AGE (I) Naya Raipur
AGE (I) Naya Raipur C/o HQ COSA, Near International Cricket Stadium, Atal Nagar Raipur 492101
As per BOQ
2022_MES_526877_1
8400/328/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Naya Raipur
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) Naya Raipur
₹13,200
25 Jul 2022
27 May 2022
27 Jun 2022
27 May 2022
25 Jun 2022
11 Jun 2022
Amount
Supply only of calcium based granular chlorination chemical (chlorine contain 65-70%) with corrosion inhibitor & anti scaling agent to prevent distribution pipe line and safe for human consumption when used as water disfactant in 45 Kg factory sealed plastic containers. Note (i) Contractor should produce test certificate (from Central or State Government Lab) for % chlorine contain from any one drum of his supplied chlorination chemical for work order. (ii) Certificate from any DCGI approved lab for safe in human consumption to be produce by the contractor from the chemical manufacturer which is not earlier than one year (iii) The claim for corrosion inhibitor & anti scaling agent to prevent using or damage in distribution pipe line & accessories must be ratified by E-in-C's Br letter (copy of E-in-C's branch letter must be submitted to qualify for bid/tender) (iv) The quantity of materials should be taken from the contractor in phases.
Taking up or down steel tubing 25 to 40mm dia and connections, including cleaning for refixing or removal to store or for sch of credit complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing 50 to 100mm dia and connections, including cleaning for refixing or removal to store or for sch of credit complete all as specified and directed by Engr-in-Charge.
Taking down gate valve /ball valves any type complete all as specified and directed by Engr in charge.
M & L for GI tubing 25 mm dia medium grade galvanized with all fittings laid in trenches complete all as specified and directed. Make- TATA /JINDAL/SWASTIK/
M & L for GI tubing 40 mm dia medium grade galvanized with all fittings laid in trenches complete all as specified and directed. Make- TATA/ JINDAL/SWASTIK/
M & L for GI tubing 50 mm dia medium grade galvanized with all fittings laid in trenches complete all as specified and directed. Make- TATA/ JINDAL/SWASTIK/
M & L for GI tubing 80 m dia medium grade galvanized with all fittings laid in trenches complete all as specified and directed. Make- TATA/ JINDAL/SWASTIK
M & L for GI tubing 80 m dia heavy grade galvanized with all fittings laid in trenches complete all as specified and directed. Make- TATA/ JINDAL/SWASTIK
S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in 25mm bore dia
S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in 40mm bore dia complete all as specified
S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in 50mm bore dia complete all as specified
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches complete all as specified
Supplying and laying of 40mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches complete all as specified
Supplying and laying of 50mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches complete all as specified
Supplying and laying of 75mm inner dia CPVC pipes Schedule 80 pipes & plain CPVC Schedule 80 fittings on walls/ceiling or laying in floors/trenches complete all as specified
Supplying and laying of 100mm inner dia CPVC pipes Schedule 80 pipes & plain CPVC Schedule 80 fittings on walls/ceiling or laying in floors/trenches complete all as specified
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc,. and getting out complete all as specified and directed
Returning filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Taking up Ductile iron water mains 150 mm dia bore (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed.
All as per item No. 21 above here in above but 200 mm bore.
Material and labour for construction of valve pit chambers of size 600 X 600 X 600 mm (internal dimensions) as under provided with 10 cm thick PCC 1:4:8 type D-2 as in foundation over 15 cm thick hard core, 23 cm thick brick walls built in cement mortar 1:4, 15 mm thick internal plaster including top of floor, externally upto 150 mm below GL in CM 1:3 finished even and smooth without using extra cement, 3.00 mm thick MS sheet cover with 40 X 40 X 6 mm MS angle frame fixed in PCC 1:2:4 type B1, 50 mm thick coping with 25 X 6 mm flat iron hold fasts, hinges, handles, locking arrangements and applying 2 coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces and 3 coats of white wash to internal surfaces of chamber including excavation and earth work in any type of soil and removing of surplus soil to a distance not exceeding 50 m including dismantling of old valve pit complete all as specified and directed.
All as per item No 23 here in above but size 900 X 900 X 600 mm.
Material and labour 150 mm bore ductile iron pipes with spigot and socket ends centrifugally cast class LA, in any length laid in trenches complete all as specified and directed.
All as per item No. 25 above here in above but 200 mm bore.
Material and labour for repair of leakages in ductile iron pipes of any size(as above sizes) with all accessories as required on ground , all as per required and directed by engg In charge.
Supply and fixing CI body sluice valve class PN 1.6 with flanged ends of size 80mm bore having stainless steel spindle, CI gate with brass ring, operating wheel cast iron cape and connecting accessories etc complete all as specified and directed.
All as per item No. 29 above here in before but 100 mm bore.
All as per item No. 30 above here in before but 150 mm bore.
Rewinding of Motor 17.5 HP complete with supper enamelled heat resistant copper winding wire of same gauge nos of turn and weight of winding wire after cutting of worn out windings, preparing of winding slots, varnishing, heating and greasing etc including necessary lath work replacement of bambo strip, cotton taper, lather paper etc if required for rotar shaft and testing complete all as specified.
Rewinding of Motor 20 HP complete with supper enamelled heat resistant copper winding wire of same gauge nos of turn and weight of winding wire after cutting of worn out windings, preparing of winding slots, varnishing, heating and greasing etc including necessary lath work replacement of bambo strip, cotton taper, lather paper etc if required for rotar shaft and testing complete all as specified.
Lowering and re-fixing of submersible pump set at different places including pump set fitting commissioning and testing after replacement of defective parts with new one alongwith column pipe 50/80 mm bore with cable by suitable arrangement of chain pulley system and connection with starter electrically and connection with pipe line mechanically complete all as specified and detected. Note:- Defective parts if replaced shall be measured and paid under relevant item.
Flushing out/desilting of the bore well by using compressor hydro pressure jet for six hours air till clear the silt in the casing pipe by achiving clear water, and washing with hydro pressure jet using foam/oils, disinfecting the bore using sodium hypochloride solution and washing out till water is obtained to the required turbidity (clean water) to the entire satisfaction of Engr-In-Charge complete all as specified.
Supply and fix in repair for water level indicator of Over Head tank balancing indicator type , including fixing and repair of air aviation light over OH tank ,arrangements complete all as directed.
Supply and fix star - delta starter of current rating 40 amps with upto 25 HP phase failure, phase imbalance, phase reversal short circuit protection including voltmeter, ammeter with ON - OFF trip indication and dry run preventer complete all as specified. Make:- L&T/ C&S/ ABB.
Material and labour for repair to booster pump single / multistage, centrifugal/ monoblock electric driven including replacement of impeller, gasket, gun metal bush etc., to bring it in serviceable condition of capacity 3 HP to 5 HP complete all as specified. (Rate of material deemed to be included n rate quoted)
Cleaning and removing of all silt, dirt, mud, etc. from inside the over head tank reservoirs of capacity 50000 gallons staging, inside and out side of wall, mouth of inlet and outlet pipe, removing disposal of the same to a distance not exc. 50 m and applying one coat of white wash on internal surfaces including preparation of old and wet surfaces and sign, writing with white enamelled paint on black back ground, height of letters not less than 7.50cm on column showing capacity of tank and date of cleaning complete all as specified Note for item Nos. above :- (i) Cleaning shall be done by scrapper, removing dirt with wire brush and washing with bleaching powder. (ii) The inlet/ outlet/ overflow pipe of OH tank/ sump shall be cleaned properly and care should be taken to prevent entry/accumulation of sludge into pipe line by blocking mouth of pipe. Any blockage of the inlet/ outlet/ overflow pipe line shall be found to be cleared without any extra cost and the cost of the same shall be deemed to be included in the unit rate quoted. (iii) Writing the following words with white paint on black painted back ground to match with existing size and pattern :- (a) CLEANED ON:- ---- (b) NEXT DUE DATE OF CLEANING:- ---
Taking out and lifting of existing submersible pump set of any capacity, for carrying out repair/ overhauling of pump/ rewinding motor alongwith column pipe of 50/80 mm bore with submersible cable from the bore well of depth upto 70 to 140 m and transporting to work shop, replacement of defective parts, opening, cleaning, oiling, greasing and reinstallation including testing, commissioning complete all as specified. Note:- Spare parts if replaced shall be measured and paid under relevant item.
Supply only submersible motor bearing bush of capacity suitable for upto 25 HP as per existing size and make complete all as specified and directed.
All as per item No. 40 above here in before but for submersible motor base complete.
All as per item No. 40 above here in before but for submersible motor base plate.
All as per item No. 40 above here in before but for submersible motor upper housing .
All as per item No. 40 above here in before but for submersible motor TB axial.
All as per item No. 40 above here in before but for submersible motor RT disc.
All as per item No. 40 above here in before but for submersible motor upper flange.
All as per item No. 40 above here in before but for submersible motor TB housing.
All as per item No. 40 above here in before but for submersible motor adopter piece complete.
All as per item No. 40 above here in before but for submersible motor cable joint.
All as per item No. 40 above here in before but for submersible motor stater circlip.
All as per item No. 40 above here in before but for submersible motor rotor circlip.
All as per item No. 40 above here in before but for submersible motor coupling.
All as per item No. 40 above here in before but for submersible motor rotor sleeve.
All as per item No. 40 above here in before but for submersible motor water seal 'O' Ring.
All as per item No. 40 above here in before but for submersible motor upper/ lower flange stud .
Supply only submersible pump neck ring of capacity suitable for upto 25 HP as per existing size and make complete all as directed.
All as per item No. 56 above here in before but for submersible pump bearing bush.
All as per item No. 56 above here in before but for submersible pump bearing sleeves .
All as per item No. 56 above here in before but for submersible pump impeller.
All as per item No. 56 above here in before but for submersible pump stage casing.
All as per item No. 56 above here in before but for submersible pump suction housing.
All as per item No. 56 above here in before but for submersible pump distance sleeves.
All as per item No. 56 above here in before but for submersible pump suction housing bush.
All as per item No. 56 above here in before but for submersible pump coupling.
All as per item No. 56 above here in before but for submersible pump locking screw.
All as per item No. 56 above here in before but for submersible pump stainer.
All as per item No. 56 above here in before but for submersible pump DOL bush.
All as per item No. 56 above here in before but for submersible pump DOL sleeve.
All as per item No. 56 above here in before but for submersible pump distance bush.
All as per item No. 56 above here in before but for submersible pump body nut.
All as per item No. 56 above here in before but for submersible pump body stud.
All as per item No. 56 above here in before but for submersible pump shaft.
All as per item No. 56 above here in before but for submersible pump shaft key.
All as per item No. 56 above here in before but for submersible pump intermediate piece.
All as per item No. 56 above here in before but for submersible pump intermediate sleeves.
Supply and fix MS spindle of existing size 150 mm (6"dia) duly threaded with nut (Gutka) as per existing size and make including replacement of rubber packing with nut and bolts complete all as specified and directed.
All as per item No. 76 above here in before but of existing size 100 mm (4"dia).
All as per item No. 76 above here in before but of existing size 80 mm (3"dia).
Material and labour for repair of leakages in galvanised iron pipes of any size (as above sizes) with all accessories as required on ground, all as per required and directed by engg In charge.(Note ; Rate of accessories to be included in unit rate quoted)
Supply and fix cast Iron Non return Valve flanged 1082 with gun metal discs and nitrile rubber lining test pressure 20Kg/cm2 for 80 mm size complete all as specified.
M and L for repair of pressure pump any type any capacity upto 1 HP, with all accessories as required on ground, all as per required and directed by engg In charge.(Note ; Rate of accessories to be included in unit rate quoted)
S & F in repair GI socket 40 /50 mm size medium grade complete all as specified and directed .
S & F in repair GI socket 80 mm heavy duty size complete all as specified and directed .
S & F in repair GI socket 80 mm medium duty size complete all as specified and directed .
S & F in repair GI nipple 40/50 mm size medium grade complete all as specified and directed .
S & F in repair GI nipple 25 mm size complete all as specified and directed .
S & F in repair flange of 80 mm with necessary washers and nuts bolt long size all as per requirement at site complete all as specified and directed.
S & F in repair flange of 50 mm with necessary washers and nuts bolt long size all as per requirement at site complete all as specified and directed.
Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 29,390.00.
M/s SKP CONSTRUCTION
BRICKS ON CLOUD INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .