor , blower including acid/detergent foam type wash etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 01 but split type AC of 2.0 ton
M&L for servicing of Window type AC of 1.5 tone capacity by taking out the same from existing location , cleaning of condenser , cooling coil and other components with cooling coil rinse solution and clean water with water pressure gun, greasing of fan , motor , brushing cleaning with blower including acid/detergent foam type wash etc without damage any part and reinstall at the same location complete all as specified and directed by Engineer-in-Charge.
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split type AC of 1.5 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the gas R-22 ,R-32, R-410 and testing the AC complete all as specified and directed by Engineer-in-Charge.
All as per item No 04 but split type AC of 2.0 ton
M&L in repair for taking out unserviceable sealed unit (compressor) 1.5 ton capacity , single phase, 230 volt of models as existing and replacing the same with new sealed unit (compressor) including necessary modification of the foundation as required to suit the compressor, vacumacation , pressure , testing, leaking, rectification incl gas charging R-22,R-32 ,R-410 and testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 06 above but 2 TR
M&L for Split type AC outdoor unit (suitable for existing AC) complete only of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge.
M&L for Removing the split type AC 1.5 ton/ 2 ton capacity working on 230 V single phase /440 Volt 3 phase complete including indoor and out door unit all as directed including making good of complete all as specified and directed by Engineer-in-Charge.
M&L for reinstall at any place ( with in the stn ) at height up to 5 mtr from floor level including replacement of refrigerant tubing upto 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for Split AC Indoor unit (suitable for existing AC ) complete of capacity 1.5 TR incl taking down old unsv complete all as specified and directed by Engineer-in-Charge.
M&L for stand ( wall mounted type & Floor mounted type ) of suitable for split type AC incl taking down old unsv complete all as specified and directed by Engineer-in-Charge.
M& L for PVC drain pipe 110mm dia incl taking down old unsv complete all as specified and directed by Engineer-in-Charge.
M&L for providing nitril rubber thermal insulation to copper tubing’s from Indoor to outdoor units with foam pipe insulation ( 1/2" ID X 1/2" thk) followed with clamps complete all as specified and directed by Engineer-in-Charge.
M&L for repair to PCB card of window / Split type AC for remote operation complete testing and installation and all electrical connections including replacement of defective electronic components / IC Circuits complete all as specified and directed by Engineer-in-Charge.
M&L for repair to PCB Card of inverter type split AC for remote operation complete testing and installation and all electrical connections including replacement of defective electronic components / IC Circuits complete all as specified and directed by Engineer-in-Charge.
S&F in replacmemt remote control unit (cordless) as per existing model for AC unit complete all as specified and directed by Engineer-in-Charge.
S & F Air filter suitable for 1.5 ton split type AC as required on site incl testing for satisfactry working condition as directed by Engr-in-Charge
All as per item No18 but split type AC of 2.0 ton
S & F Thermostat suitable of 1.5 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge.
All as per item No 20 but split type AC of 2.0 ton
S & F Single pole contactor for Split type AC 50/60 Hz 240 V complete all as specified and directed by Engineer-in-Charge.
S & F Axilary contactor single phase 220 Volts 10 Amps current capacity complete all as specified and directed by Engineer-in-Charge.
S & F Start Relay suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of old U/S copper condenser coil assembly complete suitable for 1.5 ton split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of old U/S copper condenser coil assembly complete suitable for 2 ton split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of old U/S copper condenser coil assembly complete suitable for window type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of old U/S evaporator coil assembly complete suitable for 1.5 ton Split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of old U/S evaporator coil assembly complete suitable for 2 ton Split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of old U/S evaporator coil assembly complete suitable for Window type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of copper tubing 5/8” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of copper tubing 3/8” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of copper tubing 1/4” outer dia suitable for 1.5/2 TR AC including nitril rubber thermal insulation capacity complete all as specified and directed by Engineer-in-Charge.
S&F in repairs running capacitor of capacity ‘45+5’ MFD, 240 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge.
All as per item No 34 above but capacity 36 MFD
S&F in replacement blower suitable for existing Split AC complete all as specified and directed by Engineer-in-Charge.
S&F in repairs blower fan motor of capacity 1/30 HP, 3 speed, single phase (as per sample ) complete all as specified and directed by Engineer-in-Charge.
S&F in repair condenser fan motor of capacity 1/20 HP, single phase (as per sample) complete all as specified and directed by Engineer-in-Charge.
S&F in repair starting capacitor of capacity 60 MFD, 40 volt, 50 Hz complete all as specified and directed by Engineer-in-Charge.
S&F in repairs starting capacitor of capacity 100-120 MFD , 440 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of DC fan motor of split AC unit with supper enameled copper wire of suitable gauge wire and testing on load for complete all as specified and directed by Engineer-in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of cable 3 core 4 sqmm FRLS PVC copper conductor complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of Refrigerator any size at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location acomplete all as specified and directed by Engineer-in-Charge. Note:- Components reqd to be replaced will be measured and paid separately
Supply only the following parts/components of refrigerator/Deep Freezer of 165/190/315/324/360/388/425 Ltr capacity ccomplete all as specified and directed by Engineer-in-Charge. (a) Box type relay
(b) Thermostat with control knobcomplete
(c) Drier complete
(d) Condenser
(e) Copper capillary Tube
(f) Magnetic door gasket
(g) Chiller tray
(h) Vegetable tray PVC
(j) Aluminium grill rack PVC Coated)
(k) Pigmy lamp 15W with screwed/Bayonet Cap
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of up to capacity 325 Ltr as existing make including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.
All as per item No 55 above but capacity of refrigerator 360 Ltr
M&L for servicing of Deep freezer of size 320/425 Ltr at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 425 Ltr as existing make including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge.
M & L for servicing of Water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil Rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of starting relay as required at site for water coolers complete including connecting, testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of waste water tray as required at site made out of 20 gauge GI sheet complete with PVC drain pipe including painting with PVC drain pipe including painting with aluminum paint complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of brass float valves accessories 15mm size as required at site complete all as specified and directed by Engineer-in-Charge.
M&L for Disconnecting and taking down water cooler of any make and size for repairs including detection of leakage in the system rectifying the same, dehydration & recharging of gas testing the water cooler for smooth & satisfactory working complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of CP push cock ISI marked 15mm base complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of condenser fan motor single phase as required at site for water cooler with clamps, bolts, nuts & rubber bushes complete including connecting testing complete all as specified and directed by Engineer-in-Charge.
M&L for Replacement of wiring kit for water cooler of any make and capacity complete all as specified and directed by Engineer-in-Charge.
M & L for taking out unserviceable sealed unit (compressor) of water cooler 150/150 Ltrs capacity single phase 230 volt of as existing model and replacing the same with new sealed unit (Compressor ) including necessary modification of the foundation as required to suit the compressor, vacumisation presser testing, leakage rectification incl gas charging and testing complete all as specified and directed by Engineer-in-Charge.
All as per item No 67 above but compressor as existing model and replacing the same with new sealed unit (Compressor) for water cooler 80/40 Ltr capacity
M & L for servicing of desert cooler of any capacity at existing location by cleaning of all components with Rinse solution & clean water, greasing of fan, motor including cleaning of water storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of small parts like PVC water distributer, flexible pipe, plugs etc as required on site complete all as specified and directed by Engineer-in-Charge.
M & L for scraping and removing old paint of desert cooler body (steel surfaces) and preparation of steel surfaces including necessary denting, cutting, welding etc for spray painting with approved smoke gray synthetic enameled paint (Ist quality) over a coat of Zinc chromate primer on outer surface and inner surface i.e. Water tank and body fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of Zinc chromate primer complete for desert cooler of any size and capacity complete all as specified and directed by Engineer-in-Charge.
S & F in replacement Desert cooler Pump as per existing capacity complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of cooling fan motor supporting legs and PVC fan blade of 450 mm sweep for desert cooler complete all as specified and directed by Engineer-in-Charge.
M & L for rewinding of desert cooler motor of any make with supper enameled copper wire (Thermal class E) of appropriate size including replacement of gun metal bushed and steel shaft complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of 01 Nos front grill mild steel plain block and 3 side louvers suitable for desert cooler duly spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer as required on site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Desert cooler motor copper wound complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of desert cooler body 660x660x900mm with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge milled steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min3 mtr in length). External surface shall be spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of running cap 4.0 MFD 440 volt complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of wood wool pad 25mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr capacity desert coolers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of rotary switch as requirement at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC water distributer flexible pipe with TEE and all accessories in desert cooler at site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of piano type 05 amp switch 230 volt , AC complete all as specified and directed by Engineer-in-Charge.
S&F in repair cable copper conductor PVC insulated FRLS 2 core 1.5 Sqmm complete all as specified and directed by Engineer-in-Charge.
M&L for servicing, repair of Voltage stabilizer of capacity 4 / 5 KVA cleaning , dusting, brushing, checking and rectify electrical conections, and other components complete all as specified and directed by Engineer-in-Charge.
S&F in repairs time delay relay suitable for 4/5 KVA voltage stabilizer complete all as directed by Engineer-in-Charge
S&F in repirs diode suitable for voltage stabilizer of capacity 4/ 5 KVA complete all as directed by Engineer-in-Charge
S&F in repairs condenser suitable for voltage stabilizer of capacity 4/5 KVA complete all as directed by Engineer-in-Charge
S&F in replacement electronic circuit board with relay suitable for 4/5 KVA voltage stabilizer of any make and testing complete all as directed by Engineer-in-Charge
M&L in repair transformer suitable for voltage stablizer 4/5 KVA as required on site complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of voltage stabilizer of capacity 5 KVA input variation between 170 volts to 250 volts with output voltage stabilized at 230 with accuracy of +-2.5% and capacity 5 KVA complete all as specified and directed by Engineer-in-Charge.
M&L for Exhaust fan motor for 300 mm sweep ( as per suitable for exixting)complete all as specified and directed by Engineer-in-Charge.
S&F wall mounting fan motor for 400 mm sweep complete all as sepecified and directed by Engr -in-Charge.
S&F in replacement of Exhaust fan 10"/12" sweep complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC Exhaust fan 300MM sweep complete all as specified and directed by Engineer-in-Charge.
M&L for servicing,Taking down ceiling fan 56"/48" sweep removing cleaning of dust, properly cleaning greasing of bearing including replacing and painting connecting up complete all as specified and directed by Engineer-in-Charge.
Supply and fixing capacitor, capacity 2.5 mfd in replacement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing capacitor, capacity 3.15 mfd in replacement complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of burnt ceiling fan motor 1200/1400 mm sweep with super enamelled copper winding wire of suitable gauge as per details of any make /model complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of ball bearing of ceiling fan of any size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing and connecting flexible copper twisted twin core of size 23/00076 complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of gun metal bush of any type/make/size complete all as specified and directed by Engineer-in-Charge.
supply and replacement of rubber real complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of U Clamp complete with nuts, bolts, pins. Heavy duty complete all as specified and directed by Engineer-in-Charge.
Supply and fixing nuts,bolts, washers and spilt pins for ceiling fan complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator flush type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge.
S& F AC plug of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC completeall as specified and directed by Engineer-in-Charge.
S& F AC socket of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC completeall as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed by Engineer-in-Charge.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge.
Taking down UNSV LT Under Ground cable of any size complete all as specified and directed by Engineer-in-Charge.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed by Engineer-in-Charge. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per Item No 114 above but for 4 core 16 Sqmm.
All as per Item No 114 above bu but for 3.5 core 25 Sqmm.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer to new/existing steel and iron surfaces over 10cm in width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge.
All as item No 118 above but for cable of size 70 to 120 sq mm.
M&L for Chemical earthing , Design development supply commissioning and testing EHCC certified ground terminal earthing system hollow tube solid bar CCPRI tested for sensitive signal/Electrical equipments highly anti corrosive long life severe wear conditions in the earth pit and of standard size ISI marked copper tube out side secondary conductor of 50mm dia and main primary conductor inside 25mm dia 3000mm length ready to install with suitable connecting terminal confirming to IS:3043 1987 specification highly conducive packing material to be filled in earth pits for providing uniform low resistivity anti corrosive hygroscopic medium around the earth system for improving the efficency of current dissipation 20 Kg per bag (3 bag per kit) min or sufficeient quantities required as per site complete incl PCC pits of inside dimension 0.5x0.5x0.5m and suitable cover complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead/strip upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately.
Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required Copper Strip 20x3 mm complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with copper plate earth electrode 60cmx60cmx3.15mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to copper earth lead strip of size 20X3.0 mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection pipe and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead/strip upto 7.5 mtr, char coal dust, common salt, porcelain insulator,PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, and earth lead exceeding 7.5 mtr are measured and paid separately.
Supply ,and errection in true vertical position steel tubular swaged pole type 410 co SP-31 , 09 mtr long complete with cast iron base plate and final tape plug, bolts, nuts, washers and screws incl painting with synthetic anamelled aluminium paint two coat over one coat of red oxide primer after errection and providing black and white strips with synthetic enamel point 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete and marking pole number on pole ,incl taking down old unsv pole complete all as specified and directed by Engineer-in-Charge. Note: (i) Earth work and PCC shall be measured and paid separately. (ii) Pole no shall be marked on each pole as directed..
Supply and fixing stay assembly complete with all accessories, such as stay plate 230X230X6 mm3, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc. all as per electrical plate No 1 orr SSR part 1 and incl taking down old unsv complete all as specified and directed by Engineer-in-Charge. Note: Earth work and PCC work will be measured and paid separately.
Supply and fixing in replacement of Retro reflective sign board of size 900 mm X 1200 mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on MS frame of with legs of MS angle section 35 mm X 35 mm X 4 mm on PCC 1:3:6 type 750 mm above he ground level and 2.10 m below the ground level. The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on both side of ACP Sheet.The size of letters and description will be board will be complete fixing/grouting with nut/bolts/Anchor fastener with washers complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Retro reflective sign board of size 600mmx1800mm made of ACP sheet of 3 mm thick. ACP Sheet will be fixed on wall , The background of board to be provided with blue colour, letters and border with white retro reflective tape. Same description will be mentioned on one side of ACP Sheet.The size of letters and description will be as per directed by Engr-in-charge, board will be fixed on Wall complete fixing/grouting with nut/bolts/Anchor fastener with washerscomplete all as specified and directed by Engineer-in-Charge.
Repair and replacement of Maintenance free dry battery 12 volt 180 AH minimum warrenty of 36 Months including statndard accessories complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of outdoor type LED flood light 120 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of outdoor type LED flood light 150 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED Street Light Luminaries 70/ 75 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED Street Light Luminaries 90 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED Street Light Luminaries 60 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver complete all as specified and directed by Engineer-in-Charge.
S&F in repair LED Street Light Luminaries 35/45 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with operating voltage range 120 to 270 V including LED driver complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Cylindrical shaped (FLUTE) LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete includingPCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Tulip shaped LED bollard with opal acrylic diffuser and IP 65 protection and 9 watt capacity warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including PCC, cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of LED post top 20 W in made in die-cast aluminium housing with decorative clear opal acrylic diffuser IP 65 protection, warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge.
M&L for detecting of fault in HT/LT UG cable any size with fault locator equipment to locate the fault in HT cable of length not less than 50 RM . Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of cable fault locator including transportation charges deemed to be included in the quoted rate. (c ) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality will levied Rs 500/- per day. (d) Necessary testing of cable after making joint will be deemed to be including in the cost of relevent item. However necessary earth work cable cutting , joint making Joint will be paid under relevant item.
S&F Busbar Chamber suitable size for set of 04 aluminium busbar 400 Amps rating ,supported with suitable size as per direction, each of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chamber shall be fixed 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete all as specified and directed by Engineer-in-Charge.
Material & Labour for surface cleaning of steel tubular poles LT 9 mtrs long including removing rusted particles and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide primer including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as specified and directed by Engineer-in-Charge. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the reapiring of coping with cement / PCC.
S & F in replacement of hot pressed moulded SMC boxes with hinged door fixing of size 325mm x 220 mmx 150 mm with MS clamp 25 x 3mm made to shape with necessry nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers incl MCB SP 6 amps and making incoming and outging connections by taking out loops of cable of any size incl necesary excavations and other civil works complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of on load changeover switches 4 pole 400 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of on load changeover switches 4 pole 200 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge.
S&F on load Change Over switch 415V in sheet metal enclosures 4 pole of capacity 320 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engr-In-Charge.
S&F on load Change Over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps 415 Volt incl making suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement MCCB TPN 100 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charg
Supply & fixing in replacement MCCB TPN 125 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charg
Supply & fixing in replacement MCCB TPN 200 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg
Supply & fixing in replacement MCCB TPN 250 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg
Supply & fixing in replacement MCCB TPN 400 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charg
Supply & fixing in replacement MCCB TPN 630 Amps 415 Volts 50 kA complete all as specified and directed by Engineer-in-Charg
M&L for in replacment of MCCB 800 A , breaking capacity 65 KA at 415 V, four pole adjustable thermal and adjustable magnetic settings with extended terminals and separator links complete including doing connections with bus bar and outgoing cables , nuts bolts washers complete all as specified and directed by Engineer-in-Charge.
Supply installation,testing commissioning in repair / replacement of horizontal single mounted single phase 220 V/250 V 6000 RPM 50 Hz, AC siren audible range 2 Km 1/4 HP complete incl necessary grounting on wall/roof etc incl connections complete all as specified and directed by Engineer-in-Charge.
Supply & Fix GI tubing with screwed socket joints, together with all tube fittings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc. and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required "medium Grade" galvanized laid in trenches or fixed to wall etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 154 above but 50 mm dia.
All as per item No 154 above but 40 mm dia.
All as per item No 154 above but 25 mm dia.
All as per item No 154 above but 20 mm dia.
All as per item No 154 above but 15 mm dia.
Supply and fix connected Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves complete all as specified and directed by Engineer-in-Charge.
All as per item No 160 above but 50 mm dia.
All as per item No 160 above but 40 mm dia.
All as per item No 160 above but 25 mm dia.
All as per item No 160 above but 20 mm dia.
All as per item No 160 above but 15 mm dia.
S&F, in replacement of fully automatic star delta submersible starter with short circuit protection in sheet metal enclousers suitable for 40 HP , 415 Volt 50 Hz with over load protector and phase preventer and taking out old U/S starters of any type and any capacity complete all as specified and directed by Engineer-in-Charge.
M&L for Opening the pressure filter 1200mm dia Make-Pentair installed at swimming pool equipment room removing the old filter media, removing all the scaling deposited on the surface area of filter assembly by using wire brush and cleaning the filter with HCL, refilling new filter media ( as per existing type)of various silica grade as required at site, re-assembling the filter assembly and apply one coat of good quality paint on the outer surface area of the filter assembly and testing for leakage for proper functioning and testing with the following specifications is maintained (a) Flow rate 125 m³/ Hr (Each), (b) Vessel dia-2000mm, (c) Filteration velocity 40m³/hr/m², (d) Working pressure 2.5 Kg/Cm² complete all as specified and directed by Engineer-in-Charge.
Supply , fixing & testing of UPVC pipes (IS: 4985-2000 class V 10 Kgf/cm2 pressure) (quick fit pipes) including injection moulded fittings (heavy duty) (plain or door) e.g. bends, junction, cowls, tees, elbow ,sockets, tee,tail pieces ,Flanges ,offsets, access pieces etc. Clamps/Supports jointing with rubber ring /solvent cement joints including cutting chase or holes in walls and floors and making good as required at Site, for 200 mm complete all as specified and directed by Engineer-in-Charge.
All as per item No 168 here in before but for 160 mm 10 Kgf/CM2
All as per item No 168 here in before but for 140 mm 06 Kgf/Cm2
All as per item No 168 here in before but for 110 mm 06 Kgf/Cm2
Material and labour for UPVC Pipe specials such as bends, tees, collars, tail pieces, flanges ,reducer,elbow sockets etc complete suitable for UPVC mains of sizes upto 200 mm complete all as specified and directed by Engineer-in-Charge.
M&L for Repair for UPVC line any type lines for stoppes leakages including excavation up to 05 RM complete all as specified and directed by Engineer-in-Charge. Note :-1.Excavation more than 10RM shall be measured & paid separately. 2.using T&P with UPVC fittings such as Nipple , socket , tee ,Elbow, bend etc complete all as specified and directed. (GI fitting shall be measured and paid separately).
All as per item No 173 above but UPVC Tail Pices 110 mm
All as per item No 173 above but UPVC Tail Pices 140 mm
All as per item No 173 above but UPVC Tail Pices 160 mm
All as per item No 173 above but UPVC Socket 100 mm
All as per item No 173 above but UPVC Socket 160 mm
All as per item No 173 above but UPVC Tee 140 mm
All as per item No 173 above but UPVC Elbow 140 mm
All as per item No 173 above but UPVC Elbow 160 mm
All as per item No 173 above but UPVCReducer 140 mm to 160 mm
All as per item No 173 above but UPVC Reducer 160 mm to 200 mm
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer to new steel and iron surfaces over 10cm in width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for repair to valve Pit chamber of any size within brick masonary valve chamber, PCC foundation, plastering and necessary excavation and earth work in hard/ dense soil, MS sheet cover 3.15 mm thickness along with angle iron frame of size 40 x 40 x 6mm with locking arrangement with necessary fixing matrials like hinges, nut/bolts etc (valve chamber cover shall be opened in two halves) and painting to MS cover with one coat of red oxide primer and two coats of synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge.
Supply, assembling and lowering into bore 3" dia MS casing pipe/column pipe with flange type and screwed, socketed and welded, ISI Marked, lengths upto 03 Mtrs long, heavy duty with wall thickness not less than 8 mm incluidng necessary fittings (i.e MS sockets) and jointing from ground level duly painted with two coats of bituminous paint on external surfaces of pipes complete all as specified and directed by Engineer-in-Charge.
All as per item No 187 but 50 mm( 2") bore
Development of bore well by air compressor of capacity 200 PSI 900 CFM as required on ground, till to get the clear water complete with transportation charges and its accessories including carrying out yield test complete all as specified and directed by Engineer-in-Charge. Note : Yield test shall be carried out during developing of bore well. The rates qouted against this item shall deem to be included for yield testing.
Taking out from bore well submersible pump motor, column pipe with man power/Chain Pulley arrangement and refixing after development and Repair of Submersible pump and motor complete all as specified and directed by Engineer-in-Charge.
M&L of flanges rubber gasket, nut and bolts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of HDPE Flexible borewell pipe of 50 mm (2" inch) dia and with 2 male connector nipples, clamp etc complete all as specified and directed by Engineer-in-Charge.
Material & Labour for repairs to existing LT panel board at Pump houses including painting with one coat of synthetic enameled paint to steel surfaces including preparation after scraping, filling, cavities etc, including replacement of damaged bus bar, lugs, copper wire etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCCBs 415 volts, 4 pole, 25 KA, 100 Amps capacity complete all as specified and directed by Engineer-in-Charge.
S & F in replacement Volt Meter 0 to 500 Volts digital square type 4” complete all as specified and directed by Engineer-in-Charge.
S & F in replacement Ammeter 0 to 200 Amps digital Square type 4” complete all as specified and directed by Engineer-in-Charge.
S & F in replacement Indicating Lamp set of three (Red , Yellow & Blue) complete all as specified and directed by Engineer-in-Charge.
M&L for repair / replacement of Starter in existing LT panel board at Pump House pertaining to water supply and checking of electrical connection repairing to fault & replacement of U/S items complete including testing commission complete all as specified and directed by Engineer-in-Charge. Note :- U/S items to be replaced shall be measured & paid separately vide following items
Supply only Contactor as per suitable in Existing Panel complete all as specified and directed by Engineer-in-Charge.
Supply only Spare kit without coil for contactor type as per suitable in existing Panel complete all as specified and directed by Engineer-in-Charge.
Supply only Electronic timers as per suitable in existing Panel complete all as specified and directed by Engineer-in-Charge.
Supply only over load relay as per suitable in existing Panel complete all as specified and directed by Engineer-in-Charge.
Supply only for Fuse holder & Fuse bases suitable for in existing Panel complete all as specified and directed by Engineer-in-Charge.
M&L for Repair to CI line any type lines for stoppes leakegs including excavation up to 10 RM. (80 to 200 mm) complete all as specified and directed by Engineer-in-Charge. Note :-1.Excavation more than 10RM shall be measured & paid separately. 2. Run lead joints shall be measured & paid separately.
Taking out/burning out of leaking and damaged lead joints of the existing CI mains from the position including removing the old lead carefully with out damaging to the pipe complete for the following bore of pipes (Size of 80 mm bore) complete all as specified and directed by Engineer-in-Charge. (Note :- Excavation and earth work will be measured and paid separately )
All as item No 206 above but 100 mm bore
All as item No 206 above but 150 mm bore
Material and labour for run lead joints including jointing materials such as spun yarn etc complete for the following sizes complete all as specified and directed by Engineer-in-Charge.
All as per item No 209 above but 150 mm dia of pipe
All as per item No 209 above but 100 mm dia of pipe
All as per item No 209 above but 80 mm dia of pipe
M&L for Repair to GI pipe line any type lines for Rectification of leakages including excavation up to 10 RM.(15 to 50 mm) complete all as specified and directed by Engineer-in-Charge. Note :-1.Excavation more than 10RM shall be measured & paid separately. 2.using T&P with GI fittings medium grade such as Nipple , socket , union , tee ,Elbow, bend etc complete all as specified and directed. (GI fitting shall be measured and paid separately as supply only:
(a) GI nipple 15 mmx100mm
(b) GI nipple 20 mmx100mm
(c) GI nipple 25 mmx100mm
(d) GI nipple 40 mmx100mm
(e) GI nipple 50 mmx100mm
(f) GI Socket 15 mm
(g) GI Socket 20 mm
(h) GI Socket 25 mm
(i) GI Socket 40 mm
(j)GI Socket 50 mm
(k) GI Union 15 mm
(l) GI Union 20 mm
(m) GI Union 25 mm
(n) GI Union 40 mm
(o) GI Union 50 mm
(p) GI Tee 15 mm
(q) GI Tee 20 mm
(r) GI Tee 25 mm
(s) GI Tee 40 mm
(t) GI Tee 50 mm
(u) GI Elbow 15 mm
(v) GI Elbow 20 mm
(w) GI Elbow 25 mm
(x) GI Elbow 40 mm
(y) GI Elbow 50 mm
(z) GI Reduce Elbow 15 mm
(aa) GI Reduce Elbow 20 mm
(bb) GI Reduce Elbow 25 mm
(cc) GI Reduce Elbow 40 mm
(dd) GI Reduce Elbow 50 mm
Taking out existing unserviceable/ broken / damaged CI sluice valve from its existing position and Supply & fixing CI sluice valve stainless steel, spindle CI body class –I, PN-1.6 ISI marked both end flanged and drilled and fixed by means of new nuts, bolts and washer including providing rubber gasket of suitable thickness of following sizes complete all as specified and directed by Engineer-in-Charge.
All as per item No 244 above but 200 mm dia bore of pipe
All as per item No 244 above but 150 mm dia bore of pipe
All as per item No 244 above but 100 mm dia bore of pipe
All as per item No 244 above but 80 mm dia
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 100 mm dia complete all as specified and directed by Engineer-in-Charge
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 150 mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of unservicable water type of Butterfly valve( as per existing, PVC Type) of size 150 mm dia (OD 160mm) having matching flange complete all as specified and directed by Engineer-in-Charge
M&L for replacement of unserviceable water type butterfly valve (As per existing)of size 100mm dia (OD 110mm) having matching flange complete all as specified and directed by Engineer-in-Charge.
M&L for repairing gland packing of sluice valve including nut, bolts of suitable size 80 mm to 200 mm bore etc complete all as specified and directed by Engineer-in-Charge.
Supply only calcium based Granular for Chlorination of water packed in 45/50 Kg drums and sealed complete all as specified and directed by Engineer-in-Charge.
Supply only chlorine test kit with PH colured sample complete with all testing fitment and OT solution in rexine box complete all as specified and directed by Engineer-in-Charge.
M&L for chemical and bacteriological analysis of Raw water collected from all the pump house situated in AF stn chandinagar complete all as specified and directed by Engineer-in-Charge.
M&L for chemical and bacteriological analysis ofchlorinated water collected from distribution line PH NO 1 situated in AF stn chandinagar complete all as specified and directed by Engineer-in-Charge.
Material and labour for "lifting and Lowering of any acpacity" Submersible Pump Set of capacity 30 HP for repair/ Overhauling /rewinding /devolpment incl increasing the length of delivery pipe/or any other requiremwnt at site at tube well installation at AF Station chandinagar with man power/Chain Pulley arrangement including shifting to local workshop for repair and to bring back after repair at site including testing and commisioning complete all as specified and directed by Engineer-in-Charge. Note :- Any minor part if required will be provided by contractor without any extra cost.
All as per item No 258 above but Capcity of 10 /15 HP
M & L for Dismantling and strip opening of burnt submersible pump of capacity 30 HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commmisioning such as (i) Impeller GM . (ii) Distance bush SS.(iii) Guide Bush (iv) Neck ring gun metal (v) Impeller key (vi)Guide van (vii) Sand Guard complete all as specified and directed by Engineer-in-Charge.
All as per item No 260 above but 10 /15 HP
M & L for Dismantling and strip opening of burnt Booster pump motor of capacity upto 15 HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commmisioning complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs/replacement of Electric motor Single phase 50 HZ 1/8 HP assy Suitable to mount on decrin mixing tank along with agitator shaft and blade complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of connection pipe suitable for connecting to decrin dosing pump to Header( 2 Mtr long 8 mm internal dia) complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of circuit of speed of Dozing pump complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of injector Nozzle of Decrin dozing pumpomplete complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Regulator Knob of dozing pump complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of power cord of dozing pump 2 mtr long plug top 5 AMP 240 volt AC complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 50 to 110 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 40 to 45 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX 25 to 32 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 3 pole power contactor with NO / NC block suitable for MNX upto 18 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of unserviceable MCCB 63 amps 415 volts TP 16 KA complete all as specified and directed by Engineer-in-Charge.
Material and labour for CI specials such as bends, tees, collars, tail pieces flanges etc complete suitable for CI mains of sizes upto 150mm complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of Submersible cable flat PVC insulated Sheathed copper Conductor 10sqmm 3 Core 2run complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of Submersible cable flat PVC insulated Sheathed copper Conductor 16 sqmm 3 Core 2run complete all as specified and directed by Engineer-in-Charge.
S&F in replacement under water illumination Standard Underwater light 300W x 12 V (suitable for Existing ) Niche in Polypropylene and glass fibre with 3 mtr 4 sqmm electric cable and in ABS rim including water proffing jointing connection and tested and Fiber Glass Disconnecting from supply and dismantling and repair of under water light fitting water proofing, wiring, driver etc complete all as specified and directed by Engineer-in-Charge.
M&L for Deck Box in ABS with 3 entries of 3/4"or PG-16 coupling with necessary, connection and tested complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of unserviceable water proofing cable for lighting multistanded copper conductor cable 6 Sqmm 02 core complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of unserviceable water proofing cable for lighting multistanded copper conductor cable 10 Sqmm 03 core complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of Ladder for OHT/ UG sump with square bar,angle iron,channel, Flat Iron and etc welding, drilling, cutting with one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of on load changeover switches 4 pole 200 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of on load changeover switches 4 pole 400 Amps , 415 volts , open type fixed in existing panel allows changeover from main supply to generator supply & vice versa complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of DOL starter for 10 HP with complete protection complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Suction sweeper/ Vaccume Cleaner of SS ( 10" width and 03 feet length) trolly mounted with 03 Hp Pump Set complete fittings for connecting hoses and 3' ss head ( incl Leaf net, wall brush , telescopic pole 4.8 m ) complete set of Suction sweeper / vaccume cleaner of PVC pipe 50mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC suction hose flexible pipe of 50 mm dia and Rope with 2 male connector nipples, clamp etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of heavey duty swimming pool cleaner wall brush with Aluminium handle with stainless steel bristles width 18" and 7' feet height/length of handle complete all as specified and directed by Engineer-in-Charge.
Supply and laying and testing in replacement of unserviceable for Ductile Iron pipes of 150 mm bore with spigot and socket ends centrifugal cast, class K-7 as per IS 8329 in any length suitable for and including rubber tightening joints laid in trenches including taking down complete all as specified and directed by Engineer-in-Charge.
M/S Parshant Associates
YASHVI ENGINEERS
M/S Anand Enterprises
Singh Associates
NAVYUG VYAPARI
J P ENTERPRISES
M/S JPS Electrical Engineer & Contractor
yameen enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .