Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹27.2 L+₹32,256.10 (1.20%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹28.0 L+₹1.1 L (4.15%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹32.0 L+₹5.1 L (19.1%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
26 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
CERTAIN MINOR WORKS AT LGJ MIL STN
2024_MES_686095_1
8935-32/GE/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender documents
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹59,000
Yes
21 Jan 2025
28 Nov 2024
28 Dec 2024
28 Nov 2024
26 Dec 2024
12 Dec 2024
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) and rubhis off from premises complete all as specified and directed by Engr-in-charge.
Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for and rubhish off from premises complete all as specified and directed by Engr-in-charge.
Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Dismantling of Brick tiles or terracing tiles, single layer on roofs and including rubbish off the premises complete all as specified and as directed by engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping and including rubbish off the premises complete all as specified and directed.
Surface excavation N.exc. (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavating over area n.exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Rolling and consilidation formation surface in cutting with powder roller exc 5 tonne and exc 8 tonne complete all as specified and as directed by Engineer-in-charge..
Material and labour for brick work with Fly Ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
M & L for broken stone Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed by Engineer-in-charge..
Taking down cement plaster from brick wall or concrete surfaces or ceiling including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
Material and labour for 150 mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and as directed by the Engineer-in-Charge.
M & L for forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com pound, Grade ‘A’ all as specified and as directed by the Engineer-in-Charge.
Finishing surface of concrete roads, pavements, by brooming complete all as specified and directed by the Engineer-in-Charge..
Forming Contraction joints 65mm deep x 10mm wide, filled with sealing compound, Grade A
S & F 80 mm bore galvanished steel water tubes, medium grade of pipe and necessary fitting/fluxure all as specified and as directed by the Engineer-in-Charge.
S & F for 50 mm Bore dia of Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Add to Ser item 18 for each additional 1.5m or part thereof in depth beyond the first 1.5 m complete all as specified and as directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning soft soil, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L for PCC 1:2:4 type B2 using 40mm graded aggregates as foundation complete all as specified and directed by Engr-in-charge.
M&L fly ash brick work with old size brick straight or curved on plan exc 6m mean radius half brick thick in CM 1:4 complete all complete and as specifed and directed.
M & L for PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) in coping for drain complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B1 using 20 mm graded aggregates as in benching / haunching of manholes including forming channels including necessary formwork etc complete all as specified and directed by Engr-in-charge.
M&L for reinforced cement concrete type B1 1:2:4 using 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, copings, bed plates,and the like including weathering, slightly rounded or chamfered angles and throating,incl formwork all as specified & directed. Note :- Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge.
M & L for 40 mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof Padding etc and slope 1:40 complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
M&L rendering 15 mm thick cement plaster on brick walls or concrete, surface in cm 1:6 on wall and surface to be finished even smooth without using extra cement complete all as specified & directed
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 on wall, finished fair even and smooth all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified & directed
Returning filling in incl spreading, levelling watering and well ramming in layer n.exc 25cm thick complete all as specified and directed.
M&L for sand filling under floor 25mm thick with washed and screened dry fine river sand including watering, well ramming and consolidation complete all as specified and directed .
Removing surplus soil to a distance n. exc 250 m n. exc 500 m and depositing where directed at level above the starting point complete all as specified and directed by Engr-in-Charge
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge
M&L for broken brick of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.18 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engneer -in-Charge
M&L for 75 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
M&L for reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregrate in Chajjas; complete all as specified and directed by Engr-in-charge. Note : Reinforcement shall be measured and paid seperately.
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in kerb stones of size 300 mm x 300 mm x 100 mm with plain fair faces, including chamfers, weathering, throating etc setting in CM 1:4 complete all as specified and directed.
M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge. Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching.(ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
M & L for flush pointing, to bricks in cement mortar 1:3 laid flat or brick tiles in paving in floor, roof etc
M&L 40mm thick brick tiles laid flat on cement concrete & joints grouted flush in cement mortar (1:3) bedded over 15mm thick cement morter (1:6)mixed with 5% of crude oil by weight of cement on complete all as specified and directed by Engr-in-Charge.
All as per srl item No 46 above but except tiles complete all as specified and directed by Engr-in-Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compa ction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engr-in-charge.
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, and like rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engr-in-Charge.
Material and labour for 40 mm thick cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in floor finished even and smooth without using extra cement laying in alternate bays complete all as specified and as directed by the Engineer-in-Charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as directed.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as directed.
M&L for 40mm thick damp proof course in cement concrete 1:2:4, type B-0, 12.5 mm graded stone aggregate to horizontal or vertical surfaces including necessary formwork complete all as specfied and directed by Engr-in-Charge.
S & F Steel work in tubular/hollow section in trusses, rafter, purline, post etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed by Engineer-in-charge.
S&F for TMT bars (Fe-500D) 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
S&F for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of cement base paint complete all as specified & directed
M&L for complete removal of existing treatment and applying two coats of cement base paint on wall surfaces including preparation of surface complete all as specified and directed by Engineer-in-charge.
Material and labour for preparing newly plastered or pointed surface of wall by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
M&L for two coats of white wash on old plastered surfaces on ceiling incl preparation etc. complete all as specified and directed.
M&L for two coats of acrylic distemper on newly plastered surfaces of walls over and including one coat of primer and 3mm thick wall care putty including preparation of surfaces complete all as specified and directed.
M&L for complete removal of existing treatment and two coats of acrylic distemper on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Vitreous China urinals, half stall complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; grating and Union for discharge pipe complete all as specified and directed.
S&F vitreous china wash hand basin coloured Flat back of size 580x450mm, including 32mm dia chromium plated waste coupling long screwed shank and fly nut, flanged end bedded in red led cement and other end fixed and PVC waste pipe including cutting for and pinning in ends of brackets in CM 1:3 all as specified .
Supply & fixing pillar tap swan neck type cast copper alloy with capstan head, chromium plated, fancy type screwed down, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
S & F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe, (miniumum weight 60 grm) all as specified and directed
S&F angle valve/stop valve 15 mm bore fancy type, cast copper alloy, chromium plated screwed down high pressure , screwed both ends for iron pipe or for union, complete, all as specified & directed by Engineer-in charge
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints, laid in trenches or in floors all as directed.
S&F 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints, laid in trenches or in floors all as directed.
S&F in repair PVC (SWR) floor trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed.
S&F for Rotational moulded polythene water storage tank 500 ltr capacity vertical with closed top, ISI marked hoisted and fixed in position all as specified in SSR part-I. complete all as specified and directed..
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and conforming to Fe 290 -W (Gde- E- 165) quality- A complete all as specified and directed
S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Roof trusses (framed) , trussed , purlines, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or Flat section) including distance pieces , cleats etc Fe-290 (Gde E-165) Quality `A' complete all as specified and directed by Engr-in-charge.
S & F Mild steel screw bolts (machine made) of any dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long
M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of new or previously untreated surfaces priming with one coat of read oxide & finish with two coats of synthetic enamel paint ordinary tint all as spefified and directed by Engr-in-Charge.
M&L for preparation of old steel surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
S&F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 152mm at top and 102mm x 289mm at bottom, class 10, complying with requirements of IS-1678-1998, errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles and numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed.
Supply and fixing street light bracket made out of 40 mm dia GI tubing light grade made to shap 1.5 Mtr long with fixing arrangement for LED fittings duly painted with two coats of synthetic aluminium paint over a coat of primet including MS clamps and back plates fabricated from steel section including nuts, bolts washer etc complete all as specified and directed
M&L for Pre-cast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in kerb stone with plain fair faces, smooth finish, including chamfering, weathering, throating etc set in cement mortar 1:4 including excavtion and earth work for embedding kerb stone at a depth as directed and temping around kerb stone and removal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed .
M&L sand cushioning with dry and clean locally available sand for under ground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note : Punned thickness shall be considered for payment purpose)
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Supply and laying in replacement LT XLPE cable 1100 Volt grade 35 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct complete including taking out of existing cablel all as specified and directred. Excavation and earthwork shall be paid and measured separately
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 10 Sqmm 4 Core including making necessary electrical connections by using AI thimbles of appiropriated size complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ..
Supply and laying GI tubing light grade 40 mm dia for protection of cable/laid in trenches/fixed on pole/walls/laid under floors/roads includign fitting complete all as specified and directed.
M & L for Cross arms, bracings, Stiffeners supports, D-clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminimum paint complete all as specified and directed.
Supply and fixing in repair LT cable junction box, dust and water proof (IP65), out door type, made out of Polycarbonate with glass fiber re-inforced, size of box 250 x 200 x 100 mm with swiveling cover and locking clamp, pole mounting, consisting of aluminium bus bar strip 150mm x 20mm x 3mm, 4 Nos mounted on PVC insulator and provision of incoming/outgoing cables with grommets, including in built 6Amp MCB, SP, 9/10KA one No complete all as specified and as directed by Engineer-in-charge.
Supply and fixing PVC insulated stranded aluminium conductor cable PVC sheathed 1.5 Sq.mm flat or circular twin core with & including PVC heavy duty conduit of sixe 20 mm bore fixed to poles with suitable size clamps for connection of street light fitting from junction boxes complete all as specified and directed Note : MS Clamps shall be measured and paid separately
Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation fof poles/struts/stays etc filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in foundation fof poles/struts/stays etc filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
M & L for plain cement concrete 1:2:4 type B-1, using 20 mm graded crushed stone aggregate as in coping & bed block etc including weathering, slightly, rounded or chamfered angles and throating as directed necessary form work complete all as specified and directed. Note : for item No 96 to 97 volume of pole/strut/ stay embedded in concrete shall be deducted for the purpose of payment
M & L for danger notice plate of size 25 cm x 20 cm made out of MS sheet 1.6 mm thick, vitreous enameled white, with letters figured and convertional skull and bones in signal red colour and fixed with MS clamps, bolts, nuts of approved size, for HT poles compplete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI Medium grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe Medium Grade for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
M&L for earthing with galvanized steel earth plate electrode 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by mean of nuts bolts and washers of steel or GI, 20mm dia GI medium grade watering pipe with funnel and wire mesh, including of provision of earth lead protection by 40 mm bore GI light grade, PCC pit 1:3:6 type C2 (using 20 mm graded curshed stone aggregate) with pit cover made of RCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate and reinforcement with 80 mm dia @100 C/C/ bothways and frame, with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, earth work in any type of soil, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge.
S & F galvanised iron strip 32 mm x 6 mm with saddles and fixing screws etc for down conductor complete all as specified and directed by Engineer-in-Charge.
S & F air termination, single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed by Engineer-in-Charge.
Test point terminal block made of gun metal or phosphorus bornze size 75 x 75 x 25 mm drilled and scrwed including 3 Nos 8 mm dia 25 mm ling hex, Head screw complete all as specified and directed by Engineer-in-Charge.
S & F in repair for feeder pillar box out door type made out of 3 mm thick plain MS sheet of size 0.90 m x 0.45 m x 0.90 m supported on angle iron of size 40 x 40 x 6 mm including necessary PCC for grouting. The panel shall comprise of (a) 4 Nos aluminium bus bar of 300 Amp rating (b) MCCB3- pole 415 Volt, 200 Amp, ruputing capacity 10 KA-01 No (c) MCCB 3-pole 415 Volt, 100 Amp 25 KA-01 No (d) MCB SP 5-32 Amp-06 Nos
Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB amp of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed Point wiring for one light point controlled by one way switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
Supply and fixed modular switch 6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.
Supply and fixed modular socket outlet multipurpose type 6 Amp, flush type (2module) complete all as specified and as directed by Engineer-in - charge
S & F aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc for down conductor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing lamp holder polycarbonate cased body (B22 base), top line series, with back plate complete all as specified and as directed.
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp complete all as specified and as directed.
Supply and fixing energy efficient LED security light fitting of 90W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25 mm dia (medium quality ISI marked), for independent circuit for DB to aviation light including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 6 to 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge
Supply and laying and commissioning LT XLPE cable 1100 Volt grade 50 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 7098 (Part-I) laid in trenches/along poles/ through pipe/through duct complete including taking out of existing cablel all as specified and directred. Excavation and earthwork shall be paid and measured separately
Supply and fixing blanking plate suitable for any type of DB complete all as specified and as directed by Engineer-in-charge.
Supply and fixing ventilating Air fresher Fan of size 250mm sweep, AC single phase 230V 50Hz, 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with PVC Sheathed copper conductor flexible cable of suitable size drawn in flexible PVC conduit from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge. Note:- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
Suply and fixing medium grade glavnized pipe 25 mm dia with all fitting laid in trenches complete all as specified and directed by Engr-in-Charge.
Supply and fix stop valve , screwd 25 mm (1") dia pipe complete all as specified.
Cutting existing DI pipe 150 mm dia, opening the dead plate and fixing of new GI pipe complete all as specified.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .