Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹20.8 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹21.4 L+₹21,583 (1.02%)Rejected-AOC | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹21.6 L+₹39,380.50 (1.86%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹22.3 L+₹1.1 L (5.35%)Rejected-AOC | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹22.4 L+₹1.2 L (5.74%)Rejected-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIRPORT ROAD JAMMU 181101 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181101 | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
4 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
REPAIR TO ROOFING, CEILING, ROOF TREATMENT, PLASTERING, RAIN WATER PIPE, PATH, HARDSTANDING, DRAIN, HUME PIPE, BOUNDARY WALL AND FENCING AT KALUCHAK MIL STN UNDER GE KALUCHAK
2022_MES_536771_1
GE/KC/NIT-29/2022-23
Open Tender
Civil Works
Item Rate
270 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹58,000
Yes
6 Sept 2022
9 Jul 2022
6 Aug 2022
9 Jul 2022
4 Aug 2022
23 Jul 2022
9 Jul 2022 - 16 Jul 2022
Amount
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e. using serviceable bricks obtained from Srl item No. 01 here-in-before, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan to any radius, half brick thick walls built in cement mortar 1:4, complete all as specified & directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces of wall/ceiling, chajjas, roof projections etc upto triple storey etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick in cement mortar 1:3, surface finished even and smooth without using extra cement using liquid water proofing admixture as per manufacturer,s instructions, complete all as specified & directed. Note : Liquid water proofing admixture shall be measured & paid seprately.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces upto triple storey of building, surface finished even and smooth without using extra cement, complete all as specified & directed.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
10mm thick rendering in cement mortar 1:4 on concrete surfaces of ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint, complete all as specified & directed.
Preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer, complete all as specified.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls (upto triple storey building with necessary scaffolding) including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of cement base paint, complete all as specified & directed.
Dismantling structural steel work including doors, gates, framed truss etc., complete all as specified & directed.
Rolled mild steel work in roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-290 grade-E-165, complete all as specified & directed.
Dismantling timber scantling as in fillets, rails, purlins, etc under 40 sq cm in section, in any position, in unframed work, complete all as specified & directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position (framed work), complete all as specified & directed.
2nd class hard wood (Sal/Hollock) as in scantling, clean sawn timber, fixed in framed work, complete all as specified & directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering, complete all as specified & directed.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
6mm thick asbestos cement, corrugated or semi-corrugated sheeting in roof, walls etc., fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
Asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheets 6mm thick fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap, fixed with self taping screws, complete all as specified & directed.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified & directed.
Suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame work for false ceiling, grid size 605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 3mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc , hangers to be fixed with approved rawl plug, level adjusters and screwsa etc, last hanger at the end of each runner shall not be greater than 450mm from adjacent wall all as per manufacturer’s Instructions including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified and directed. Note : All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls with necessary clamps, fixed in repairs, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls with necessary clamps, fixed in repairs, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius, fixed in repairs, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore, fixed in repairs, complete all as specified & directed.
20mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms), fixed in repairs, complete all as specified & directed.
PVC cover suitable for water storage tank of 500 ltrs with locking arrangements, fixed in repairs, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 20mm, fixed in repairs, complete all as specified & directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes by using bleaching powder, hoisting if required, reconnecting and re-fixing in position of capacity exc. 500 but n exc. 1000 ltr, making good for running of water from tank to inside of bldgs and writing of date of cleaning and due on by synthetic enamel paint on water tank, complete all as specified & directed. Note : Cost of bleaching powder shall be deemed included in the quoted rate of this item.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, taking down door shutter and refixing the shutter at same place after laying of tile, complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, taking down door shutter and refixing the shutter at same place after laying of tile, complete all as specified and directed.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc,; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting exc. 10cm girth but not exc 20cm girth in brick/stone walls, complete all as specified & directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Refixing old steel tubing and connections of 15mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed .
Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads, n exc 1.5 sqm, complete all as specified & directed.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
3mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or glazing pins in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing existing water tank of any capacity, refixing at same place after making necessary arrangements, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in roof padding and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Supply only liquid water proofing admixture, complete all as specifed & directed.
Preparation of new treated surfaces of roof and similar items and applying one coat of aluminium paint, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
50mm thick PCC 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including filling of 6mm thick joints with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three part of sand by weight, laid in a stretch not exc 3m and joint at every turning/corners complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Excavation over areas not exc. 1.5m deep in any type of soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
PCC 1:3:6 nominal mix, type C-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to edges of concrete flats, treads, break in floors, window cills, concrete railings openings in concrete walls, floor and roof and n exc. 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but n. exc. 20cm wide for rough finished surfaces of concrete, complete all as specified & directed.
RCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4 but except brick i.e. using serviceable bricks obtained from Srl item No. 01 here-in-before, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified & directed.
Rolled mild steel work in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary length i.e. within 20mm of the length indicated) conforming to Fe-290 grade-E-165, complete all as specified & directed.
Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified & directed.
Barbed razor tape concertina coil SG hot galvanised spring tensile wire as approved by GE, dia of coil when stretched 1000mm having minimum number of circles 12 RM to 13 RM, minimum number of clips 15/RM & minimum weight of coil 0.96 Kg/RM hot dip galvanised, complete all as specified & directed.
Mild steel framed work as in grills, gratings, etc. with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 grade-E-165, complete all as specified & directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified & directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm.
Concrete bed to 300mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Concrete bed to 450mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 300mm, complete all as specified & directed.
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 450mm, complete all as specified & directed.
Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
Machine cut kota stone slab flooring, 18-20 mm thick of size not less than 55cmx55cm as per sample kept in GEs office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing laid over and including 20mm screed layer in cement mortar 1:6, complete all as specified & directed.
Machine cut kota stone slab, 18-20 mm thick as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Machine Pressed precast concrete interlocking paver block any shape and size M-35 Grade, 60mm thick confirming to IS-15658-2006 with grey cement and pigments laid over and including 30mm thick sand cushioning, complete all as specified & directed.
Precast designer coloured paver tiles (factory made rectified) of size 300mmx300mm x 20mm, top layer glazed made in any type of cement and pigment, in required patterns (compressive strength not less than 250 Kg per Sqcm) as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified & directed.
Dura stone external designer floor tiles, any colour, shape and size not less than 300mmx300mm 9-10mm thick M-25 grade, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Granite (of any type/shade), 18-20mm thick as in floor, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting & polishing, making 6mm wide and 18mm deep 'V' groove to be filled with silicon grouting over & including 15mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Granite (of any type/shade), 18-20mm thick as in vertical surfaces such as steps, skirting and similar items, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting & polishing, making 6mm wide and 18mm deep 'V' groove to be filled with silicon grouting over & including 10mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Hard core of gauge n exc 63mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified & directed.
25mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as floor, finished even and fair to receive floor finishes, complete all as specified & directed.
75mm thick PCC 1:3:6 (nominal mix), type C-2 using 40mm graded crushed stone aggregate as in sub base of floor etc, complete all as specified & directed.
75mm thick PCC 1:2:4, nominal mix, type B2, using 40mm graded crushed stone aggregate as in hard standing, path, pavings etc, surface finished even and smooth without using extra cement, laid in alternate bays, complete all as specified & directed.
100mm thick PCC 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in pavement, hard standing, path etc, surface finished even and fair, laid in alternate bays including form work, complete all as specified & directed.
40mm thick PCC 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in floor, surface finished even and smooth without using extra cement, laid in alternate bays, complete all as specified & directed.
Forming Contraction (Dummy) joints 30mm deep x 10mm wide, filled with sealing compound grade ‘A’, complete all as specified & directed.
Taking down steel gate of any description exc 9 Sqm but n exc 16 Sqm each, replacement of old pintel hinges, guide rail and hold fast of any description including ball bearing as per load design and other connected items as per site requirement applying one coat of synthetic enamel paint and refixing in the same or other position after necessary repair and making good for smooth for smooth functioning of the gate, complete all as specified & directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified & directed.
M/S RAVINDER SINGH
JK BUILDERS AND DEVELOPERS
S R CONSTRUCTIONS
GENESIS INDIA
NARESH KUMAR AND COMPANY
KAMAL CONSTRUCTION
Hare krishna engineering const.
M/S Vishwakarma Builders
Modh Hafiz Khan
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .