Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.1 L
Closing Date
29 Dec 2025, 3:30 pmClosed
Provision/shifting of telecom facility including FOIS network for development of various goods shed and changing room on Solapur division of Central Railway.
SUR-N-T-2025-26-30~CR
SUR-N-T-2025-26-30
Open
Works - General
8 Months
Solapur, Maharashtra
₹0
₹2.1 L
29 Dec 2025
4 Dec 2025
15 Dec 2025
01-Telecom Items
Item Breakup - 01-Telecom Items
Supply, Installation, Testing and commissioning Numbers of PCM TDM integrated access Device (Make: MROTEK, Model- Maple/4C or similar) equipped with of 4E1 ports and 3 slots & one slot populated with 2W/4W E&M supporting up 8 interfaces balance two slots empty unit support 124 DSO slot cross connect. E&M module to support gain/loss adjustment for LVCD application. Unit support both AC/DC power supply (AC 230 Volt/ DC 24V to 48V) including 50 pin cable one number for supporting both 2W/4W E&M, AC adaptor one number. (Inspection by Consignee)
Supply of OFC Pluggable Module suitable to 8E Numbers accommodated in Maple 4CS equipment of MROTEK make or suitable to the equipment under supply as above. (Inspection by Consignee) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of SFP modules single mode fiber, from Numbers Cisco or HP or Juniper or Watchdog. (Inspection by Consignee)
Supply of single line caller ID hand free Numbers telephone with speaker of make Beetel M 53 or latest with RJ 11 rosettes and 3 No. of pen torch cells Eveready or Novino to be supplied with each instrument and warranty of 01 year. (Inspection by Consignee)
Supply of maintenance console as per Numbers specification enclosed. (Inspection by RITES)
Supply of : External Hard Disc SSD ITB Silver Numbers colour Make SAMSUNG for station Data Back up (Type C and A) in portable format from ADATA or Scandisk or Seagate or Transcend or Samsung. (Inspection by Consignee)
Supply of 8 Port Smart Managed Switch with 8- Numbers Port Giga PoE Ethernet & 2-Port Giga SFP loaded with SM FiberTransceiver (1310nm) of reputed make such as TP Link/DLink/Cisco/Juniper only. (Inspection by Consignee)
Supply of Media converters with one Fiber port Pair (SC connector) and four Ethernet ports, supporting port isolationand with built in AC Power supply. Model: FABIO 104L of make MRO- TEK or similar model of RAD, ANDA Telecom,ZYXEL or CTC only. (Inspection by Consignee)
Supply of High throughput LAN extenders as Pair per RDSO Specification No.RDSO/SPN/TC/80/2018. (Inspection by Consignee)
Supply of on line UPS with isolation transformer Numbers suitable for signal phaseAC input & single phase AC output, floor mounted type. Rating of UPS 3.0KVA, indicative back up time 120 minutes, make APC or Immerssion or Microtek or Champion with SNMP module card installed in UPS. (It includes external battery of min 26AH along with suitable battery stand) (Inspection by Consignee)
Supply of STP (shielded Twisted Pair) CAT-6 Boxes cable (compliant to EIA/TIA 568C (10/100/1000 link) from D-Link, Finolex., Lucent or DAX Make (1 Box-305 mtrs). (Inspection by Consignee)
Laying of CAT 6 cable with proper identification Metre marks and as per the instruction of site engineer.
Supply of OFC patch cord with connector at Numbers both ends single mode Simplex 05 Mtr. Make of 3M or Sterlite or Finolex or Raychem or D-Link. (Inspection by Consignee)
Supply of factory molded Cat-6 patch cord 1 Numbers Mtr from D-link or DAX or Krone or Finolex make. (Inspection by Consignee)
Supply of RJ 45 connector suitable with CAT 6 Numbers Cable from make/brand D-LINK or DIGISOL or similar. (Inspection by Consignee)
Supply of PVC switch board 10 Pair, 0.5mm dia Metre twisted pair PVC insulated, PVC sheathed, ATC copper conductor as per TEC specification no. TEC/GR/WIR009/05 March 2011 or latest from Network or Finolex or Synergy or Delton make. (Inspection by Consignee) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of PVC switch board 05 Pair, 0.5mm dia Metre twisted pair PVC insulated, PVC sheathed, ATC copper conductor as per TEC specification no. TEC/GR/WIR/06/03 March 2002 or latest from Network or Finolex or Polycab or Delton make. (Inspection by Consignee)
Supply of multiport I/O box surface mounting Numbers having two RJ-45 port and three RJ-11 port from D-Link or Legrand or Anchor or similar reputed make. (Inspection by Consignee)
Fixing of UTP I/O box as per the instruction of Numbers site Engineers of the Railways.
Supply of Krone module of 10 pair each from Numbers 1600.00 Krone or DAX or OBO or R&M make. (Inspection by Consignee)
Supply of Toughened moulding composite DP Numbers box for 20 pair Krone module along with mounting, fixing bracket size of DP box 230mm X 170mm X 105mm similar to ITR120 module. Make Sintex, Network, Krone. (Inspection by Consignee)
Supply of 19" size 42U rack of dimension Numbers 2200MM X 600MM X 600MM with all accessories like power distribution board with 12 sockets, 4 - Fan Tray, cable manager on either side of the rack, spike buster etc of resident or Valrack or HCL or APW make for data com equipments. (Inspection by Consignee)
Supply of 12 port LIU, 19 inch rack mountable Numbers as per following specification: a) It should have 12 SP type ports for termination of SM optical fibres. b) It should be rack mountable with 1U height. c) It should be equipped with front managed saddle for jumper/patch cord management. d) It should have 12 SC termination. e) It should be equipped with adequate nos. of splicing trays to splice 12 fibres. f) It should have proper rubber grommet for cable protection and to minimize dust build up. g) It should be fully loaded with all the accessories for splicing and termination of fibres. h) It shall be of reputed make like D-Link or 3M or Digilink or Molex make. (Inspection by Consignee)
Installation & commissioning of 12 port LIU with Numbers all accessories and shall be used for terminations of optical fibers into the splice trays supplied with it, it shall be installed inside the 19 inch rack using all required fixing/ installation material like nuts, bolts, screws and cable ties etc. as per requirement. The splice trays shall be placed and secured into the LIU after splicing. The SC terminations shall be fixed and secured after splicing of the pigtails into the LIU. It shall be ensured that the movement of the trays is easy and free of any obstructions.
Supply of optic fiber pigtails for termination of Numbers OFC cables with following specification: a) It shall be single mode SC/SC type with push pull mechanism or as per site requirement and fully compliance with latest industry standard. b) It shall have length of 2 Meters at least. c) It shall have SC connector at one end and other shall be loose for splicing. d) It should be of reputed make D-Link or 3M or Digilink or Molex. (Inspection by Consignee) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Blowing/Drawing of OFC cable in HDPE/DWC Kilometre duct and protective work, as per direction of site engineer.
Splicing/ dropping/termination of each fiber/ Numbers pigtail in LIU/IO box/ terminal joint through fusion splicing for termination of OFC cables. The fibers terminated shall be tested and test report (hard copy and soft copy) shall be submitted to the Railways site in-charge for records. each fiber shall be properly marked with necessary ferrules/tags, as per following specification: i) The optical fibre cables shall be entered in to the rack through cable entry and using the cable guides. ii) The loosened ends of the fibres and pigtails shall be properly prepared for termination in to the already fixed LIU. iii) Each of the fibre shall be spliced with a pigtail by the method of fusion splicing using a Fusion Splicing Machine of standard reputed make. The splicing shall be done carefully by a skillful person. iv) The splices shall be carefully placed and well secured in the splice trays of the LIU. v) Each fiber /pigtail shall be properly marked with necessary ferrules/ tags.vi) The extra length of the fibers / pigtails shall be coiled and placed and secured with cable ties. vii) The optical connectors of the pigtails shall be placed into the patch panel as per the numbering of fibers.viii) All of the terminated fibers shall be tested with OTDR and test report (Hard copy and Soft copy) shall be submitted to the Railways site In-charge for records.
Supply of Optical Fiber Termination and Numbers Distribution Management System for 48 Core OFC fully loaded with Pigtails and Couplers Make Raychem/R&M or 3M equivalent. (Inspection by Consignee)
Supply of OFC Joint Closure for 24 Fibres as per Numbers RDSO specification no. RDSO/SPN/TC/68/2007 (Rev. Amdt. 1-1 or latest). (Inspection by Consignee)
Supply of PVC casing & capping of size 25mm x Metre 25/32mm and 2mm thickness piece with all accessories like jont, bends etc of Precision, Garware make or similar standard make. (Inspection by Consignee)
Supply of PVC channel of size 50x50 mm with Metre all accessaries like jont, bends etc of precision, Garvare make or similar standard make. (Inspection by Consignee)
Fixing of PVC casing & caping or PVC Channels Metre or conduit pipe on wall etc. with suitable fasteners as per route given by and as per instruction of site engineer of Rly. This inclues breaking up of wall for cabling & painting it to original level & laying of cables.
Digital Earth Tester Make- Motwane DET-20 or Numbers similar. Following specification- 1) 3.5 digit LCD display with Max Reading 1999. 2) Earth Resistance Range of 0.01 ohm to 1999 ohm. 3) Rechargeable Internal Ni-MH Battery 4) 4 Wire Soil Resistivity Measurement 5) Measurement Method-3 terminal & 4 terminal. Type tested as per IS-9223. (Inspection by Consignee) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of Tool Kit consisting of following tools Numbers 1) Long Nose Plier (200mm)-01 No. 2) Cutter Diagonal (200mm)- 01 No.3) Insulated Screw Driver Set -01 No. 4) Hammer Steel (500 gms)- 01 No.5) Hack Saw Small and big -1 No. each 6) Spanner Set-01 No. 7) Stripper-01 No. 8) Combination Plier-1 Nos. Note: Item no. 1) to 8) shall be of reputed make Taparia/ Bosch/ Stanley only.9) Wrapping Tools-01 No. 10) Twezeer-01 No.11) Soldering Iron- 25W/220Volts & 65W/220V-01 No. each of reputed make SOLDRON/ GOOT/ HAKKO only.12) Tool bag of suitable size to keep & carry above tools. (Inspection by Consignee)
Supply of HDPE duct 50mm dia, inner dia Metre 42mm and wall thickness 4mm, permanently luricated etc supplied from TEC approved sources. (Inspection by RITES)
Laying & fixing of HDPE duct for protection of Metre cable in trenches or roof wall etc as per route given by site Engineer of Railways.
Supply of GI pipe, inner dia. 100mm dia. B-class Metre as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings.TATA,JINDAL/ZENITH BIRLA make. (Inspection by Consignee)
Fixing of GI pipes for crossing the culverts, Metre bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Supply of Double walled corrugated pipe made Metre up of polyethylene of size 103.5 mm inner dia and 120 mm outer dia in 6 m straight length as per british standard No BSEN 50086-1. (Inspection by Consignee)
Laying of DWC/RCC pipes complete with clamp Metre and necessary fixtures.
Supply of RCC pipes half round of size 150mm Numbers 8000.00 dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. (Inspection by RITES)
Laying of RCC half round cement pipe of Numbers 4000.00 appprox. Size (150/300mm dia X 2 mtr. length) inside the trench after laying of cable. Pipes shall be placed as per directives of site engineer.
Design, supply, fabrication and errection of Metre stainless steel cable ladder and cable tray of size 300 x 600 mm of 21 SWG with suitable top cover air tight, modular and detachable at fixed interval, under COPand under roof of FOB and at any open location (may be needed to be placed above iron stand) as per site conditionand as per instructions of Railway site incharge, good finishing and accuracy to be maintained through out the length. The work shall be done as per instruction of site engineer. (Inspection by Consignee)
Supply of A class earthing - Supply of ESR Set ALTEC TERRA STREAMER Lightning Arrester with SS adaptor (TSP30, 50 Mtr. Radius) SPN: NFC-17-102-2011. (Inspection by RITES)
Installation & commissioning of A-Class Station Lightning protection complete include base plate with base mast & accessories. SPN: NFC- 17-102-2011 and as per IS 2309:1989. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of Class B&C surge protection Device Numbers (SPD) type I & II with visual indication and potential free contract to remote monitoring as per RDSO spec No. RDSO/SPN/165/2012 version 3.0 or latest and IEC standard 61643 for signals line 230 V AC application with handling lightning surges of 10/350 microseconds and switching surges of 8/20 microseconds. One set consists of 3 Nos of SPD (Two Nos of B Class (L N, N-E) and one no of C class (L-N) all enclosed in a box with KEMA or VDE certified as per latest IEC 61643-11-2011 standard class B&C surge pretection device required with Three modules only. (Inspection by Consignee)
Supply, Transporting and installation of Numbers concrete (RCC) route indicators at intervals of 50 meters as per the instructions of site incharge. They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK 12/10 of RVNL SC. In case of Telecom quad cable joint locations it shall be painted with RED colour. (Inspection by Consignee)
Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/ bricks, clearing of route, bushes etc. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. In case depth of trench is not achievable due to site conditions proportionate payment will be made.
Excavation of cable trench as per cable route cum plan,1 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/bricks, clearing of route, bushes etc. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. In case depth of trench is not achievable due to site conditions proportionate payment will be made.
Digging of trench 1.0 M deep from rail cum flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs. wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe covered separately. The ballast disturbed be screened and dressed as required by Engineer- in-charge or his representatives and road tarred immediately. Drg. No. SK 806. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Horizontal boring of cable duct of minimum 2.0 Metre mtr depth along with laying of 120 mm HDPE pipe for track crossing with minimum depth reckoned from bottom of the rail/road crossing with minimum depth reckoned from ground level. The work shall be done as per extant pracrice & instructions of site engineer. Preperation of site for Horizontal boring shall be carried out in presence of Railway representative. HDPE pipe will be supplied by Railways. Note_ Contractor shall provide all material required for boring and adequate Nos of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
Where ever depth of 0.5 m cable trench is not cum feasible cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.
Cutting of all types of Roads/ platforms cum preparatory to trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes in trenches.
Maintenance RDSO/SPN/197/2008 or latest consisting of: (1) Copper bond steel electrode 3 Mtr. long 17 mm dia. with copper bonding thickness of min 250 micron & UL listed & marked-01 No. (2) Earth Enhance compound RDSO approved in sealed bag of 10 Kg-03 Nos. (3) Copper strip 150 x 25 x 6 mm-02 Nos. (4) Copper strip 300 x 25 x 6 mm-01 No. (5) 35 Sq.mm copper cable to connect earth electrode to MEEB-15 Mtr. approximately. (Inspection by RDSO)
Installation RDSO/SPN/197/Ver 1 or latest, to construct earthing of </= 1 Ohm consisting of: a) Digging the earth to required depth, insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the equipment room, exothermic weld material and tools & fixtures for the welding copper tapes and electrodes etc. shall be arranged by the contractor. Total 12245668.66
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .