Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹48.1 L+₹1.2 L (2.45%)Rejected-AOC OLD DAILY MARKET DIMAPUR 797 112 NAGALAND | PEREN | NAGALAND | 797112 | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹48.6 L+₹1.6 L (3.50%)Rejected-AOC | L3 | Rejected-AOC Higher bid value | |
| 4 | L4₹48.8 L+₹1.8 L (3.90%)Rejected-AOC | L4 | Rejected-AOC Higher bid value | |
| 5 | L5₹49.3 L+₹2.3 L (4.89%)Rejected-AOC | L5 | Rejected-AOC Higher bid value |
Tender Value
₹46.7 L
EMD Value
₹93,460
Closing Date
16 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
PROVN OF TOILET BLOCK FOR OFFRS JCO OR IN C ZONE NEAR BLDG NO P 111 IN A ZONE PROVN OF COVERED SHED FOR COOK HOUSE OF FRW IN I ZONE PROVN OF INTERLOCKING TILES IN FRONT OF BLDG NO P 716 IN A ZONE PROVN OF MAIN GATE FOR STN MASJID ADDN ALTN TO BLD
2024_MES_662259_2
8753/C/E8
Open Tender
Civil Works
Item Rate
180 days
RANGAPAHAR
Class D, Category a(I)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹93,460
24 Sept 2024
3 Sept 2024
18 Sept 2024
3 Sept 2024
16 Sept 2024
10 Sept 2024
3 Sept 2024 - 7 Sept 2024
Amount
M&L for surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil etc complete all as specified & directed by Engr-in-Charge.
M&L for excavation in trenches n.exc 1.5m wide and n.exc 1.5m in deepth; for foundation etc or for shafts, wells, cesspits, manhole, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified & directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 (using 40mm graded agg) as in foundation, filling and mass concrete etc complete all as specified & directed by Engr-in-Charge.
M&L for RCC Nominal Mix Type A-1 (1:1.5:3) (using 20 mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified & directed by Engr-in-Charge.
M&L for RCC Nominal Mix Type A-1 (1:1.5:3) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified & directed by Engr-in-Charge.
M&L for RCC Nominal Mix Type A-1 (1:1.5:3) (using 20 mm graded stone aggregate) as in beams, cantilvers, bressummers, lintels over 1.5m span etc complete all as specified & directed by Engr-in-Charge.
Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc complete all as specified & directed by Engr-in-Charge.
Use and waste of formwork to chajjas, troughts and similar items including edges etc complete all as specified & directed by Engr-in-Charge.
Form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping) etc complete all as specified & directed by Engr-in-Charge.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified & directed by Engr-in-Charge.
All same as per item No 10 (here-in-before) but 5mm dia and over and including 10mm dia in stirrups spacers and binders etc complete all as specified & directed by Engr-in-Charge.
M&L for brick work with sub class `B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 etc complete all as specified & directed by Engr-in-Charge.
M&L for brick work with sub class `B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 etc complete all as specified & directed by Engr-in-Charge.
S&F Solid PVC Door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube,supplying and fixing in opening as per specification and drawing etc complete all as specified & directed by Engr-in-Charge.
Material and labour factory made solid panel PVC door shutter, 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles plain colour PVC sheets for top rail, lock rail and bootom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame, welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site with three nos of MS higes medium grade etc complete all as specified & directed by Engr-in-Charge.
S&F SS butt hings medium weight cold rolled 100mm size etc complete all as specified & directed by Engr-in-Charge.
S&F 150 mm long aluminium anodised tower bolts etc complete all as specified & directed by Engr-in-Charge.
S&F 100mm long aluminium anodised handles cast copper etc complete all as specified & directed by Engr-in-Charge.
S&F for steel ventilator with top hung shutter including hinges steel peg stay, complete all as specified and directed etc complete all as specified & directed by Engr-in-Charge.
M & L sheet glass, obscured or frosted 3mm thick and glazing with oil putty in squares. nexc 0.5 Sqm each etc complete all as specified & directed by Engr-in-Charge.
M&L for sand filling under floor well ramming including watering as required Spreading & leveling in layers n.exc. 25cm thick etc complete all as specified & directed by Engr-in-Charge.
M&L for hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface etc complete all as specified & directed by Engr-in-Charge.
M&L PCC 1:4:8 type D-2 75mm thick (using graded stone aggregates as in sub base of floor etc complete all as specified & directed by Engr-in-Charge.
M&L for Non skid ceramic colour tiles of 7 to 8mm thick light colour (Square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified & directed by Engr-in-Charge..
M&L for Glazed ceramic colour tiles in vertical surface 300x300x7mm / 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles laid over and including 10mm thick CM (1:4) backing coat etc complete all as specified & directed by Engr-in-Charge.
M&L for 75 mm thick PCC (1:3:6) type C-2 , using 40 mm graded agg in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) etc complete all as specified & directed by Engr-in-Charge.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified & directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering & well ramming in layer s not exc 25 cm etc complete all as specified & directed by Engr-in-Charge.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS – 1161 – 1979 grade St – 240 etc complete all as specified & directed by Engr-in-Charge.
S&F Plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment of Fe-410-W (Gde-E-250 quality-A) etc complete all as specified & directed by Engr-in-Charge.
S&F bands, straps or stays , plain angle cleat or flat iron cleat or securing purlins to wood trusses or rafters, knee piece and similar small articles etc conforming to Fe-290 Gde E-165 etc complete all as specified & directed by Engr-in-Charge.
S & F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws etc complete all as specified & directed by Engr-in-Charge.
S & F Pre-painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws etc complete all as specified & directed by Engr-in-Charge.
S & F for 4 mm thick of size 600x600mm HPSC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic to be fixed or laid/inserted to timber/GI/Aluminium frame work with screws, fixed in ceiling flat or sloping etc complete all as specified & directed by Engr-in-Charge.
S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre etc complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new steel surface of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a red oxide primer etc complete all as specified & directed by Engr-in-Charge.
M&L for rendering 10mm thick plaster in CM 1:6 on fair faces of brick or concrete work finished the surface even and smooth without using extra cement etc complete all as specified & directed by Engr-in-Charge.
M & L rendering 15mm thick on cement mortar on 1:4 brick or concrete work finished the surface even and smooth without using extra cement etc complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer etc complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new wall surface and applying two coats of cement base paint on walls. etc complete all as specified & directed by Engr-in-Charge
S&F 20mm bore GI water tubing medium grade laid in floors or fixed in wall with GI fittings etc complete all as specified & directed by Engr-in-Charge.
S&F15mm bore GI water tubing medium grade laid in floors or fixed in wall with GI fittings etc complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR) 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floor etc complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR) 110mm dia bends in any radius etc complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR) 110mm dia junction single T equal or un equal with an floor etc complete all as specified & directed by Engr-in-Charge.
S&F of PVC (SWR) 75 mm dia pipe as per specification etc complete all as specified & directed by Engr-in-Charge.
S&F of PVC (SWR) 75 mm dia vent cowl pipe as per specification etc complete all as specified & directed by Engr-in-Charge.
M & L for 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls etc complete all as specified & directed by Engr-in-Charge.
S & F 75mm bore PVC (SWR) bends any radius etc complete all as specified & directed by Engr-in-Charge.
M & L Vitreous china ware wash down water closet pan (EWC), pedestal pattern coloured including plastic WC seat black closd pattern eith flat bottom and cover and mild steel chromium plated of aluminised hinging device, complete fiting etc complete all as specified & directed by Engr-in-Charge.
S&F 15mm bore bib tape cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferruleetc complete all as specified & directed by Engr-in-Charge.
S&F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as specified & directed by Engr-in-Charge.
S&F 15mm bore angle stop cock, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe etc complete all as specified & directed by Engr-in-Charge.
S&F PVC low level flushing cistern 10 ltr capacity syphonic action type white body with MS bracket , inlet ball valve, float handle and flush pipe (for EWC or WC) etc complete all as specified & directed by Engr-in-Charge.
S&F for PVC Connection pipe 15mm size with PTMT nuts of length 450 mm etc complete all as specified & directed by Engr-in-Charge.
M&L for vitreous china squatting pan, Orissa, pattern size 580 x 440 mm white with integral foot rests(excluding flushing cistern and flush pipe)including connection to trap and to flushing pipe, anti-syphonage pipe etc complete including making good to floor etc complete all as specified & directed by Engr-in-Charge.
S&F vitreous china wash basin, size 550 x 400mm white including brackets, and waste coupling & pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement etc including waste pipe, CI bracket, CP fency pillar tap 155mm bore etc complete all as specified & directed by Engr-in-Charge.
S&F toilet paper holder, coloured vitreous china, box type fixed in wall etc complete all as specified & directed by Engr-in-Charge.
S&F soap dish, vitreous china white, aprox size 160 X 160 X 90 mm. fixed to plugs with chromium plated brass screws etc complete all as specified & directed by Engr-in-Charge.
S&F Glass shelves, with 12mm thick desher glass incl CP brackets with brass nuts 300 mm long etc complete all as specified & directed by Engr-in-Charge.
S&F mirror of size 450x600x5mm thick with aluminium frame and mounted on 6mm ply confirming to IS, with two Nos of hanging hooks fixed etc complete all as specified & directed by Engr-in-Charge.
S&F CP towel rail 600mm long with brackets, aluminium anodised 20mm dia etc complete all as specified & directed by Engr-in-Charge.
S&F CP grating 100mm dia PTMT with waste hole etc complete all as specified & directed by Engr-in-Charge.
S&F CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and directed for WC (Make - SONA/ADSON/ ESSCO) etc complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR) floor trap plain with grating including jointing with solvent cement etc complete all as specified & directed by Engr-in-Charge.
S&F for vitrious china urinal, half stall type, white including flushing cistern, flush pipe and waste pipe. CP waste coupling etc complete all as specified & directed by Engr-in-Charge.
M & L for precast cement concrete1:2:4 type B-1 using 20 mm stone aggregate as in manhole cover slabs round square or rectangular in shape and set in CM 1:4 etc complete all as specified & directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C-2 (40mm grade stone aggregate) as in bed to 110 mm dia SGSW /PVC pipes including packing under and haunching against the sides of pipes after they are laid and tested etc complete all as specified & directed by Engr-in-Charge.
S&F rotational moulded polyethylene 1000 Ltrs Capacity water storage tanks double layer (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia etc complete all as specified & directed by Engr-in-Charge.
S&F for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5 cm but n exc 30cm long and 16 to 20mm dia of neck etc complete all as specified & directed by Engr-in-Charge.
S&F Aluminium handle cast type anodised 150 mm long etc complete all as specified & directed by Engr-in-Charge.
M&L for PCC 1:4:8,type D-2 using 40mm graded crushed stone aggregate as in sub base 100 mm thick etc complete all as specified & directed by Engr-in-Charge.
M&L for 60mm thick machine pressed precast concrete interlocking paver block coloured with grey cement and no pigment of any shape and size confirming to IS 15658-2006 of M-35 grade laid over and incl 50 mm thick sand cushioning etc complete all as specified & directed by Engr-in-Charge.
M&L Plain cement concrete 1:2:4, type B-1( using 20mm graded crushed stone aggregate ) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work etc complete all as specified & directed by Engr-in-Charge.
Dismantling structural steel work in?cluding doors, gates but excluding framed truss etc complete all as specified & directed by Engr-in-Charge.
Demolition of Reinforced cement Concrete of any description and in any position not otherwise specifically provided etc complete all as specified & directed by Engr-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressedstonework and pre cast concrete articles etc complete all as specified & directed by Engr-in-Charge.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified & directed by Engr-in-Charge.
Dismantaling of Stone slabs and tiles laid bedded or pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified & directed by Engr-in-Charge.
Disamantling wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness including cover fillets etc complete all as specified & directed by Engr-in-Charge.
Demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing etc complete all as specified & directed by Engr-in-Charge.
Supply only Integral water proofing compound etc complete all as specified & directed by Engr-in-Charge.
Dismantling timber scantlings unframed work 40 sqcm and over in section in any position etc complete all as specified & directed by Engr-in-Charge.
Taking down shutter of any description exceeding 1.0 Sqm nexc 2Sqm each etc complete all as specified & directed by Engr-in-Charge.
Dismantaling of wrought iron or mild steel work of any description not other wise provided etc complete all as specified & directed by Engr-in-Charge.
Dismantaling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified & directed by Engr-in-Charge.
M&L for reinforced cement concrete nominal Mix (1:1.5:3) type A-1 using 20 mm graded aggrigate in Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete etc complete all as specified & directed by Engr-in-Charge.
M&L for reinforced cement concrete nominal Mix (1:1.5:3) type A-1 using 20 mm graded stone aggregates Columns ,pillers , Piers Post & strut etc complete all as specified & directed by Engr-in-Charge.
M&L for reinforced cement concrete nominal Mix (1:1.5:3) type A-1 using 12.5 mm graded aggregates in Dome voult shell roof arch ribs and folded plate etc complete all as specified & directed by Engr-in-Charge.
Use & waste of form work for sides of concrete foundation footing bases of column ,plinth beam and similar work flat rough finished surfaces of concrete etc complete all as specified & directed by Engr-in-Charge.
Use & waste of form work for sides of piller , posts struts,piers columns etc complete all as specified & directed by Engr-in-Charge.
Use & waste of form work for sides and soffit of dome voult shell arches courved in two plane etc complete all as specified & directed by Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard dence soil etc complete all as specified & directed by Engr-in-Charge.
S&F 2 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified & directed by Engr-in-Charge.
M&L for Rendering 10 mm thick CM 1 : 4 on other then fair faces of brick work or concrete surfaces and finished even and smooth with out using extra cement etc complete all as specified & directed by Engr-in-Charge.
M&L for Rendering 5 mm thick CM 1 : 3 on fair faces of brick work or concrete surfaces and finished even and smooth with out using extra cement as in cellings etc complete all as specified & directed by Engr-in-Charge.
M & L for 100 mm thick Cement concrete type B- 2,(1:2:4) using (40mm graded stone aggregate) etc complete all as specified & directed by Engr-in-Charge.
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete pointed in white or coloured cement to match in vertical surfaces etc complete all as specified & directed by Engr-in-Charge.
M&L for two coats of white wash in walls including preparing new surfaces plastered or un plastered etc complete all as specified & directed by Engr-in-Charge.
S & F Fe 410 w (Gde E -250 quality only) Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing etc complete all as specified & directed by Engr-in-Charge.
M & L for preparation of new surfaces and applying one coat of primer etc complete all as specified & directed by Engr-in-Charge.
M & L for preparation of surface two coats of weather proof exterior emulsion paint on brick / concrete surfaces or plastered surfaces etc complete all as specified & directed by Engr-in-Charge.
S&F 150mm bore salt glazed stone ware pipe Grade ‘A’ as in trenches at any depth complete all as specified (Excavation , earth work & concrete shall be measured and paid separately) etc complete all as specified & directed by Engr-in-Charge.
M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate , concrete bed to drains laid to falls in trenches in any depath inl. Packing under and haunching against the sides of SGSW pipes 150mm bore after the pipes have been laid jointed and tested etc complete all as specified & directed by Engr-in-Charge.
M&L for Brick work with sub class ‘B’ bricks, old size straight or curved on plan exceeding 6.00 metre mean radius in cement mortar (1:4) including corbelling and arches where shown on drawings etc complete all as specified & directed by Engr-in-Charge.
PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in benching for manholes, bands , coping , bed plate etc with slightly chamfered or rounded angles including necessary form work, if any, and finishing exposed surface even and smooth without using extra cement etc complete all as specified & directed by Engr-in-Charge.
M&L for Extra for forming fair finish to drain or channel 30cm internal girth in cement concrete using extra cement inl. forms moulds/mitred stopped ends etc complete all as specified & directed by Engr-in-Charge.
Form work to edges of concrete slabs exc 10 cm but not exc 20 cm thick etc complete all as specified & directed by Engr-in-Charge.
S&F roof Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes and painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop before fabricationetc complete all as specified & directed by Engr-in-Charge.
M&L for Rendering 12mm thick in cement mortar 1:4 on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement etc complete all as specified & directed by Engr-in-Charge.
M&L for Rendering 12mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement etc complete all as specified & directed by Engr-in-Charge..
M&L for PCC 1:4:8 type D-2 150mm thick (40mm thick stone agg) as in sub base of floor etc complete all as specified & directed by Engr-in-Charge.
S&F 125mm long aluminium handles, cast type anodised fixed to doors etc complete all as specified & directed by Engr-in-Charge.
S&F Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture not more than 1.18 mm and fixed with tinned tacks or galvanized wire staples etc complete all as specified & directed by Engr-in-Charge.
S&F 100 mm cast iron soil waste and vent pipe in any length with or without ears laid in floor./trenches etc complete all as specified & directed by Engr-in-Charge.
S & F 75mm cast iron pipe with or with out ears,with cement joints laid in trenches/walls etc complete all as specified & directed by Engr-in-Charge.
S&F 100 mm cast iron bend etc complete all as specified & directed by Engr-in-Charge.
S&F 100 mm cast iron door bend with access door reducer for connecting pipes complete all as specified etc complete all as specified & directed by Engr-in-Charge.
S&F branch pieces single 100mm dia (equal or unequal) ordinary or inverted etc complete all as specified & directed by Engr-in-Charge.
S&F 75 mm CI nahani trap , with grating inl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) etc complete all as specified & directed by Engr-in-Charge.
S&F 100 mm CI floor trap , with grating include. jointing to waste pipe fixed in cement concrete type B1 (1:2:4) etc complete all as specified & directed by Engr-in-Charge.
M&L Salt-glazed stoneware gully traps 150/100 mm, setting and jointing with solvent cement with outlet pipes and PCC 1:2:4 filling around trap and 25mm thick coverslab (size as directed by EIC) etc complete all as specified & directed by Engr-in-Charge.
S&F Vitreous china Urinal, bowl type, coloured ,flush pipe and waste pipe including providing and fixing plugs, bedding urinal against wall in cm 1:2 securing urinal to plugs fixing with brackets,flush pipe,grating and union for 32mm dia PVC pipe discharge pipe connection to drain including urinal spreader chrome platedetc complete all as specified & directed by Engr-in-Charge.
M&L Soap shelf, PVC white/colour appx size 450 x 125 x 40mm (as per sample). Make: Prayag or equivalent as approved by GE etc complete all as specified & directed by Engr-in-Charge.
S&F Bib taps,CP, fancy type screwed for 15mm bore of iron pipe or for brass ferrule and fixed etc complete all as specified & directed by Engr-in-Charge.
S&F Stop valves, fancy type, CP with long shank and cup ( concealed typee ), screwed both ends for 15mm bore of iron pipe or for union and fixed etc complete all as specified & directed by Engr-in-Charge.
S&F Stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 20mm bore of iron pipe or for union and fixed etc complete all as specified & directed by Engr-in-Charge.
S&F 450mm long MS powder coated peg set of 5 or 6 including removal of wooden pegs etc complete all as specified & directed by Engr-in-Charge.
S&F of rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top) 500 Ltr capesity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe etc complete all as specified & directed by Engr-in-Charge.
Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames etc complete all as specified & directed by Engr-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding etc complete all as specified & directed by Engr-in-Charge.
S&F framed brackets of angles or tees with web and flanges cut to shape drilled and countersunk for screws, including bending and welding angles, as necessary, gusset plates, riveting, etc n exc 10 kg each brackets, conforming to Fe- 290. Gde -E-165 etc complete all as specified & directed by Engr-in-Charge.
M&L 40 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) as damp proof course to horizontal or vertical surfaces including necessary form works, applying evenly a coat of blown type bitumen at 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm including 150 micron thick polythene film laid over a coat of bitumen primer @ 0.30 to 0.50 kg per sqm etc complete all as specified & directed by Engr-in-Charge.
M&L 100mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in sub base of floor etc complete all as specified & directed by Engr-in-Charge.
S&F Non skid ceramic colour tiles of 7 to 8mm thick light colour (Square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified & directed by Engr-in-Charge.
All as per item No 135.00 (here-in-before) but in skirting including 10mm thick plastering for backing coat in cement mortar 1:4 etc complete all as specified & directed by Engr-in-Charge.
S&F Non skid ceramic colour tiles of 7 to 8mm thick light colour (Square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified & directed by Engr-in-Charge.
M&L, providing Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in floor and set and jointed in neat cement slurry and pointed with grey cement to match the stone floor/steps treads over 20mm thick screed bed in CM 1:3 etc complete all as specified & directed by Engr-in-Charge.
M&L, providing Kota stone slab 20 to 25mm thick machine cut and mirror polished to size and fixed in wall and set and jointed in neat cement slurry and pointed with grey cement to match the stone over and including 10 mm thick rendering in CM 1:4 for laying in vertical surfaces etc complete all as specified & directed by Engr-in-Charge.
M & L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails 2nd class hard wood exc 13 and n.exc 25 sqcm etc complete all as specified & directed by Engr-in-Charge.
Material & labour 2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints etc complete all as specified & directed by Engr-in-Charge.
M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified & directed by Engr-in-Charge.
M & L for Pressed steel frames of size 125x60mm (1.25mm thick MS sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,including one shop coat of primer complete as specified, supplied and fixed etc complete all as specified & directed by Engr-in-Charge.
M&L for 35 mm thick 2nd class hardwood, factory made plain framed pannelled shutter (any number of panels) with panels of timber flat on both sides or of veneered particle board medium density , wood particle board with commercial face veneers , supplied and fitted to chowkats cetc complete all as specified & directed by Engr-in-Charge.
S &F 35mm thick 2nd class hardwood, factory made glazed and skeleton shutters open rebated and prepared to receive glass gauze etc divided into squares, with plain, chamfered or rounded mitred and rebated sash bars any number edges of framing plain, chamfered or rounded, fitted with cut and metered beads for securing glass etc size of members of shutters as specified in SSR Part I Sec 8 clause 8.23 (a) etc complete all as specified & directed by Engr-in-Charge.
S&F 30 mm thick 2nd hardwood, factory made glazed and skeleton window and ventilator shutters, open rebated and prepared to receive glass, gauze, etc. ( with and without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beeds for securing glass etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (b); supplied and fitted to chowkats etc complete all as specified & directed by Engr-in-Charge.
M & L for 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each etc complete all as specified & directed by Engr-in-Charge.
S & F 75 size stainless steel butt hinges etc complete all as specified & directed by Engr-in-Charge.
S & F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed etc complete all as specified & directed by Engr-in-Charge.
S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed etc complete all as specified & directed by Engr-in-Charge.
S&F mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified & directed by Engr-in-Charge.
S & F floor door stopper of aluminium alloy body and tongue, anodised wit hard drawn steel spring, fixed in floor, overall length of cover plate 150mm etc complete all as specified & directed by Engr-in-Charge.
Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar etc complete all as specified & directed by Engr-in-Charge.
M&L for rendering 15mm thick plaster in CM 1:6 on fair faces of brick or concrete work finished the surface even and smooth without using extra cement etc complete all as specified & directed by Engr-in-Charge.
Material and labour for preparation of new external surfaces of walls including cornices, plasters etc (Plastered or un plastered surfaces) and applying two coats of cement paint over one coat of primer complete all as per manufacture instructions etc complete all as specified & directed by Engr-in-Charge.
Taking up or down steel tubing 15mm bore and connection including cleaning for refixing or removal to store etc complete all as specified & directed by Engr-in-Charge.
All as per item No 156.00 (here-in-before) but 20mm dia etc complete all as specified & directed by Engr-in-Charge.
M & L for angular stop cock CP with wall flange, fancy type 15 mm bore dia etc complete all as specified & directed by Engr-in-Charge.
M&L for Chequered cement concrete tiles 25mm thick,set, jointed with grey cement and pigment and pointed in neat cement slurry in floors over 15 mm thick screed bed in CM 1:6 etc complete all as specified & directed by Engr-in-Charge.
S & F for Draperly rod/Harrison rails of CP of 20 mm dia with fixing brackets, Stops rollers and rings etc complete all as specified & directed by Engr-in-Charge.
M&L Plain cement concrete (1:2:4), type B-1( using 20mm graded crushed stone aggregate ) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level complete all as specified and as directed.
Dismantling timber scantlings 40 sqcm and over in section, in unframed work any position complete all as specified and as directed.
M&L for applying two coats of oil bound distemper on new plastered surfaces of walls over a coat of 3mm thick wall care putty incl preparation of surface complete all as specified and directed
M&L Cement concrete (1:3:6) type C-1 (using 20 mm graded stone agg ) in surface channels and drains complete all as specified and as directed.
S&F .63 mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
M& L for Preparation of new wall surfaces and applying Three coat white wash complete all as specified and as directed.
M&L for PCC (1:2:4) type B-2 100mm thick (using 20mm graded stone agg) as in finishing surfaces of concrete topping even and fair (without using extra cement) of floor complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 75mm thick (using 40mm thick graded stone agg) as in sub base of floor complete all as specified and as directed.
S & F for 10-15mm thick Endura tiles laid and jointed with grey cement slurry mixed with pigment in floor to match the shade of the tiles laid over and including 15 mm thick screed bed in CM (1:6) etc complete all as specified and as directed.
Excavation over areas not exc 1.5 m deep in soft soil and getting out complete all as specified and as directed.
All as per item No 171.00 (here-in-before) but depth 1.5 m to 3 m complete all as specified and as directed.
All as per item No 171.00 (here-in-before) but depth 3 m to 4 m complete all as specified and as directed.
M&L Brickwork with sub-class `B' bricks (using old size burnt bricks) in one brick thick honeycomb walling built in cm 1:4 complete all as specified and as directed.
M&L for Loose filling with broken bricks of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified and as directed.
M&L for bib cock CP with wall flange , fancy type 15 mm dia bore etc complete all as specified and as directed.
S&F 100 mm long aluminium hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised fixed to doors etc complete all as specified and as directed.
S&F mild steel box type ventilator fixed type complete with sash bars dovetailed or welded and with shop coat of zinc chromate primer ready for wire mesh/glass pan fixing etc complete all as specified and as directed.
M&L for Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling, floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surfaceetc complete all as specified & directed by Engr-in-Charge.
M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site etc complete all as specified & directed by Engr-in-Charge.RR Kabel Make of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme
(a) One light Point controlled by one way switch etc complete all as specified & directed by Engr-in-Charge.
(b) One Exhaust fan point controlled by one, one way switch etc complete all as specified & directed by Engr-in-Charge.
(c) One 3 pin socket outlet 5 Amps on the Independent board etc complete all as specified & directed by Engr-in-Charge.
Material and labour for (concelaed Type) point wiring including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessories and sunk modular GI box for mounting of fittings like switch, socket and fan regulator with modular inner plate and cover plate and making good the distrubed surfaces as per the existing etc complete all as specified & directed by Engr-in-Charge.
(a) One light/Fan point controlled by one, one way switch etc complete all as specified & directed by Engr-in-Charge.
All as per item No-182 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly etc complete all as specified & directed by Engr-in-Charge.
M&L for Switch piano flush type single pole, one way 5A etc complete all as specified & directed by Engr-in-Charge. Make:- Havells/Legrand/Anchor
M&L for Switch Socket combination, 2 in 1, 5 pin 5A flush type etc complete all as specified & directed by Engr-in-Charge.Make:- Havells/Legrand/Anchor
M&L Switch socket combination 2 in 1, 5A/16A, 5 in 1 flush type etc complete all as specified & directed by Engr-in-Charge. Make:- Havells/Legrand/Anchor
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body etc complete all as specified & directed by Engr-in-Charge. Make:- Havells/Legrand/Achor
M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting etc complete all as specified & directed by Engr-in-Charge. Make : Crompton Geaves Cat No -CCS-102-20-65-SL-DP-NWH/ Bajaj/ Philips.
S&F for LED light fitting 1 x 10 W (2 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in & incl flexible hose from ceiling rose to fitting etc complete all as specified & directed by Engr-in-Charge.
Supply , fixing and testing in replacement of LED Bldg Security light fitting of capacity 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting etc complete all as specified & directed by Engr-in-Charge.
Supply and fixing Wall mounted fan 400 mm sweep PP Blade and thermal overload protection for long lasting motor power consumation 58 Watt fan motor speed 1330 RPM Air dilivery 85 (CMM) with accessories etc complete all as specified & directed by Engr-in-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m etc complete all as specified & directed by Engr-in-Charge.Make : Havells/Bajaj/CG
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etcall etc complete all as specified & directed by Engr-in-Charge. Make-Havells/Bajaj/Crompton
M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with 200 amps rated bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity of MCB etc complete all as specified & directed by Engr-in-Charge. Make:- Legrand Cat No 607711 or equivalent in ABB/Siemens
M&L for MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs making good the distrubed surfaces of various rating capacity including taking down old unsv DB etc complete all as specified & directed by Engr-in-Charge.
M&L for MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series etc complete all as specified & directed by Engr-in-Charge. Make:- Legrand Cat No 408636 or equivalent in ABB/Siemens
M&L for MCB SP 6-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series etc complete all as specified & directed by Engr-in-Charge. Make:- Legrand Cat No 408587-95 or equivalent in ABB/Siemens
M&L for laying of LT UG cable , XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 6 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items etc complete all as specified & directed by Engr-in-Charge. Make: Havells/Polycab/Phinolex/Richa
All as per item No 198.00 But 16 Sqmm 2 Core etc complete all as specified & directed by Engr-in-Charge.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm etc complete all as specified & directed by Engr-in-Charge.
Supply & laying tubes ' Light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 25 mm dia bore etc complete all as specified & directed by Engr-in-Charge. Make : Tata/Jindal/Prakash
Supply and laying tubes medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 40mm dia bore GI tubing etc complete all as specified & directed by Engr-in-Charge. Make: Jindal/Prakash surya/TATA
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion etc complete all as specified & directed by Engr-in-Charge. (i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 with 10mm thick CI cover plate hinged to angle iron frame of suitable size, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 441 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 with 10mm thick CI cover plate hinged to angle iron frame of suitable size, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type.
Supply and fixing for Air termination, single pointed aluminium rod 12mm dia and 300mm long etc complete all as specified & directed by Engr-in-Charge.
Supply and fixing of Aluminium strip 25 x 3.15mm with porcelain insulators saddles and fixing screws etc. for roof conductors above ground complete all as specified and as directed. Note: (a) All the roof conductors down conductors and air termination rod shall be mounted on suitable size porcelain insulators/saddles. (b) Any portion of the lightning condcutor, air termination rod and the strip GI/Aluminium are not in contact with the building. (c) The cost of porcelain insulators/saddle with fixing accessories is deemed to be included in quoted rate. (d) Conductor shall be properly secured to the building. (e) Due case taken to avoid leakage/damage in roof of the bldg, repair/replacement cost of the leakage deemed to be included in quoted rate. (f) The lightning condcutor shall be secured at not more than 1.20 mtr apart for horizontal run and 1 mtr for vertical run.
Supply and fixing for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw etc complete all as specified & directed by Engr-in-Charge..
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron strip 32x 6mm as earthind lead by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of required size (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion etc complete all as specified & directed by Engr-in-Charge.
S & F MS Screw bolts machine made with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fited with washers and one hexagonal or square nuts, length of both exc 10cm and n exc 15 cm long dia of neck 11 to 15mm etc complete all as specified & directed by Engr-in-Charge.
S & F MS Screw bolts machine made with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fited with washers and one hexagonal or square nuts, length of both exc 15cm and n exc 22 cm long dia of neck 16 to 20mm etc complete all as specified & directed by Engr-in-Charge.
M/S MUNGA LAL PRASAD (BID ID -3097043)
Gajanand Wooden Furniture House (BID ID -3096593)
Shri Lakhinder Praasd (BID ID -3096910)
SK SINGH (BID ID -3096327)
Shri H Kivigho Zhimo (BID ID -3097069)
MM Dhar Enterprise (BID ID -3096333)
M/S Yhobu Entrepreneur (BID ID -3096721)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .