Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC VILLAGE RANGA PO BHANGALA TEHSIL MUKERIAN | ₹19.8 L | L1 | Accepted-AOC accepeted |
| 2 | L2₹20.6 LRejected-AOC VPO DEPUR TEHSIL MUKERIAN DISTT HOSHIARPUR PUNJAB | DEPUR | HOSHIARPUR | PUNJAB | ₹20.6 L | L2 | Rejected-AOC rejected |
| 3 | L3₹20.8 LRejected-AOC HOUSE NO 11 STREET NO 2 GAUTAM NAGAR | S A S NAGAR | S A S NAGAR | PUNJAB | ₹20.8 L | L3 | Rejected-AOC rejected |
Tender Value
₹22.2 L
EMD Value
₹44,500
Closing Date
2 Feb 2026, 5:00 pmClosed
Executive Engineer
Executive Engineer Construction Division PWD B and R Br Mukerian
Construction of Canteen in MRPD Collecge at Talwara Distt Hoshiarpur
2026_CEPW_158548_1
Constrcution of Canteen in MRPB College at Talwara
Open Tender
Civil Works - Buildings
90 days
Mukerian
Please refer Tender documents.
13 documents required · 13 mandatory
₹5,000
₹44,500
Yes
13 Mar 2026
23 Jan 2026
3 Feb 2026
23 Jan 2026
2 Feb 2026
23 Jan 2026
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge. [CSR 6.6]
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 6.8a].
Centring and Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 9.1].
Centering and shuttering for columns (Square or rectangular or poly gonal in plain) [CSR 9.4]
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. [CSR 9.8]
Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by manual means [CSR 10.11-b-i]
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth [CSR 11.7]
First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level. [CSR 11.8]
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth [CSR 10.16]
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete CSR 18.18
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) Complete in all respect as per specification, drawing and to the entire satisfaction of Engineer-in-charge. [CSR 14.84]
Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge. [CSR 14.86]
Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge - Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent [CSR 14.89b].
12.5 mm thick cement plaster 1:4 Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 15.9].
20mm thick cement plaster 1:4 in two coat work Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 15.20].
Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete [CSR 16.6]
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade [CSR 16.10]
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm [CSR 16.60]
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of wire brushing Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 13.13-i].
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 13.55].
Embedding 100mm C.I. rain water pipe non pressure I.S.I. Mark pipe in cement mortar during masonary work Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 13.44].
Providing and fixing cast iron shoe for rain water pipe on wooden plugs fixed on wall face including filling the joints with spun yarn and cement mortar 1:2 Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 13.43].
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 13.45].
Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 Complete in all respect as per specification , drawing and to the entire satisfaction of Engineer-in-charge [CSR 13.51].
Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete - Doors and windows frame of size 161mm x 60mm with 40 mm wide double rebate weighing 4.05 kg per meter [CSR 18.24d]
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately) - For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required CSR 17.45 B
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. Qty. Of item wire gauge window [CSR 18.27]
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) [CSR 17.23-i]
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position [CSR 18.4]
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) [CSR 17.43c]
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm - 5.0mm thick Plate glass (INDIAN) [CSR 17.26-b-iii]
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter /emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete [CSR 14.126].
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 630 mm x 450 mm x 830 mm [CSR 30.32-iii]
Providing & Fixing in position 5mm thick bevelled edgemirror of superior glass (of approved make) completewith 4mm thick hard board backing fixed in with rawlplugs 50mm, C.P. brass screws and washers and S/SStuds on top complete in all respect (as required by theEngineer-in- Charge) Size 550mmx400mm [CSR 30.61b]
providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 450 mm with C.P.Brass nut [CSR 30.72b]
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect.C.P. brass Bib cock foam flow without flange [CSR 30.65-a-ii]
Providing & Fixing in postion stop cock / Angle valve ofapproved make (to the approval of Engineer-in-charge) complete in all respect. C.P.brass 15mm stop cock Male and female end [CSR 30.66a]
Providing and fixing in position C.P. brass soap dish ofapproved make (to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P brass screwscomplete in all respect [CSR 30.60].
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge) fixed in with rawl plugs embedded in walls with brassscrews complete in all respect.C.P. brass towel Railssize 15mm dia 610mm long [CSR 30.58a]
Providing, Laying , fixing & jointing of P.V.C. Pipes asper ISI-4985 (ISI marked with the prior approval ofEngineer-in-Charge) along the Trenches and laying thesame in Trenches to correct alignment and gradients,cutting, jointing and testing complete as perspecifications. 110mm o/d PVC pipe of 4 Kgf. / sqcm [CSR 28.13-xxii]
Providing & Fixing in position C.P. Brass Hexa Nipple15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect [CSR 30.64c]
Providing and laying, Jointing, Fixing, Testing ISI Marked G.I. Pipe (As per IS 1239) B-Class, premiummake such as (Jindal/ Hisar) including cost of specialssuch as Tee’s, Bends, Sockets, Elbow etc. cutting,threading & testing in trenches in the ground complete. 32mm i/d G.I Pipe [CSR 28.36d]
Providing & placing in position on terrace (at all floorlevels) HDPE water storage tanks of approved make(to the approval of Engineer - in-charge) with cover withsuitable locking arrangement and making necessaryholes for inlet, outlet and over flo pipes but withoutfittings and base support for tank.Triple Layer Tanks [CSR 30.97a-i]
Providing and fixing in position Centrifugally cast ironsoil waste vent or antisyphonage pipes single socket toI.S.I. specification of E.D.C manufacture or of any otherreputed firm including cutting, jointing, wastage, butexcluding cost of lead jointing. 100mm i/d single socket Centrifugally cast iron pipelines laid complete [CSR 30.74-ii-b]
Providing and fixing in position automatic brass Ball Cock in tanks.A (i) Plastic Ball Cock with rod and Plastic Ball 15mm i/d [CSR 30.96 a-i]
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. (c) G.I. tank nipple 25mm i/d [CSR 30.98 c]
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect - Double bowl Sink without drain board Overall size 1330x515 bowl size 560x410x200mm [CSR 30.47e]
Internal Electrical Installations: RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring fan point (Without fan box) [CSR 34.02]
Wiring light point
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1sq.mm (Un-sheathed) [CSR 34.09]
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- Overall size 10sq.mm (2Core) un-Armoured (On-Surface) [CSR 34.10]
XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 10sq.mm (4Core) Un-armoured (Loose). [CSR 34.10d]
Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. [CSR 34.11]
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) [CSr 34.12x]
Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- PVC Flexible Pipe 25mm dia. [CSR 34.12b]
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) [CSR 34.13-(xiii) a]
Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed)
Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- Ceiling Rose (Flush Piano type) [CSR 34.15-xxvi]
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C) [CSR 34.16A]
MCB Double Pole 40amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-SP&N Double Door Distribution Board 16 way each [CSR 34.17iv]
LED' FITURES & FANS : Supply & Erection of Durable LED Batten with High quality extruded aluminium Housing 40 Watt Input AC Frequency Hz +- 3% complete along with erection of the same with, testing, in all respect. complete in all respect as per approved /desired by the engineer in charge of work at site . The Certification and Specification of The Led fitting should be as approved by of O/o Advisior( Technical) Govt. of Punjab Letter No: AT/2021/GL/1410-1422 Dated 16-05-2021.Beside this the lighting manufacturer should have inhouse NABL accreted Lab.
Supply and erection of Ceiling Fan 1200mm (48") 3 star with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site.
Supply and erection of Heavy duty Exhust Fans 300mm 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site..
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 10.89 MB
TN.pdf
Tender Documents • 1.41 MB
BOQ_321518.xls
BOQ • 0.38 MB
Conditions.pdf
Tender Documents • 6.40 MB
Download all tender documents and submit your bid