Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹21.2 L+₹1.3 L (6.32%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹21.2 L+₹1.3 L (6.37%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹21.7 L+₹1.7 L (8.72%)Rejected-Finance KHABAM CHUMRIETHONG NEAR IGAR SOUTH P O MATRIPUKHRI IMPHAL 795002 | IMPHAL | IMPHAL WEST | MANIPUR | 795002 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹22.4 L+₹2.5 L (12.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Jul 2023, 6:00 pmClosed
GE 869 EWS
GE 869 EWS PIN 913869 C/O 99 APO
REPAIR / REPLACEMENT OF INTERNAL WIRING AND CONNECTED ITEMS SWITCH, SOCKET AND ELECTRICAL FITTING AT LOWER LEIMAKHONG, UPPER LEIMAKHONG, CENTRAL SECTOR AND KOIRENGEI MIL STN
2023_MES_606235_1
8521/E8
Open Tender
Civil Works
Item Rate
210 days
LEIMAKHONG MIL STN
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹40,000
Yes
23 Oct 2023
27 Jun 2023
31 Jul 2023
27 Jun 2023
29 Jul 2023
15 Jul 2023
Amount
Schedule 'A'
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed) (a) One light point controlled by one, one way switch
(b) One bell point point controlled by one, one way switch.
(c) One celling / exhaust fan point controlled by one, one way switch.
(d) One socket outlet 5 Amps 3 pin on independent board complete all as specified and directed.
(e) One socket outlet 5 Amps 3 pin on same board complete all as specified and directed.
All as per item No. 2.00 here in before but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket outlet on independent board and multistrand insulated earth continuity conductor of size 2.5 Sqmm complete all as specified and directed.
S&F in replacement of modular switch 6 Amps, single pole, one way one module complete all as specified and directed.
S&F in replacement of modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed.
S&F in replacement modular socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed.
S&F in replacement of Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed.
S&F in replacement of modular switch 1 way 16 Amps, one module complete all as specified and directed
S&F in replacement of modular bell push switch 6 Amps, one module complete all as specified and directed
S&F in replacement of buzzer, ding dong, AC, 230 volts, single pole, complete all as specified and directed
S&F in replacement of modular white cover plate with frame for fixing of 8 module complete all as specified and directed.ected.
S&F in replacement of modular white cover plate with frame for fixing of 6 module complete all as specified and directed.
S&F in replacement of modular white cover plate with frame for fixing of 4 module complete all as specified and directed.
S&F in replacement of modular white cover plate with frame for fixing of 3 module complete all as specified and directed.
S&F in replacement of modular white cover plate with frame for fixing of 2 module complete all as specified and directed.
S&F in replacement of modular white cover plate with frame for fixing of 1 module complete all as specified and directed.
S&F blank speacer plate for single module complete all as specified and directed.
S&F in replacement of Modular step type module electronic fan regulator heavy duty 120 watts 240 volts complete all as specified and directed.
Taking down old unserviceable main switch/ DBs/ MCB DBs with MCB including making good the disturbed surface complete as directed.
S&F of sheet metal enclosure for MCB’s distribution board, 240 Volts, 4 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed.
S&F of sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door for breaking capacity 10 KA complete all as specified and directed.
S&F of sheet metal enclosure for MCB’s distribution board, 240 Volts, 12 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door for breaking capacity 10 KA complete all as specified and directed.
S&F in replacement of Sheet metal enclosure vertical DB (for DB's when MCCB / MCBs to be used) , triple pole and neutral double door , IP - 54 , 1 way , 415 volts with rated bus bar of size phase 200 Amps and neutral 300 amp including MCCB 4 pole , 100 Amp , 16 KA complete all as specified and directed.
S&F in replacement of MCB triple pole and neutral 40 to 100 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F of MCB triple pole and neutral 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F of MCB single pole 06 to 32Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed.
S&F in replacement of PVC Board (30 x 25 x 5) cm depth medium quality ISI marked complete all as directed.
Taking down old unserviceable sub main wiring of any size complete all as specified and directed.
M & L for sub main wiring with two single core 10.00 Sqmm PVC FRLS insulated unsheathed cable multi-stranded copper conductor drawn through and including PVC casing/capping of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 6.00 Sqmm PVC insulated unsheathed one core multistranded copper conductor earth wire complete all as specified and directed. (Note: Two run of single core cable and one run earth wire will be measured as one length)
M & L for sub main wiring with two single core 6.00 Sqmm PVC insulated FR-LSH unsheathed cable multi-stranded copper conductor drawn through and including PVC conduit / PVC casing capping of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 4.00 Sqmm PVC insulated unsheathed one core multistranded copper conductor earth wire complete all as specified and directed. (Note: Two run of 6 sqmm and one run of sqmm earth wire including PVC conduit should be measured & paid as one length )
M & L for sub main wiring with two single core 4.00 Sqmm PVC insulated FR-LSH unsheathed cable multi-stranded copper conductor drawn through and including PVC conduit / PVC casing capping of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 2.5 Sqmm PVC insulated unsheathed one core multistranded copper conductor earth wire complete all as specified and directed. (Note: Two run of 4 sqmm and one run of 2.5 sqmm earth wire including PVC conduit should be measured & paid as one length )
M & L for sub main wiring with two single core 2.5 Sqmm PVC insulated FR-LSH unsheathed cable multi-stranded copper conductor drawn through and including PVC casing/capping of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 1.5 Sqmm PVC insulated unsheathed one core multistranded copper conductor earth wire complete all as specified and directed. (Note: Two run of 2.5 sqmm and one run of 1.5 sqmm earth wire including PVC conduit should be measured & paid as one length )
M & L for sub main wiring with two single core 1.5 Sqmm PVC insulated FR-LSH unsheathed cable multi-stranded copper conductor drawn through and including PVC casing/capping of suitable size with all fittings and fixing accessories on roof, walls, ceiling etc. including 1.0 Sqmm PVC insulated unsheathed one core multistranded copper conductor earth wire complete all as specified and directed. (Note: Two run of 1.5 sqmm and one run of 1.0 sqmm earth wire including PVC conduit should be measured & paid as one length )
Taking down /dismantling of old light fitting of any type complete all as specified and directed.
S&F of 15 watt pearl ultima is a high performance low-height round recess mounted LED slim downlight suited for requirements of any modern professional workspace in cool white/warm white/natural white.Robust PDC housing ensures long system.Narrow rim renders a pleasing aesthetic look and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
S & F essential smart bright track light 8 watt is a high performance hassle free solution for upto 5 years of use in cool white/warm white/natural white, range has high efficacy of up to 100lm/w and aluminium housing for better thermal management.Available in black &white color housing and all as specified and directed.
S&F recess mounting luminaire pearl ultima, environmental friendly, new genneration ,aesthetically designed with high brightness SMD LEDs as light source suitable for armstrong/grid ceiling, 2x2 ft, 12W, 240V in cool white/warm white/natural white and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
S & F LED tube light fitting 20 W LED 6500K basic all purpose surface and wall mounted LED robust and high performance batten LED luminar comprises of extruded channel in thermally conductive materail glare and smooth light complete all as specified and directed .
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 15 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting all as directed by Engineer-in-Charge.
S&F in replacement of Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type complete all as specified and directed.
Taking down old unserviceable service wire/cable including batten/suspending wires complete all as specified and directed.
M&L for Service wire PVC insulated and PVC sheathed stranded Aluminium conductor 10 sq mm 2 Core flat fixed to walls or suspended by insulating hanger not more than one meter apart including 4mm dia GI suspension wire and binding with 2mm dia new GI wire with reel insulator complete all as directed.
S&F in replacement of PVC casing caping of size 20x12mm, of heavy grade including with all fitting accessories required at site complete all as specified and directed.
S&F in replacement of PVC casing caping of size 25x15mm, of heavy grade including with all fitting accessories required at site complete all as specified and directed.
S & F LED bulb 12 watt in cool white/warm white/natural white complete all as specified and as directed.
S & F LED bulb 5 watt in cool white/warm white/natural white complete all as specified and as directed.
M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of G I or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified and as directed.
M/s Nongmaithem Construction
Manipur Steel Industries(INDIA)
SKYLINE CONSTRUCTION
M/s Ritz Marketing
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .