Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.0 CrAccepted-AOC | ₹12.0 Cr Quoted ₹12.8 Cr | 1 | Accepted-AOC 1 |
| 2 | Rejected-Technical PROP AJAY SINGH SIKARWAR VILLEGE POST AMAYAN TAHSIL MEHGAON DISTT BHIND M P 477227 | BHIND | MADHYA PRADESH | 477227 | - | - | Rejected-Technical due to not submitted required document |
| 3 | Rejected-Technical 102 114 MOHADDIPUR DISTRICT GORAKHPUR UTTAR PRADESH | GORAKHPUR | UTTAR PRADESH | 273001 | - | - | Rejected-Technical due to not submitted required document |
Tender Value
₹15.2 Cr
EMD Value
₹30.4 L
Closing Date
22 Jun 2024, 12:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer Gorakhpur Circle PWD Gorakhpur
Construction work of administrative building for police station Siktaur Sonbarsa by upgrading the reporting police post Siktaur Balapar in Sonbarsa area under police station Chiluwatal in Gorakhpur district Lot No 2 of 4
2024_CEGKP_928325_2
3665/135C-Gorakhpur Circle/2024 Dated 06-06-2024
Open Tender
Civil Works
365 days
Gorkahpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,714
₹30.4 L
11 Dec 2024
14 Jun 2024
22 Jun 2024
14 Jun 2024
22 Jun 2024
14 Jun 2024
Amount
Sub Head - I Earth Work Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil DSR-2.8.1 (GST shall be paid Extra)
Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. DSR-2.27 (GST shall be paid Extra)
Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. DSR-4.1.8 (GST shall be paid Extra)
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos /Lindane E.C. 20% with 1% concentration DSR-2.35.3.1 (GST shall be paid Extra)
Sub Head - II Reinforced Cement Concrete FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for (a) Foundations, footings, bases of columns, etc. for mass concrete 5.9.1 (GST shall be paid Extra)
(b) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 5.9.2 (GST shall be paid Extra)
© Suspended floors, roofs, landings, balconies and access platform 5.9.3 (GST shall be paid Extra)
(d) Lintels, beams, plinth beams, girders, bressumers and cantilevers 5.9.5 (GST shall be paid Extra)
(e) Columns, Pillars, Piers, Abutments, Posts and Struts 5.9.6 (GST shall be paid Extra)
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) DSR 20.1.1 (GST shall be paid Extra)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Single pile upto 50 tonne Safe capacity Intial test D.S.R.-20.6.1.1 (GST shall be paid Extra)
Routine Test D.S.R.-20.6.1.2 (GST shall be paid Extra)
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.1.1 (GST shall be paid Extra)
All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.2.1 (GST shall be paid Extra)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more (DSR 5.22.6) (GST shall be paid Extra)
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). DSR-4.11 (GST shall be paid Extra)
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. DSR-4.13 (GST shall be paid Extra)
Sub Head - III Brick work Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 (GST shall be paid Extra)
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). DSR-6.47 (GST shall be paid Extra)
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. DSR-6.38 (GST shall be paid Extra)
Class M-150 brick work in 1:4 cement and coarse sand of 2.25 coarseness modulus mortar in super-structure. Above plinth level up to floor two level (up to two storey) including necessary cutting and molding of brick work as required and also including honey combed brick work in thickness of wall more than 12cms. DSR-6.4.1 (GST shall be paid Extra)
Sub Head - III Door Window & Ventilator Works Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including ISI marked Stainless steel butt hinges with necessary screw. (Excluding cost of fitting) 35 mm thick (a) Single leaf DSR-9.20.2 (GST shall be paid Extra)
(b) Double leaf DSR-9.20.2+9.26 (GST shall be paid Extra)
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). D.S.R.-9.23 (GST shall be paid Extra)
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) D.S.R.-9.22.1 (GST shall be paid Extra)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Analyses rate AR - VI (GST shall be paid Extra)
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). D.S.R.-21.17 (GST shall be paid Extra)
Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge D.S.R.-9.143 (GST shall be paid Extra)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws DSR-9.21.3 (GST shall be paid Extra)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes DSR-10.30.2 (GST shall be paid Extra)
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm DSR 9.97.2 (GST shall be paid Extra)
150x10 mm DSR 9.97.4 (GST shall be paid Extra)
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm (DSR 9.165.1) (GST shall be paid Extra)
100 mm DSR 9.165.2 (GST shall be paid Extra)
75 mm DSR 9.165.3 (GST shall be paid Extra)
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm DSR-9.96.2 (GST shall be paid Extra)
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90 mm DSR-9.70.1 (GST shall be paid Extra)
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete (DSR-9.82) (GST shall be paid Extra)
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. DSR-9.84 (GST shall be paid Extra)
Carbon Steel galvanised (min 5 micron) dash fastner (min 5 micron) of 10 mm dia double threaded 6.8 grade counter sunk head screw comprising of 10 mm dia polyamide PA 6 grade sleave. Size 10 mm x 120 mm DSR-2508 (GST shall be paid Extra)
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Double strip (horizontal type). DSR-9.114.2 (GST shall be paid Extra)
Sub Head - V Finishing work Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. DSR 13.78 (GST shall be paid Extra)
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. DSR 13.78 (GST shall be paid Extra)
12mm cement plaster . 1 cement : 6 coarse sand. (DSR -13.4.2) (GST shall be paid Extra)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). (DSR 13.47.1) (GST shall be paid Extra)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. DSR 13.83.2 (GST shall be paid Extra)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80) (GST shall be paid Extra)
Sub Head - VI Flooring work 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. DSR-11.5 (GST shall be paid Extra)
Providing and laying vitrified floor tiles I.S.I. brand in different (thickness specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) (DSR -11.41.2) (GST shall be paid Extra)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Size of Tile 600x600 mm) (DSR -11.41.2) (GST shall be paid Extra)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red. Area of slab upto 0.50 sqm (DSR 8.2.2.1) (GST shall be paid Extra)
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR 11.37) (GST shall be paid Extra)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 8.31) (GST shall be paid Extra)
Sub Head - VII Waterproofing work Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. The whole terrace so finished shall be flooded with water for aLminimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR-22.7.1 (GST shall be paid Extra)
Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (DSR-22.5) (GST shall be paid Extra)
Sub Head - V Miscellaneous Work Supply and stacking of Fly ash conforming to IRC- 58 at site, including carriage, loading , unloading & stacking up to any lead (measured stacks will be reduced by 20% for payment). (DSR-2.37) (GST shall be paid Extra)
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. (DSR-2.38) (GST shall be paid Extra)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (DSR-10.28) (GST shall be paid Extra)
Construction of drain along with apron (A.R.-II) (GST shall be paid Extra)
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment DSR 11.19.4 (GST shall be paid Extra)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes DSR 10.16.3 (GST shall be paid Extra)
Supply and Installation of polycarbonate multi-layered system, a complete assembly of extruded multilayer UV protected polycarbonate panels. Co-extruded UV protected polycarbonate panel system of min 18 mm thick panel of minimum 1200 mm width for bigger spans and minimal junctions for better performance. Panels shall have minimum seven layers Within translucent clear and opaque combination to achieve required Lux Levels of light and angular daylight throughout day with better shading and ambient temperature with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical offset standing seam at both sides of the panel. Panels have to be fixed on Purlin with snap on connectors with grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate Panel which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 2.0 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings.Approved Make: DPI Daylighting MR (GST shall be paid Extra)
Providng and fixing of G.R.C. Jali MR (GST shall be paid Extra)
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” DSR-25.2 (GST shall be paid Extra)
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. DSR-25.3 (GST shall be paid Extra)
INTERNAL WATER SUPPLY AND SANITATION SANITARY FIXTURES & ACCESSORIES : I Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required (A) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests DSR 17.1.1 (GST shall be paid Extra)
(B) Same as above but for European type W.C. pan with white plastic seat and lid.Make- Cera,Hindware. (GST shall be paid Extra)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require (a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. DSR 17.7.4 (GST shall be paid Extra)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board of size 510x1040x200mm DSR 17.10.1.1 (GST shall be paid Extra)
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Felxible pipe (A) 40mm dia DSR 17.28..3 (GST shall be paid Extra)
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 (GST shall be paid Extra)
Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. (A) 15mm nominal bore DSR 17.16A (GST shall be paid Extra)
Providing & fixing 60x2cm. C.P. brass towelrail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screw. ESSCO AEC-1111 DSR 17.73.2 (GST shall be paid Extra)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore DSR 18.53.1 (GST shall be paid Extra)
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameter DSR 18.22.1 (GST shall be paid Extra)
SOIL WASTE & VENT PIPES AND FITTINGS - II Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (Internal Work) Expansion on Wall 32 mm dia nominal bore. (medium duty) (GST shall be paid Extra)
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. 32 mm diameter pipe. (GST shall be paid Extra)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes DSR 18.7.3 (GST shall be paid Extra)
40 mm nominal outer dia Pipes DSR 18.7.4 (GST shall be paid Extra)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes DSR 18.8.1 (GST shall be paid Extra)
20 mm nominal outer dia Pipes DSR 18.8.2 (GST shall be paid Extra)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. (a) 110mm diameter DSR 12.41.2 (GST shall be paid Extra)
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (a) 110mm DSR 12.43.2 (GST shall be paid Extra)
WATER SUPPLY PIPES AND FITTINGS - III Providing & fixing CPVC pipes complete with CPVC fittings & clamps including cutting & making good the walls etc. (internal work) (I) Exposed on wall ( a) 25mm dia nominal bore (medium duty) DSR 18.8.3 (GST shall be paid Extra)
(B) 20mm dia nominal bore (medium duty) DSR 18.8.2 (GST shall be paid Extra)
Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. (II) (a) 15mm dia nominal bore DSR 18.40.1 (GST shall be paid Extra)
(b) 20mm dia nominal bore DSR 18.40.2 (GST shall be paid Extra)
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. (a) 15mm nominal bore DSR 18.21.2.1 (GST shall be paid Extra)
Providing & fixing CP brass short body of approved quality conforming to IS 8931 (a) 15mm nominal bore DSR 18.49.1 (GST shall be paid Extra)
Providing and fixing gun metal gate valve with wheel of approved quality. (b) 25mm dia nominal bore DSR 18 17.1 (GST shall be paid Extra)
Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (a) 15mm nominal bore DSR 18.51.1 (GST shall be paid Extra)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete (a) 20 mm nominal bore DSR 18.18.2 (GST shall be paid Extra)
b) 25 mm nominal bore DSR 18.18.3 (GST shall be paid Extra)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. a) Circular Tank DSR 18.48 (GST shall be paid Extra)
SCHEDULE OF QUANTITIES FOR INTERNAL SEWERAGE SYSTEM - IV Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work a) 110mm diameter DSR 18.9.9 (GST shall be paid Extra)
(b) 160mm diameter DSR 18.9.10 (GST shall be paid Extra)
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. (a) 110mm diameter S.W.R. Pipe dsr 19.2.1 (GST shall be paid Extra)
(b) 160mm diameter S.W.R. Pipe dsr 19.2.2 (GST shall be paid Extra)
Providing and fixing square mouth UPVC S.W.R. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. a) 150 x 110 mm. size P type With Sewer bricks conforming to IS : 4885 DSR 19 4.2.2 (GST shall be paid Extra)
Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80X50cms including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 7.5 (i) For Sewer Line DSR 19.7.1.1 (GST shall be paid Extra)
Extra for depth for manholes Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 19.8.1.1 (GST shall be paid Extra)
EXTERNAL SEWERAGE WORK Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. (a) Pipes 80mm to 300mm diameter. dsr 2.10.1.2 (GST shall be paid Extra)
Providing, Fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS:13592 suitable for rubber ring joints for horizontal pipes including all necessary specials and fittings (confirming to IS:14735) i.e, bends tees junctions (with or without doors). reducers WC connectors, couplers, cowels, clamps & hangers rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamps & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382 (Make :Supreme /Finolex / Prince) (Pipe support: Intellotech / Easyflex / Chilly.The Pipes will be supported by either rubber lined G.I. U strip clamps on 50X50X5 mm MS slotted angle duly painted (for a group of pipes) or G.I. rubber lined split clamp (for independent pipes). The cost will include all supported arrangements. The Work includes cutting holes in wall/ floor/ slabs and making good the same with cement concrete 1:2:4 complete as required. The work include commissioning of all pipes lines as per drawings and specification and as directed by engg. in. 110 mm dia MR (GST shall be paid Extra)
75 mm dia (GST shall be paid Extra)
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. (a) 150mm diameter S.W. Pipe dsr 19.2.2 (GST shall be paid Extra)
Constructing brick masonry manhole with F.P.S. bricks in cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard designInside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimension total wt. of cover & frame to be not less than 38 kg (wt. of cover 23 kg and wt. of frame 15 kg) dsr 19.7.1.1 (GST shall be paid Extra)
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) dsr 19.7.2.1 (GST shall be paid Extra)
Extra for depth for manholes Size 90x80 cm DSR 19.8.1.1 (GST shall be paid Extra)
Size 120x90 cm DSR 19.8.2.1 (GST shall be paid Extra)
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design DSR 19.15.1 (GST shall be paid Extra)
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type DSR 19.4.3.1 (GST shall be paid Extra)
CONSTRUCTION OF SEPTIC TANK (100 USERS) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. In all kind of soil DSR 2.8.1 (GST shall be paid Extra)
Extra additional lift above 1.5 m DSR 2.26.1 (GST shall be paid Extra)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 4.1.8 (GST shall be paid Extra)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.1.1 (GST shall be paid Extra)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster. DSR 13.9.2 (GST shall be paid Extra)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate DSR-11.3.1 (GST shall be paid Extra)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slabs DSR 5.3 (GST shall be paid Extra)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (Plinth Beam) DSR 5.1.2 (GST shall be paid Extra)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform DSR 5.9.3 (GST shall be paid Extra)
Lintels, beams, plinth beams, girders, bressumers and cantilevers DSR 5.9.5 (GST shall be paid Extra)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.6 (GST shall be paid Extra)
Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. DSR 19.15.1 (GST shall be paid Extra)
Providing and fixing 150 mm S.C.I. tee at the inlet and outlet of septic tank. DSR 7087 (GST shall be paid Extra)
Providing & fixing 75mm dia vent pipes. DSR 17.35.2.2 (GST shall be paid Extra)
Providing & fixing of 75mm dia cast iron terminal guard. DSR 17.56.2.2 (GST shall be paid Extra)
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter DSR 19.19.2.2 (GST shall be paid Extra)
L.D. -2.5- Circular shape 450mm internal diameter DSR 19.19.1.3 (GST shall be paid Extra)
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 19.32.1 (GST shall be paid Extra)
RECHARGE WELL Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 1.5m depth DSR-2.8.1 (GST shall be paid Extra)
In all kind of soil upto 1.5m to 3.0m. Depth DSR-2.8.1+2.26.1 (GST shall be paid Extra)
In all kind of soil upto 3.0m to 4.5m. Depth DSR-2.8.1+2.26.1*2 (GST shall be paid Extra)
In all kind of soil upto 4.5m to 6.0m. Depth DSR-2.8.1+2.26.1*3 (GST shall be paid Extra)
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. (DSR-4.1.8) (GST shall be paid Extra)
M-150 brick work in 1:4 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. DSR 6.4.1 (GST shall be paid Extra)
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. DSR 5.3 (GST shall be paid Extra)
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. DSR-5.22.6 (GST shall be paid Extra)
12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 4 coarse sand DSR-13.4.2 (GST shall be paid Extra)
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar DSR 19.15.1 (GST shall be paid Extra)
Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 560mm internal diameter 19.19.2.2 (GST shall be paid Extra)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. DSR 23.1.1.1 (GST shall be paid Extra)
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia DSR 23.4.2 (GST shall be paid Extra)
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.DSR 23.5 (GST shall be paid Extra)
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. DSR 23.6 (GST shall be paid Extra)
Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. DSR 23.7 (GST shall be paid Extra)
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. (GST shall be paid Extra)
Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mm diameter DSR 2.10.1.2 (GST shall be paid Extra)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :(a) 150mm diameter DSR 19.6.2 (GST shall be paid Extra)
Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameter DSR 19.3.2 (GST shall be paid Extra)
NON D.S.R ITEMS Construction of Brick massonary INSPECTION chamber 60x60x60 cm with bricks class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI Cover with frame light weight complete as per design .with FPS bricks AR inspe (GST shall be paid Extra)
BOUNDARY WALL Earth work in excavation in trenches for foundations and pipes cables etc in ordinary soil (loan clay or sand) including lift upto 1.5 m, lead upto 50 m and dressing of sides and ramming of bottom and disposal of surplus excavated earth as directed by the Engineer- in- charge with in a lead of 50m .(Including royalty). DSR-2.8.1 (GST shall be paid Extra)
Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 stone grit 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. DSR-4.1.8 (GST shall be paid Extra)
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) DSR 20.1.1 (GST shall be paid Extra)
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3,(1cement :1.5 corse sand 3 grit) in Beam excluding supply of reinforcement and its fixing and bending but including its fixing and binding the same necessary with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not be less than M-20. DSR 5.3 (GST shall be paid Extra)
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3,(1cement :1.5 corse sand 3 grit) in Raft foundation excluding supply of reinforcement and its fixing and bending but including its fixing and binding the same necessary with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not be less than M-20. DSR-5.1.2 (GST shall be paid Extra)
R.c.c. work with cement approved coarse sand and 2 cm. (3/4") guage approved stone ballast in the proportion 1:1.5:3,(1cement :1.5 corse sand 3 grit) in Column excluding supply of reinforcement and its fixing and bending but including its fixing and binding the same necessary with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not be less than M-20. DSR 5.2.2 (GST shall be paid Extra)
Class 150 brick work in 1:4 cement and corse sand of 2.25 fineness modulus mortar in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honey combed brick work in thickness of wall more than 11.5cms. PWD-6.4.1 (GST shall be paid Extra)
Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. DSR 5.22.6 (GST shall be paid Extra)
12 mm cement plaster in single coat on fair side of single or half brick wall for interior plastering up to floor two level including brick wall for interior plastering upto floor two level including internal rounded angles chamfers, and / or rounded angles not exceeding 80 mm in girth and finished even and smooth No. extra for mixing any additive.(1)1 cement : 6 Coarse sand DSR-13.4.2 (GST shall be paid Extra)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). (DSR 13.47.1) (DSR 13.47.1) (GST shall be paid Extra)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80) (GST shall be paid Extra)
M.s work in. grill DSR 10.25.1 (GST shall be paid Extra)
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture DSR 13.48.3 (GST shall be paid Extra)
C.C. ROAD WITH BRICK EDGING Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in- charge. All kinds of soil (DSR-2.6.1) (GST shall be paid Extra)
Providing and laying in cement concrete 1:4:8 (1 cement : 4 fine sand : 8 graded bricks aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. (DSR-4.1.8) (GST shall be paid Extra)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:1:6 (1 cement : 6 sand) DSR -6.1.2 (GST shall be paid Extra)
P/L in cement concrete 1: 2: 4 (1 Cement : 2 coarse sand : 4 graded stone grit 20mm nominal size and curing complete including cost of form work for fixing of hold fasts including of supply of all materials labour T&P etc.required for proper completion of work. Strength should not be less than M-200. (DSR -4.1.3) (GST shall be paid Extra)
Providing and laying in position bitumen hot sealing compound for expansion joints etc. mr Using grade 'A' sealing compound. (GST shall be paid Extra)
ENTRANCE GATE Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. DSR-2.6.1 (GST shall be paid Extra)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40 mm nominal size) (DSR-4.1.8) (GST shall be paid Extra)
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) DSR 20.1.1 (GST shall be paid Extra)
R.C.C. work in R.C.C. Raft foundation and footing with approved stone ballast.(Using 1:1.5:3 Mix concrete) DSR 5.1.2 (GST shall be paid Extra)
R.C.C. work in R.C.C. columns in 1:1.5:3 having strength not less than M-20. DSR 5.2.2 (GST shall be paid Extra)
P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. DSR-5.22.6 (GST shall be paid Extra)
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement : 6 coarse sand) DSR-13.5.2 (GST shall be paid Extra)
Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. DSR 13.47.1 (GST shall be paid Extra)
Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. DSR 5.22.6 (GST shall be paid Extra)
Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works) DSR 13.48.3 (GST shall be paid Extra)
Drain Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil AS PER DSR 2.6.1
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) AS PER DSR 4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) AS PER DSR 4.1.3
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) AS PER DSR 13.4.2
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) AS PER DSR 6.4.1
INTERLOCKING TILES ROAD Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil ( loan clay orsand) including lift upto 1.5 m and leadup to 30m.&including filling watering& ramming of excavated earth in to trenches or in to the space between the building & the sides of foundation trenches or in to the plinth and removal & disposal of surplus excavated earth as directed by the Engineer i/c upto a distance of 30 m from the foundation trenches. DSR-2.6.1 (GST shall be paid Extra)
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. DSR 16.78.1 (GST shall be paid Extra)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:1:6 (1 cement : 6 sand) DSR -6.1.2 (GST shall be paid Extra)
Providing and laying 80mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. MR (GST shall be paid Extra)
[HORTICULTURE WORKS] Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR 2.31 (GST shall be paid Extra)
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).DSR 2.1 (GST shall be paid Extra)
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). DSR 2.2 (GST shall be paid Extra)
Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm. (DSR-2.4.3) (GST shall be paid Extra)
Carrigae of manure upto 5 K.M. (DSR-1.1.3) (GST shall be paid Extra)
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. (DSR-2.9) (GST shall be paid Extra)
Edging with bricks laid dry length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within a lead of 50 m : Common burnt clay F.P.S (non modular) bricks of Class designation 7.5 DSR 2.19 (GST shall be paid Extra)
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately DSR 2.14.2 (GST shall be paid Extra)
Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.DSR 7.60 (GST shall be paid Extra)
Providing and stacking of Saraca indica (Sita Ashok) of height 105-120 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR 7.80 (GST shall be paid Extra)
Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. DSR 7.64 (GST shall be paid Extra)
Providing and stacking of Schleichera trijuga (Kusum) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge DSR 7.81 (GST shall be paid Extra)
Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. DSR 7.44 (GST shall be paid Extra)
Making tree guard 53 cm dia and 2 m high as per design from empty coal tar drums, supplied free by the department, including providing and fixing four legs 40 cm long of 30 x 3 mm M.S. flat riveted to tree guard and providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed with rivets complete in all respects including painting inside and outside of tree guard with DSR 2.18 (GST shall be paid Extra)
CONSTRUCTION OF TUBE WELL AND INSTALLATION OF SUBMERSIBLE PUMP Installation of Rig machine with all T&P ,camp,equipage water tank etc. at site (GST shall be paid Extra)
Drilling of 350 to 450 mm dia bore for construction of borewell by rig machine (GST shall be paid Extra)
Lowering of 8" housing pipe threaded (GST shall be paid Extra)
Lowering of 6" BP threaded (GST shall be paid Extra)
Lowering of 8" slotted pipe threaded (GST shall be paid Extra)
S/F 8" dia MS socket (GST shall be paid Extra)
S/F 6" dia MS socket (GST shall be paid Extra)
S/F 8"/6% dia MS Ruducer (GST shall be paid Extra)
S/F 8" dia MS Well cap (GST shall be paid Extra)
S/F 8" dia MS ball plug (GST shall be paid Extra)
Strata sample box (GST shall be paid Extra)
Cost of Pee gravel (GST shall be paid Extra)
Development of tubewell by air compressor (GST shall be paid Extra)
Development of tubewell by O.P. unit (GST shall be paid Extra)
S/F 7.5 H.P. Submersible Pump with control pannel, cable, columnpipe and all accessories complete. (GST shall be paid Extra)
Carted earth Earth work in filling plinth with cartage earth DSR 2.25a (GST shall be paid Extra)
Elecrtification of Main Admin Building Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. DSR 1.10.3 (GST Shall be paid extra)
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. DSR 1.11 (GST Shall be paid extra)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1x1.5 sqmm.for Inverter D.S.R 1.17.1 (GST Shall be paid extra)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. DSR 1.31 (GST Shall be paid extra)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. DSR 1.32 (GST Shall be paid extra)
S/F suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" Curve including connections, painting etc. as required. DSR 1.57 (GST Shall be paid extra)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR 1.14.2 (GST Shall be paid extra)
2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR 1.14.3 (GST Shall be paid extra)
2 X 6 sq. mm + 1 X 6 sq. mm earth wire DSR 1.14.4 (GST Shall be paid extra)
2 X 10 sq. mm + 1 X 10 sq. mm earth wire DSR 1.14.5 (GST Shall be paid extra)
2 X 16 sq. mm + 1 X 16 sq. mm earth wire DSR 1.14.6 (GST Shall be paid extra)
4 X 16 sq. mm + 2 X 16 sq. mm earth wire DSR 1.14.11 (GST Shall be paid extra)
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. DSR 1.38 (GST Shall be paid extra)
S&F of 200 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge. MR (GST Shall be paid extra)
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. DSR 2.21 (GST Shall be paid extra)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way, Double door DSR 2.3.2 (GST Shall be paid extra)
(b) 12 way, Double door DSR 2.3.3 (GST Shall be paid extra)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door DSR 2.4.1 (GST Shall be paid extra)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door DSR 2.5.1 (GST Shall be paid extra)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole DSR 2.10.1 (GST Shall be paid extra)
(b) Double pole DSR 2.10.3 (GST Shall be paid extra)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. DSR 2.11 (GST Shall be paid extra)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 40 amps DSR 2.12.1 (GST Shall be paid extra)
(b) 63 amps DSR 2.12.2 (GST Shall be paid extra)
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB DSR 2.2.1 (GST Shall be paid extra)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 9a) 40 amps DSR 2.13.1 (GST Shall be paid extra)
(b) 63 amps DSR 2.13.2 (GST Shall be paid extra)
Design manufacturing, Supply Installation testing and commissioning of 1000A LT Panel. The Panel shall be fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with Powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus bar of Panel shall be of High grade Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The calculation of continuous rating of Bus Bar shall be submitted. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure bear the jerks of short Circuit as fault level require. The Fault level of Panel shall be 35kA for 1sec. All Indicating Lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The Panel shall be completed in all respect and shall consist of following material. Incomer: 1000A FP ACB– 1 Set, Outgoing : 200A FP-2 Nos MCCB. 100A FP- 5 Nos. MCCB and 63A FP-2 Nos. MCCB MR (GST Shall be paid extra)
Design manufacturing, Supply Installation testing and commissioning of 200A LT Panel. The Panel shall be fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with Powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus bar of Panel shall be of High grade Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The calculation of continuous rating of Bus Bar shall be submitted. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure bear the jerks of short Circuit as fault level require. The Fault level of Panel shall be 35kA for 1sec. All Indicating Lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The Panel shall be completed in all respect and shall consist of following material. Incomer: 200A FP, MCCB – 1 Set Outgoing : 100A FP, MCCB – 1 Set and 63A FP, MCCB – 3 Set MR (GST Shall be paid extra)
Design manufacturing, Supply Installation testing and commissioning of 100A LT Panel. The Panel shall be fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with Powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus bar of Panel shall be of High grade Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The calculation of continuous rating of Bus Bar shall be submitted. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure bear the jerks of short Circuit as fault level require. The Fault level of Panel shall be 35kA for 1sec. All Indicating Lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The Panel shall be completed in all respect and shall consist of following material. Incomer: 100A FP,MCCB – 1 Set Outgoing : 63A FP, MCCB – 2 Set MR (GST Shall be paid extra)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR 5.6 (GST Shall be paid extra)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. DSR 5.14 (GST Shall be paid extra)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15 (GST Shall be paid extra)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. DSR 5.16 (GST Shall be paid extra)
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing DSR Civil 10.18 (GST Shall be paid extra)
Supplying, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor notless than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. D.S.R 19.1 (GST Shall be paid extra)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep DSR 1.50.1 (GST Shall be paid extra)
Supply of Fresh air Fan 300 mm 1-phase 1400 rpm, 230/250 Volts, 50 Hz MR (GST Shall be paid extra)
Supply of Exhaust Fan 450 mm 1-phase 1400 rpm, 230/250 Volts, 50 Hz MR (GST Shall be paid extra)
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. complete in all respect. including Lugs and Glands (a) 16 sq. mm 3-1/2 core RA (GST Shall be paid extra)
(b) 25 sq. mm 3-1/2 core RA (GST Shall be paid extra)
© 50 sq. mm 3-1/2 core RA (GST Shall be paid extra)
(d) 70 sq. mm 3-1/2 core RA (GST Shall be paid extra)
(e) 400 sq. mm 3-1/2 core RA (GST Shall be paid extra)
Supply and Fixing of LED Tube Light Batten suitable for upto 1X20 watt LED Tube Light on Surface 100 lm/watt, P.F.>0.95, THD<10% at full Load, CRI>80, Sheet Thickness 0.8 mm complete in all respect. RA (GST Shall be paid extra)
Supply and Fixing of Single Light Wall Bracket with opal glasspaint finishing upto 6 Watt LED complete in all respect. RA (GST Shall be paid extra)
Supply and Fixing of LED Bulb 9 Watt lumen 810 to 945 complete in all respect. (GST Shall be paid extra)
Supply and Fixing of LED Bulb 7 Watt lumen 630 to 735 complete in all respect. RA (GST Shall be paid extra)
Supply and Fixing of Bulkhead fitting upto 10 Watt lumen 1000 complete in all respect. RA (GST Shall be paid extra)
Supply and fixing of 2'x2' 36Watt to 46 Watt, Indoor Recess/Surface mounting LED Square Fitting for Armstrong Ceiling Powder quoted CRCA housing body diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT AAA RA (GST Shall be paid extra)
Supply and Fixing of LED Street Light fitting having die cast aluminium body and diffuser with driver set suitable for 90 Watt confirming to IP 66 and above protection complete in all respect. 82500-9900 system lumens high power LED with lenses> 110 lm/watt, P.F.>0.95, THD<10% at full Load, CRI>70, potted driver set phase to phase protection at 440 V and >300 V, auto cut and restart feature with 5 Year warranty. RA (GST Shall be paid extra)
Supply and Installation of split type A.C 5 Star invertor Type Mistubishi (GR Series)/O-General (CETA B Series)/Toshiba (G3KCV Series) 2.0 Ton Capacity MR (GST Shall be paid extra)
As above for 1.5 Ton Capacity MR (GST Shall be paid extra)
5 KVA Voltage Stablizer for Air Conditioner Upto 2TR (130 - 300 Range) Copper Winding. MR (GST Shall be paid extra)
4 KVA Voltage Stablizer for Air Conditioner Upto 1.5TR (130 - 300 Range) Copper Winding.MR (GST Shall be paid extra)
Supply of Out Door Unit stand for split type A.C MR (GST Shall be paid extra)
SITC of suction/Discharge Copper pipe line in split A.C unit 1.5 ton capacity including brazing, nitrile rubber insulation 9mm thick class o etc comlete 1/4" (6.40mm) and 1/2" (12.70) MR (GST Shall be paid extra)
SITC of suction/Discharge Copper pipe line in split A.C unit 1.8/2.0 ton capacity including brazing, nitrile rubber insulation 9mm thick class o etc comlete 3/8" (9.50mm) and 5/8" (15.90) MR (GST Shall be paid extra)
S/I of heavy duty CPVC 20mm/25mm OD pipe for condensed water drain with clipping accessories complete. MR (GST Shall be paid extra)
S & F of Door Closer MR (GST Shall be paid extra)
2.5sqmm 3 core Round cable for A.c Connecting indoor to unit to Stablizer/power point. MR (GST Shall be paid extra)
2.5sqmm 4 core Round cable for A.c Connecting indoor/Outdoor MR (GST Shall be paid extra)
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. MR (GST Shall be paid extra)
Same as item No.55 for Double arm Bracket MR (GST Shall be paid extra)
Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. MR (GST Shall be paid extra)
Fire Fighting System Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (a) 200 mm Dia DSR 18.7.9 (GST Shall be paid extra)
(b) 150 mm Dia DSR 18.7.8 (GST Shall be paid extra)
© 100 mm Dia DSR 18.7.7 (GST Shall be paid extra)
(d) 80 mm Dia DSR 18.7.6 (GST Shall be paid extra)
(e) 25 mm Dia DSR 18.7.1 (GST Shall be paid extra)
Providing, Fixing,Testing & commissioning of 15 mm Dia quartzoid bulb type Sprinklers of rating 68 degree centigrade with required accessories. (a) Pendant sprinkler / sprinkler DSR 18.21.1 (GST Shall be paid extra)
Supplying, fixing, testing & commission of butterfly valve of PN-16 slim seal standerd lever operated type as per design standerd IS:1395 or BS:5155 with required flanges, nut bolts etc. complete in all respects. (a) 200 mm dia DSR 18.11.7 (GST Shall be paid extra)
(b) 100 mm dia DSR 18.11.5 (GST Shall be paid extra)
© 80 mm dia DSR 18.11.4 (GST Shall be paid extra)
Providing, installation, testing and commission of non-return valve of following sizes PN-10 as per design standerd IS: 5312 or BS:1868 with companion flanges, bolts, nuts, washers etc. complete in all respects. (a) 150 mm dia DSR 18.14.7 (GST Shall be paid extra)
(b) 100 mm dia DSR 18.14.5 (GST Shall be paid extra)
© 80 mm dia DSR 18.14.4 (GST Shall be paid extra)
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked completewith nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : (a) 150 mm dia DSR 18.12.6 (GST Shall be paid extra)
(b) 100 mm dia DSR 18.12.5 (GST Shall be paid extra)
© 80 mm dia DSR 18.12.4 (GST Shall be paid extra)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. (a) 30 m DSR 18.17.1 (GST Shall be paid extra)
Supplying Installation testing & Commissioning of 25 mm Air Release valve gunmental having rubber ball and with 25 mm BSP threaded male inlet including necessary accessories and connections complete in all respect. MR (GST Shall be paid extra)
Supplying Installation testing & Commissioning of SS/GM/Ball Valve 50 mm dia complete. MR (GST Shall be paid extra)
SITC of Hose Box of 18 SWG MS Sheet with glass fronted door to accommodate 2 nos. RRL hose & 1 no. SS Branch Pipe with nozzle (External/ Internal) Size 800x600x400 MR (GST Shall be paid extra)
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63mm dia male and female couplings duly bound with Gl wire, rivets etc. conforming to IS 636 (type-A) as required : (a) Stainless Steel DSR 18.16.2 (GST Shall be paid extra)
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: (a) Stainless Steel (Grade 304) DSR 18.18.2 (GST Shall be paid extra)
(A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) 450 Ipm at 35 m Head DSR 18.4.2 (GST Shall be paid extra)
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. DSR 18.2 (GST Shall be paid extra)
Supply Installation testing and commissioning of Pressure Gauge. MR (GST Shall be paid extra)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : (a) 4 way - 150 mm dia M.S. Pipe DSR 18.19.2 (GST Shall be paid extra)
SITC of Automatic panel of tarrace pump suitable for 5 HP tarrace pump. MR (GST Shall be paid extra)
Supplying Laying testing & Commissioning of 2 corex 1.5 sq.mm single standard copper conductor, PVC insulated armored cable. DSR 17.5.2 (GST Shall be paid extra)
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. complete in all respect. including Lugs and Glands (a) 185 sqmm 3-1/2 core RA (GST Shall be paid extra)
(b) 95 sqmm 3-1/2 core RA (GST Shall be paid extra)
© 16 sqmm 4 core RA (GST Shall be paid extra)
S/F of 200 AMP 4 pole changeover switch with angle iron frame complete. MR (GST Shall be paid extra)
S/L of 1800mmX900mmX12mm thick chequered rubber matting of tested quality MR (GST Shall be paid extra)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR 5.6 (GST Shall be paid extra)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.DSR 5.14 (GST Shall be paid extra)
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. DSR 18.22 (GST Shall be paid extra)
Supplying and fixing single headed hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel DSR 18.9.2 (GST Shall be paid extra)
Supply, Installation, Testing & Commissioning of Electric Driven Main Fire Pump Suitable for auto operation & consisting of following: complete in all resp ect as required. Single headed Stainless steel (a) Horizontal split Casing type, centrifugal, multistage, pump of cast iron body & bronze impeller with stainless steel shaft Mechanical seal at specified flow of 1620 lpm at 70 Meter head confirming to IS 1520. (b) Suitable HP squirrel cage induction motor,TEFC synchronous speed 1500 RPM 60 HP (with permissible slip) suitable for operation on 415 volts, 3 phase 50Hz.AC with IP 55 protectiion for enclosure, horizontal foot mounted type with class- "F" insulation, conferming to IS-325 (c) Common base frame fabricated out of M.S channel of suitable size flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc. (c) Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. DSR 18.1.8 (GST Shall be paid extra)
Supply, Installation, Testing & Commissioning of Diesel Engine Driven main fire pump suitable for auto operation & consisting of following: complete in all respect as required. (a) Horizontal split Casing type,centrifugal, multistage, pump of cast iron body & bronze impeller with stainless steel shaft, Mechanical seal at specified flow of 1620 lpm at 70 meter head confirming to IS 1520.(b)Suitable HP 1500 RPM, 4 stroke, cold starting type Diesel Engine with Heat Exchanger confirming to relevant BIS & IS Standards, complete with all required accessories/system, fuel oil filter ,lubricant oil pump with filter, 1 set Starting batteries of 180AH capicity each with suitable angle iron stand,engine starting panel havng all the controls meters, gauges, (c)techo meter,hour meter, starting switch with keys for manual starting, auto starting mechanism, 12/24 volt electric starting equipment, Deisel tank for 8 hrs continuous running for Diesel Engine having minimum capicity of 200 Ltrs. (Tank made out of 3mm thick M.S.Sheet with filling cap, drain cock, diesel indicator duly mounted on M.S.angle) exhaust pipe of minimum 10 mtr. length, duly insulated with 50 mm thick glass wool with 1.0 mm.thick alluminium sheet cladding, exuast reidential silencer,stop solenold for auto stop in the event of fault with audio indications, painting etc. as required. (d) M.S fabricated Common base frame,flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc. (e) Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications. DSR 18.2.9 (GST Shall be paid extra)
Supplying, fixing, testing & commission of Electric Driven Pressurisation Pump (Jockey Pump) suitable for auto operation consisting of following complete in all respect as required. (a) Horizontal type, centrifugal & suction type, pump of cast iron body & bronze impeller with stainless steel shaft Mechanical seal, gland packing & flow of 180 lpm at 70 Mtr. Head confirming to IS:-1520. (b) Common base frame fabricated out of M.S channel of suitable able size flexible coupling, coupling guard, foundation bolt & pressure gauge with valve etc. (c) Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per detailed specifications.DSR 18.3.2 (GST Shall be paid extra)
SITC Automatic priming arrangement for all fire pumps including necessary pipe, fitting, water level controller, 1 HP pump, auto starter gate valve NRV's etc complete. MR (GST Shall be paid extra)
(b) Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. DSR 17.2.4 (GST Shall be paid extra)
Supplying, installation, testing & commissioning of intelligent addressable thermal (heat) detector with rate of rise cum fixed tempreature thermistor complete with base as required. DSR 17.2.9 (GST Shall be paid extra)
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. DSR 17.2.5 (GST Shall be paid extra)
Supplying Installation testing & Commissioning of Addressable Manual Call Point complete with base as required. DSR 17.2.14 (GST Shall be paid extra)
Supplying Installation testing & Commissioning of Addressable horn cum strobe complete with base as required. DSR 17.2.15 (GST Shall be paid extra)
Supplying Installation testing & Commissioning of fault isolator complete with base as required. DSR 17.2.7 (GST Shall be paid extra)
Supplying Laying testing & Commissioning of 2 corex 1.5 sq.mm single standard copper conductor, PVC insulated armored cable. DSR 17.5.2 (GST Shall be paid extra)
Supply & fixing of CO2 type fire extinguisher, 4.5 kg. capacity (ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. MR (GST Shall be paid extra)
Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. MR (GST Shall be paid extra)
SITC of (i) one pump house having size 5.0 mtr.x4.5mtr.x3.0mtr.approx (ii) Underground RCC water tank having 1.0 Lacs ltr. Capacity approx.(iii) Tarrace PVC tank having capacity 10000 ltr.-2 no.(vi) Tubewell complete in all respect with boring 5 HP submarsible pump control pannel including fitting testing etc.(L/S) MR (GST Shall be paid extra)
Providing and Fixing Self glow Exit signage for stairs and exits. Size 100 x 300 MR (GST Shall be paid extra)
Supply, installation, commissioning and testing of 15 passengers capacity elevators machine room, etc., complete. Type of Elevator: Passenger Elevators Capacity of the Elevator 1020 kgs (15 passengers) Speed: 1.00m/s Number of floors to be served: Stilt +First+ Second+Third + Fourth Floor Number of landing entrances: 5 Number of Landing: 5 Travel distance: 18.00 m Size of Lift well available: 2000 mm x 2800mm Min. Lift pit depth available: 1600 mm Lift car inside: 1000mm x 2400mmx 2200mm lift car door finish: Stainless Steel Hairline finish Lift car finish for walls: Stainless Steel Hairline finish Type of car door: Automatic center opening Stainless steel hairline finish type of landing door: Automatic center opening Stainless steel hairline finish Lift car ceiling & lighting: SS- Moonlight Automatic Rescue Device MR (GST Shall be paid extra)
H. T. SYSTEM 630KVA 11/0.433KV CSS Supply, receiving, storing, inspection, handling, assembling, installation in correct aligned position,effecting proper connections, testing and commissioning of Outdoor type package type substation with continuous rating DYn11 Copper Wounded VCC-Cast Resin Dry Type Transformer with Off load tap links of +5% to -5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits of 115 deg.C. Impedance of 5%(Subject to IS Tol.) with WTI scanner. MAKES- ABB/SIEMENS/GE HT SWITCHGEAR CVC Type 11kV 630Amps 21KA/3 sec. Non-Extensible Compact Switchgear having Fixed Manual Vacuum Circuit Breaker as Outgoing in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. 1 nos ( Make - Shall be same as make of CSS) Relay shall be of 4 element 3O/C & 1 E/F The tripping current can be set to 20% -200% in steps of 1% for phase and 10% - 80% in steps of 1% for earth fault with associated protection class CTs suitable for transformer rating as per manufacturer's recommendation. 1 nos Protection CT shall be 80/1A 2.5VA 10P10 1 sets Manometer x 1 nos Metering Module arrangement containing metering class CTs (Acc.Cl.1.0) of suitable ratio, metering class PTs (Acc.Cl.1.0) of suitable ratio and Multifunction Meter (Acc.Cl.1.0) for measurement of various parameters such as kV, kVA, kW, kWh, pF, Hz etc of the Transformer feeder only. x 1 set Interconnection between HT Switchgear/Metering-Box and primary of transformer shall be done through 1C x 3 x 95 sq.mm Al. Unarmoured XLPE cable 1 set TRANSFORMER 630KVA 11KV/433V DYn11 Copper Wounded Cast Resin Dry Type Transformer with Off load tap links of +5% to -5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits of 115 deg.C. Impedance of 5%(Subject to IS Tol.) with WTI scanner.(Make- Same as Make of CSS) x 1 nos LOSSES AS PER IS TOLERANCES INCOMER FROM TRANSFORMER 1250Amps 433V 50KA 4P Fixed manual type (MF) ACB with microprocessor release for over current ,short circuit and earth fault protection and under voltage release with Ics = Icu = Icw for 1 sec). The release should be compatible with bluetooth Make : ABB (Emax) /Siemens(3WL)/ Schneider(Masterpact NW 6E) R,Y,B,ON/OFF/TRIP Indications. X 1 set Multifunction meter of class 1 accuracy and RS 485 port x 1 nos OUTDOOR ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel with combination of 1.5/2mm thickness with 4mm HRCA base frame.The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure shall be powder coated (Colour Light Gray & D.A.Gray). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. x 1 set INTERCONNECTION AND EARTHING Interconnection Between HT switchgear & Transformer using 3C x 2R x 240 Sq.mm XLPE Single core Copper cable & Interconnection between Transformer & LT switchgear using Copper Busbars. Internal earthing connections including transformer neutral by using 50 x 6mm GI strips. DSR PAR-2023/ 6.2.1 (GST Shall be paid extra)
D.G. SET-1 Nos. 125KVA-D.G. SET, Supply, installation, testing & commissioning of 3-phase, 415 volt, 1500 RPM, 50 HZ, Diesel generator set with prime rating capacity of 125 KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure,battery, batter charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator,WITH AUTOMATIC MAINS FAILURE CONTROL PANEL SYSTEM , safties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to IS:4722. generator makes- STERLING/KIRLOSKAR/CUMMINS/CATERPILLAR alternator makes - CROMPTON/ KIRLOSKAR/LEROY SOMER MR (GST Shall be paid extra)
SITC of ups 20 KVA 3 phase for backup upto 30 minutes complete having High Frequency and Double Conversion Online Technology.High End IGBT Based.High End Micro Controller Based.Wide Input Voltage Range Advanced PFC Technology Advanced Battery Management Automatic Battery Charging in UPS Off Mode Short Circuit and Overload Protection Smart RS232 Communication with monitoring software Over Temperature Protection. EMI / RFI Noise Filter LCD/LED Display simultaneously Specially designed to suit Indian Power and Environment Conditions Generator Compatible (Supplying Sinewave Voltage) Different Output Voltage settings.Output Frequency fixed at 50Hz or can be synchronized with Input Frequency. Static Bypass Enable or Disable. Outlets Programmable and Non-Programmable. Protection from DC Fan failure.In-built Over Voltage Cut-Off Device.Isolation Transformer (Optional) SNMP Card Slot (Optional). MR (GST Shall be paid extra)
Supply of 3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3.5 X 240 sq. mm MR (GST Shall be paid extra)
Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served shethed, underground cable including rubber ring etc. complete in all respect.The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge.3.5 X 240 sq. mm MR (GST Shall be paid extra)
Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-incharge. 240 sq. mm MR (GST Shall be paid extra)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. DSR 5.6 (GST Shall be paid extra)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. DSR 5.14 (GST Shall be paid extra)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. DSR 5.15 (GST Shall be paid extra)
SITC of Grid Interactive roof top photo voltaic power generation system including space frame MR (GST Shall be paid extra)
SITC of 4 MP Day & Night Dome Network Camera with IR Make:- Honeywell/ Bosch/ Axis MR (GST Shall be paid extra)
SITC of 4 MP Day & Night Bullet Network Camera with IR Make:- Honeywell/ Bosch/ Axis MR (GST Shall be paid extra)
SITC of 16CH 4k 4SATA NVR for 30 Days Recording Make:- Honeywell/ Bosch/ Axis MR (GST Shall be paid extra)
SITC of WD Hard Disk 8TB Survillance Make:- WD/ Seagate/ Toshiba MR (GST Shall be paid extra)
SITC of LG / Samsung 55” smart TV 4K contrast ratio 4000:1, brightness 350 nits, resolution 3840x2160(16:9) Make Samsung/LG. MR (GST Shall be paid extra)
SITC of 28-Port 10-Gigabit Smart Managed Switch, 24 x 10/100/1000BASE-T ports, 4 x 10G SFP+ ports for choosing the most suitable media type for your requirement, Lite L3 Static Routing for increased network efficiency. Make:-D-Link/ CISCO/ Juniper MR (GST Shall be paid extra)
SITC of 28-Port 10-Gigabit Managed PoE Switch, 24 x 10/100/1000BASE-T PoE ports,4 x 10G SFP+ ports for choosing the most suitable media type for your requirement, 370W PoE Power Budget (802.3af/at) to allow more power for connected device, Make:-D-Link/ CISCO/ Juniper MR (GST Shall be paid extra)
SITC of Camera Back Box PVC Type MR (GST Shall be paid extra)
SITC of UTP Cat-6 Cable 4 Pair 23 AWG LSZH Make:-D-Link/ Commscope/Molex MR (GST Shall be paid extra)
SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port- Fully Loaded MR (GST Shall be paid extra)
SITC of CAT6 UTP PATCH CORD LSZH:1M MR (GST Shall be paid extra)
SITC of CAT6 UTP PATCH CORD LSZH:2M MR (GST Shall be paid extra)
SITC of Cat-6, 4 Pair, Moduler Jack without dust cover, Blue with 1 Port Faceplate and Back Box MR (GST Shall be paid extra)
SITC of RJ - 45 Connector (100 Nos - 1 Box) MR (GST Shall be paid extra)
SITC of Wall Mount 15U x 600 W x 600 D , Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking Welded Side Walls With Metal Engraved Logo S t a n d a r d A c c e s s o r i e s : 1U PVC Cable Manager (1), Hardware Packet (1 Pkt) 6 Socket 5 Amp. Power Distribution Unit (1 No) Roof Mounted Fan Unit / 90 CFM /230V AC (1 No) MR (GST Shall be paid extra)
SITC of Wall Mount 12U x 600 W x 600 D , Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking Welded Side Walls With Metal Engraved Logo S t a n d a r d A c c e s s o r i e s : 1U PVC Cable Manager (1), Hardware Packet (1 Pkt) 6 Socket 5 Amp. Power Distribution Unit (1 No) Roof Mounted Fan Unit / 90 CFM /230V AC (1 No) MR (GST Shall be paid extra)
SITC of PVC Conduit 25 mm Medium MR (GST Shall be paid extra)
SITC of PVC Conduit 32 mm Medium MR (GST Shall be paid extra)
Performance Testing Penta Scanning of Cat-6 Cable MR (GST Shall be paid extra)
Supply of Bosch Chairman unit with built in flexible gooseneck mike length 318 mm , press to talk button, priority switch, 2 headphone sockets with rotary volume control and microphone with light ring LED , Loudspeaker volume is set centrally at the Control Unit for all delegate units. To prevent acoustic feedback, the built-in loudspeaker is automatically muted when the microphone is on.. Unit has 1 x 2.7 m (106.3 in) cable terminated with a 8-pin male connector for loop-through connection to other. • 1 x 8-pin circular female connector for loop-through connection to other delegate or chairman units. • 2 x 3.5 mm (0.14 in) stereo headphone sockets. MR (GST Shall be paid extra)
Supply of Bosch CCS 700 Delegate unit with built in flexible gooseneck cardiode mike length 318 mm , press to talk button, built in speaker ,Microphone ON / OFF or request to speak button , 2 headphone sockets with volume control complete as above but with out priority . MR (GST Shall be paid extra)
Bosch 240 watt mixing amplifier having multiple outputs 70 /100 Volts and 8/4 Ohms, .Temperature controlled forced front to back ventilation directly stackable , mains / battery backup , 2U 19” case , input voltage 230 Volts AC Frequency 50 to 18000 Hz, S/N Ratio > 75dB .Impedance 1 K balanced. Unit has 4 balanced inputs / 3 stereo line inputs with separate bass & treble control MR (GST Shall be paid extra)
SITC OF 85/ 86” panel of LG /Samsung make signage panel having Screen Size 86 Inch Higher LED Back Lit Smart TV, Panel Technology IPS, Native Resolution 3840x2160 (UHD)4K, Brightness 330 cd/m2, Contrast Ratio 1100:01:00, Operating System WebOS, Orientation Landscape, Viewing Angle(HxV) 178 x 178, Connectivity - Input ports, Digital HDMI -3, RF -1, External Control RS232C -1, RJ45 -1, USB USB -1, Output Ports, Built Wifi, HDR HDR10/HDR+/HDR Pro, Wire Less Bluetooth, WI-FI, Smart Share /Miracast, Audio Power 20W(10W x 2), Power Supply 100 – 240 V, 50/60 Hz, Wall mount Required, Accessories Remote control.Make Samsung/LG. MR (GST Shall be paid extra)
SITC of ATDSC make USB based PTZ Camera Yes; Zoom: Minimum 20X Optical Zoom; Iris: f=5.5~110mm; AV: F1.6 ~ F3.5; Viewing Angle:3.3° (tele) –54.7° Wide; Sensor:1 /2.8inch or better CMOS sensor; Pixels:2.07 Mega Pixel ; Video Format: SDI Video Formats: 1080P60/50/30/25/59.94/29.97 ; 1080I60/50/59.94. 720P / 50/ 30 /25 /59.94/29.97; Minimum illiumination:0.5 Lux ; DNR:2D & 3D DNR; White Balance :Auto/Manual/One push 3000K / 3500K / 4000K / 4500K / 5000K / 5500K / 6000K / 6500K /7000K; Electronic Shutter : Auto/Manual; Focus : Should be Auto/Manual/One Push; BLC:ON/Off; WDR : Off/Dynamic level adjustment; Video Adjustment: Brightness, Color, Saturation, Contrast, Sharpness, B/W mode, Gamma curve; SNR :>55 dB; Interface:: USB 2.0, LAN, RS232; Video Compression Format:H.265/H.264 ; Control Protocol: VISCA/PELCO-D/Pelco-P; Baud Rate : 11520 / 9600 / 4800 / 2400 ; LAN Port :Yes; Network Protocol: RTSP/RTMP/ ONVIF, GB/T28181; Pan Rotation:+ 170° Tilt Rotation :- 30°~+90° ; Pan Control Speed: 0.1~60°/second ;Tilt Control Speed : 0.1~30°/second ;Preset Speed: Pan: 60°/second, Tilt 30°/second ;PresetNumber:255 preset MR (GST Shall be paid extra)
SITC of Switch cum scaler 4K having 2 HDMI, 1 VGA &1 unbalanced stereo audio inputs & RS232 port Out puts are 1 HDMI & 1 unbalanced stereo audio make : Kramer / Aten. MR (GST Shall be paid extra)
SITC of 1 in 4 out HDMI distribution amplifier make : Kramer / Aten MR (GST Shall be paid extra)
Kramer / Aten make wireless presentation system MR (GST Shall be paid extra)
SITC of HDMI cable & Connectors MR (GST Shall be paid extra)
SITC of Professional PA rack to mount amplifiers, CCU and other control items with front acrylic cover , fan colled and with wheels. Custom built (GST Shall be paid extra)
Kramer / Aten pop up box complete with 15 pin HD, 1 HDMI, 1 Ethernet & 1 USB for wired presentation MR (GST Shall be paid extra)
LS cable & Connectors MR (GST Shall be paid extra)
8 core conference cable 10 Meters MR (GST Shall be paid extra)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid