Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC AOC | |
| 2 | L2₹31.9 L+₹51,500 (1.64%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹33.2 L+₹1.8 L (5.69%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹33.9 L+₹2.6 L (8.14%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹35.4 L+₹4.0 L (12.9%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | YS CONSTRUCTION L9 | Bharat Sales Corporation L5 | M/S DARSHAN ENGINEERING WORKS L7 | DEO Traders L2 | M/S G S Gupta and Sons L3 | UNITED ENGINEERING CORPORATION L1 | Himanshu Construction and Suppliers L6 | SUSHMANAND ENGINEERING WORKS L4 | Vee Key Enterprises L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and Labour for Taking down carefully window/ split type Air Conditioner Water Cooler and Refrigerator any Type or cap remote from site and deposited to MES Store Yard complete all as specified and directed. | 50 | Each | 2,500 ₹1,25,000 | 200 ₹10,000 | 500 ₹25,000 | 500 ₹25,000 | 400 ₹20,000 | 300 ₹15,000 | 300 ₹15,000 | 102 ₹5,100 Lowest | 1,000 ₹50,000 |
| 2.00 | Material and Labour for Taking down carefully Voltage Stablizer any type or cap,remove from site and deposited to MES Store Yard complete all as specified and directed. | 32 | Each | 500 ₹16,000 | 100 ₹3,200 | 500 ₹16,000 | 200 ₹6,400 | 200 ₹6,400 | 300 ₹9,600 | 300 ₹9,600 | 98 ₹3,136 Lowest | 500 ₹16,000 |
| 3.00 | Supply and Fix Voltage stabilizer for Automatic Operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stablized at 230 volt with accuracy of +- 2.5% and of capacity 5 KVA complete all as specified and directed. | 28 | Each | 15,000 ₹4,20,000 | 3,800 ₹1,06,400 | 10,500 ₹2,94,000 | 8,000 ₹2,24,000 | 6,000 ₹1,68,000 | 3,250 ₹91,000 Lowest | 10,500 ₹2,94,000 | 5,455 ₹1,52,740 | 12,000 ₹3,36,000 |
| 4.00 | All as per item No 3 above but capacity 4 KVA complete all as specified and directed. | 4 | Each | 12,000 ₹48,000 | 3,000 ₹12,000 Lowest | 10,000 ₹40,000 | 7,000 ₹28,000 | 5,500 ₹22,000 | 3,100 ₹12,400 | 9,500 ₹38,000 | 5,220 ₹20,880 | 10,000 ₹40,000 |
| 5.00 | Supply, install, testing & commissioning of split type air conditioner, Indoor/Outdoor Unit, 240 volts, 50 Hz AC supply with cordless remote control unit, built-in air ionizer and plasma filter for better air quality with inverter technology with 5 Star rating of capacity 1.5 TR including cutting, bending, brazing, insulation on pipe etc, PVC drain pipe, electric connection with suitable size PVC insulated, multi-stranded copper cable complete all as specified and directed.
[Note: (i)All connected pipes shall be concealed with casing and capping and the PVC drain pipe shall be taken to ground level. The rate quoted shall include for these provisions]
(ii) The said AC will be installed Existing/New Location as directed by Engr-in-charge. | 4 | Each | 52,000 ₹2,08,000 | 55,500 ₹2,22,000 | 60,000 ₹2,40,000 | 65,000 ₹2,60,000 | 57,000 ₹2,28,000 | 45,000 ₹1,80,000 Lowest | 62,000 ₹2,48,000 | 57,850 ₹2,31,400 | 68,000 ₹2,72,000 |
| 6.00 | Supply, install, testing & commissioning of split type air conditioner, Indoor/Outdoor Unit, 240 volts, 50 Hz AC supply with cordless remote control unit, built-in air ionizer and plasma filter for better air quality with inverter technology with 5 Star rating of capacity 2.0 TR including cutting, bending, brazing, insulation on pipe etc, PVC drain pipe, electric connection with suitable size PVC insulated, multi-stranded copper cable complete all as specified and directed.
[Note: (i)All connected pipes shall be concealed with casing and capping and the PVC drain pipe shall be taken to ground level. The rate quoted shall include for these provisions]
(ii) The said AC will be installed Existing/New Location as directed by Engr-in-charge. | 28 | Each | 75,000 ₹21,00,000 | 68,000 ₹19,04,000 | 70,000 ₹19,60,000 | 70,000 ₹19,60,000 | 65,000 ₹18,20,000 | 58,500 ₹16,38,000 Lowest | 72,000 ₹20,16,000 | 67,800 ₹18,98,400 | 75,000 ₹21,00,000 |
| 7.00 | M&L for single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one MCB 25 Amps, 240 Volts complete all as specified and directed. | 32 | Each | 1,800 ₹57,600 | 600 ₹19,200 | 900 ₹28,800 | 500 ₹16,000 Lowest | 850 ₹27,200 | 1,150 ₹36,800 | 1,000 ₹32,000 | 790 ₹25,280 | 1,000 ₹32,000 |
| 8.00 | M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 6 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade 25 mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. | 480 | RM | 800 ₹3,84,000 | 300 ₹1,44,000 | 290 ₹1,39,200 | 400 ₹1,92,000 | 220 ₹1,05,600 Lowest | 410 ₹1,96,800 | 300 ₹1,44,000 | 255 ₹1,22,400 | 320 ₹1,53,600 |
| 9.00 | S&F water cooler electric driven (single phase) 230 volt, having appx storage capcity of 180 Ltr and nominal cooling capacity of 150 Ltr per Hour complete all as specified and directed. | 3 | Each | 45,000 ₹1,35,000 | 90,000 ₹2,70,000 | 70,000 ₹2,10,000 | 32,000 ₹96,000 Lowest | 65,000 ₹1,95,000 | 67,500 ₹2,02,500 | 68,000 ₹2,04,000 | 65,000 ₹1,95,000 | 75,000 ₹2,25,000 |
| 10.00 | S&F water cooler electric driven (single phase), having appx storage capcity of 80 Ltr and nominal cooling capacity of 40 Ltr per Hour complete all as specified and directed. | 13 | Each | 38,000 ₹4,94,000 | 42,000 ₹5,46,000 | 48,000 ₹6,24,000 | 22,000 ₹2,86,000 Lowest | 42,000 ₹5,46,000 | 38,500 ₹5,00,500 | 48,000 ₹6,24,000 | 43,500 ₹5,65,500 | 50,000 ₹6,50,000 |
Tender Value
₹31.0 L
EMD Value
₹62,000
Closing Date
17 Feb 2026, 6:00 pmClosed
Lt Col, Vikramjeet Singh Reen
GE I Kanpur Cariappa Road Cantt Kanpur 208004
SPL REPAIR AGAINST BER ACs/WATER COOLER AND REFRIGERATOR AT COD KANPUR UNDER GE (I) KANPUR AT KANPUR CANTT
2026_MES_750049_1
GE(I)/KAN/T-102 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹62,000
Yes
25 Jun 2026
27 Jan 2026
24 Feb 2026
27 Jan 2026
17 Feb 2026
10 Feb 2026
Material and Labour for Taking down carefully window/ split type Air Conditioner Water Cooler and Refrigerator any Type or cap remote from site and deposited to MES Store Yard complete all as specified and directed.
Material and Labour for Taking down carefully Voltage Stablizer any type or cap,remove from site and deposited to MES Store Yard complete all as specified and directed.
Supply and Fix Voltage stabilizer for Automatic Operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stablized at 230 volt with accuracy of +- 2.5% and of capacity 5 KVA complete all as specified and directed.
All as per item No 3 above but capacity 4 KVA complete all as specified and directed.
Supply, install, testing & commissioning of split type air conditioner, Indoor/Outdoor Unit, 240 volts, 50 Hz AC supply with cordless remote control unit, built-in air ionizer and plasma filter for better air quality with inverter technology with 5 Star rating of capacity 1.5 TR including cutting, bending, brazing, insulation on pipe etc, PVC drain pipe, electric connection with suitable size PVC insulated, multi-stranded copper cable complete all as specified and directed. [Note: (i)All connected pipes shall be concealed with casing and capping and the PVC drain pipe shall be taken to ground level. The rate quoted shall include for these provisions] (ii) The said AC will be installed Existing/New Location as directed by Engr-in-charge.
Supply, install, testing & commissioning of split type air conditioner, Indoor/Outdoor Unit, 240 volts, 50 Hz AC supply with cordless remote control unit, built-in air ionizer and plasma filter for better air quality with inverter technology with 5 Star rating of capacity 2.0 TR including cutting, bending, brazing, insulation on pipe etc, PVC drain pipe, electric connection with suitable size PVC insulated, multi-stranded copper cable complete all as specified and directed. [Note: (i)All connected pipes shall be concealed with casing and capping and the PVC drain pipe shall be taken to ground level. The rate quoted shall include for these provisions] (ii) The said AC will be installed Existing/New Location as directed by Engr-in-charge.
M&L for single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one MCB 25 Amps, 240 Volts complete all as specified and directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 6 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade 25 mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
S&F water cooler electric driven (single phase) 230 volt, having appx storage capcity of 180 Ltr and nominal cooling capacity of 150 Ltr per Hour complete all as specified and directed.
S&F water cooler electric driven (single phase), having appx storage capcity of 80 Ltr and nominal cooling capacity of 40 Ltr per Hour complete all as specified and directed.
Supply and fix refrigrator, electric driven (single phase), 230 volt of capacity 310 Ltrs BEE 5 Star rated complete all as specified and directed.
Supply and fix annealed copper tubing of size 1/2'' heavy duty ISI marked complete all as specified and directed.
Supply and fix annealed copper tubing of size 1/4'' heavy duty ISI marked complete all as specified and directed.
Supply and Fixing of foamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed.
Supply and Fixing of foamed polythene insulating pipe of 8 mm internal dia and7 mm wall thickness complete all as specified and directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderdocumentsT102.pdf
Tender Documents • 0.97 MB
BOQ_840045.xls
BOQ • 2.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .