| 1 | L1₹4.3 CrAccepted-AOC 1 VILLAGE JYOTISAR DISTT KURUKSHETRA | KURUKSHETRA | HARYANA | 136030 | ₹4.3 Cr | L1 | Accepted-AOC Tender Allotted |
| 2 | L2₹4.5 Cr+₹18.0 L (4.14%)Rejected-AOC WARD NO 2 DELHI ALWAR ROAD NUH MEWAT 122107 | NUH | MEWAT | HARYANA | 122107 | ₹4.5 Cr+₹18.0 L (4.14%) | L2 | Rejected-AOC 2nd Lowest |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical H NO 02 NEAR GOVT BOYS SR SEC SCHOOL 121102 | PALWAL | HARYANA | 121102 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹4.4 Cr
EMD Value
₹8.9 L
Closing Date
2 Nov 2023, 3:00 pmClosed
DIPENDRA RAJ SINGH
EE PHE Division No. 2 Palwal (P)
Estimate for providing water supply system in 194 Battalion RAF (Rapid Action Force)Bawana, CISF Camp at Village Indri and Indri village by installation of 11 No. tubewell,connecting pipeline and rising main, UGT, Pump Chamber, Pumping Machinery,
2023_HRY_319951_1
2023BC173F07 5598 46B5 932A F3DD5F3200B4559PUH
Open Tender
Civil Works
Works
365 days
INDRI
As per approved DNIT
2 documents required · 2 mandatory
₹15,000
₹8.9 L
Yes
19 Dec 2023
12 Oct 2023
2 Nov 2023
12 Oct 2023
2 Nov 2023
12 Oct 2023
Amount
Providing and Fixing Float operated water gauge 6` wide 15` height painted and marked with in feet bottom flange for fixing pulley on top with 10` i/d copper ball with steel wire rope complete in all respect
providing and fixing aluminum ladder 1` wide with 1` center to center aluminum rod of 20mm i/d complete in all respect (20` long)
Supply and errection of street light Lumination 2x28 watt energy saving fitting as per specification.
Supplying of cable of required size and length at BS as per site requirement.
Providing and fixing Electromagnetic type flow meter suitable to measure discharge 50 cum/hr. to 160 cum/hr. with electronic display unit having data logging facility and data downloading hand held computer with neccssary software with all required items such as flexible adaptors,rubber ring/gesket,nut bolts,MS fabricated expanders/reducers,wall mounted display including providing sun shade/rain shade,under ground cabling from the meter with G.I.Pipe protection,power connection, panel board earthing etc,as per specification and direction of Engineer-in charge complete in all respects.(make:-ABB,Crohnemarsal, EandH, Siemens, Ultra Sonic)
NS-Item:Designing, providing, fixing, commissioning and testing of GASEOUS CHLORINATION SYSTEM having capacity upto 2000 grams/ hrs. as designed having the control of gas upto 20th part of max. dose The complete system consists of (a)Vacuum regular (b)Measuring Glass Tube (c)Ejector (d) PF tubing (e)Spanner with cylinder opening kye (f)Amonia Gas(Liquid for leaking test (g)1` dia PVC pipe with PVC fitting,ball valves etc.(h)2 Nos chlorine Gas cylinder capacity 100 kg.dully certified and approved by BIS and Explosive Department Govt. of India (i)Electronic chlorine gas leak detector with sensor and hooter (j) Full face mask with canister.
Providing and fixing Electromagnetic flow Meter Line Size – DN150 Display : Digital Lining – PTFE Power supply : 230 VAC Electrode Material: SS316L Connection type: Flange end Outupt: RS485 and 4-20mA Remote display with 20 meter cable All accessories (Like UPS, Rubber gas kit, De-watering etc.) Make – KROHNE MARSHALL, Unitech, Siemens, Electronet etc complete in all respect as per analysis attached.
Providing and fixing Electromagnetic flow Meter Line Size – DN250 Display : Digital Lining – PTFE Power supply : 230 VAC Electrode Material: SS316L Connection type: Flange end Outupt: RS485 and 4-20mA Remote display with 20 meter cable All accessories (Like UPS, Rubber gas kit, De-watering etc.) Make – KROHNE MARSHALL, Unitech, Siemens, Electronet etc
Boring/excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/Boulders/any underground utility like foundation, water supply line coming in alignment or other underground obstruction under railway tracks Agra Delhi suitable for M.S Casing pipe of following sizes including caution and sign board complete in all respects. i) Boring 1232 mm dia insertion for 800 mm i/d M.S.
Providing and insertion of M.S. casing pipe (Fe-330 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS: 2062 of the following size cutting bevelling grinding and radio graphically welding of pipe as per IS-1182 complete in all respects including cartage to site of work and testing. ii) For 800 mm i/d M.S. casing pipe 16 mm thick
Providing and Insertion of water carrier pipe 720 mm o/d M.S. pipe 10 mm thick (Fe-330 grade) fabricated as per IS:-3589 of 1991, from steel plate conforming to IS: 2062, including inner lining by cement concrete mortar which shall be prepared from aggregates/sand and cement mixed in ratio 2:1 by weight with minimum, cement contents of 450 kg/m3 having strength of 25N mm2 after 28 days complete as per IS: 1916-1989 with latest revision, providing roller arrangement for smooth insertion and anchoring of pipe through out the length with HDPE spacers at a distance of 2 m apart to avoid contact of casing pipe and carrier pipe including cutting, jointing, Radiographic welding as per IS: 1182 Hydraulic testing complete in all respects including cartage upto site of work
Cleaning of surface of M.S. pipe (casing pipe and Carrier pipe) inner surface and outer surface by sand blasting at site to make the surface ready for P.U. coating/high built epoxy paint/polythene tap system complete in all respect.
Coating of outer surface and inner surface of casing pipe with epoxy paint for protection against corrosion complete in all respects
Coating of outer surface of water carrier pipe with bitumenous paint for protection against corrosion complete in all respects.
Coating of inner surface of casing pipe with Food grade epoxy paint confirming RDSO specification No. M and C/PCN/111/88 to dry film thickness of 250 micron
Providing and fixing H.D.P.E. spacer at a distance of 2 m apart to avoid contact of casing pipe and carrier pipe complete in all respects. i) For 1028 mm o/d M.S. pipe
Providing concrete block (1:11/2 :3) on both ends to plug annular space between casing and carrier pipe including cost of 5mm thick M.S. end plate complete in all respects. i) For 1232 mm o/d casing pipe
Ground probe radar survey to check any under ground obstruction before finalizing the alignment. Crossing of National Highway R.D. 1950 for 700 mm i/d Pipe.
Boring/excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/Boulders/any underground utility like foundation, water supply line coming in alignment or other underground obstruction under railway tracks Agra Delhi suitable for M.S Casing pipe of following sizes including caution and sign board complete in all respects. i) Boring 1024 mm o/d M.S. pipe 12mm thick casing pipe
Providing and fixing H.D.P.E. spacer at a distance of 2 m apart to avoid contact of casing pipe and carrier pipe complete in all respects. i) For 700 mm o/d M.S. pipe
Providing concrete block (1:11/2 :3) on both ends to plug annular space between casing and carrier pipe including cost of 5mm thick M.S. end plate complete in all respects. i) For 700 mm o/d casing pipe
Bidder Name
Amount
Rajesh Kumar(GSTN-NA)
Hamid Hussain, Contractor(GSTN-NA)
Hamid Hussain, Contractor
Hamid Hussain, Contractor
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .