Tender Value
₹90.9 L
EMD Value
₹90,884
Closing Date
30 May 2023, 11:00 amClosed
SITC of Installation of New VRV (Variable refrigerant volume) and fixing of electric panels for the office of Director, special Director, Addl. Director, JD Club, conference hall
NSL/CEO/CBI/NIT/2023/565
NSL/CEO/CBI/NIT/2023/565
Open Tender-Domestic
Electrical Work
New Delhi, Delhi
₹2,950
₹90,884
18 Jul 2023
2 May 2023
30 May 2023
30 May 2023
7 Jun 2023
S.No Description of Item DSR amount NDSR amount
Multiple factor @ 1.06 for DSR
3 Total amount (S.No 1+2) 9088314.00
3 Total amount (S.No 1+2) 9088314.00
Digitally signed by AMIT
BOQ for Supply Installation testing & Installation of New VRV (variable refrigenrant volume) inclusing allied electrical work for the Director Office ,
JDA office, JD Club & Conference hall at 11th floor, CBI HQ Building, New Delhi
S.No. Particulars Qty Unit Rate Amount DSR Amount NSR
DSR 2019 OUTDOOR UNITS
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant
Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and
heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum
two compressors for above 14 HP modules, microprocessor based Controller, top
discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with
1 1 suitable foundation etc.complete as required. The unit shall deliver the rated 156.00 HP 16415.00 2560740.00
capacity at AHRI Conditions and work even at 50°C ambient temperature without
tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC
power supply. The unit shall be filled with first charge of the refrigerant and ready
for use as required. The COP at AHRI conditions shall not be less than 3.1 and
IEER not less than 6.5 .
DSR 2019 INDOOR UNITS
Supply, installation, testing and commissioning of following minimum capacity 4-
way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with
synthetic washable media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX Copper coil, electronic
expansion valve,outer cabinet, drain pump, grill, necessary supports, vibration
isolation, cord less remote control etc., suitable for operation on single phase 230 V
± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force
shut down provision in case of fire on receiving signal from BMS System. The
cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and
WB temperature.
Supply, Installation, testing and commissioning including vaccumiazation and
Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant
piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type
3 DSR 2019 hanger supports, jointing/brazing including accessories, insulated with XPLE Class-
O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular
sleeves sections of specified thickness as given below for Suction and Liquid lines,
all accessories as per specifications etc. as required :
3.1 6.4 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 20.00 METER 245.00 4900.00
5.1 insulation Digitally signed by AMIT
BOQ for Supply Installation testing & Installation of New VRV (variable refrigenrant volume) inclusing allied electrical work for the Director Office ,
JDA office, JD Club & Conference hall at 11th floor, CBI HQ Building, New Delhi
S.No. Particulars Qty Unit Rate Amount DSR Amount NSR
3.2 9.5 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 154.40 METER 331.00 51106.40
5.2 insulation
3.3 12.7 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 5.00 METER 466.00 2330.00
5.3 insulation
3.4 15.86 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 119.40 METER 588.00 70207.20
5.4 insulation
3.5 19 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 220.00 METER 707.00 155540.00
5.5 insulation
3.6 22.2 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 60.00 METER 865.00 51900.00
5.6 insulation
3.7 25.4 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 64.70 METER 1022.00 66123.40
5.7 insulation
3.8 28.58 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 10.00 METER 1108.00 11080.00
5.8 insulation
3.9 31.8 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 64.70 METER 1170.00 75699.00
5.9 insulation
3.10 34.9 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 10.00 METER 1230.00 12300.00
5.1 insulation
3.11 38.1 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 30.00 METER 1265.00 37950.00
5.11 insulation
3.12 41.27 mm dia (OD) (Soft/Hard drawn) with tube thickness 1.2 mm with 19 mm thick 180.00 METER 1309.00 235620.00
5.12 insulation
4 MR Y JOINTS
4.1 1 Supply, Installation & Testing of Y joints for Indoor Units 73.00 Each 5723.00 417779.00
4.2 2 Supply, Installation & Testing of Y joints for outdoor Units 18.00 Each 15104.00 271872.00
5 MR DRAIN PIPING WORKS
Supply , Installation and testing of 40 mm Dia pipe with 6 mm nitrile rubber
insulation as per site conditions
Supply , Installation and testing of 32 mm Dia pipe with 6 mm nitrile rubber
insulation as per site conditions
Supply , Installation and testing of control & transmission wiring of VRV as per site
5 DSR CIVIL MS STAND WORKS
Steel work in built up tubular (round, square or rectangular hollow tubes
etc.) trusses etc., including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer, including welding and
bolted with special shaped washers etc. complete.
6 MR GAS CHARGING & LIFTING /SHIFTING WORKS WORKS Digitally signed by AMIT
BOQ for Supply Installation testing & Installation of New VRV (variable refrigenrant volume) inclusing allied electrical work for the Director Office ,
JDA office, JD Club & Conference hall at 11th floor, CBI HQ Building, New Delhi
S.No. Particulars Qty Unit Rate Amount DSR Amount NSR
Lifting & shifting of AC Outdoor from Ground Floor to terrace Complete in all
7 MR ELECTRICAL WORKS ( NS)
Supply OF allumnium armoured cable of 3.5C X 150 Sqmm Cable from Main
HVAC Panel to VRV Panel
9 Supply of 4C X 25 Sqmm Cu from VRV Panel to Outdoor Units 300.00 Meter 2913.81 874142.92
Provinding and fixing of outdoor electrical panel with Made up of 1.6 mm thick MS
powder Coated Sheet With Phase Indicators, Digital Ammeter, Voltmeters & having
250 A MCCB for incoming and 63 A FP RCCB-12 Nos. Outgoing for AC outdoor
DSR 2022 ELECTRICAL WORKS DSR 2022 E & M
Supplying and making end termination with brass compression gland and
11 9.1 aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE
aluminium conductor cable of 1.1 KV grade as required.
Laying and fixing of one no. PVC insulated and PV sheated/XLPE power cable of
7.7 1.1 KV grade of following size of wall surface as required
15 7.7.1 upto 35 sqmm (clamped with 1mm thick saddle ) 55 mtr 250 13750
16 7.7.3 above 95sqmm and upto 185 sqmm (clamped with 25/40x3mm ms flat clamp) 153 mtr 450 68850
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR
1.14 PVC insulated copper conductor, single core cable in surface/ recessed steel
17 conduit as required
19 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 334 mtr 750 250500
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop
5.19 earthing along with existing surface/ recessed conduit/ submain wiring/ cable as 127 mtr 650 82550
Supplying and installing following size of perforated painted with powder coating
M.S. cable trays with perforation not more than 17.5%, in convenient sections,
joined with connectors, suspended from the ceiling with M.S. suspenders including
21 bolts & nuts, painting suspenders etc as required.
22 4.1.1 100 mm width X 50 mm depth X 1.6 mm thickness 543 Mtr 50 27150
23 4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness 604 Mtr 150 90600
Digitally signed by AMIT
BOQ for Supply Installation testing & Installation of New VRV (variable refrigenrant volume) inclusing allied electrical work for the Director Office ,
JDA office, JD Club & Conference hall at 11th floor, CBI HQ Building, New Delhi
S.No. Particulars Qty Unit Rate Amount DSR Amount NSR
Supplying and fixing of following sizes of medium class PVC conduit along with
1.21 accessories in surface/recess including cutting the wall and making good the same
25 in case of recessed conduit as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size)
on surface or in recess with suitable size of phenolic laminated sheet cover in front
including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano
26 type switch, connections, painting etc. as required.
Digitally signed by AMIT
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT .pdf
Tender Document
Drawing.pdf
Tender Document
Forms.pdf
Tender Document
GCC upto amend3.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
LIST OF MAKES_CBI.pdf
Tender Document
SCC.pdf
Tender Document
BOQ.pdf
Tender Document
corrigendum-1653-Corrigendum IV for opening of financial bid.pdf
pdf • 0.48 MB
corrigendum-1612-Corrigendum-3.pdf
pdf • 0.74 MB
corrigendum-1594-Corrigendum-II.pdf
pdf • 0.20 MB
corrigendum-1583-Corrigendum-I.pdf
pdf • 0.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .