Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.6 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹34.2 L+₹1.6 L (5.01%)Rejected-Finance | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹35.9 L+₹3.4 L (10.3%)Rejected-Finance | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹37.1 L+₹4.5 L (13.9%)Rejected-Finance 1 AL SHEIKH COMPLEX 1ST FLOOR PEERBAGH CHOWK SRINAGAR PEERBAGH SRINAGAR BUDGAM JAMMU KASHMIR 190014 | BUDGAM | JAMMU AND KASHMIR | 190014 | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹37.9 L+₹5.3 L (16.2%)Rejected-Finance | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹41.7 L
EMD Value
₹83,420
Closing Date
29 Jul 2023, 6:00 pmClosed
GE 861 EWS
GE 861 EWS c/o 56 APO
PROVN OF SENTRY POST MT SHED SLIDING GATE WALL PANELLING CHAIN LINK FENCING AND SEPTIC TANK WITH SOAKAGE WELL AT CERTAIN UNITS OF HQ 2 SECT RR UNDER AGE B R P AND AGE EM OF GE 861 EWS
2023_MES_606290_1
GE 861 EWS-42/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
As per tender documents
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹83,420
Yes
10 Oct 2023
28 Jun 2023
5 Aug 2023
28 Jun 2023
29 Jul 2023
15 Jul 2023
Amount
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in any type of soil, complete all as specified and directed.
All as per srl item No-2 here in above but exc 1.5m & n.exc 3.0m in depth.
Excavation in post holes (or similar holes) each n.exc. 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m, in soft/loose soil and making good surfaces, complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
RCC M-30 design mix using 20 mm graded aggregate in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, etc basements slabs under rammed piles and mass concrete complete all as specified and directed.
RCC M-30 design mix using 20 mm graded aggregate as in beams, cantilevers, bressummers lintels over 1.5 m span complete all as specified and directed.
RCC M-30 design mix using 20 mm graded aggregate in column, pillars, piers, posts and struts complete all as specified and directed.
RCC M-30 design mix using 20 mm graded aggregate as in slab supported on walls, beams and columns in floors, roofs landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Form work to sides of concrete foundations, footings, bases of columns, raft beams sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
Form work to sides and soffits of floor or roof beam haunching , lintels, cantilevers shelved including supports overhangs etc also splays between floors and beams, etc complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finish surface of concrete square, rectangular or polygonal complete all as specified and directed.
Form work to sides and soffits of suspended slab such as roof slab, floor slab, shelves and similar works n. exc. 200 mms thick (Horizontal or sloping), finishing rought the concrete surfaces, complete all as specified and directed.
MS TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed.
MS TMT Bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed.
Hard core of broken stone or boulders of guage exc 63mm but n. exc 100mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:4, complete all as specified and as directed.
Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed.
10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed.
15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement mixied with water proofing compound @ 3% by weight of cement or in the proportion as mentioned in manufacture's instructions complete all as specified.
10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed.
5mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 finished the surface even and smooth without using extra cement, complete all as specified and directed.
Supply only integral water proofing compound of approved quality, complete all as specified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 75mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
75mm thick PCC 1:4:8 Type D-2 (40 mm graded stone aggregate) as in sub-base of floors, complete all as specified and directed.
100mm thick PCC 1:3:6 Type C-2 (40 mm graded stone aggregate) as in sub-base of floors, complete all as specified and directed.
25mm thick PCC 1:2:4, type B-0 (using 12.5 mm graded crused stone aggregate) as in floors to recieve floor finishes, complete all as specified.
Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
80mm thick factory made machine pressed precast concrete coloured interlocking paver block with grey cement and pigment, any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-35 grade, complete all as specified and directed.
60mm thick factory made machine pressed precast concrete coloured interlocking paver block with grey cement and pigment, any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-35 grade, complete all as specified and directed.
Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed.
Rolled mild steel in roof trusses (framed),trussed ,purlins,crane girders,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Rolled sections as in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. in cluding cleats, brackets, etc. complete, conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Mild steel in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; holdfasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
Rolled mild steel in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240, complete all as specified and as directed.
Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410W (Gde E-250) quality-A, complete all as specified and directed.
Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or rivering, etc., and similar work confoming to FE-290 Gde E-165 including taking out old posts of any description all as specified and directed.
4mm dia galvanised steel wire(Chain Link) 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed.
Mild steel bolts n exc 12 mm dia purpose made with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexogonal or square not exc 30 cm long complete all as specified and directed.
Galvanised , 2 strand , steel barbed wire, 2.24 mm dia barbed with 2 mm dia barbs, 75 mm spacing and straining and fixing to any type of standard rails and straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire complete all as directed. Note:(Each line of wire to be measured)
MS round bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
35 mm thick 2nd class hardwood plain (Sal/ Hollock) factory made, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats, complete all as specified and as directed.
2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, worught, framed rebated on the solid, rounded of chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
9mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in walls with nails to timber frame, complete all as specified and directed.
Anodised aluminium snap grid of size 605x 605mm frame work for false ceiling including supporting hangers 6mm dia. G.I. rod (upto 1200mm length) with neccessary bolts, nuts and washers, adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and directed.
6mm thick non asbestos fibre cement building boards fixed or laid/ inserted to aluminium framework with scre, complete all as specified and directed.
8mm thick 600mm x 600mm size decorative designer type pre-painted non asbestos fibre cement building boards fixed or laid/ inserted to aluminium framework with scre, complete all as specified and directed.
2nd class softwood plain fillets square/rectangular or triangular in section of sectional area exc 13 Sqcm but n exc 25 Sqcm, complete all as specified and directed.
2nd class softwood plain fillets bull nosed splayed chamfered or rounded on one edge or face in section of sectional area exc 3 Sqcm but n exc 6 Sqcm, complete all as specified and directed.
2nd class softwood plain fillets bull nosed splayed chamfered or rounded on one edge or face in section of sectional area not exc 3 Sqcm, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour as approved having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
300mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
150mm long, aluminium alloy handles, cast type, anodised, all as specified and directed.
100mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
Galvanised steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm, fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
Construction of on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for for 30 users complete all as specified and directed.
Construction of soakage well, excavation in ordinary soil, foundation PCC 1:3:6 wells of honey combed and solid in M-25 concrete, including intercepting chamber chamber screen chamber, brick work CM 1: 4, RCC cover slab in M-25/ RR masonry filling with brick bats, complete of size 1.80m dia 3.0m deep as shown in drg complete all as specified and directed. Drg No CESZ/TD-01/2015 Sheet 3/3.
200mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars, complete all as specified and directed.
Concrete bed to drain pipes 200mm bore including packing under,and haunching against the sides of pipes after they are laid and treated in cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali-resistant priming coat, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of Oil bound distemper, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces or non asbestos fibre cement boards of ceiling and applying three coats of white wash,complete all as specified and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of new or previously untreated steel surface any description n. exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of surfaces treating ends of posts, backs of chowkats, etc area tarred exc 0.1sqm but n.exc 0.5 sqm each treated with tar or coal tar black paint complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch, complete all as specified and directed.
All as per srl item No-75 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-75 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No-75 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 Amp flush type, universal, complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
Modular one way switch 6 Amp, 1 module, complete all as specified and directed.
Modular one way switch 16A, 1 module, complete all as specified & directed.
Modular socket outlet, 6A-2/3 pin combined 2 module, 230 volts complete all as specified and directed.
Modular socket outlet, 6A/16A-2/3 pin combined 2 module, 230 volts complete all as specified & directed.
Modular white cover plate with frame, 3 module, complete all as specified and directed.
Modular white cover plate with frame, 4 module, complete all as specified and directed.
Modular white cover plate with frame, 6 module, complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
LED lamp 9 W, complete all as specified and directed.
LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
LED street light fitting 35 watt 230 V AC outdoor type with high pressure die-cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, complete all as specified and directed.
LED street light fitting 60 watt 230 V AC outdoor type with high pressure die-cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, complete all as specified and directed.
LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed.
MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 8 ways, IP-43 protection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 200 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts "C" series capacity of 32 Amps, 10kA and making connections, complete all as specified & directed.
MCCB 4 pole, 415 volts fixed type, 63 Amps with breaking capacity 16 KA, complete all as specified and directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor (solid), served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10.0 sqmm, complete all as specified and directed.
1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 sqmm nominal cross section 2.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified.
Supply and laying 40mm dia GI tubing light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
1100 volts grade copper conductor cable two core 1.50 sqmm (flexible), complete all as specified & directed.
Street light junction/pole box of size 250mm x 200mm x 150mm made of 1.6mm thick MS sheet, front side openable with fixing screws, painted with two coats of synthetic enamel paint over a coat of red oxide primer and including 2 Nos aluminium bus bar 20x3mm mounted on epoxy based post insulator and drill holes for cable connection including 01 No MCB SP 6 Amps, fixing on steel tubular pole with MS strip of size 20x3mm with suitable size nuts, bolts and washers, complete all as specified and directed.
Security light brackets with 1.20mtrs long 40mm dia galvanised iron pipe, medium grade with 100°-120° bend including arrangement for fixing at desired location with the help of flat iron clamps made of FI 40mmx5mm, nuts, bolts and washers including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
Steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-31 ( 9 Mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified laying GI pipe light grade for cable protection and fixing to existing pole with flat iron clamp 25x3mm including nuts bolts and washers etc complete of 40mm dia including taking out old unserviceable pole, complete all as specified and directed.
Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC), complete all as specified and directed.
450mm sweep wall fan, high speed, 230 volts,AC single phase, 50 Hz with jerk free, oscillation, smooth running, three blades, pull cords including all fixing arrangement, complete all as specified and directed.
Sub main wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 sqmm as earth lead in & including PVC conduit medium grade not less than 25mm dia ISI marked, complete all as required at site or directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-) 8.0%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
BHAT CONSTRUCTIONS AND BUILFERS
JANDOO AND CO
M/S Sofi Brothers
M/S AK ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .