Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | ₹7.8 L Quoted ₹6.6 L | L1 | Accepted-AOC BIDDER IS L1. RECOMMENDED BY TC APPROOVED BY CA. |
| 2 | L2₹6.9 L+₹32,429 (4.93%)Rejected-Finance AT JAWAHAR NAGAR PO BERMO DIST BOKARO PIN 829104 JHARKHAND | BERMO | BOKARO | JHARKHAND | 829104 | ₹6.9 L+₹32,429 (4.93%) | L2 | Rejected-Finance BIDDER IS NOT L1. BID REJECTED. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Bidder has not submitted all the documents as per NIT. Bid is rejected. |
| Sl No | Description | Qty | Unit | CITY ELECTRICALS L1 | M/S JAI MAA ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.01 | Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required | 400 | kg | 147 ₹58,800 Lowest | 154 ₹61,600 |
| 1.02 | Supply and erection of galvanized stay set for 11 KV O.H. Line complete with 19/20 mm dia x 1.8 mtr long stay rod , anchor plate of size 45 cm x 45 cm x 7.5mm, thimble , stay clamps ,turn buckle ( 20mm x 600 cm ) 7/4.00 mm dia GI stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required. | 5 | set | 4,386 ₹21,930 Lowest | 4,605 ₹23,025 |
| 1.03 | supply and erection of clamp nut bolt with washer | 20 | set | 120 ₹2,400 Lowest | 126 ₹2,520 |
| 1.04 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required | 8 | each | 1,924 ₹15,392 Lowest | 2,020 ₹16,160 |
| 1.05 | Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required | 8 | set | 409 ₹3,272 Lowest | 429 ₹3,432 |
| 1.06 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required | 2 | set | 4,158 ₹8,316 Lowest | 4,366 ₹8,732 |
| 1.07 | Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required | 2 | each | 926 ₹1,852 Lowest | 972 ₹1,944 |
| 1.08 | Supply and erection of 11 KV Pin insulator complete with large steel head GI pin, nuts washer etc as required. | 120 | no | 249 ₹29,880 Lowest | 261 ₹31,320 |
| 1.09 | Supply and erection of 11 KV disc insulator for 11 KV OH line with galvanized insulator fittings ball and socket type and complete with galvanized strain clamps bolts and nuts washers etc as required. | 200 | no | 818 ₹1,63,600 Lowest | 859 ₹1,71,800 |
| 1.10 | erection of 8 SWG GI wire for earth continuity and cradling | 262 | kg | 29 ₹7,598 Lowest | 30.45 ₹7,977.9 |
Tender Value
₹7.8 L
EMD Value
₹9,800
Closing Date
11 Apr 2025, 9:00 amClosed
PE, ENM
PE ENM, PO OFFCE, BOKARO COLLIERY
Preventive repair and maintenance of 11KV incoming overhead line from MRSS, Kargali and Main substation, AKK OCP to Gandhi nagar sub station in respect of Bokaro Colliery
2025_CCL_333604_2
CCL/BnK/Bokaro/EnM /24-25/14
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
BOKARO COLLIERY
Please refer Tender documents.
2 documents required · 2 mandatory
₹9,800
26 Jul 2026
31 Mar 2025
12 Apr 2025
1 Apr 2025
11 Apr 2025
1 Apr 2025
1 Apr 2025 - 7 Apr 2025
Amount
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required
Supply and erection of galvanized stay set for 11 KV O.H. Line complete with 19/20 mm dia x 1.8 mtr long stay rod , anchor plate of size 45 cm x 45 cm x 7.5mm, thimble , stay clamps ,turn buckle ( 20mm x 600 cm ) 7/4.00 mm dia GI stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc as required.
supply and erection of clamp nut bolt with washer
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required
Supply and erection of 11 KV Pin insulator complete with large steel head GI pin, nuts washer etc as required.
Supply and erection of 11 KV disc insulator for 11 KV OH line with galvanized insulator fittings ball and socket type and complete with galvanized strain clamps bolts and nuts washers etc as required.
erection of 8 SWG GI wire for earth continuity and cradling
supply of 6 SWG GI wire for earth continuity and cradling
Dismantling of dog conductor, Damage disc and pin insulator, Damage G. I. Wire etc whichever required.
supply of wireman for detection of fault including patrolling (will reach the site within one hour of intimation)
supply and providing 800 amps- male contact of GOAB horizonatal/ vertical type
supply and providing 800 amps- female contact of GOAB horizonatal/ vertical type
wire net 0.5 mtr long of copper made for repairing of vertical type gang operating switch
repairing of GOAB swich after removal of old damaged accessories
supply and providing post insulator of 11 KV grade complete set
jumpering of conductor into GOAB
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 120 sq mm
handling of cable i.e dismantling of cable from pole and re ecection of cable on pole after heat shrinkable
dismantling of conductor for replacment of damaged disc insulator and erection of conductor after replacment of insulator by making arrangement to hold the conductor on overhead line
dismantling of conductor from pin insulator including unbinding of aluminium wire for holding conductor with pin insulator for replacment of pin insulator
dismantling of jumper
re-erection of jumper
meggering of overhead line with all accessories i.e megger, discharge rode and wire
Total impact of GST for the purpose of CTC
M/S JAI MAA ENTERPRISES (BID ID -1146577)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .