Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹47.4 L+₹1.6 L (3.45%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹47.6 L+₹1.7 L (3.81%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹48.4 L+₹2.5 L (5.55%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹48.6 L+₹2.8 L (6.01%)Rejected-Finance 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | L5 | Rejected-Finance Rejected being L5 |
| Sl No | Description | Qty | Unit | M/s Pramillabh Construction L8 | M/s Sashi Enterprise L6 | M/s PRABIR ENTERPRISE L1 | M/S A K BROTHERS L3 | M/S S. P. ENTERPRISE L4 | M/S A K ENTERPRISE L5 | MAA COMMUNICATION L2 | M/s Lalowari Electricals L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down Old burnt /Unserviceable upto 10X2 core / 16X4 Sqmm underground XLPE Cable aluminum conductor LT 1100 V grade after disconnecting of electric connection all as specified and directed at site. | 450 | RM | 19 ₹8,550 | 17 ₹7,650 | 14 ₹6,300 | 16 ₹7,200 | 22 ₹9,900 | 11 ₹4,950 Lowest | 20 ₹9,000 | 18 ₹8,100 |
| 2.00 | All as per ser item No 01 (here in before) but Size of cable 25/35 Sqmm X 3.5 core | 300 | RM | 28 ₹8,400 | 23 ₹6,900 | 21 ₹6,300 | 24 ₹7,200 | 31 ₹9,300 | 19 ₹5,700 Lowest | 25 ₹7,500 | 27 ₹8,100 |
| 3.00 | All as per ser item No 01 (here in before) but Size of cable 50/70 Sqmm X 3.5 core | 230 | RM | 33 ₹7,590 | 30 ₹6,900 | 25 ₹5,750 | 28 ₹6,440 | 36 ₹8,280 | 22 ₹5,060 Lowest | 29 ₹6,670 | 31 ₹7,130 |
| 4.00 | All as per ser item No 01 (here in before) but Size of cable 95/120 Sqmm X 3/3.5 core | 160 | RM | 43 ₹6,880 | 36 ₹5,760 | 32 ₹5,120 | 35 ₹5,600 | 46 ₹7,360 | 27 ₹4,320 Lowest | 40 ₹6,400 | 38 ₹6,080 |
| 5.00 | Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs of size 10 sqmm x 2 core complete all as specified and as directed. | 200 | RM | 274 ₹54,800 | 220 ₹44,000 Lowest | 240 ₹48,000 | 252 ₹50,400 | 255 ₹51,000 | 274 ₹54,800 | 220 ₹44,000 Lowest | 277 ₹55,400 |
| 6.00 | All as per item No 05 (here in before) but Size of cable 16 Sqmm X 4 core | 250 | RM | 408 ₹1,02,000 | 436 ₹1,09,000 | 360 ₹90,000 Lowest | 378 ₹94,500 | 401 ₹1,00,250 | 410 ₹1,02,500 | 405 ₹1,01,250 | 419 ₹1,04,750 |
| 7.00 | All as per item No 05 (here in before) but Size of cable 25 Sqmm X 4 core | 150 | RM | 521 ₹78,150 | 557 ₹83,550 | 460 ₹69,000 Lowest | 483 ₹72,450 | 513 ₹76,950 | 523 ₹78,450 | 518 ₹77,700 | 535 ₹80,250 |
| 8.00 | All as per item No 05 (here in before) but Size of cable 35 Sqmm X 3.5 core | 150 | RM | 589 ₹88,350 | 562 ₹84,300 | 520 ₹78,000 Lowest | 546 ₹81,900 | 579 ₹86,850 | 591 ₹88,650 | 586 ₹87,900 | 606 ₹90,900 |
| 9.00 | All as per item No 05 (here in before) but Size of cable 50 Sqmm X 3.5 core | 150 | RM | 793 ₹1,18,950 | 755 ₹1,13,250 | 700 ₹1,05,000 | 735 ₹1,10,250 | 655 ₹98,250 Lowest | 797 ₹1,19,550 | 787 ₹1,18,050 | 815 ₹1,22,250 |
| 10.00 | All as per item No 05 (here in before) but Size of cable 70 Sqmm X 3.5 core | 80 | RM | 1,184 ₹94,720 | 1,202 ₹96,160 | 1,120 ₹89,600 | 1,176 ₹94,080 | 1,052 ₹84,160 Lowest | 1,278 ₹1,02,240 | 1,261 ₹1,00,880 | 1,303 ₹1,04,240 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Aug 2025, 6:00 pmClosed
GE (AF) CHABUA
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/ MAINT OF EXTERNAL ELECTRIFICATION OF LT DISTRIBUTION SYSTEM, UG CABLES, OH CONDUCTORS, LT PANEL, STREET LIGHT, PERIMETER LIGHT, RUNWAY LIGHT AND COMPREHENSIVE MAINT OF DG SETS, ALONGWITH CABLE, GGGOAB SWITCH, DISTRIBUTION TRANFORMER
2025_MES_721867_1
716
Open Tender
Civil Works
Item Rate
270 days
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUG
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Chauba
₹90,000
Yes
29 Aug 2025
23 Jul 2025
15 Aug 2025
23 Jul 2025
13 Aug 2025
6 Aug 2025
23 Jul 2025 - 30 Jul 2025
Amount
Taking down Old burnt /Unserviceable upto 10X2 core / 16X4 Sqmm underground XLPE Cable aluminum conductor LT 1100 V grade after disconnecting of electric connection all as specified and directed at site.
All as per ser item No 01 (here in before) but Size of cable 25/35 Sqmm X 3.5 core
All as per ser item No 01 (here in before) but Size of cable 50/70 Sqmm X 3.5 core
All as per ser item No 01 (here in before) but Size of cable 95/120 Sqmm X 3/3.5 core
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminum conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminum lugs of size 10 sqmm x 2 core complete all as specified and as directed.
All as per item No 05 (here in before) but Size of cable 16 Sqmm X 4 core
All as per item No 05 (here in before) but Size of cable 25 Sqmm X 4 core
All as per item No 05 (here in before) but Size of cable 35 Sqmm X 3.5 core
All as per item No 05 (here in before) but Size of cable 50 Sqmm X 3.5 core
All as per item No 05 (here in before) but Size of cable 70 Sqmm X 3.5 core
All as per item No 05 above but Size of cable 95 Sqmm X 3.5 core
All as per item No 05 above but Size of cable 120 Sqmm X 3.5 core
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified.
Cutting bituminous road/path for passing of elect cable through GI pipes and making good to the cut surfaces by concreating with PCC 1:3:6 to match with the adjescent surfaces complete all as dircted at site.
Supply and fix in repair steel tubes, galvanised, light grade, ISI marked 40 mm bore for protection of cable under floor, road and on wall complete.
Supply and fix in repair steel tubes, galvanised, light grade, ISI marked 50 mm bore for protection of cable under floor, road and on wall complete.
Supply and fix in repair steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 2/4 core XLPE, armoured, Al conductor cable of size 10 to 16 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 70 to 120 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Outdoor type for joininng of damaged cable complete all as directed.
M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing 40 to 80mm bore complete all as specified and directed.
S&F in replacement of MCCB, 4P, 250 Amps, 36kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in replacement of MCCB, 4P, 200 Amps, 36 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in replacement of MCCB, 4P, 160 Amps, 36 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in replacement of MCCB, 4P, 100 Amps, 16 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in replacement of MCCB, 4P, 63 Amps, 16 kA breaking capacity with overload and thermal tripping feature, 415Volts AC, 50Hz complete all as specified and directed. Note:- Minor addition/ alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate.
S&F in repair load changeover switch four pole of 200 Amps, 415 volts, 50 Hz in SS enclosure complete all as specified & directed. Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates.
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on LT/HT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire, complete all as directed by Engr-in-Charge.
M & L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer, complete all as directed.
Supply and stringing in repair ACSR conductor of any size for LT/HT over head line as directed including fixing to insulators with proper size of binding wire complete.
Supply and fix in repair GI wire of 4 mm dia including fixing of insulator on suitable length complete all as specified and directed at site.
Supply and fix in repair pin type, porcelain, vitreous, white brown or green insulator including one galvnised mild steel spindle, two nos galvanised iron washer and one galvnised iron nut, 100 mm height, 65 mm dia for 1100 v grade complete all as specified & directed.
Supply and fix in repair shackle, porcelain, vitreous, white brown or green insulator including galvnised mild steel straps, washers, insulator, bolts, washers and nuts for size 100 mm height and 115mm dia for 1100 Volts with 31x5 mm galvanised steel straps and 14 mm dia of bolts complete all as specified.
M&L for preparation of old painted steel surface of LT poles and applying two coats of aluminium paint upto 6 mtr height on outer surfaces of pole from 1.5 m above the couping/ground level up to the top of steel poles including painting of MS cross arms, clamps, nuts and bolts etc and painting alternative black and white strips of 30 CM height with two coats of synthetic enamel paint up to 1.5 mtr height from the ground/couping level including writing pole No. with letters of size 25 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and as directed
S&F in repair voltmeter digital type 0-500 volts AC, flush mounting type, 3 phase complete all as specified.
S&F in repair ammeter digital type, flush mounting type, 3 phase complete with suitable CTs of range as required on site complete all as specified.
S&F in repair CTs of range 400/5Amps as required on site complete all as specified.
S&F in repair LED indicator as per colour scheme (Red/Yellow/Blue/Green) suitable for LT panel complete all as specified.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
Taking out the existing worm out old and unserviseble ACSR conductor of any size complete all as specified
Taking dowan the existing worm out old and unserviseble Lt steel pole 9 mtr long with PCC plinth complete all as specified
Supply and fixing steel tubular swaged poles with cast iron base plate, final taper plug bolts, nuts, screws as specified type 410 SP-31 (9.0 Mtr long) incl embossing the manufacturers name and IS No of pole and erecting in position all as specified and directed incl painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat red oxide primer and painting of 30 cm wide red and white strips upto 1.5 mtr from bottom of the errected pole including marking of pole number including taking down old/unsv/damaged PCC/steel pole complete with all accessories incl demolition of concrete complete all as specified and directed. Note: Necessary excavation, earth work and PCC shall be measured and paid for separately
Supply and fixing in repairs mild steel galvanised stay assembly set complete comprising of 14mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90x140mm, clearance of hole 25.5mm, all as shown in electrical plate No.1 of MES Schedule part-I 1991 complete all as directed.
M&L for repair/ maintenance of LT panel door by replacement of hinges and locking arrangement including necessary welding/ nuts, bolts, washers as per existing size/ type complete all as specified and directed. Note: (i) One side door will be measured & paid as one job. (ii) New LT panel door (only) of suitable size and thickness shall be measured and paid separately under relevant item of this schedule.)
Supply and fixing in replacement of Aluminium busbar of suitable capacity in any shape and size as required on site complete all as specified
Supply and fix in repair pin type, porcelain, vitreous, white brown or green insulator including one galvnised mild steel spindle, two nos galvanised iron washer and one galvnised iron nut, 150 mm height, 150 mm dia for 11000 v grade complete all as specified & directed.
M&L for replacement of disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white,brown or green single disc assy for tension with tension clamps for conductors,working pressure 11000 volts complete all as specified and directed.
Cutting and trtmming of tree branches to clear the over head lines in the arc of LT over head lines (including repairing and jointing of ACSR Conductor if damaged during cutting of tree) and removing of the trimmed branches of trees,removing and depositing the same away from the site ,complete all as specified and directed by engr-in-charge/jJE E/M Note- (i) All tools and ladder required for the job should be arranged by the contractor at his own cost. (ii) Pole to pole distance shall be measured as one span.
Disconnecting the distribution transformer outdoor/ indoor type from HT and LT side, opening carefully at site, draining out transformer oil (keeping safe in barrel for reuse) upto HT/ LT box for rectifying the leakage by replacing the unserviceable spare parts of capacity 125 to 315 KVA, 11/ 0.433 KV transformer, refilling the transformer oil and re-assembling after repair including testing for any oil leakages and connecting the HT/ LT side and testing on available electric load complete all specified and directed by Engr-in-Charge. Note:- (a) Defective parts shall be measured and paid separately as "Supply only". (b) Charge of welding work (if require) is deemed to be included in the quoted rate. (c) Connection sleeves, insulated plates, nut, bolts & washers etc (if required) is deemed to be included in the quoted rate.
Supply only Tap changer assy suitable for 125 KVA to 315 KVA Transformer
Supply only HT side bushing with brass stud suitable for 125 KVA to 315 KVA Transformer
Supply only LT side bushing with brass stud suitable for 125 KVA to 315 KVA Transformer
Supply only Transformer top cover gasket/cock sheet suitable for 125 KVA to 315 KVA transformer
Supply and fix in replacement of air breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with new silica gel (blue in colour) suitable for 125 to 315 KVA, 11/ 0.433 KV transformer, fixing on existing pipe of size 15/20/25 mm dia with suitable reducer/ connector complete as per site requirement all specified and directed by Engr-in-Charge. Note:- (a) Cost of modification (if required to fix on existing MS pipe) shall be deemed to included in the item quoted rate.
Supply and fix in replacement of danger notice plate of 1.6 mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull & bones in signal red colour & fixed with & including MS clamps, bolts, nuts and of size 25 x 20cm for HT 11KV complete all specified and directed.
S&F in replacement of anti climbing devices comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as directed by Engr-in-Charge. Note:- (a) Clamps required shall be measured seperately
S&F in replacement of anti-climbing device spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole or as ordered complete all as specified and directed.
Supply and filling silica gel
Supply and fix in repair oil level indicator suitable for 125 to 315 KVA, 11/ 0.433 KV transformer alongwith connected accessories complete all specified and directed by Engr-in-Charge.
Material and labour for painting of any type pole of HT over head line of upto 11 m long (except embedded portion) complete including all MS work mounted on pole with two coat of aluminium paint after necessary preparation, cleaning including scrapping up of old corroded paint dirt/ dust/ rust carefully and providing 03 Nos bands/ straps with synthetic enamel paint (any tint 30 cm wide each) from top of plinth block and writing of pole number with white synthetic enamel paint on black back ground complete all as specified and directed by Engr-in-charge.
Material and labour, painting of two pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour, painting of four pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate for fdn of pole/ stay/ angle/ pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for fdn of pole/ stay/ angle/ pipe complete all as specified and directed.
M&L for PCC 1:2:4 type C2 using 20mm graded for padestal coping including necessary form work finished fair using extra complete all as specified and directed.
M & L for rewinding HT/LV coils of transformer by using proper size super enameld copper wire suitable for working voltage 11 KV/0.433 KV including three layer insulated material as per existing size of core including testing and commissioning complete all as specified and directed at site. NOTE :- i). Oil filtration,supply of new oil will be measured separately. ii). All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted. iii). The rate for taking out,refixing after repair,both side transportation, lifting /unloading of voltage stabilizer/isolation transformer by crane /manual should be deemed to include in the rate quoted.
M&L for dehydration & filteration of transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed by Engr-in-charge. Note: (a) The filtration of the transformer oil shall be carried out at different sub stations of Air Force Station Mohanbari. (b) The report before filtration & after filtration to be submitted by contractor. (c) Transformer oil for topping up will be measured and paid separately.
Supply & toping up of new transformer oil (in sealed barrel) confirming to IS 335 Std having dielectric strength 40KV at 2.5mm gap after initial dehydration complete all as specified. Make: Savita/ Castrol/ Power oil/ Truoil.
M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of 125 KVA to 315 KVA transformer (11/0.433KV) complete with all connected fittings & fixtures i.e. buchholz relay, conservator tank, cooling fins and other standard fittings & attachments as per existing colour scheme and pattern with atleast two coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction of Engr-in-Charge complete all as specified. Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates.
S&F in repair gang operated air break switch triple pole, mechanically manual operated, mounted on 9 Nos insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 Amps, 11000volts complete all as specified and directed.
M&L for drop out fuse single pole suitable for 11000 volts grade complete all as specified and directed.
S&F in replacement of lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps, 11000 volts complete all as specified and directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
M&L for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI wire 4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected up to main DB/LT Panel /Test point and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) complete all as specified and directed.
Excavation in trenches, in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, or for shafts, wells, manholes, pier holes,cable laying, sewage/water lines etc complete all as specified and directed.
Excavation in trenches in soft/loose soil, n.exc 1.5 m wide and exc 1.50m but n.exc 3.0 m in depth for foundation or shafts, wells cesspit, manholes, pier holes,cable laying, sewage/water lines etc complete all as specified and directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
M&L sub class B brick,well burn laid bridth-wise along the length the cable laid in trench over sand cushion,laid for ug cable protection complete all as specified and directed at site.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300 mmx 180 mm x 40 mm laid in trenches as cable covers complete all as directed.
Taking down carefully unserviceable Street liight/Security light/Hangar light fitting from pole/Structure and repair/replacement of worn out parts and carbon cleaning of fittings,cover,copper wire/aluminium wire,clamps ,nuts and bolts, mounting bracket and re assembling the same after repair,testing and refixing in pole/other location and repairing of cable /junction box / timer / contract L1 &L2 /MCB SPN/SARVICE WIRE including provision of necessery T & P like ladder/Boom Vehicle, tools ets as required for taking down and refixing of street light complete all as specefied and directed. . "Note (i) Replacement of defective spare parts of fitting (to make functional ) shall be measured and paid separately as supply only. However, cost of replacement screws, nuts, bolts, and cleaning of fittings shall be deemed to be included in quoted rate. (ii) Minor consumable material required to complete the job as (like tape, thimbles,, , electrical gloves, M seal etc) are included in quoted rates. (iii) The contractor's supervisor and his electricians at Sub stn shall be available round the clock i.e 24 Hours, mobile number of supervisor to be distributed and complaint book to be maintained. (iv) Contractor shall be provide/depute sufficient number of electricians and helpers (as directed by Enginerr-in-Charge) to attend the complaints and rectify/replace the parts and the complaint shall be resolve within 24 hours of receipts of complaints. If contractor fails to attend & resolve the complaint within 24 hours an recovery of Rs.100 per day /complaint shall be recovered from contractor dues. (v) Contractor manpower shall attend daily to receive complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaint and handover a complaint slip to JE E/M user signature as a record of attending the complaints for payment purpose"
S&F in replacement LED driver of 45 Watt as per existing make of LED street light fittings complete all specified and directed.
S&F in replacement LED driver of 60 Watt as per existing make of LED street light fittings complete all specified and directed.
Supply and fix in repair LED driver suitable for 100 watt as per existing LED flood Light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 150 watt as per existing LED flood Light fitting complete all as specified and directed.
Supply and fix in repair LED driver suitable for 200 watt as per existing LED flood Light fitting complete all as specified and directed.
S&F in repair LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 45 W capacity after taking down the old unserviceable one complete all as specified and directed .
S&F in repair LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 60 W capacity after taking down the old unserviceable one complete all as specified and directed .
S&F in repair LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 90 W capacity after taking down the old unserviceable one complete all as specified and directed .
S&F in repair LED street light energy saving & environmental friendly long life made up of pressure die-cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of 120 W capacity after taking down the old unserviceable one complete all as specified and directed .
Taking down post top lantern /Gate light/Garden light any type for repair and refixing the same on its existing position after necessary repair work (Spares and supply item required will measured and paid under separate item 16 to 20 here in after).labour cost for replacing spare parts to be inclusive in the quoted rate .
Supply only outdoor integral decorative post top lantern luminaire 40 w LED ,ip 65 protection and three core twisted copper conductor flexible wire from busbar to connector all as specified and as directed.Make : CG or equivalent of Havells /Bajaj.
Supply and fix in repair post top lantern fittings and supply & fixing post top luminaire LED type of 25 W of post top lantern with aluminium die-cast housing cum heat sink in IP-65 protection including all fixinging arrangement complete all as specified and as directed,
Supply and fix in repair post top lantern fittings and supply & fixing post top luminaire LED type of 20 W of post top lantern with aluminium die-cast housing cum heat sink in IP-65 protection including all fixinging arrangement complete all as specified and as directed,
Supply and fix in repair, 8 watts LED bolards light IP-65 protection, resistant to corrosion better optics for uniform distribution including all fixing arrangements complete all as specified and as directed,
Supply and fix in repair, LED runway light fittings including all fixing arrangements complete all as specified and as directed,
S&F in repair flood light fitting mounted on high mast light of 100 watt energy saving,environmental friendly,long life,made up of pressure die-cast aluminium housing with toughened glass and high power LEDs IP66 protection,suitable for highlighting architectural facade and general purpose lighting after taking down the old unsv one complete all as specified and directed. Make : Havells /Crompton or equivalent in approved make
S&F in repair flood light fitting mounted on high mast light of 150 watt energy saving,environmental friendly,long life,made up of pressure die-cast aluminium housing with toughened glass and high power LEDs IP66 protection,suitable for highlighting architectural facade and general purpose lighting after taking down the old unsv one complete all as specified and directed. Make : Havells /Crompton or equivalent in approved make
S&F in repair flood light fitting mounted on high mast light of 200 watt energy saving,environmental friendly,long life,made up of pressure die-cast aluminium housing with toughened glass and high power LEDs IP66 protection,suitable for highlighting architectural facade and general purpose lighting after taking down the old unsv one complete all as specified and directed. Make : Havells /Crompton or equivalent in approved make
Supply and fix in repair cable junction box IP 66 weather proof for outdoor installation (with metric knockouts for cable entry) size 205 x 255 x 112 mm suitable for10/ 16/25 sqmm cable fixed to pole/ wall with suitable FI clamp 20X3 mm nuts , bolts and washers including provision of 01 No MCB, single pole, 240 volts, 10 KA 6 Amps, and suitable aluminium bus bar/ connector complete all as specified and directed.
Supply and fixing in replacement of PVC insulated and PVC round sheathed, copper conductor industrial cable 1.5 sqmm, 1100 volts grade, three core of copper conductor for connection of street light/ flood light/ post top lantern/ garden lights etc. fittings on pole/ wall/ pillar/ from over head conductor / junction box / DB including termination clip complete in all respect complete all as specified & directed.
Taking down old unserviceable service wires of any description complete all as specified and directed.
Supplying and fixing 1100 volts grade,heavy duty cable with PVC insulated, aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x 4 sqmm with IS 694: 2010,complete all as specified and as directed.Make: Richa/Plaza/Havells
Supplying and fixing 1100 volts grade,heavy duty cable with PVC insulated, aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed, flat or circular of size 2 core x 6 sqmm with IS 694: 2010,complete all as specified and as directed.Make: Richa/Plaza/Havells
Supplying and fixing 1100 volts grade,heavy duty cable with PVC insulated,multistranded aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed,flat or circular of size 2 core x10 sqmm,complete all as specified and as directed.
Taking down old unsv UG cable of size 16 sqmm x 2 cor complete all as specified and as directed at site.
Supply and laying in trenches or drawn through pipe or fixed on wall/poles, LT UG cable heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor of size 16 sqmm x 2 core complet all as specified and as directed at site.
Supply and fix street light GI bracket,bend to 120 degree angle,made out of 32/40 mm bore,gI pipe,light grade (approx 1.5 mtr in length) including necessary two nos suitable size of clamps with nuts,bolts and washers etc and two coat of synthetic enameled paint over a coat of red oxide primer including taking down the old rusted one complete all as specified and directed.
S&F in replacement of MCB SP 240 volt 6 to 32 Amps 'C' series 10 KA complete all as specified and directed at site.
Carrying out routine, preventive maint & servicing of 380 KVA DG set Make: Cumins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center/ auth service center of OEM periodicaly or on requirement basis and replacement of unserviceable spare parts/ accessories including calibration of control devices/ refitting of serviceable parts after cleaning/ servicing including minor consumables accessories like cotton, waste cloth, kerosene oil etc including draining of oil dust from foundation/ base plate complete all as specified and directed for the following under mentioned DG set:- (a) Check clearance of suction and exhaust valves including adjust, if required. (b) Changing of oil filter, fuel filters, water filter,screen filters assy, air filter etc. (c) Topping up of coolant & changing of hydraulic governer oil. (d) Tightening of all nut bolts including greasing of all points. (e) Checking of any leakage in fuel tank and oil lines. (f) Adjusting valve tappet clearance/timing, injector pressure test, cleaning and repairing,tightining fasteners and making lubrication leak proof. (g) Repair/ rewiring of broken/ damaged control panel connection including measuring instruments, indicators, engine protection devices etc. Note . (i): Labour charges for dismantling/ taking down and replacement/ refixing parts as and when required is deemed to be included in unit item quoted rate. (ii): Spare parts like oil filter, fuel filter, water filter, screen filter by pass filter, air filter etc will be measured and paid separately.
All as per ser item No 113 here-in-before but Cap of DG Set 200 KVA
Supply only disel filter suitable for 380 kVA DG set complete all as specified and directed at site.
All as per ser item No 115 here-in-before but Cap of DG Set 200 KVA
Supply only oil filter suitable for 380 kVA DG set complete all as specified and directed at site.
All as per ser item No 117 here-in-before but Cap of DG Set 200 KVA
Supply only air filter suitable for 380 kVA DG set complete all as specified and directed at site.
All as per ser item No 119 here-in-before but Cap of DG Set 200 KVA
Supply only Water Separater suitable for 380 kVA DG set complete all as specified and directed at site.
All as per ser item No 120 here-in-before but Cap of DG Set 200 KVA
S&F in replacement battery terminal cable, copper conductor with brass adaptor at both side of end point, multistrand, unsheathed, single core, 25 Sqmm, 1100 volts grade in length of 1.5 mtr long suitable for 12 Volts & upto 180 AH battery. Complete all as specified and directed.
De-scaling of radiator assembly by carefully from the engine,transporting to civil workshop and removing the sediments,scales and rust etc by means of chemical cleaning,high pressure water washing and air cleaning, arresting the leakages by gas welding/soldering with suitable material, and re-assembling the same with new gaskets including replacement of radiator cap(whereever required) and transporting to the site, fixing to the engine for DG set of capcity 380 KVA and testing for satisfactory performance complete all as specified and directecd at site.
All as per ser item No 124 here-in-before but Cap of DG Set 200 KVA
Calibration of FIP including replacement of barrel plunger,cups & 'O' rings etc suitable for 320 KVA DG Set complete all as specified and directed at site.
All as per ser item No 126 here-in-before but Cap of DG Set 200 KVA
Supply and fix in repair AVR as per existing model suitable for 380 KVA DG Set complete complete all as specified and directed.
Supply and fix in replacement AVR as per existing model suitable for 200 KVA DG Set complete complete all as specified and directed.
Supply and fixing SMPS electronic battery charger 24 v, 10 amps complete with all connecting accessories and connecting wire all as specified and as directed.Note : Chrger shall be fixed in existing panel
Material and labour for cleaning of fuel tank of 380 kVA DG Set by taking out diesel in separate container, tank out of DG set, cleaning & removing all dirt/ sluge/ mud, dust, washing with fresh water thoroughly, drying and fixing back to its original location including making of all connection and re-filling of diesel in tank complete all as specified and directed.
All as per ser item No 131 here-in-before but Cap of DG Set 200 KVA
M&L for complete painting of 200 KVA DG set of make:- Kirloskar with alternator ,base plate by using heat resistant paint with spray gun over existing surface as per existing colour code after taking out old paint ,dirt and dust from the DG set body, alternator and engine complete all as specified and directed by Engr-in-Charge.
M&L for complete painting of 380 KVA DG set of make:- Kirloskar with alternator ,base plate by using heat resistant paint with spray gun over existing surface as per existing colour code after taking out old paint ,dirt and dust from the DG set body, alternator and engine complete all as specified and directed by Engr-in-Charge.
Supply and filling lubricant oil 15 w 40 for topping up/replacement in engine chamber complete all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
Supply & topping up heavy duty concentrate/ anti freeze radiator premixed coolant complete all as specified. (Make-HP/ Servo/ Castrol)
Supply & topping up distilled water for batteries complete all as specified.
Supply and fixing in replacement of maintenance free battery with initially charged of capacity 180 AH, 12 volt complete all as specified and directec at site.
Dismantling the defective water pump assembly and supply and fix new water pump assembly suitable for existing 320 KVA DG set complete all as specified and directed at site.
Dismantling the defective water pump assembly and supply and fix new water pump assembly suitable for existing 200 KVA DG set complete all as specified and directed at site.
Supply and fixing oil temp sensor suitable for DG set suitable for 380 KVA complete all as specified and directed at site.
Supply and fixing in repair solenoid coil suitable for DG set of capacity 200 KVA complete all as specified and directed at site.
Supply and fix in replacement self starter assembly 24 volt suitable for 380 KVA DG Set complete all as specified and as directed.
S&F in repair fuel pipe suitable for 200/380 KVA DG set complete including clip all as specified and directed.
S&F in repair V belt suitable for 380 KVA DG set all as specified and directed.
S&F in repair V belt suitable for 200 KVA DG set all as specified and directed.
Supply and fix in repair turbocharger suitable for 320 KVA DG Set complete all as specified and directed at site.
Supply and fix in repair bellow suitable for 200 KVA DG Set complete all as specified and directed at site.
M&L for taking out self starter 24 volt from the DG set capacity up to 320 KVA , transportation to civil workshop and opening/ disconnecting all internal connection, cleaning the same taking out burnt armature, segrigation of serviceable parts for re-use, rewinding of armature with copper wire of existing size, assembling all parts, testing & fixing back to the DG set complete all as specified and directed by Engr-in-Charge.
M&L for finding out defects of fully automatic mains failure panel (AMF) of DG set of capacity upto 320 KVA and taking out burnt inter connection wiring including u/s and serviceable components for reuse and rewiring of panel using existing size of copper cable, ferrule, lugs, insulating material, nut, bolt, washer of various sizes, refixing serviceable items including replacement of contactor with auxiliary coil and testing complete for proper functioning complete all as specified.
All as per ser item No 150 here-in-before but Cap of DG Set 200 KVA
Servicing of Main LT Panel-1 Technical Area & main LT Panel -2 D Block non Comprehensive Contactor Servicing with Bus bar Tightness & Insulation Sleeve Checking & Interlocking Logical Testing Charge and the the under mention scope of wrok for Air Circuit Breaker Service is as under aloso carried out Note : Spare parts shall be measure air breaker service id paid and saperately. (i) Visula inspection of components of contactor & ACB to asses condition. (ii) Cleaning of contactor & ACB with CRC 2-26 cleaner. (iii) Removal of old grease and re grease (iv) Check the condition of arching contact and gap (v) Checking protection release parameters and testing of release (vi) Checking presence of all Cir Clips (vii) Checking condition of Contactor & ACB wiring (viii) Checking proper closing of all poles by taking impression etc (ix) Checking condition of Arc Chutes (x) Checking contactor Opening through Y/O coil (xi) Checking contactor closing through Y/C coil (xii) Checking Contactor Opening through U/V coil (xiii) Setting of release as per the load or as per customer requirement (xiv) Checking main operating mechanism and replacing it in case of any failure
Installing of S7 1200 PLC programming & Automation Charge on Technical area & D Block
Supply only Under/Over Voltage relay with phase loss Protection Relay Make : L&T
Supply only Auxiliary Relay 4c/o with Base 230 v AC Make : Omron
Supply only Illumination Push Button Green 24 v DC Make Esbee GIC L&T with 1 Nc
Supply only Illumination Push Button Green 230 v AC Make Esbee GIC L&T with 1 No
Supply only Battery Charger transformer inbuilt 230/24v 10 A Make Mahamai
M & L for rewinding of DG set alternator/Stator/Rotor coil /Rectifier Coil Unit of any capacity with super enemelled copper wire of existing gauge incluiding all connected insulating material, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out of rotor with proper care and reinsulation of burnt out rotor/stator after rewinding work including re-assembling and testing on site including taking out alternator from AF Stn Chabua to auth workshop and after repair from workshop to site complete all as specified and directed at site.
M&L preparation of steel and iron surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
M&L for spreading of graded crashed aggregate 40mm nominal size to a true surface and leveled in layers not exc. 20 cm thick for switch yard complete all as specified and directed by Engr-in-Charge.
MAA COMMUNICATION (BID ID -3390776)
M/S A K BROTHERS (BID ID -3388824)
M/S S. P. ENTERPRISE (BID ID -3390272)
M/S A K ENTERPRISE (BID ID -3388842)
M/s Sashi Enterprise (BID ID -3387741)
M/s Lalowari Electricals (BID ID -3387766)
M/s Pramillabh Construction (BID ID -3387640)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .