| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.9 L+₹2.0 L (29.6%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.0 L+₹3.1 L (45.5%)Rejected-Finance RZB 69 GALI NO 5 RAJ NAGAR PART 1 WEAT DELHI DELHI 110045 SOUTH WEST DELHI DELHI 110045 UDYAM DL 10 0018772 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance L3 | |
| 4 | L4₹11.3 L+₹4.4 L (64.2%)Rejected-Finance 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L4 | Rejected-Finance L4 | |
| 5 | L5₹13.2 L+₹6.3 L (91.8%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹19.8 L
EMD Value
₹39,600
Closing Date
15 Sept 2021, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR TO ROOF AND ALLIED WORKS AND CLEANING REPLACEMENT OF SERVICE WATER TANKS AND PERIODICAL SERVICES AND WELCOME MAINTENANCE AT AF STN DADRI
2021_MES_471201_1
GE (FBD)/AF-37/2021-2022
Open Tender
Civil Works
Item Wise
180 days
AF STATION DADRI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF FARIDABAD
₹39,600
Yes
14 Oct 2021
27 Aug 2021
22 Sept 2021
27 Aug 2021
15 Sept 2021
3 Sept 2021
28 Aug 2021 - 2 Sept 2021
Amount
Dimolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
M&L for RCC 1:2;4 B0 (using of 12.5 mm Stone Aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and chajjas complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M&L for 10 mm dia and over TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc complete all as specified and directed by Engineer-in-Charge.
M&L for 6 to 8 mm dia TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster from brick or stone masonry or concrete surfaces and hacking for key and scrubbing down with water etc all as specified (Note:- Taking down Plastering work to be done upto height of 30 mtr for RCC OHT as per site requirement.) complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 on stone masonary or surface other than fair face of brick works etc or similar surfaces etc including with mixing of water proofing liquid of Dr. fixit Qty as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge.
M&L 15 mm thick rendering in cm 1:6 on brick surfaces or concrete surfaces finished even and smooth without using extra cement incl mixing of water proofing liquid of Dr. fixit as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge. (Note:- Plastering work to be done upto height of 30 mtr for RCC OHT as per site requirement.)
M&L for rendering 10mm thick in CM 1:3 on concrete surface in ceillings etc including with mixing of water proofing liquid of Dr. fixit as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls over a coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
M&L two coat of oil bound distemper after 3mm Birla/JK wall care putty on new plastered surfaces including necessary prepararion complete all as specified and directed by Engineer-in-Charge.
M&L three coat of white wash on new surfaces on ceiling including necessary prepararion complete all as specified and as directed by Engr-in-Charge..
Taking down existing water proofing treament any nos of layers and of any description, incl.demolition and taking off PCC padding/plaster on RCC slab,also including removing of bitument coating to show the concrete surface to its true colour and roughening etc and also removing the debris outside the MOD land complete all as specified and directed by Engineer-in-Charge.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 including macthing existing surfaces complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) on roof padding avg. thicknessof 40mm in slope finished even and fair complete all as specified and directed by Engineer-in-Charge.
M & L for 20 mm thick Screed bed in cement mortar 1:3 mixed with integral water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge.
M & L for applying cold bituminous oil based primer IS No. 3383 @ 250 gms/sqm and laying APP modified membarane with non woven polyester reinforcement mat (concrete core) not less than 3 mm thick & not less than 3.5 kg /sqm, the over the lap otching shall be 100 mm on length side & 100 mm on widthe side all as per manufacture's instruction complete all as specified and directed by Engineer-in-Charge. Note: Supply only integral water proofing compound shall be measured and paid separately.
Supply only integral water proofing liquid ( ISI marked) complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel water tubing and connection incl cleaning for refixing or removal to stores for following bore:- (a) 15mm
All as per item No 19 here in above but 20mm complete all as specified and directed by Engineer-in-Charge.
Refixing old steel tubing and connections in new or old position on wall, ceiling, floor etc of 15 mm dia complete all as specified and directed by Engineer-in-Charge.
Refixing old steel tubing and connections in new or old position on wall, ceiling, floor etc of 20 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor in following bore of tube complete all as specified and directed by Engineer-in-Charge :- (a) 15mm
All as per item No 23 here in above but 20mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20 MM Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair and complete all as specified and directed by Engineer-in-Charge.
S&F in repair small fittings of galvanized iron heavy grade such as socket, elbow , nipple of different Tee, chuknet of any size, union reducer, Float valve etc for 15 mm bore 20 mm bore pipe complete all as specified and as directed by Engineer-in-Charge
S& Fix in repair 15 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair and complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair and complete all as specified and directed by Engineer-in-Charge.
S&F in repair rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge as per SSR Pt- I
S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge as per SSR Pt- I
Cleaning and removal all scale and dirt, etc, from tanks and mouth of circulating pipes, etc exc 250 & n.exc500 litres capacity including to be write the date of cleaning with synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Cleaning and removal all scale and dirt ,etc ,from tanks and mouth of circulating pipes ,etc exc 500 & n.exc 1000 litres capacity including to be write the date of cleaning with synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old previously decorated surfaces by brooming down or steel wire brushes, scrapping down smoke soot, moulds, efflorescent salts etc and applying one coat of white wash on walls complete all as specified and directed by Engineer-in-Charge.
All as per item No 33 above but on ceiling complete all as specified and directed by Engineer-in-Charge.
All as per item No 33 above but one coat of oil bound distemper on walls complete all as specified and directed by Engineer-in-Charge.
All as per item No 33 above but two coat of oil bound distemper on walls complete all as specified and directed by Engineer-in-Charge.
All as per item No 33 above but one coat cement base paint on walls complete all as specified and directed by Engineer-in-Charge.
M &L for Preperation of old Apex painted surfaces and applying One coat of external emulsion paint (Apex) all as directed by Engr in charge .
M &L for complete removal of existing treatment and applying two coat of external emulsion paint (Apex) over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated wooden surfaces and applying one coat of synthetic enamel paint over 10 cm in width or girth complete all as specified and directed by Engineer-in-Charge.
All as per item No 40 above but on steel surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for applying 3mm thick wall care putty on ceiling, deep scraped surfaces or undulated surfaces in patches and making good even and smooth rubbing with sand paper etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster from brick or stone masonry or concrete surfaces and hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick plastering with cement mortar 1:6 finished fair and even on brick masonry complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick plastering with cement mortar 1:4 finished fair and even on brick masonry complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment by washing, rubbing down and stopping of distempered and painting surfaces etc and applying two coats of oil bound distemper on walls over a coat of 3 mm thick wall care putty complete all as specified and directed by Engineer-in-Charge. (Note - work shall be got executed through skilled representative of manufacture company)
M&L for complete removal of existing treatment by washing, rubbing down and stopping of distempered and painting surfaces etc and applying two coat of cement base paint on walls over a coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
M&L for obliterating old writing of any description n.exc 0.1 sqm with paint to match existing work complete all as specified and directed by Engineer-in-Charge.
M&L for writing letters or figures (Block, Roman, Italic or Indian ) not exc 30 cm high complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-1( using 20 mm graded stone aggregate) in filling the holes, cutting, etc necessary from work complete all as specified and directed by Engineer-in-Charge.
S&F sink with drain board in repair made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
S & F Stainless steel plate rack of size 900x600x450 mm Approved make complete all as specified and directed by Engineer-in-Charge.
36SHRI RADHEY ASSOCIATES
M/S Ashoka Engineers and contractors
s r enterprises
OM SAI ASSOCIATES AND DEVELOPERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .